Rheem RARL-JEZ, Prestige RARL-JEZ Series User Manual

Page 1
Rheem Prestige Series™Two-Stage Air Conditioners equipped with the Comfort Control System
FORM NO. A11-213
Efficiencies up to 16.5 SEER/13.0 EER Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kW] Cooling Capacities 25.2 to 59 kBTU [7.38 to 17.29 kW]
• The Comfort Control System™ provides on-board diagnos- tics and fault history for condensing units with single-phase compressors by detecting system and electrical problems without adding sensors. It can also communicate “fault codes” to enabled “L terminal” thermostats. The integrated diagnostics with Active Protection prevents compressor oper­ation when damage would occur.
• 7-Segment LED Display is exclusive only to Rheem products. The information-display quickly and accurately shows techni­cians the source of malfunctions.
• Features a ten-year conditional unit replacement warranty when properly installed with a new Rheem Air Handler or Rheem Indoor Coil with a Rheem Gas Furnace. See product warranty card for additional information.
• Compressor sound blanket is standard to provide quiet operation.
• Reliable Two-Stage Scroll™ Compressor for precise tempera­ture control providing ultimate comfort.
• Comfort Alert™ Diagnostics comes installed in each Rheem Prestige Series™ model.
• All controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil.
• Attractive, louvered wrap-around jacket protects the coil from yard hazards and weather extremes. Top grille is steel rein­forced for extra strength. Cabinet is powder painted for all­weather protection.
• Air is discharged upward away from bushes and shrubs. The discharge pattern of the top grille provides minimum air restriction, resulting in quiet fan operation.
• Exclusive Combination Grille/Motor Mount secures the motor to the underside of the discharge grille. The grille protects the motor windings and bearings from rain and snow.
• For quiet operation and improved efficiency, the 2, 3, and 4 ton models feature an 8-pole motor with a 3-blade outdoor fan. The 5 ton model features the GE
®
ECM two-speed motor
with a 3-blade outdoor fan.
• All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Test­ing Apparatus.
• On-demand dehumidification terminal, when matched with a Prestige Series™ Air Handler or premium ECM Gas Furnace products, adjusts airflow to help control humidity, for unsur­passed comfort in the cooling mode.
Air
Air Conditioners
RARL- JEZ Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Contractor for details or visit www.energystar.gov.”
16.0
Page 2
Air
Table of Contents
RARL- JEZ Series
2
TABLE OF CONTENTS
Model Features ........................................................................................................3
Model Number Identification ............................................................................4
Accessories....................................................................................................4
Scroll Compressor ..........................................................................................4
Performance Data ......................................................................................5-28
Electrical & Physical Data ..............................................................................29
Unit Dimensions............................................................................................30
Refrigerant Line Size Information ....................................................................31
Limited Warranty ..........................................................................................32
Page 3
Standard Features
RARL- JEZ Condensing Units
1. Scroll compressor is hermetically sealed and incorporates internal high temperature motor overload protection, and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise.
2. Compressors have an internal pressure relief assembly to protect against excessive pressure differential.
3. All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations.
4. Cabinet is constructed of powder painted galvanized steel. The full wrap-around louvered grille protects the coil from damage.
5. Sound Blanket-enhanced compressor sound blanket is standard.
6. Copper tube—aluminum fin coils are used on all models.
7. The control box is located in the top corner of the cabinet
providing for easy access through a service panel.
8. Service valves are standard on all models.
9. Field connections for power and control wiring are kept
separate.
10. Every unit is factory charged and run-tested.
11. Separate compressor compartment for easy service access.
12. Drawn, painted base pan for extra corrosion resistance and
sound reduction.
13. The RARL- JEZ has a 10-year limited parts warranty, plus a 10-year conditional unit replacement warranty. Refer to the General Terms of Limited Warranty for details.
14. Hard Start Kits—Standard on all JEZ models.
15. Control Box Cover.
16. The RARL- JEZ is shipped with a liquid line filter drier, and
also features factory-installed low and high pressure controls, and time delay control.
17. The 2, 3 and 4 ton models feature an 8-pole motor with a 3-blade outdoor fan. The 5 ton model features the GE
®
ECM two-speed motor with a 3-blade outdoor fan.
The Rheem exclusive Dual 7-Segment LED Display easily shows system operating status codes and diagnostic codes.
A Sealed Switch replaces the standard
contactor and features optical control and latching mecha­nism. The sealed
switch prevents infiltration of insects and dust. A minimal switching arc, by the optical control, offers greater reliability. The latching mechanism con­sumes less power while reducing chatter.
The Status Indication and System Diagnostics feature ther­mostat communication capability, built-in diagnostics, high & low voltage monitoring and high & low pressure switch monitoring. The thermostat communication capability alerts the
homeowner to any necessary service requirements. Faster, more accurate service is provided by the built-in diagnostics, by providing the HVAC professional with dependable infor­mation. With the high and low voltage monitoring feature, the control provides alerts for out-of-range con­ditions. In addition, high and low pressure-switch monitoring pre­vents the system from operating outside of its normal parameters.
The fault recall feature will allow for the last six fault-codes to be displayed, and will retain these codes even if power failure occurs.
Built-in short-cycle protection allows the compressor to restart easily without oil removal.
A 30-second minimum run-time for every compressor call allows the oil to return to the compressor.
Active Protection monitors the system to prevent nuisance lockouts and prevents compressor operation when poten­tially harmful conditions are detected.
The compressor and fan are controlled independently, which reduces the starting load and light dimming.
A manual push-button is offered to operate the com­pressor and fan for 5 seconds to allow for an operation check.
In order to save time and money, replacement automotive fuses can be utilized instead of replacing the entire control board.
3
Air
Model Features
RARL- JEZ Series
The
Comfort Control System
Features:
Scroll Two-Stage Ultra Tech
Compressor
The 2-Stage Scroll UltraTech™compressor is the key to efficiency for this Rheem model. It’s the latest in high-efficiency compressor technology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The Scroll UltraTech™ also has low start torque, eliminating start problems in the field. And its unique design enables the RARL- JEZ condensing unit to perform efficiently, quietly and reliably.
All controls and compressor
are accessible for servicing by
removal of the service panel.
Page 4
Air
Model I.D./Accessories/Compressor
RARL- JEZ Series
4
Model Number Identification
R A R L 024
COOLING
CAPACITY
025 = 24,000 BTU/HR [7.03 kW] 038 = 36,000 BTU/HR [10.55 kW] 049 = 48,000 BTU/HR [14.07 kW] 061 = 60,000 BTU/HR [17.06 kW]
J E Z
RHEEM REMOTE
CONDENSING
UNIT
16-SEER DESIGN
SERIES
ELECTRICAL
DESIGNATION
J = 208/230V-1-60
VARIATIONS
E = EQUIPPED
WITH THE
COMFORT CONTROL
SYSTEM
COOLING
CONNECTION
FITTING
Z = SWEAT
W/SCROLL
Accessories
Low Ambient Control (RXAD-A08)
Crankcase Heater
* Photos are representative. Actual models may vary.
For detailed thermostat match-up information, see specification sheet form number T11-001.
300-Series *
Deluxe Programmable
400-Series *
Special Applications/ Programmable
500-Series *
Communicating/ Programmable
200-Series *
Programmable
Scroll®Compressor
The reliable scroll compressor is the key to efficiency for this Rheem model. It’s the latest in high-efficiency compressor tech­nology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The scroll compressor also has low start torque, reducing start problems in the field. And its unique design enables air conditioners to perform efficiently and quietly.
[ ] Designates Metric Conversions
Thermostats
Page 5
5
Air
Performance Data
RARL- JEZ Series
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEZ
RCSN-H*2421
RHPN-HM2421
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6300 [1.8] 825 [389] 74
1 - dehumid 11400 [3.3] 5000 [1.5] 450 [212]
2 - dehumid 17100 [5.0] 6700 [2.0] 675 [319]
RCFL-H*2417
RGFE-06?MCK?
1 16000 [4.7] 4200 [1.2]
24800 [7.3] 15.5 12.5
575 [271] 71
2 18300 [5.4] 6500 [1.9] 800 [378] 74
RGFE-07?MCK?
1 16300 [4.8] 4100 [1.2]
24600 [7.2] 16 13
600 [283] 71
2 18100 [5.3] 6500 [1.9] 825 [389] 74
RGFG-06?MCK?
1 16000 [4.7] 4200 [1.2]
24800 [7.3] 15.5 12.5
575 [271] 71
2 18300 [5.4] 6500 [1.9] 800 [378] 74
RGFG-07?MCK?
1 16300 [4.8] 4100 [1.2]
24600 [7.2] 16 12.5
600 [283] 71
2 18100 [5.3] 6500 [1.9] 850 [401] 74
RGGE-06?MCK?
1 16300 [4.8] 4100 [1.2]
24800 [7.3] 16 13
625 [295] 71
2 18300 [5.4] 6500 [1.9] 825 [389] 74
RGGE-07?MCK?
1 16000 [4.7] 4200 [1.2]
24800 [7.3] 15.5 12.5
575 [271] 71
2 18300 [5.4] 6500 [1.9] 800 [378] 74
RGJF-06?MCK?
1 16300 [4.8] 4100 [1.2]
24800 [7.3] 16 13
625 [295] 71
2 18300 [5.4] 6500 [1.9] 825 [389] 74
RGJF-07?MCK?
1 16000 [4.7] 4200 [1.2]
24800 [7.3] 15.5 12.5
575 [271] 71
2 18300 [5.4] 6500 [1.9] 800 [378] 74
RGLE-07?AMK?
1 16300 [4.8] 4100 [1.2]
24800 [7.3] 16 13
600 [283] 71
2 18300 [5.4] 6500 [1.9] 800 [378] 74
RGPE-05?BMK?
1 16000 [4.7] 4200 [1.2]
24800 [7.3] 15.5 12.5
575 [271] 71
2 18300 [5.4] 6500 [1.9] 800 [378] 74
RGPE-07?AMK?
1 16300 [4.8] 4100 [1.2]
24800 [7.3] 16 13
625 [295] 71
2 18300 [5.4] 6500 [1.9] 825 [389] 74
RGRM-04?MAE?
1 15800 [4.6] 4200 [1.2]
24600 [7.2] 15.5 12.5
575 [271] 71
2 18100 [5.3] 6500 [1.9] 800 [378] 74
RGRM-06?MAE?
1 16300 [4.8] 4100 [1.2]
24600 [7.2] 16 12.5
600 [283] 71
2 18100 [5.3] 6500 [1.9] 825 [389] 74
RGRM-07?MAE?
1 16300 [4.8] 4100 [1.2]
24400 [7.1] 15.5 12.5
625 [295] 71
2 17900 [5.2] 6500 [1.9] 850 [401] 74
RGTM-06?MAE?
1 17200 [5.0] 3800 [1.1]
24600 [7.2] 15.5 12.5
750 [354] 71
2 18100 [5.3] 6500 [1.9] 825 [389] 74
ROCA-070E03
1 16300 [4.8] 4100 [1.2]
24800 [7.3] 16 13
600 [283] 71
2 18300 [5.4] 6500 [1.9] 800 [378] 74
ROLA-070E03
1 16300 [4.8] 4100 [1.2]
24800 [7.3] 15.5 12.5
600 [283] 71
2 18300 [5.4] 6500 [1.9] 800 [378] 74
RCFL-H*2417+RXMD-C06 Coil Only
1 15800 [4.6] 4100 [1.2]
24200 [7.1] 14 11.5
625 [295] 71
2 17700 [5.2] 6500 [1.9] 825 [389] 74
RCFL-H*2617
RGFE-06?MCK?
