Rheem Prestige Series Single Stage Submittal Sheet

SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ..................................
_______
SEER
TOTAL CAPACITY ....................
_______
MBH [kW]
SENSIBLE CAPACITY ..............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ........
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL ..............
_______
°F [°C] DB
_______
°F [°C] WB
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ..................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT........................................
_______
IWC
MOTOR RATING ..........................
_______
HP [W]
ELECTRICAL DATA
POWER SUPPLY ............................
__________ Hz
MINIMUM WIRE SIZE ......................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ............
_______
AMPS
CLEARANCES
ACCESS SIDE 24" [609.6 mm]
AIR INLETS 6" [152 mm]
ABOVE UNIT 60" [1524 mm]
(-)APM- JEZ SERIES – AIR CONDITIONERS EFFICIENCIES TO 16 SEER/13 EER NOMINAL SIZES 1.5-5 TONS [5.28-17.6 kW]
JOB NAME UNIT MODEL NO.
CONTRACTOR COIL MODEL NO.
ENGINEER AIR HANDLER MODEL NO.
SUBMITTED FOR APPROVAL RECORD LOCATION
DATE ORDER NO.
FEATURES FOR (-)APM- JEZ SERIES
• The Comfort Control System™provides on-board diagnostics and fault history for condensing units with single-phase compressors by detecting system and electrical problems without adding sensors. It can also communicate “fault codes” to enabled “L terminal” thermostats. The integrated diagnostics with
Active Protection
prevents compressor operation when potentially harmful
conditions are detected.
• Features an exclusive 7-Segment LED Display. The information display quickly and accurately shows technicians the source of malfunctions.
• Compressor sound blanket is standard to provide quiet operation.
• R410-A Refrigerant
• High Efficiency
• Scroll Compressor
• All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations.
• Powder painted galvanized steel cabinet. The full wrap-around louvered grille protects the coil from damage.
• Copper tube—aluminum fin coils are used on all models.
• The control box is located in the top corner of the cabinet providing for easy access through a service panel.
• Service valves are standard on all models.
• Power and control wiring are kept separate.
• Separate compressor compartment for easy service access.
• Drawn, painted base pan for extra corrosion resistance and sound reduction.
• The automatic high and low pressure controls, and hard start components are standard.
• The filter drier is standard on all models.
• Certified and rated under AHRI Standard 210.
• U.L. and cUL listed.
• Factory limited warranty on all parts as follows:
Conditional Compressor (Registration Required) ..........................Ten (10) Years
Parts................................................................................................Ten (10) Years
(-)APM- JEZ Series Conditional Replacement Warranty:
Manufacturer will provide a replacement model (if an exact replacement is not available, an equivalent product will be provided) to the original purchaser if the compressor fails within 5 years. See product warranty card for additional information.
FIELD INSTALLED ACCESSORIES
Low Ambient Control ........................................................................................
Compressor Crankcase Heater ........................................................................
Featuring the
Comfort Control System
• Increased Reliability
• On-Board Diagnostics
• Fault Recall
Active Protection
(IN CERTAIN MATCHED SYSTEMS)
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with
appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
FORM NO. X33-1405
Supersedes Form No. X33-1277