Rheem Professional Classic Series Atmospheric Specification

T
INTEGRATED HOME COMFORT
Professional Classic™ Atmospheric gas
INTEGRATED HOME COMFORT
water heaters are engineered for more hot water at a low operating cost
Water
Residential Gas
Professional Classic Atmospheric Water Heaters
Efficiency
• .58 - .62 EF
• More hot water at a low operating cost
Performance
• FHR: 50 to 90 gallons for natural gas
• Recovery: 30.3 to 50.5 gallons at a 90 degree rise, based on model
Guardian System™ & Sensor
• Exclusive air/fuel shut-off device
• Maintenance free – no lter to clean
Flame Arrestor PlateCombustion Shut-off System
Maintenance Free
Low Emissions
• Eco-friendly burner, low NOx design
• Meets 40 ng/J NOx requirements
Longer Life
• Rheem exclusive R-Tech (resistored) anode rod provides long-lasting tank protection
High Altitude Compliant
• All models certied up to 6,000 ft. above sea level
• Some models certied up to 10,200 ft. above sea level, check factory for listings
Plus…
• Easy to light – no matches required
• EverKleen
patented system ghts
sediment build-up
• Enhanced ow brass drain valve
• Temperature and pressure relief valve included
• Low lead compliant
• Standard replacement parts
Warranty
• 6-Year limited tank and parts warranty*
With ProtectionPlus™ the 6-year limited
• tank warranty becomes 10-year
* See Residential Warranty Certicate for
complete information
Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efciency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efciency performance criteria.
Professional Classic
Atmospheric
29, 30, 38, 40 and
50-Gallon Capacities
Up to 50,000 Btu/h Natural and LP Gas
† LEED Point = 1
See dimensions chart on back.
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 08/14 WP FORM NO. PROG RH Rev. 1
T
INTEGRATED HOME COMFORT
INTEGRATED HOME COMFORT
Residential Gas
Water
Professional Classic Atmospheric Water Heaters
Professional Classic™ Atmospheric Specifications
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO WATER HT. TO WATER Y P GAL. MODEL E CAP. NUMBER NAT. LP NAT. LP NAT. A B C D E F G H (LBS) NAT. LP
Tall 29 PROG29-32N RH62 32 32.3 50 59-3/4 56-3/8 16-1/8 14-1/2 3 8 50-3/4 3/4 100 0.62
Tall 29 PROG29-30P RH62 30 30.3 59-3/4 56-3/8 16-1/8 14-1/2 3 8 50-3/4 3/4 100 0.62
Tall 40 PROG40-36N RH59 36 36.4 67 61-1/2 58 17-3/4 14-1/2 3 or 4 8 53 3/4 120 0.59
Tall 40 PROG40-38N RH59 38 38.4 73 61-3/4 58-3/8 18-1/8 14-1/2 3 or 4 8 52-1/4 3/4 120 0.59
Tall 40 PROG40-32P RH59 32 32.3 61-3/4 58-3/8 18-1/8 14-1/2 3 or 4 8 52-1/4 3/4 120 0.59
Tall 38 PROG38-40N RH60 40 40.4 68 61-1/2 57-3/4 19-3/4 14-1/2 3 or 4 8 52-1/4 3/4 125 0.60
Tall 38 PROG38-34P RH60 34 34.3 61-1/2 57-3/4 19-3/4 14-1/2 3 or 4 8 52-1/4 3/4 125 0.60
Tall 40 PROG40-40N RH62† 40 40.4 68 63-1/4 59-3/4 21 14-1/2 3 or 4 8 53-1/2 3/4 135 0.62
Tall 40 PROG40-34P RH60 34 34.3 63-1/4 59-3/4 21 14-1/2 3 or 4 8 53-1/2 3/4 135 0.60
Tall 50 PROG50-40N RH62† 40 40.4 83 62-1/4 58-3/4 23 14-1/2 3 or 4 8 52-1/2 3/4 165 0.62
Tall 50 PROG50-36P RH62† 36 36.4 62-1/4 58-3/4 23 14-1/2 3 or 4 8 52-1/2 3/4 165 0.62
Tall 50 PROG50-38N RH58 38 38.4 90 61-1/2 58-1/4 20-1/8 14-1/2 3 or 4 8 51-3/8 3/4 130 0.58
Tall 50 PROG50-36P RH58 36 36.4 61-1/2 58-1/4 20-1/8 14-1/2 3 or 4 8 51-3/8 3/4 130 0.58
Tall 50 PROG50-40N RH58 40 40.4 82 61-1/2 58 21-3/4 14-1/2 3 or 4 8 52-1/2 3/4 150 0.58
Tall 50 PROG50-36P RH58 V2 36 36.4 61-1/2 58 21-3/4 14-1/2 3 or 4 8 52-1/2 3/4 150 0.58
Tall 50 PROG50-50N RH58 50 50.5 81 62 58 21-3/4 14-1/2 4 8 52-1/2 3/4 150 0.58
Short 30 PROG30S-30N RH61 30 30.3 50 49-3/4 46-1/4 19-3/4 14-1/2 3 8 40-1/4 3/4 98 0.61
Short 40 PROG40S-40N RH62† 40 40.4 72 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.62
Short 40 PROG40S-36P RH62† 36 36.4 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.62
Short 40 PROG40S-36N RH59 36 36.4 72 52-3/4 49-3/8 20-1/8 14-1/2 3 8 42-3/4 3/4 130 0.59
Short 40 PROG40S-34P RH59 34 34.3 52-3/4 49-3/8 20-1/8 14-1/2 3 8 42-3/4 3/4 130 0.59
Short 40 PROG40S-40N RH59 40 40.4 72 53-7/8 50-1/2 20-1/8 14-1/2 3 or 4 8 44 3/4 130 0.59
Short 40 PROG40S-36P RH59 36 36.4 53-7/8 50-1/2 20-1/8 14-1/2 3 or 4 8 44 3/4 130 0.59
Short 50 PROG50S-40N RH59 40 40.4 84 54-1/4 49-3/4 22-1/4 14-1/2 3 8 44 3/4 158 0.59
Short 50 PROG50S-36P RH59 36 36.4 54-1/4 49-3/4 22-1/4 14-1/2 3 8 44 3/4 158 0.59
Energy Factor based on D.O.E. (Department of Energy) test procedures.
†LEED Point = 1
GAS INPUT IN RECOVERY IN FIRST HOUR
THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H.
HT. TO TANK GAS VENT CONN. SIDE T&P CONN. SHIP.
VENT HT. DIAM. CONN. SIZE CNTR. VALVE SIZE WT.
FLUE
H
HOT
WATER
CONNECTION
F
E
ENERGY
FACTOR
ANODE ROD
H
COLD
WATER
CONNECTION
3/4" N.P.T.
RELIEF
VALVE
OPENING
C
BA
1/2"
D
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road
Montgomery, Alabama 36117-4305 • www.rheem.com
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 08/14 WP FORM NO. PROG RH Rev. 1
G