1 16400 [4.8] 4200 [1.2]
25600 [7.5] 16.5 13
575 [271] 71
2 18900 [5.5] 6700 [2.0] 800 [378] 74
RGFE-07?MCK?
1 16900 [5.0] 4100 [1.2]
25600 [7.5] 16.5 13
600 [283] 71
2 18900 [5.5] 6700 [2.0] 825 [389] 74
RGFG-06?MCK?
1 16400 [4.8] 4200 [1.2]
25600 [7.5] 16.5 13
575 [271] 71
2 18900 [5.5] 6700 [2.0] 800 [378] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Page 6
Air
Performance Data
RARL- JEZ Series
6
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEZ
RCFL-H*2617
RGFG-07?MCK?
1 16900 [5.0] 4100 [1.2]
25600 [7.5] 16.5 13
600 [283] 71
2 18900 [5.5] 6700 [2.0] 850 [401] 74
RGGE-06?MCK?
1 16900 [5.0] 4100 [1.2]
25600 [7.5] 16.5 13
625 [295] 71
2 18900 [5.5] 6700 [2.0] 825 [389] 74
RGGE-07?MCK?
1 16400 [4.8] 4200 [1.2]
25600 [7.5] 16.5 13
575 [271] 71
2 18900 [5.5] 6700 [2.0] 800 [378] 74
RGJF-06?MCK?
1 16900 [5.0] 4100 [1.2]
25600 [7.5] 16.5 13
625 [295] 71
2 18900 [5.5] 6700 [2.0] 825 [389] 74
RGJF-07?MCK?
1 16400 [4.8] 4200 [1.2]
25600 [7.5] 16.5 13
575 [271] 71
2 18900 [5.5] 6700 [2.0] 800 [378] 74
RGLE-07?AMK?
1 16900 [5.0] 4100 [1.2]
25600 [7.5] 16.5 13
600 [283] 71
2 18900 [5.5] 6700 [2.0] 800 [378] 74
RGPE-05?BMK?
1 16400 [4.8] 4200 [1.2]
25600 [7.5] 16.5 13
575 [271] 71
2 18900 [5.5] 6700 [2.0] 800 [378] 74
RGPE-07?AMK?
1 16900 [5.0] 4100 [1.2]
25600 [7.5] 16.5 13
625 [295] 71
2 18900 [5.5] 6700 [2.0] 825 [389] 74
RGRM-04?MAE?
1 16400 [4.8] 4200 [1.2]
25600 [7.5] 16 13
575 [271] 71
2 18900 [5.5] 6700 [2.0] 800 [378] 74
RGRM-06?MAE?
1 16900 [5.0] 4100 [1.2]
25600 [7.5] 16.5 13
600 [283] 71
2 18900 [5.5] 6700 [2.0] 825 [389] 74
RGRM-07?MAE?
1 16700 [4.9] 4100 [1.2]
25400 [7.4] 16 13
625 [295] 71
2 18700 [5.5] 6700 [2.0] 850 [401] 74
RGTM-06?MAE?
1 17800 [5.2] 3800 [1.1]
25600 [7.5] 16 13
750 [354] 71
2 18900 [5.5] 6700 [2.0] 825 [389] 74
ROCA-070E03
1 16900 [5.0] 4100 [1.2]
25600 [7.5] 16.5 13
600 [283] 71
2 18900 [5.5] 6700 [2.0] 800 [378] 74
ROLA-070E03
1 16900 [5.0] 4100 [1.2]
25600 [7.5] 16.5 13
600 [283] 71
2 18900 [5.5] 6700 [2.0] 800 [378] 74
RCFL-H*2617+RXMD-C06 Coil Only
1 16300 [4.8] 4100 [1.2]
25000 [7.3] 14.5 12
625 [295] 71
2 18300 [5.4] 6700 [2.0] 825 [389] 74
RCFL-H*2621
RGFE-06?MCK?
1 16200 [4.7] 4200 [1.2]
25400 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6500 [1.9] 800 [378] 74
RGFE-07?MCK?
1 16800 [4.9] 4000 [1.2]
25400 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6500 [1.9] 825 [389] 74
RGFG-06?MCK?
1 16200 [4.7] 4200 [1.2]
25400 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6500 [1.9] 800 [378] 74
RGFG-07?MCK?
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
600 [283] 71
2 18700 [5.5] 6500 [1.9] 850 [401] 74
RGGE-06?MCK?
1 16800 [4.9] 4000 [1.2]
25400 [7.4] 16.5 13
625 [295] 71
2 18900 [5.5] 6500 [1.9] 825 [389] 74
RGGE-07?MCK?
1 16400 [4.8] 4200 [1.2]
25400 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6500 [1.9] 800 [378] 74
RGJF-06?MCK?
1 16800 [4.9] 4000 [1.2]
25400 [7.4] 16.5 13
625 [295] 71
2 18900 [5.5] 6500 [1.9] 825 [389] 74
RGJF-07?MCK?
1 16400 [4.8] 4200 [1.2]
25400 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6500 [1.9] 800 [378] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Page 7
7
Air
Performance Data
RARL- JEZ Series
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEZ
RCFL-H*2621
RGLE-07?AMK?
1 16800 [4.9] 4000 [1.2]
25400 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6500 [1.9] 800 [378] 74
RGPE-05?BMK?
1 16400 [4.8] 4200 [1.2]
25400 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6500 [1.9] 800 [378] 74
RGPE-07?AMK?
1 16800 [4.9] 4000 [1.2]
25400 [7.4] 16.5 13
625 [295] 71
2 18900 [5.5] 6500 [1.9] 825 [389] 74
RGRM-04?MAE?
1 16200 [4.7] 4200 [1.2]
25200 [7.4] 16.5 13
575 [271] 71
2 18700 [5.5] 6500 [1.9] 800 [378] 74
RGRM-06?MAE?
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
600 [283] 71
2 18700 [5.5] 6500 [1.9] 825 [389] 74
RGRM-07?MAE?
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16 13
625 [295] 71
2 18700 [5.5] 6500 [1.9] 850 [401] 74
RGTM-06?MAE?
1 17700 [5.2] 3700 [1.1]
25400 [7.4] 16.5 13
750 [354] 71
2 18900 [5.5] 6500 [1.9] 825 [389] 74
ROCA-070E03
1 16800 [4.9] 4000 [1.2]
25400 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6500 [1.9] 800 [378] 74
ROLA-070E03
1 16800 [4.9] 4000 [1.2]
25400 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6500 [1.9] 800 [378] 74
RCFL-H*2621+RXMD-C06 Coil Only
1 16200 [4.7] 4000 [1.2]
24800 [7.3] 14.5 12
625 [295] 71
2 18300 [5.4] 6500 [1.9] 825 [389] 74
RCFN-H*2417
RGFE-06?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
575 [271] 71
2 18700 [5.5] 6300 [1.8] 800 [378] 74
RGFE-07?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
600 [283] 71
2 18700 [5.5] 6300 [1.8] 825 [389] 74
RGFG-06?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
575 [271] 71
2 18700 [5.5] 6300 [1.8] 800 [378] 74
RGFG-07?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16 13
600 [283] 71
2 18700 [5.5] 6300 [1.8] 850 [401] 74
RGGE-06?MCK?
1 17300 [5.1] 3900 [1.1]
25200 [7.4] 16.5 13
625 [295] 71
2 18900 [5.5] 6300 [1.8] 825 [389] 74
RGGE-07?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
575 [271] 71
2 18700 [5.5] 6300 [1.8] 800 [378] 74
RGJF-06?MCK?
1 17300 [5.1] 3900 [1.1]
25200 [7.4] 16.5 13
625 [295] 71
2 18900 [5.5] 6300 [1.8] 825 [389] 74
RGJF-07?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
575 [271] 71
2 18700 [5.5] 6300 [1.8] 800 [378] 74
RGLE-07?AMK?
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
RGPE-05?BMK?
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
RGPE-07?AMK?
1 17300 [5.1] 3900 [1.1]
25200 [7.4] 16.5 13
625 [295] 71
2 18900 [5.5] 6300 [1.8] 825 [389] 74
RGRM-04?MAE?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
575 [271] 71
2 18700 [5.5] 6300 [1.8] 800 [378] 74
RGRM-06?MAE?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
600 [283] 71
2 18700 [5.5] 6300 [1.8] 825 [389] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Page 8
Air
Performance Data
RARL- JEZ Series
8
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEZ
RCFN-H*2417
RGRM-07?MAE?
1 17100 [5.0] 3900 [1.1]
24800 [7.3] 16 12.5
625 [295] 71
2 18500 [5.4] 6300 [1.8] 850 [401] 74
RGTM-06?MAE?
1 18200 [5.3] 3600 [1.1]
25000 [7.3] 16.5 13
750 [354] 71
2 18700 [5.5] 6300 [1.8] 825 [389] 74
ROCA-070E03
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
ROLA-070E03
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
RCFN-H*2417+RXMD-C06 Coil Only
1 16700 [4.9] 3900 [1.1]
24600 [7.2] 14 12
625 [295] 71
2 18300 [5.4] 6300 [1.8] 825 [389] 74
RCFN-H*2421
RGFE-06?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
575 [271] 71
2 18700 [5.5] 6300 [1.8] 800 [378] 74
RGFE-07?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
600 [283] 71
2 18700 [5.5] 6300 [1.8] 825 [389] 74
RGFG-06?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
575 [271] 71
2 18700 [5.5] 6300 [1.8] 800 [378] 74
RGFG-07?MCK?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16 13
600 [283] 71
2 18700 [5.5] 6300 [1.8] 850 [401] 74
RGGE-06?MCK?
1 17300 [5.1] 3900 [1.1]
25200 [7.4] 16.5 13
625 [295] 71
2 18900 [5.5] 6300 [1.8] 825 [389] 74
RGGE-07?MCK?
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
RGJF-06?MCK?
1 17300 [5.1] 3900 [1.1]
25200 [7.4] 16.5 13
625 [295] 71
2 18900 [5.5] 6300 [1.8] 825 [389] 74
RGJF-07?MCK?
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
RGLE-07?AMK?
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
RGPE-05?BMK?
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
575 [271] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
RGPE-07?AMK?
1 17300 [5.1] 3900 [1.1]
25200 [7.4] 16.5 13
625 [295] 71
2 18900 [5.5] 6300 [1.8] 825 [389] 74
RGRM-04?MAE?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
575 [271] 71
2 18700 [5.5] 6300 [1.8] 800 [378] 74
RGRM-06?MAE?
1 16800 [4.9] 4000 [1.2]
25000 [7.3] 16.5 13
600 [283] 71
2 18700 [5.5] 6300 [1.8] 825 [389] 74
RGRM-07?MAE?
1 17100 [5.0] 3900 [1.1]
24800 [7.3] 16 12.5
625 [295] 71
2 18500 [5.4] 6300 [1.8] 850 [401] 74
RGTM-06?MAE?
1 18200 [5.3] 3600 [1.1]
25000 [7.3] 16.5 13
750 [354] 71
2 18700 [5.5] 6300 [1.8] 825 [389] 74
ROCA-070E03
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
ROLA-070E03
1 16800 [4.9] 4000 [1.2]
25200 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6300 [1.8] 800 [378] 74
RCFN-H*2421+RXMD-C06 Coil Only
1 16700 [4.9] 3900 [1.1]
24600 [7.2] 14 12
625 [295] 71
2 18300 [5.4] 6300 [1.8] 825 [389] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Page 9
9
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEZ
RCQD-2417
RBHM-17J
1 17500 [5.1] 3500 [1.0]
25600 [7.5] 16.5 13
600 [283] 71
2 20100 [5.9] 5500 [1.6] 825 [389] 74
RGFE-06?MCK?
1 17000 [5.0] 3600 [1.1]
25600 [7.5] 16.5 13
575 [271] 71
2 20100 [5.9] 5500 [1.6] 800 [378] 74
RGFE-07?MCK?
1 17500 [5.1] 3500 [1.0]
25600 [7.5] 16.5 13
600 [283] 71
2 20100 [5.9] 5500 [1.6] 825 [389] 74
RGFG-06?MCK?
1 17000 [5.0] 3600 [1.1]
25600 [7.5] 16.5 13
575 [271] 71
2 20100 [5.9] 5500 [1.6] 800 [378] 74
RGFG-07?MCK?
1 17500 [5.1] 3500 [1.0]
25400 [7.4] 16.5 13
600 [283] 71
2 19900 [5.8] 5500 [1.6] 850 [401] 74
RGJF-06?MCK?
1 17500 [5.1] 3500 [1.0]
25600 [7.5] 16.5 13
625 [295] 71
2 20100 [5.9] 5500 [1.6] 825 [389] 74
RGJF-07?MCK?
1 17000 [5.0] 3600 [1.1]
25600 [7.5] 16.5 13
575 [271] 71
2 20100 [5.9] 5500 [1.6] 800 [378] 74
RGPE-05?BMK?
1 17000 [5.0] 3600 [1.1]
25600 [7.5] 16.5 13
575 [271] 71
2 20100 [5.9] 5500 [1.6] 800 [378] 74
RGPE-07?AMK?
1 17500 [5.1] 3500 [1.0]
25600 [7.5] 16.5 13
625 [295] 71
2 20100 [5.9] 5500 [1.6] 825 [389] 74
RGRM-04?MAE?
1 17000 [5.0] 3600 [1.1]
25400 [7.4] 16 13
575 [271] 71
2 19900 [5.8] 5500 [1.6] 800 [378] 74
RGRM-06?MAE?
1 17500 [5.1] 3500 [1.0]
25400 [7.4] 16.5 13
600 [283] 71
2 19900 [5.8] 5500 [1.6] 825 [389] 74
RGRM-07?MAE?
1 17300 [5.1] 3500 [1.0]
25400 [7.4] 16 13
625 [295] 71
2 19900 [5.8] 5500 [1.6] 850 [401] 74
RGTM-06?MAE?
1 18500 [5.4] 3100 [0.9]
25600 [7.5] 16.5 13
750 [354] 71
2 20100 [5.9] 5500 [1.6] 825 [389] 74
ROCA-070E03
1 17500 [5.1] 3500 [1.0]
25600 [7.5] 16.5 13
600 [283] 71
2 20100 [5.9] 5500 [1.6] 800 [378] 74
ROLA-070E03
1 17300 [5.1] 3500 [1.0]
25600 [7.5] 16.5 13
600 [283] 71
2 20100 [5.9] 5500 [1.6] 800 [378] 74
RCQD-2417+RXMD-C06 Coil Only
1 16900 [5.0] 3500 [1.0]
25000 [7.3] 14.5 12
625 [295] 71
2 19500 [5.7] 5500 [1.6] 825 [389] 74
RCSL-H*2621 RHPL-HM2421
1 16800 [4.9] 4000 [1.2]
25400 [7.4] 16.5 13
600 [283] 71
2 18900 [5.5] 6500 [1.9] 800 [378] 74
038JEZ
RCSN-H*3624
RHPN-HM3624
1 22400 [6.6] 8600 [2.5]
38000 [11.1] 16.5 13
925 [437] 71
2 27500 [8.1] 10500 [3.1] 1125 [531] 72
1 - dehumid 19000 [5.6] 7400 [2.2] 750 [354]
2 - dehumid 25900 [7.6] 11700 [3.4] 950 [448]
RCFL-H*3617
RGFE-06?MCK?
1 18900 [5.5] 9300 [2.7]
34400 [10.1] 14 11
875 [413] 71
2 23500 [6.9] 10900 [3.2] 1200 [566] 72
RGFE-07?MCK?
1 18900 [5.5] 9300 [2.7]
34400 [10.1] 14 11
875 [413] 71
2 23600 [6.9] 10800 [3.2] 1225 [578] 72
RGFG-06?MCK?
1 17900 [5.2] 9700 [2.8]
33800 [9.9] 14 11.5
725 [342] 71
2 22100 [6.5] 11700 [3.4] 1000 [472] 72
RGFG-07?MCK?
1 18500 [5.4] 9500 [2.8]
33800 [9.9] 14 11.5
800 [378] 71
2 22100 [6.5] 11700 [3.4] 1000 [472] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 10
10
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ
RCFL-H*3617
RGGE-06?MCK?
1 17900 [5.2] 9700 [2.8]
34200 [10.0] 14.5 11.5
725 [342] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGGE-07?MCK?
1 18200 [5.3] 9600 [2.8]
34000 [10.0] 14.5 11.5
750 [354] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
RGJF-06?MCK?
1 17900 [5.2] 9700 [2.8]
34200 [10.0] 14.5 11.5
725 [342] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGJF-07?MCK?
1 18200 [5.3] 9600 [2.8]
34000 [10.0] 14.5 11.5
750 [354] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
RGLE-07?AMK?
1 18200 [5.3] 9600 [2.8]
34200 [10.0] 14.5 12
750 [354] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGPE-05?BMK?
1 19500 [5.7] 9100 [2.7]
34600 [10.1] 14 11
900 [425] 71
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGPE-07?AMK?
1 17900 [5.2] 9700 [2.8]
34000 [10.0] 14.5 11.5
725 [342] 71
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
RGRM-04?MAE?
1 18000 [5.3] 9600 [2.8]
34000 [10.0] 14 11.5
750 [354] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
RGRM-06?MAE?
1 18200 [5.3] 9600 [2.8]
33800 [9.9] 14 11.5
775 [366] 71
2 22100 [6.5] 11700 [3.4] 1000 [472] 72
RGRM-07?MAE?
1 18300 [5.4] 9500 [2.8]
33800 [9.9] 14 11
800 [378] 71
2 22200 [6.5] 11600 [3.4] 1025 [484] 72
RGTM-06?MAE?
1 19500 [5.7] 9100 [2.7]
34000 [10.0] 14 11.5
900 [425] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
ROCA-070E03
1 18500 [5.4] 9500 [2.8]
34000 [10.0] 14.5 12
800 [378] 71
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
ROCA-070E04
1 18500 [5.4] 9500 [2.8]
34000 [10.0] 14.5 12
800 [378] 71
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
ROLA-070E03
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 14.5 11.5
900 [425] 71
2 23800 [7.0] 11000 [3.2] 1175 [554] 72
ROLA-070E04
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 14.5 11.5
900 [425] 71
2 23800 [7.0] 11000 [3.2] 1175 [554] 72
RCFL-H*3617+RXMD-C06 Coil Only
1 18900 [5.5] 9100 [2.7]
34200 [10.0] 13 11
925 [437] 71
2 23000 [6.7] 11200 [3.3] 1075 [507] 72
RCFL-H*3621
RGFE-06?MCK?
1 18900 [5.5] 9300 [2.7]
34400 [10.1] 14 11
875 [413] 71
2 23500 [6.9] 10900 [3.2] 1200 [566] 72
RGFE-07?MCK?
1 18900 [5.5] 9300 [2.7]
34400 [10.1] 14 11
875 [413] 71
2 23600 [6.9] 10800 [3.2] 1225 [578] 72
RGFE-09?ZCM?
1 19100 [5.6] 9300 [2.7]
34800 [10.2] 14.5 11.5
875 [413] 71
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGFE-10?ZCM?
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 14.5 11.5
900 [425] 71
2 24000 [7.0] 10800 [3.2] 1225 [578] 72
RGFG-06?MCK?
1 18900 [5.5] 9300 [2.7]
34400 [10.1] 14 11
875 [413] 71
2 23500 [6.9] 10900 [3.2] 1200 [566] 72
RGFG-07?MCK?
1 18500 [5.4] 9500 [2.8]
33800 [9.9] 14.5 11.5
800 [378] 71
2 22100 [6.5] 11700 [3.4] 1000 [472] 72
RGFG-09?ZCM?
1 19100 [5.6] 9300 [2.7]
34800 [10.2] 14.5 11.5
875 [413] 71
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 11
11
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ RCFL-H*3621
RGFG-10?ZCM?
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 14.5 11.5
900 [425] 71
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGGE-06?MCK?
1 17900 [5.2] 9700 [2.8]
34200 [10.0] 14.5 11.5
725 [342] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGGE-07?MCK?
1 18200 [5.3] 9600 [2.8]
34200 [10.0] 14.5 11.5
750 [354] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGGE-09?ZCM?
1 19100 [5.6] 9300 [2.7]
35000 [10.3] 14.5 11.5
875 [413] 71
2 24200 [7.1] 10800 [3.2] 1225 [578] 72
RGGE-10?ZCM?
1 19100 [5.6] 9300 [2.7]
34800 [10.2] 14.5 11.5
875 [413] 71
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGJF-06?MCK?
1 17900 [5.2] 9700 [2.8]
34200 [10.0] 14.5 11.5
725 [342] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGJF-07?MCK?
1 18200 [5.3] 9600 [2.8]
34200 [10.0] 14.5 11.5
750 [354] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGJF-09?ZCM?
1 19100 [5.6] 9300 [2.7]
35000 [10.3] 14.5 11.5
875 [413] 71
2 24200 [7.1] 10800 [3.2] 1225 [578] 72
RGJF-10?ZCM?
1 19100 [5.6] 9300 [2.7]
34800 [10.2] 14.5 11.5
875 [413] 71
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGLE-07?AMK?
1 19100 [5.6] 9300 [2.7]
34800 [10.2] 14.5 11.5
875 [413] 71
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGLE-07?BRQ?
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 14.5 12
925 [437] 71
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RGLE-10?BRM?
1 19100 [5.6] 9300 [2.7]
35200 [10.3] 15 12
875 [413] 71
2 24300 [7.1] 10900 [3.2] 1200 [566] 72
RGPE-05?BMK?
1 19500 [5.7] 9100 [2.7]
34600 [10.1] 14 11.5
900 [425] 71
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGPE-07?AMK?
1 17900 [5.2] 9700 [2.8]
34000 [10.0] 14.5 12
725 [342] 71
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
RGPE-07?BRQ?
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 14.5 12
900 [425] 71
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RGPE-10?BRM?
1 19700 [5.8] 9100 [2.7]
35200 [10.3] 15 12
900 [425] 71
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RGRM-04?MAE?
1 18000 [5.3] 9600 [2.8]
34000 [10.0] 14 11.5
750 [354] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
RGRM-06?MAE?
1 18200 [5.3] 9600 [2.8]
33800 [9.9] 14.5 11.5
775 [366] 71
2 22100 [6.5] 11700 [3.4] 1000 [472] 72
RGRM-07?MAE?
1 18300 [5.4] 9500 [2.8]
33800 [9.9] 14 11
800 [378] 71
2 22200 [6.5] 11600 [3.4] 1025 [484] 72
RGRM-07?YBG?
1 18700 [5.5] 9300 [2.7]
34200 [10.0] 13.5 10.5
850 [401] 71
2 23300 [6.8] 10900 [3.2] 1200 [566] 72
RGTM-06?MAE?
1 19500 [5.7] 9100 [2.7]
34000 [10.0] 14.5 11.5
900 [425] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
RGTM-07?RBG?
1 18500 [5.4] 9500 [2.8]
34400 [10.1] 14.5 12
800 [378] 71
2 22900 [6.7] 11500 [3.4] 1050 [495] 72
RGTM-09?ZAJ?
1 19800 [5.8] 9000 [2.6]
35000 [10.3] 14.5 11.5
975 [460] 71
2 24200 [7.1] 10800 [3.2] 1225 [578] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 12
12
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ
RCFL-H*3621
ROCA-070E03
1 18500 [5.4] 9500 [2.8]
34200 [10.0] 14.5 12
800 [378] 71
2 22500 [6.6] 11700 [3.4] 1000 [472] 72
ROCA-070E04
1 18500 [5.4] 9500 [2.8]
34200 [10.0] 14.5 12
800 [378] 71
2 22500 [6.6] 11700 [3.4] 1000 [472] 72
ROLA-070E03
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 14.5 11.5
900 [425] 71
2 23800 [7.0] 11000 [3.2] 1175 [554] 72
ROLA-070E04
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 14.5 11.5
900 [425] 71
2 23800 [7.0] 11000 [3.2] 1175 [554] 72
ROLA-115E05
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 14.5 12
900 [425] 71
2 24100 [7.1] 10900 [3.2] 1200 [566] 72
RCFL-H*3621+RXMD-C06 Coil Only
1 18900 [5.5] 9100 [2.7]
34200 [10.0] 13 11
925 [437] 71
2 23000 [6.7] 11200 [3.3] 1125 [531] 72
RCFL-H*3821
RGFE-06?MCK?
1 17800 [5.2] 10000 [2.9]
34600 [10.1] 14.5 12
725 [342] 71
2 22700 [6.7] 11900 [3.5] 1000 [472] 72
RGFE-07?MCK?
1 17800 [5.2] 10000 [2.9]
34600 [10.1] 14.5 12
725 [342] 71
2 22800 [6.7] 11800 [3.5] 1025 [484] 72
RGFE-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35400 [10.4] 15 12
875 [413] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGFE-10?ZCM?
1 19600 [5.7] 9400 [2.8]
35600 [10.4] 15 12
900 [425] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
RGFG-06?MCK?
1 17800 [5.2] 10000 [2.9]
34600 [10.1] 14.5 12
725 [342] 71
2 22700 [6.7] 11900 [3.5] 1000 [472] 72
RGFG-07?MCK?
1 18400 [5.4] 9800 [2.9]
34400 [10.1] 14.5 12
800 [378] 71
2 22500 [6.6] 11900 [3.5] 1000 [472] 72
RGFG-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35400 [10.4] 15 12
875 [413] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGFG-10?ZCM?
1 19600 [5.7] 9400 [2.8]
35400 [10.4] 15 12
900 [425] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGGE-06?MCK?
1 17800 [5.2] 10000 [2.9]
34800 [10.2] 14.5 12
725 [342] 71
2 23000 [6.7] 11800 [3.5] 1025 [484] 72
RGGE-07?MCK?
1 18100 [5.3] 9900 [2.9]
34600 [10.1] 14.5 12
750 [354] 71
2 22800 [6.7] 11800 [3.5] 1025 [484] 72
RGGE-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35600 [10.4] 15 12
875 [413] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
RGGE-10?ZCM?
1 19000 [5.6] 9600 [2.8]
35400 [10.4] 14.5 12
875 [413] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGJF-06?MCK?
1 17800 [5.2] 10000 [2.9]
34800 [10.2] 14.5 12
725 [342] 71
2 23000 [6.7] 11800 [3.5] 1025 [484] 72
RGJF-07?MCK?
1 18100 [5.3] 9900 [2.9]
34600 [10.1] 14.5 12
750 [354] 71
2 22800 [6.7] 11800 [3.5] 1025 [484] 72
RGJF-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35800 [10.5] 15 12
875 [413] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGJF-10?ZCM?
1 19000 [5.6] 9600 [2.8]
35600 [10.4] 14.5 12
875 [413] 71
2 24500 [7.2] 11100 [3.3] 1200 [566] 72
RGLE-07?AMK?
1 18100 [5.3] 9900 [2.9]
34800 [10.2] 15 12
750 [354] 71
2 23000 [6.7] 11800 [3.5] 1025 [484] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 13
13
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ
RCFL-H*3821
RGLE-07?BRQ?
1 18400 [5.4] 9800 [2.9]
35000 [10.3] 15.1 12.5
775 [366] 71
2 23200 [6.8] 11800 [3.5] 1025 [484] 72
RGLE-10?BRM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15.1 12.5
875 [413] 71
2 24700 [7.2] 11100 [3.3] 1200 [566] 72
RGPE-05?BMK?
1 19400 [5.7] 9400 [2.8]
35200 [10.3] 14.5 11.5
900 [425] 71
2 24100 [7.1] 11100 [3.3] 1200 [566] 72
RGPE-07?AMK?
1 19600 [5.7] 9400 [2.8]
35600 [10.4] 14.5 12
900 [425] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
RGPE-07?BRQ?
1 19600 [5.7] 9400 [2.8]
35800 [10.5] 15.1 12.5
900 [425] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGPE-10?BRM?
1 19600 [5.7] 9400 [2.8]
35800 [10.5] 15.1 12.5
900 [425] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGRM-04?MAE?
1 18100 [5.3] 9900 [2.9]
34600 [10.1] 14.5 11.5
750 [354] 71
2 22800 [6.7] 11800 [3.5] 1025 [484] 72
RGRM-06?MAE?
1 18400 [5.4] 9800 [2.9]
34400 [10.1] 14.5 12
775 [366] 71
2 22500 [6.6] 11900 [3.5] 1000 [472] 72
RGRM-07?MAE?
1 18400 [5.4] 9800 [2.9]
34400 [10.1] 14.5 11.5
800 [378] 71
2 22600 [6.6] 11800 [3.5] 1025 [484] 72
RGRM-07?YBG?
1 18800 [5.5] 9600 [2.8]
34800 [10.2] 14 11
850 [401] 71
2 23700 [6.9] 11100 [3.3] 1200 [566] 72
RGRM-09?ZAJ?
1 19400 [5.7] 9400 [2.8]
35400 [10.4] 14.5 11.5
950 [448] 71
2 24400 [7.1] 11000 [3.2] 1225 [578] 72
RGRM-10?ZAJ?
1 19000 [5.6] 9600 [2.8]
35000 [10.3] 14.5 12
875 [413] 71
2 23600 [6.9] 11400 [3.3] 1150 [543] 72
RGTM-06?MAE?
1 19400 [5.7] 9400 [2.8]
34600 [10.1] 14.5 12
900 [425] 71
2 22800 [6.7] 11800 [3.5] 1025 [484] 72
RGTM-07?RBG?
1 18600 [5.4] 9800 [2.9]
35000 [10.3] 15 12.5
800 [378] 71
2 23300 [6.8] 11700 [3.4] 1050 [495] 72
RGTM-09?ZAJ?
1 19900 [5.8] 9300 [2.7]
35600 [10.4] 15 12
975 [460] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
ROCA-070E03
1 18600 [5.4] 9800 [2.9]
34600 [10.1] 15 12
800 [378] 71
2 22700 [6.7] 11900 [3.5] 1000 [472] 72
ROCA-070E04
1 18600 [5.4] 9800 [2.9]
34600 [10.1] 15 12
800 [378] 71
2 22700 [6.7] 11900 [3.5] 1000 [472] 72
ROLA-070E03
1 19600 [5.7] 9400 [2.8]
35600 [10.4] 15 12
900 [425] 71
2 24400 [7.1] 11200 [3.3] 1175 [554] 72
ROLA-070E04
1 19600 [5.7] 9400 [2.8]
35600 [10.4] 15 12
900 [425] 71
2 24400 [7.1] 11200 [3.3] 1175 [554] 72
ROLA-115E05
1 19600 [5.7] 9400 [2.8]
35600 [10.4] 15.1 12.5
900 [425] 71
2 24500 [7.2] 11100 [3.3] 1200 [566] 72
RCFL-H*3821+RXMD-C06 Coil Only
1 18800 [5.5] 9400 [2.8]
34800 [10.2] 13 11.5
925 [437] 71
2 23400 [6.9] 11400 [3.3] 1125 [531] 72
RCFL-H*3824
RGFE-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35400 [10.4] 14.5 12
875 [413] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGFE-10?ZCM?
1 19600 [5.7] 9400 [2.8]
35600 [10.4] 15 12
900 [425] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 14
14
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ RCFL-H*3824
RGFE-12?RCM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15 12
875 [413] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGFG-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35400 [10.4] 14.5 12
875 [413] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGFG-10?ZCM?
1 19600 [5.7] 9400 [2.8]
35400 [10.4] 15 12
900 [425] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGFG-12?RCM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15 12
875 [413] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGGE-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35600 [10.4] 15 12
875 [413] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
RGGE-10?ZCM?
1 19000 [5.6] 9600 [2.8]
35400 [10.4] 14.5 12
875 [413] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGGE-12?RCM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15.1 12.5
875 [413] 71
2 24700 [7.2] 11100 [3.3] 1200 [566] 72
RGJF-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35800 [10.5] 15 12
875 [413] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGJF-10?ZCM?
1 19000 [5.6] 9600 [2.8]
35600 [10.4] 14.5 12
875 [413] 71
2 24500 [7.2] 11100 [3.3] 1200 [566] 72
RGJF-12?RCM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15.1 12.5
875 [413] 71
2 24700 [7.2] 11100 [3.3] 1200 [566] 72
RGLE-07?BRQ?
1 18400 [5.4] 9800 [2.9]
35000 [10.3] 15.1 12.5
775 [366] 71
2 23200 [6.8] 11800 [3.5] 1025 [484] 72
RGLE-10?BRM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15.1 12.5
875 [413] 71
2 24700 [7.2] 11100 [3.3] 1200 [566] 72
RGLE-12?ARM?
1 19600 [5.7] 9400 [2.8]
36000 [10.5] 15.1 12.5
925 [437] 71
2 25000 [7.3] 11000 [3.2] 1225 [578] 72
RGPE-07?BRQ?
1 19600 [5.7] 9400 [2.8]
35800 [10.5] 15.1 12.5
900 [425] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGPE-10?BRM?
1 19600 [5.7] 9400 [2.8]
35800 [10.5] 15.1 12.5
900 [425] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGPE-12?ARM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15.1 12.5
875 [413] 71
2 24700 [7.2] 11100 [3.3] 1200 [566] 72
RGRM-07?YBG?
1 18800 [5.5] 9600 [2.8]
34800 [10.2] 14 11
850 [401] 71
2 23700 [6.9] 11100 [3.3] 1200 [566] 72
RGRM-09?ZAJ?
1 19400 [5.7] 9400 [2.8]
35400 [10.4] 14.5 11.5
950 [448] 71
2 24400 [7.1] 11000 [3.2] 1225 [578] 72
RGRM-10?ZAJ?
1 19000 [5.6] 9600 [2.8]
35000 [10.3] 14.5 12
875 [413] 71
2 23600 [6.9] 11400 [3.3] 1150 [543] 72
RGRM-12?RAJ?
1 19600 [5.7] 9400 [2.8]
35600 [10.4] 15 12
925 [437] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
RGTM-07?RBG?
1 18600 [5.4] 9800 [2.9]
35000 [10.3] 15 12.5
800 [378] 71
2 23300 [6.8] 11700 [3.4] 1050 [495] 72
RGTM-09?ZAJ?
1 19900 [5.8] 9300 [2.7]
35600 [10.4] 15 12
975 [460] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
RGTM-10?RBJ?
1 19900 [5.8] 9300 [2.7]
35800 [10.5] 15 12
975 [460] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 15
15
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ
RCFL-H*3824
ROCA-070E03
1 18400 [5.4] 9800 [2.9]
34600 [10.1] 15 12
800 [378] 71
2 22700 [6.7] 11900 [3.5] 1000 [472] 72
ROCA-070E04
1 18400 [5.4] 9800 [2.9]
34600 [10.1] 15 12
800 [378] 71
2 22700 [6.7] 11900 [3.5] 1000 [472] 72
ROLA-070E03
1 19600 [5.7] 9400 [2.8]
35400 [10.4] 15 12
900 [425] 71
2 24200 [7.1] 11200 [3.3] 1175 [554] 72
ROLA-070E04
1 19600 [5.7] 9400 [2.8]
35400 [10.4] 15 12
900 [425] 71
2 24200 [7.1] 11200 [3.3] 1175 [554] 72
ROLA-115E05
1 19600 [5.7] 9400 [2.8]
35600 [10.4] 15 12
900 [425] 71
2 24500 [7.2] 11100 [3.3] 1200 [566] 72
RCFL-H*3824+RXMD-C06 Coil Only
1 18800 [5.5] 9400 [2.8]
34800 [10.2] 13 11.5
925 [437] 71
2 23400 [6.9] 11400 [3.3] 1125 [531] 72
RCFN-H*3624
RGFE-06?MCK?
1 20300 [5.9] 9300 [2.7]
37200 [10.9] 16 12.5
725 [342] 71
2 26100 [7.6] 11100 [3.3] 1000 [472] 72
RGFE-07?MCK?
1 20300 [5.9] 9300 [2.7]
37200 [10.9] 16 12.5
725 [342] 71
2 26200 [7.7] 11000 [3.2] 1025 [484] 72
RGFE-09?ZCM?
1 21800 [6.4] 8800 [2.6]
38000 [11.1] 16 12.5
875 [413] 71
2 27800 [8.1] 10200 [3.0] 1200 [566] 72
RGFE-10?ZCM?
1 22200 [6.5] 8600 [2.5]
38500 [11.3] 16 12.5
900 [425] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGFE-12?RCM?
1 21800 [6.4] 8800 [2.6]
38500 [11.3] 16.5 13
875 [413] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGFG-06?MCK?
1 20300 [5.9] 9300 [2.7]
37200 [10.9] 16 12.5
725 [342] 71
2 26100 [7.6] 11100 [3.3] 1000 [472] 72
RGFG-07?MCK?
1 20900 [6.1] 9100 [2.7]
37000 [10.8] 16 12.5
800 [378] 71
2 25900 [7.6] 11100 [3.3] 1000 [472] 72
RGFG-09?ZCM?
1 21800 [6.4] 8800 [2.6]
38000 [11.1] 16 12.5
875 [413] 71
2 27800 [8.1] 10200 [3.0] 1200 [566] 72
RGFG-10?ZCM?
1 22200 [6.5] 8600 [2.5]
38000 [11.1] 16 12.5
900 [425] 71
2 27800 [8.1] 10200 [3.0] 1200 [566] 72
RGFG-12?RCM?
1 21800 [6.4] 8800 [2.6]
38500 [11.3] 16.5 13
875 [413] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGGE-06?MCK?
1 20500 [6.0] 9300 [2.7]
37400 [11.0] 16 13
725 [342] 71
2 26400 [7.7] 11000 [3.2] 1025 [484] 72
RGGE-07?MCK?
1 20600 [6.0] 9200 [2.7]
37400 [11.0] 16 12.5
750 [354] 71
2 26400 [7.7] 11000 [3.2] 1025 [484] 72
RGGE-09?ZCM?
1 21800 [6.4] 8800 [2.6]
38500 [11.3] 16 13
875 [413] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGGE-10?ZCM?
1 21800 [6.4] 8800 [2.6]
38000 [11.1] 16 13
875 [413] 71
2 27800 [8.1] 10200 [3.0] 1200 [566] 72
RGGE-12?RCM?
1 21800 [6.4] 8800 [2.6]
38500 [11.3] 16.5 13
875 [413] 71
2 28300 [8.3] 10200 [3.0] 1200 [566] 72
RGJF-06?MCK?
1 20500 [6.0] 9300 [2.7]
37400 [11.0] 16 13
725 [342] 71
2 26400 [7.7] 11000 [3.2] 1025 [484] 72
RGJF-07?MCK?
1 20600 [6.0] 9200 [2.7]
37400 [11.0] 16 12.5
750 [354] 71
2 26400 [7.7] 11000 [3.2] 1025 [484] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 16
16
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ RCFN-H*3624
RGJF-09?ZCM?
1 21800 [6.4] 8800 [2.6]
38500 [11.3] 16 13
875 [413] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGJF-10?ZCM?
1 21800 [6.4] 8800 [2.6]
38000 [11.1] 16 13
875 [413] 71
2 27800 [8.1] 10200 [3.0] 1200 [566] 72
RGJF-12?RCM?
1 21800 [6.4] 8800 [2.6]
38500 [11.3] 16.5 13
875 [413] 71
2 28300 [8.3] 10200 [3.0] 1200 [566] 72
RGLE-07?AMK?
1 20600 [6.0] 9200 [2.7]
37400 [11.0] 16 13
750 [354] 71
2 26400 [7.7] 11000 [3.2] 1025 [484] 72
RGLE-07?BRQ?
1 22200 [6.5] 8600 [2.5]
38500 [11.3] 16.5 13
925 [437] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGLE-10?BRM?
1 21800 [6.4] 8800 [2.6]
38500 [11.3] 16.5 13
875 [413] 71
2 28300 [8.3] 10200 [3.0] 1200 [566] 72
RGLE-12?ARM?
1 22400 [6.6] 8600 [2.5]
38500 [11.3] 16.5 13
925 [437] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGPE-05?BMK?
1 22200 [6.5] 8600 [2.5]
38000 [11.1] 16 12.5
900 [425] 71
2 27800 [8.1] 10200 [3.0] 1200 [566] 72
RGPE-07?AMK?
1 20500 [6.0] 9300 [2.7]
37400 [11.0] 16 13
725 [342] 71
2 26300 [7.7] 11100 [3.3] 1000 [472] 72
RGPE-07?BRQ?
1 22400 [6.6] 8600 [2.5]
38500 [11.3] 16.5 13
900 [425] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGPE-10?BRM?
1 22400 [6.6] 8600 [2.5]
38500 [11.3] 16.5 13
900 [425] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGPE-12?ARM?
1 21800 [6.4] 8800 [2.6]
38500 [11.3] 16.5 13
875 [413] 71
2 28300 [8.3] 10200 [3.0] 1200 [566] 72
RGRM-04?MAE?
1 20600 [6.0] 9200 [2.7]
37200 [10.9] 16 12.5
750 [354] 71
2 26200 [7.7] 11000 [3.2] 1025 [484] 72
RGRM-06?MAE?
1 20900 [6.1] 9100 [2.7]
37000 [10.8] 16 12.5
775 [366] 71
2 25900 [7.6] 11100 [3.3] 1000 [472] 72
RGRM-07?MAE?
1 20900 [6.1] 9100 [2.7]
37000 [10.8] 15.5 12
800 [378] 71
2 26000 [7.6] 11000 [3.2] 1025 [484] 72
RGRM-07?YBG?
1 21300 [6.2] 8900 [2.6]
37600 [11.0] 15.5 12
850 [401] 71
2 27400 [8.0] 10200 [3.0] 1200 [566] 72
RGRM-09?ZAJ?
1 22200 [6.5] 8600 [2.5]
38000 [11.1] 16 12.5
950 [448] 71
2 27900 [8.2] 10100 [3.0] 1225 [578] 72
RGRM-10?ZAJ?
1 21800 [6.4] 8800 [2.6]
37800 [11.1] 16 12.5
875 [413] 71
2 27300 [8.0] 10500 [3.1] 1150 [543] 72
RGRM-12?RAJ?
1 22200 [6.5] 8600 [2.5]
38500 [11.3] 16 13
925 [437] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGTM-06?MAE?
1 22200 [6.5] 8600 [2.5]
37400 [11.0] 16 12.5
900 [425] 71
2 26400 [7.7] 11000 [3.2] 1025 [484] 72
RGTM-07?RBG?
1 22200 [6.5] 8600 [2.5]
38500 [11.3] 16 13
950 [448] 71
2 28700 [8.4] 9800 [2.9] 1275 [602] 72
RGTM-09?ZAJ?
1 22500 [6.6] 8500 [2.5]
38500 [11.3] 16 13
975 [460] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGTM-10?RBJ?
1 22700 [6.7] 8500 [2.5]
38500 [11.3] 16 13
975 [460] 71
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 17
17
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ
RCFN-H*3624
ROCA-070E03
1 21100 [6.2] 9100 [2.7]
37400 [11.0] 16 13
800 [378] 71
2 26300 [7.7] 11100 [3.3] 1000 [472] 72
ROCA-070E04
1 21100 [6.2] 9100 [2.7]
37400 [11.0] 16 13
800 [378] 71
2 26300 [7.7] 11100 [3.3] 1000 [472] 72
ROLA-070E03
1 22200 [6.5] 8600 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 27700 [8.1] 10300 [3.0] 1175 [554] 72
ROLA-070E04
1 22200 [6.5] 8600 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 27700 [8.1] 10300 [3.0] 1175 [554] 72
ROLA-115E05
1 22200 [6.5] 8600 [2.5]
38500 [11.3] 16.5 13
900 [425] 71
2 28300 [8.3] 10200 [3.0] 1200 [566] 72
RCFN-H*3624+RXMD-C06 Coil Only
1 21400 [6.3] 8600 [2.5]
37400 [11.0] 14 12
925 [437] 71
2 26900 [7.9] 10500 [3.1] 1125 [531] 72
RCQD-3621
RGFE-06?MCK?
1 19900 [5.8] 9100 [2.7]
36600 [10.7] 15.5 12.5
725 [342] 71
2 25600 [7.5] 11000 [3.2] 1000 [472] 72
RGFE-07?MCK?
1 19900 [5.8] 9100 [2.7]
36600 [10.7] 15.5 12.5
725 [342] 71
2 25700 [7.5] 10900 [3.2] 1025 [484] 72
RGFE-09?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGFE-10?ZCM?
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 15.5 12.5
900 [425] 71
2 27600 [8.1] 10000 [2.9] 1225 [578] 72
RGFG-06?MCK?
1 19900 [5.8] 9100 [2.7]
36600 [10.7] 15.5 12.5
725 [342] 71
2 25600 [7.5] 11000 [3.2] 1000 [472] 72
RGFG-07?MCK?
1 20500 [6.0] 8900 [2.6]
36400 [10.7] 15.5 12.5
800 [378] 71
2 25400 [7.4] 11000 [3.2] 1000 [472] 72
RGFG-09?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGFG-10?ZCM?
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 15.5 12.5
900 [425] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGJF-06?MCK?
1 21600 [6.3] 8400 [2.5]
37400 [11.0] 15.5 12.5
925 [437] 71
2 27300 [8.0] 10100 [3.0] 1200 [566] 72
RGJF-07?MCK?
1 20200 [5.9] 9000 [2.6]
36600 [10.7] 15.5 12.5
750 [354] 71
2 25700 [7.5] 10900 [3.2] 1025 [484] 72
RGJF-09?ZCM?
1 21200 [6.2] 8600 [2.5]
37800 [11.1] 15.5 12.5
875 [413] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
RGJF-10?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGPE-05?BMK?
1 21600 [6.3] 8400 [2.5]
37400 [11.0] 15.5 12
900 [425] 71
2 27300 [8.0] 10100 [3.0] 1200 [566] 72
RGPE-07?AMK?
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 15.5 12.5
900 [425] 71
2 27600 [8.1] 10000 [2.9] 1225 [578] 72
RGPE-07?BRQ?
1 21800 [6.4] 8400 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
RGPE-10?BRM?
1 21800 [6.4] 8400 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
RGRM-04?MAE?
1 20200 [5.9] 9000 [2.6]
36600 [10.7] 15.5 12.5
750 [354] 71
2 25700 [7.5] 10900 [3.2] 1025 [484] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 18
18
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ
RCQD-3621
RGRM-06?MAE?
1 20500 [6.0] 8900 [2.6]
36400 [10.7] 15.5 12.5
775 [366] 71
2 25400 [7.4] 11000 [3.2] 1000 [472] 72
RGRM-07?MAE?
1 20500 [6.0] 8900 [2.6]
36400 [10.7] 15 12
800 [378] 71
2 25500 [7.5] 10900 [3.2] 1025 [484] 72
RGRM-07?YBG?
1 20900 [6.1] 8700 [2.5]
37000 [10.8] 15 11.5
850 [401] 71
2 26900 [7.9] 10100 [3.0] 1200 [566] 72
RGRM-09?ZAJ?
1 21600 [6.3] 8400 [2.5]
37600 [11.0] 15.5 12.5
950 [448] 71
2 27600 [8.1] 10000 [2.9] 1225 [578] 72
RGRM-10?ZAJ?
1 21200 [6.2] 8600 [2.5]
37000 [10.8] 15.5 12.5
875 [413] 71
2 26600 [7.8] 10400 [3.0] 1150 [543] 72
RGTM-06?MAE?
1 21600 [6.3] 8400 [2.5]
36600 [10.7] 15.5 12.5
900 [425] 71
2 25700 [7.5] 10900 [3.2] 1025 [484] 72
RGTM-07?RBG?
1 20500 [6.0] 8900 [2.6]
37000 [10.8] 15.5 13
800 [378] 71
2 26200 [7.7] 10800 [3.2] 1050 [495] 72
RGTM-09?ZAJ?
1 22100 [6.5] 8300 [2.4]
37800 [11.1] 15.5 12.5
975 [460] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
ROCA-070E03
1 20500 [6.0] 8900 [2.6]
36600 [10.7] 15.5 13
800 [378] 71
2 25600 [7.5] 11000 [3.2] 1000 [472] 72
ROCA-070E04
1 20500 [6.0] 8900 [2.6]
36600 [10.7] 15.5 13
800 [378] 71
2 25600 [7.5] 11000 [3.2] 1000 [472] 72
ROLA-070E03
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 15.5 13
900 [425] 71
2 27400 [8.0] 10200 [3.0] 1175 [554] 72
ROLA-070E04
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 15.5 13
900 [425] 71
2 27400 [8.0] 10200 [3.0] 1175 [554] 72
ROLA-115E05
1 21800 [6.4] 8400 [2.5]
37800 [11.1] 16 13
900 [425] 71
2 27700 [8.1] 10100 [3.0] 1200 [566] 72
RCQD-3621+RXMD-C06 Coil Only
1 21000 [6.2] 8400 [2.5]
36800 [10.8] 14 12
925 [437] 71
2 26400 [7.7] 10400 [3.0] 1125 [531] 72
RCQD-3624
RBHM-24J
1 21800 [6.4] 8400 [2.5]
37800 [11.1] 16 13
900 [425] 71
2 27600 [8.1] 10200 [3.0] 1175 [554] 72
RBHN-24J
1 21800 [6.4] 8400 [2.5]
38000 [11.1] 16.5 13
925 [437] 71
2 27800 [8.1] 10200 [3.0] 1175 [554] 72
RGFE-09?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGFE-10?ZCM?
1 21800 [6.4] 8400 [2.5]
37800 [11.1] 16 12.5
900 [425] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
RGFE-12?RCM?
1 21400 [6.3] 8600 [2.5]
37800 [11.1] 16 13
875 [413] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
RGFG-09?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGFG-10?ZCM?
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 15.5 12.5
900 [425] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGFG-12?RCM?
1 21400 [6.3] 8600 [2.5]
37800 [11.1] 16 13
875 [413] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
RGJF-09?ZCM?
1 21200 [6.2] 8600 [2.5]
37800 [11.1] 15.5 13
875 [413] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 19
19
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ
RCQD-3624
RGJF-10?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGJF-12?RCM?
1 21400 [6.3] 8600 [2.5]
37800 [11.1] 16 13
875 [413] 71
2 27700 [8.1] 10100 [3.0] 1200 [566] 72
RGPE-07?BRQ?
1 21800 [6.4] 8400 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
RGPE-10?BRM?
1 21800 [6.4] 8400 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
RGPE-12?ARM?
1 21400 [6.3] 8600 [2.5]
37800 [11.1] 16 13
875 [413] 71
2 27700 [8.1] 10100 [3.0] 1200 [566] 72
RGRM-07?YBG?
1 20900 [6.1] 8700 [2.5]
37000 [10.8] 15 11.5
850 [401] 71
2 26900 [7.9] 10100 [3.0] 1200 [566] 72
RGRM-09?ZAJ?
1 21600 [6.3] 8400 [2.5]
37600 [11.0] 15.5 12.5
950 [448] 71
2 27600 [8.1] 10000 [2.9] 1225 [578] 72
RGRM-10?ZAJ?
1 21200 [6.2] 8600 [2.5]
37200 [10.9] 15.5 12.5
875 [413] 71
2 26800 [7.9] 10400 [3.0] 1150 [543] 72
RGRM-12?RAJ?
1 21800 [6.4] 8400 [2.5]
37800 [11.1] 16 12.5
925 [437] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
RGTM-07?RBG?
1 20500 [6.0] 8900 [2.6]
37000 [10.8] 15.5 13
800 [378] 71
2 26200 [7.7] 10800 [3.2] 1050 [495] 72
RGTM-09?ZAJ?
1 22100 [6.5] 8300 [2.4]
37800 [11.1] 15.5 12.5
975 [460] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
RGTM-10?RBJ?
1 22100 [6.5] 8300 [2.4]
38000 [11.1] 16 13
975 [460] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
ROCA-070E03
1 20500 [6.0] 8900 [2.6]
36800 [10.8] 15.5 13
800 [378] 71
2 25800 [7.6] 11000 [3.2] 1000 [472] 72
ROCA-070E04
1 20500 [6.0] 8900 [2.6]
36800 [10.8] 15.5 13
800 [378] 71
2 25800 [7.6] 11000 [3.2] 1000 [472] 72
ROLA-070E03
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 16 13
900 [425] 71
2 27400 [8.0] 10200 [3.0] 1175 [554] 72
ROLA-070E04
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 16 13
900 [425] 71
2 27400 [8.0] 10200 [3.0] 1175 [554] 72
ROLA-115E05
1 21800 [6.4] 8400 [2.5]
37800 [11.1] 16 13
900 [425] 71
2 27700 [8.1] 10100 [3.0] 1200 [566] 72
RCQD-3624+RXMD-C06 Coil Only
1 21000 [6.2] 8400 [2.5]
36800 [10.8] 14 12
925 [437] 71
2 26400 [7.7] 10400 [3.0] 1125 [531] 72
RCSL-H*3621 RHPL-HM3621
1 19700 [5.8] 9100 [2.7]
35200 [10.3] 15 12
925 [437] 71
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RCSL-H*3821 RHPL-HM3821
1 19600 [5.7] 9400 [2.8]
35400 [10.4] 15 12
950 [448] 71
2 24000 [7.0] 11400 [3.3] 1150 [543] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 20
20
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
049JEZ
RCSN-H*4824
RHPN-HM4824
1 30400 [8.9] 12100 [3.5]
50000 [14.6] 16.5 13
1250 [590] 72
2 36700 [10.8] 13300 [3.9] 1600 [755] 72
1 - dehumid 26400 [7.7] 9800 [2.9] 1050 [495]
2 - dehumid 34300 [10.0] 14700 [4.3] 1350 [637]
RCFL-H*4821
RGFE-09?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11
1025 [484] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGFE-10?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11
1025 [484] 72
2 28400 [8.3] 16100 [4.7] 1425 [672] 72
RGFG-09?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11
1025 [484] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGFG-10?ZCM?
1 23800 [7.0] 14200 [4.2]
44500 [13.0] 15 11
1050 [495] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGGE-09?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11.5
1025 [484] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGGE-10?ZCM?
1 23800 [7.0] 14200 [4.2]
44500 [13.0] 15 11.5
1050 [495] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGJF-09?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11.5
1025 [484] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGJF-10?ZCM?
1 23800 [7.0] 14200 [4.2]
44500 [13.0] 15 11.5
1050 [495] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGLE-07?BRQ?
1 23700 [6.9] 14300 [4.2]
45000 [13.2] 15.5 11.5
1025 [484] 72
2 28700 [8.4] 16300 [4.8] 1400 [661] 72
RGLE-10?BRM?
1 24300 [7.1] 14200 [4.2]
45000 [13.2] 15.5 12
1050 [495] 72
2 28700 [8.4] 16300 [4.8] 1400 [661] 72
RGPE-07?BRQ?
1 23800 [7.0] 14200 [4.2]
45000 [13.2] 15.5 11.5
1050 [495] 72
2 28700 [8.4] 16300 [4.8] 1400 [661] 72
RGPE-10?BRM?
1 25700 [7.5] 13300 [3.9]
45500 [13.3] 15.5 11.5
1225 [578] 72
2 30400 [8.9] 15100 [4.4] 1625 [767] 72
RGRM-07?YBG?
1 23600 [6.9] 14200 [4.2]
43500 [12.7] 14 10.5
1050 [495] 72
2 27200 [8.0] 16300 [4.8] 1400 [661] 72
RGRM-09?ZAJ?
1 23900 [7.0] 14100 [4.1]
44500 [13.0] 15 11
1075 [507] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGRM-10?ZAJ?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11
1025 [484] 72
2 28400 [8.3] 16100 [4.7] 1425 [672] 72
RGTM-07?RBG?
1 24600 [7.2] 13900 [4.1]
45000 [13.2] 15 11.5
1125 [531] 72
2 29200 [8.6] 15800 [4.6] 1475 [696] 72
RGTM-09?ZAJ?
1 24500 [7.2] 14000 [4.1]
44500 [13.0] 15 11.5
1100 [519] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
ROCA-070E04
1 25000 [7.3] 13500 [4.0]
44500 [13.0] 14.5 11
1200 [566] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
ROLA-070E04
1 24800 [7.3] 13700 [4.0]
45000 [13.2] 15 11
1175 [554] 72
2 29900 [8.8] 15100 [4.4] 1600 [755] 72
ROLA-115E05
1 23800 [7.0] 14200 [4.2]
45000 [13.2] 15 11.5
1050 [495] 72
2 28700 [8.4] 16300 [4.8] 1400 [661] 72
RCFL-H*4821+RXMD-C06 Coil Only
1 25200 [7.4] 13300 [3.9]
45500 [13.3] 14 11
1250 [590] 72
2 30400 [8.9] 15100 [4.4] 1475 [696] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 21
21
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
049JEZ RCFL-H*4824
RGFE-09?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11
1025 [484] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGFE-10?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11
1025 [484] 72
2 28400 [8.3] 16100 [4.7] 1425 [672] 72
RGFE-12?RCM?
1 23700 [6.9] 14300 [4.2]
45000 [13.2] 15 11.5
1025 [484] 72
2 29000 [8.5] 16000 [4.7] 1450 [684] 72
RGFG-09?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11
1025 [484] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGFG-10?ZCM?
1 23800 [7.0] 14200 [4.2]
44500 [13.0] 15 11
1050 [495] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGFG-12?RCM?
1 23700 [6.9] 14300 [4.2]
45000 [13.2] 15 11.5
1025 [484] 72
2 29000 [8.5] 16000 [4.7] 1450 [684] 72
RGGE-09?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11.5
1025 [484] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGGE-10?ZCM?
1 23800 [7.0] 14200 [4.2]
44500 [13.0] 15 11.5
1050 [495] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGGE-12?RCM?
1 25500 [7.5] 13500 [4.0]
45500 [13.3] 15 11.5
1200 [566] 72
2 30400 [8.9] 15100 [4.4] 1575 [743] 72
RGJF-09?ZCM?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11.5
1025 [484] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGJF-10?ZCM?
1 23800 [7.0] 14200 [4.2]
44500 [13.0] 15 11.5
1050 [495] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGJF-12?RCM?
1 25500 [7.5] 13500 [4.0]
45000 [13.2] 15 11.5
1200 [566] 72
2 29900 [8.8] 15100 [4.4] 1575 [743] 72
RGLE-07?BRQ?
1 23700 [6.9] 14300 [4.2]
45000 [13.2] 15.5 11.5
1025 [484] 72
2 28700 [8.4] 16300 [4.8] 1400 [661] 72
RGLE-10?BRM?
1 24300 [7.1] 14200 [4.2]
45000 [13.2] 15.5 12
1050 [495] 72
2 28700 [8.4] 16300 [4.8] 1400 [661] 72
RGLE-12?ARM?
1 24400 [7.1] 14100 [4.1]
45000 [13.2] 15.5 12
1075 [507] 72
2 28900 [8.5] 16100 [4.7] 1425 [672] 72
RGPE-07?BRQ?
1 23800 [7.0] 14200 [4.2]
45000 [13.2] 15.5 11.5
1050 [495] 72
2 28700 [8.4] 16300 [4.8] 1400 [661] 72
RGPE-10?BRM?
1 25700 [7.5] 13300 [3.9]
45500 [13.3] 15.5 11.5
1225 [578] 72
2 30400 [8.9] 15100 [4.4] 1625 [767] 72
RGPE-12?ARM?
1 24400 [7.1] 14100 [4.1]
45000 [13.2] 15.5 12
1075 [507] 72
2 28900 [8.5] 16100 [4.7] 1425 [672] 72
RGRM-07?YBG?
1 23600 [6.9] 14200 [4.2]
43500 [12.7] 14 10.5
1050 [495] 72
2 27200 [8.0] 16300 [4.8] 1400 [661] 72
RGRM-09?ZAJ?
1 23900 [7.0] 14100 [4.1]
44500 [13.0] 15 11
1075 [507] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGRM-10?ZAJ?
1 23700 [6.9] 14300 [4.2]
44500 [13.0] 15 11
1025 [484] 72
2 28400 [8.3] 16100 [4.7] 1425 [672] 72
RGRM-12?RAJ?
1 23900 [7.0] 14100 [4.1]
45000 [13.2] 15 11.5
1075 [507] 72
2 28900 [8.5] 16100 [4.7] 1425 [672] 72
RGTM-07?RBG?
1 24600 [7.2] 13900 [4.1]
45000 [13.2] 15 11.5
1125 [531] 72
2 29200 [8.6] 15800 [4.6] 1475 [696] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 22
22
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
049JEZ
RCFL-H*4824
RGTM-09?ZAJ?
1 24500 [7.2] 14000 [4.1]
44500 [13.0] 15 11.5
1100 [519] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGTM-10?RBJ?
1 24600 [7.2] 13900 [4.1]
45000 [13.2] 15 11.5
1125 [531] 72
2 28900 [8.5] 16100 [4.7] 1425 [672] 72
ROCA-070E04
1 25000 [7.3] 13500 [4.0]
44500 [13.0] 14.5 11
1200 [566] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
ROLA-070E04
1 24800 [7.3] 13700 [4.0]
45000 [13.2] 15 11
1175 [554] 72
2 29900 [8.8] 15100 [4.4] 1600 [755] 72
ROLA-115E05
1 23800 [7.0] 14200 [4.2]
44500 [13.0] 15 11.5
1050 [495] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RCFL-H*4824+RXMD-C06 Coil Only
1 25200 [7.4] 13300 [3.9]
45500 [13.3] 14 11
1250 [590] 72
2 30400 [8.9] 15100 [4.4] 1425 [672] 72
RCFN-H*4824
RGFE-09?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12
1025 [484] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGFE-10?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12
1025 [484] 72
2 34000 [10.0] 14500 [4.2] 1425 [672] 72
RGFE-12?RCM?
1 27700 [8.1] 13300 [3.9]
49000 [14.4] 16.5 12.5
1025 [484] 72
2 34700 [10.2] 14300 [4.2] 1450 [684] 72
RGFG-09?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12
1025 [484] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGFG-10?ZCM?
1 27800 [8.1] 13200 [3.9]
48500 [14.2] 16 12
1050 [495] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGFG-12?RCM?
1 27700 [8.1] 13300 [3.9]
49000 [14.4] 16.5 12.5
1025 [484] 72
2 34700 [10.2] 14300 [4.2] 1450 [684] 72
RGGE-09?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12.5
1025 [484] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGGE-10?ZCM?
1 27800 [8.1] 13200 [3.9]
48500 [14.2] 16.5 12
1050 [495] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGGE-12?RCM?
1 29600 [8.7] 12400 [3.6]
49500 [14.5] 16.5 12.5
1200 [566] 72
2 36200 [10.6] 13300 [3.9] 1575 [743] 72
RGJF-09?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12.5
1025 [484] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGJF-10?ZCM?
1 27800 [8.1] 13200 [3.9]
48500 [14.2] 16.5 12
1050 [495] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGJF-12?RCM?
1 29600 [8.7] 12400 [3.6]
49500 [14.5] 16.5 12.5
1200 [566] 72
2 36200 [10.6] 13300 [3.9] 1575 [743] 72
RGLE-07?BRQ?
1 27700 [8.1] 13300 [3.9]
49000 [14.4] 16.5 12.5
1025 [484] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
RGLE-10?BRM?
1 27800 [8.1] 13200 [3.9]
49000 [14.4] 16.5 12.5
1050 [495] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
RGLE-12?ARM?
1 28500 [8.4] 13000 [3.8]
49000 [14.4] 16.5 12.5
1075 [507] 72
2 34500 [10.1] 14500 [4.2] 1425 [672] 72
RGPE-07?BRQ?
1 27800 [8.1] 13200 [3.9]
49000 [14.4] 16.5 12.5
1050 [495] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
RGPE-10?BRM?
1 28500 [8.4] 13000 [3.8]
49000 [14.4] 16.5 12.5
1075 [507] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 23
23
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
049JEZ
RCFN-H*4824
RGPE-12?ARM?
1 28500 [8.4] 13000 [3.8]
49000 [14.4] 16.5 12.5
1075 [507] 72
2 34500 [10.1] 14500 [4.2] 1425 [672] 72
RGRM-09?ZAJ?
1 28000 [8.2] 13000 [3.8]
49000 [14.4] 16 12
1075 [507] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
RGRM-10?ZAJ?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16 12
1025 [484] 72
2 34000 [10.0] 14500 [4.2] 1425 [672] 72
RGRM-12?RAJ?
1 28000 [8.2] 13000 [3.8]
48500 [14.2] 16.5 12.5
1075 [507] 72
2 34000 [10.0] 14500 [4.2] 1425 [672] 72
RGTM-07?RBG?
1 28700 [8.4] 12800 [3.8]
48500 [14.2] 16.5 12.5
1125 [531] 72
2 34400 [10.1] 14100 [4.1] 1475 [696] 72
RGTM-09?ZAJ?
1 28600 [8.4] 12900 [3.8]
48500 [14.2] 16.5 12.5
1100 [519] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGTM-10?RBJ?
1 28700 [8.4] 12800 [3.8]
49000 [14.4] 16.5 12.5
1125 [531] 72
2 34500 [10.1] 14500 [4.2] 1425 [672] 72
ROCA-070E04
1 29100 [8.5] 12400 [3.6]
48500 [14.2] 16 12
1200 [566] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
ROLA-070E04
1 29000 [8.5] 12500 [3.7]
49000 [14.4] 16 12
1175 [554] 72
2 35700 [10.5] 13300 [3.9] 1600 [755] 72
ROLA-115E05
1 27800 [8.1] 13200 [3.9]
48500 [14.2] 16.5 12.5
1050 [495] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RCFN-H*4824+RXMD-C06 Coil Only
1 29400 [8.6] 12100 [3.5]
49000 [14.4] 15 12
1250 [590] 72
2 35700 [10.5] 13300 [3.9] 1600 [755] 72
RCQD-4821
RGFE-09?ZCM?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 16 11.5
1025 [484] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGFE-10?ZCM?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 15.5 11.5
1025 [484] 72
2 32800 [9.6] 13700 [4.0] 1425 [672] 72
RGFG-09?ZCM?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 16 11.5
1025 [484] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGFG-10?ZCM?
1 28900 [8.5] 11600 [3.4]
47500 [13.9] 15.5 11.5
1200 [566] 72
2 35300 [10.3] 12200 [3.6] 1650 [779] 72
RGJF-09?ZCM?
1 27000 [7.9] 12500 [3.7]
47000 [13.8] 16 12
1025 [484] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RGJF-10?ZCM?
1 27600 [8.1] 12400 [3.6]
46500 [13.6] 16 12
1050 [495] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGPE-07?BRQ?
1 29600 [8.7] 11400 [3.3]
47500 [13.9] 16 12
1225 [578] 72
2 35000 [10.3] 12500 [3.7] 1600 [755] 72
RGPE-10?BRM?
1 29600 [8.7] 11400 [3.3]
47500 [13.9] 16 12
1225 [578] 72
2 35000 [10.3] 12500 [3.7] 1625 [767] 72
RGRM-09?ZAJ?
1 27700 [8.1] 12300 [3.6]
46500 [13.6] 15.5 11.5
1075 [507] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGRM-10?ZAJ?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 15.5 11.5
1025 [484] 72
2 32800 [9.6] 13700 [4.0] 1425 [672] 72
RGTM-07?RBG?
1 28000 [8.2] 12000 [3.5]
47000 [13.8] 16 12
1125 [531] 72
2 33600 [9.8] 13400 [3.9] 1475 [696] 72
RGTM-09?ZAJ?
1 27900 [8.2] 12100 [3.5]
47000 [13.8] 16 12
1100 [519] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 24
24
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
049JEZ
RCQD-4821
ROCA-070E04
1 28900 [8.5] 11600 [3.4]
46500 [13.6] 15.5 11.5
1200 [566] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
ROLA-070E04
1 27500 [8.1] 12500 [3.7]
47000 [13.8] 16 12
1025 [484] 72
2 33000 [9.7] 14000 [4.1] 1375 [649] 72
ROLA-115E05
1 27600 [8.1] 12400 [3.6]
47000 [13.8] 16 12
1050 [495] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RCQD-4821+RXMD-C06 Coil Only
1 28600 [8.4] 11400 [3.3]
47500 [13.9] 14.5 11.5
1250 [590] 72
2 35000 [10.3] 12500 [3.7] 1550 [731] 72
RCQD-4824
RBHM-25J
1 29400 [8.6] 11600 [3.4]
48500 [14.2] 16.5 13
1200 [566] 72
2 36000 [10.5] 12500 [3.7] 1600 [755] 72
RGFE-09?ZCM?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 16 12
1025 [484] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGFE-10?ZCM?
1 27000 [7.9] 12500 [3.7]
47000 [13.8] 16 12
1025 [484] 72
2 33300 [9.8] 13700 [4.0] 1425 [672] 72
RGFE-12?RCM?
1 27500 [8.1] 12500 [3.7]
47000 [13.8] 16 12
1025 [484] 72
2 33400 [9.8] 13600 [4.0] 1450 [684] 72
RGFG-09?ZCM?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 16 12
1025 [484] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGFG-10?ZCM?
1 27600 [8.1] 12400 [3.6]
46500 [13.6] 16 12
1050 [495] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGFG-12?RCM?
1 27500 [8.1] 12500 [3.7]
47000 [13.8] 16 12
1025 [484] 72
2 33400 [9.8] 13600 [4.0] 1450 [684] 72
RGJF-09?ZCM?
1 27500 [8.1] 12500 [3.7]
47000 [13.8] 16 12
1025 [484] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RGJF-10?ZCM?
1 27600 [8.1] 12400 [3.6]
47000 [13.8] 16 12
1050 [495] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RGJF-12?RCM?
1 28900 [8.5] 11600 [3.4]
48000 [14.1] 16 12
1200 [566] 72
2 35500 [10.4] 12500 [3.7] 1575 [743] 72
RGPE-07?BRQ?
1 27600 [8.1] 12400 [3.6]
47000 [13.8] 16 12.5
1050 [495] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RGPE-10?BRM?
1 27700 [8.1] 12300 [3.6]
47000 [13.8] 16.5 12
1075 [507] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RGPE-12?ARM?
1 27700 [8.1] 12300 [3.6]
47500 [13.9] 16.5 12.5
1075 [507] 72
2 33800 [9.9] 13700 [4.0] 1425 [672] 72
RGRM-09?ZAJ?
1 27700 [8.1] 12300 [3.6]
46500 [13.6] 15.5 11.5
1075 [507] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGRM-10?ZAJ?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 16 11.5
1025 [484] 72
2 32800 [9.6] 13700 [4.0] 1425 [672] 72
RGRM-12?RAJ?
1 27700 [8.1] 12300 [3.6]
47000 [13.8] 16 12
1075 [507] 72
2 33300 [9.8] 13700 [4.0] 1425 [672] 72
RGTM-07?RBG?
1 30200 [8.8] 11100 [3.3]
48500 [14.2] 15.5 11.5
1325 [625] 72
2 36200 [10.6] 12200 [3.6] 1675 [790] 72
RGTM-09?ZAJ?
1 27900 [8.2] 12100 [3.5]
47000 [13.8] 16 12
1100 [519] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RGTM-10?RBJ?
1 28500 [8.4] 12000 [3.5]
47000 [13.8] 16 12
1125 [531] 72
2 33300 [9.8] 13700 [4.0] 1425 [672] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 25
25
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
049JEZ
RCQD-4824
ROCA-070E04
1 28900 [8.5] 11600 [3.4]
46500 [13.6] 15.5 11.5
1200 [566] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
ROLA-070E04
1 28700 [8.4] 11800 [3.5]
47500 [13.9] 16 11.5
1175 [554] 72
2 35000 [10.3] 12500 [3.7] 1600 [755] 72
ROLA-115E05
1 27600 [8.1] 12400 [3.6]
47000 [13.8] 16 12
1050 [495] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RCQD-4824+RXMD-C06 Coil Only
1 28600 [8.4] 11400 [3.3]
47500 [13.9] 14.5 11.5
1250 [590] 72
2 35000 [10.3] 12500 [3.7] 1600 [755] 72
RCSL-H*4824 RHPL-HM4824
1 26200 [7.7] 13300 [3.9]
46000 [13.5] 16 12
1250 [590] 72
2 30900 [9.1] 15100 [4.4] 1625 [767] 72
061JEZ
RCSN-H*6024
RHPN-HM6024
1 34100 [10.0] 14900 [4.4]
59000 [17.3] 16 13
1325 [625] 76
2 42700 [12.5] 16300 [4.8] 1775 [838] 78
1 - dehumid 29000 [8.5] 12500 [3.7] 1050 [495]
2 - dehumid 39300 [11.5] 18200 [5.3] 1450 [684]
RCFL-H*6024
RGFE-09?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGFE-10?ZCM?
1 32400 [9.5] 15600 [4.6]
57000 [16.7] 16 12
1225 [578] 76
2 39200 [11.5] 17800 [5.2] 1600 [755] 78
RGFE-12?RCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39900 [11.7] 17600 [5.2] 1625 [767] 78
RGFG-09?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGFG-10?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 40100 [11.7] 17400 [5.1] 1650 [779] 78
RGFG-12?RCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39900 [11.7] 17600 [5.2] 1625 [767] 78
RGGE-09?ZCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGGE-10?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGGE-12?RCM?
1 34400 [10.1] 14600 [4.3]
58500 [17.1] 16 12
1375 [649] 76
2 42100 [12.3] 16400 [4.8] 1750 [826] 78
RGJF-09?ZCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGJF-10?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGJF-12?RCM?
1 34400 [10.1] 14600 [4.3]
58500 [17.1] 16 12
1375 [649] 76
2 42100 [12.3] 16400 [4.8] 1750 [826] 78
RGLE-07?BRQ?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12.5
1225 [578] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGLE-10?BRM?
1 32800 [9.6] 15700 [4.6]
58000 [17.0] 16 12.5
1200 [566] 76
2 40200 [11.8] 17800 [5.2] 1600 [755] 78
RGLE-12?ARM?
1 32900 [9.6] 15600 [4.6]
58000 [17.0] 16 12.5
1225 [578] 76
2 40200 [11.8] 17800 [5.2] 1600 [755] 78
RGPE-07?BRQ?
1 32900 [9.6] 15600 [4.6]
58000 [17.0] 16 12.5
1225 [578] 76
2 40200 [11.8] 17800 [5.2] 1600 [755] 78
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 26
26
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
061JEZ
RCFL-H*6024
RGPE-10?BRM?
1 32900 [9.6] 15600 [4.6]
58000 [17.0] 16 12.5
1225 [578] 76
2 40400 [11.8] 17600 [5.2] 1625 [767] 78
RGPE-12?ARM?
1 32800 [9.6] 15700 [4.6]
58000 [17.0] 16 12.5
1200 [566] 76
2 40400 [11.8] 17600 [5.2] 1625 [767] 78
RGRM-07?YBG?
1 31800 [9.3] 15700 [4.6]
56000 [16.4] 15 11
1200 [566] 76
2 38000 [11.1] 18000 [5.3] 1575 [743] 78
RGRM-09?ZAJ?
1 32400 [9.5] 15600 [4.6]
57000 [16.7] 15.5 11.5
1225 [578] 76
2 39400 [11.5] 17600 [5.2] 1625 [767] 78
RGRM-10?ZAJ?
1 31500 [9.2] 16000 [4.7]
57000 [16.7] 16 11.5
1150 [543] 76
2 39200 [11.5] 17800 [5.2] 1600 [755] 78
RGRM-12?RAJ?
1 32400 [9.5] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39900 [11.7] 17600 [5.2] 1625 [767] 78
RGTM-07?RBG?
1 34100 [10.0] 14900 [4.4]
58000 [17.0] 16 12
1325 [625] 76
2 40800 [12.0] 17200 [5.0] 1675 [790] 78
RGTM-09?ZAJ?
1 33100 [9.7] 15400 [4.5]
57500 [16.8] 16 12
1250 [590] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGTM-10?RBJ?
1 33200 [9.7] 15300 [4.5]
58000 [17.0] 16 12.5
1275 [602] 76
2 40800 [12.0] 17200 [5.0] 1675 [790] 78
ROCA-070E04
1 32300 [9.5] 15700 [4.6]
56500 [16.6] 16 12
1200 [566] 76
2 37100 [10.9] 19400 [5.7] 1400 [661] 78
ROLA-070E04
1 32100 [9.4] 15900 [4.7]
57500 [16.8] 16 12
1175 [554] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
ROLA-115E05
1 32800 [9.6] 15700 [4.6]
57500 [16.8] 16 12.5
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RCFL-H*6024+RXMD-C06 Coil Only
1 33100 [9.7] 14900 [4.4]
58000 [17.0] 15 12
1325 [625] 76
2 40800 [12.0] 17200 [5.0] 1675 [790] 78
RCFN-H*6024
RGFE-09?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGFE-10?ZCM?
1 32400 [9.5] 15600 [4.6]
57000 [16.7] 16 12
1225 [578] 76
2 39200 [11.5] 17800 [5.2] 1600 [755] 78
RGFE-12?RCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39900 [11.7] 17600 [5.2] 1625 [767] 78
RGFG-09?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGFG-10?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 40100 [11.7] 17400 [5.1] 1650 [779] 78
RGFG-12?RCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39900 [11.7] 17600 [5.2] 1625 [767] 78
RGGE-10?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGGE-12?RCM?
1 34400 [10.1] 14600 [4.3]
58500 [17.1] 16 12
1375 [649] 76
2 42200 [12.4] 16300 [4.8] 1750 [826] 78
RGJF-09?ZCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGJF-10?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 27
27
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
061JEZ
RCFN-H*6024
RGJF-12?RCM?
1 34400 [10.1] 14600 [4.3]
58500 [17.1] 16 12
1375 [649] 76
2 42200 [12.4] 16300 [4.8] 1750 [826] 78
RGLE-07?BRQ?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12.5
1225 [578] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGLE-10?BRM?
1 32800 [9.6] 15700 [4.6]
58000 [17.0] 16 12.5
1200 [566] 76
2 40200 [11.8] 17800 [5.2] 1600 [755] 78
RGLE-12?ARM?
1 32900 [9.6] 15600 [4.6]
58000 [17.0] 16 12.5
1225 [578] 76
2 40200 [11.8] 17800 [5.2] 1600 [755] 78
RGLR-07?BRQ?
1 32900 [9.6] 15600 [4.6]
58000 [17.0] 16 12.5
1225 [578] 76
2 40400 [11.8] 17600 [5.2] 1625 [767] 78
RGPE-07?BRQ?
1 32900 [9.6] 15600 [4.6]
58000 [17.0] 16 12.5
1225 [578] 76
2 40200 [11.8] 17800 [5.2] 1600 [755] 78
RGPE-10?BRM?
1 32900 [9.6] 15600 [4.6]
58000 [17.0] 16 12.5
1225 [578] 76
2 40400 [11.8] 17600 [5.2] 1625 [767] 78
RGPE-12?ARM?
1 32800 [9.6] 15700 [4.6]
58000 [17.0] 16 12.5
1200 [566] 76
2 40400 [11.8] 17600 [5.2] 1625 [767] 78
RGRM-10?ZAJ?
1 31500 [9.2] 16000 [4.7]
57000 [16.7] 16 11.5
1150 [543] 76
2 39200 [11.5] 17800 [5.2] 1600 [755] 78
RGRM-12?RAJ?
1 32400 [9.5] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39900 [11.7] 17600 [5.2] 1625 [767] 78
RGTM-09?ZAJ?
1 33100 [9.7] 15400 [4.5]
57500 [16.8] 16 12
1250 [590] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
ROCA-070E04
1 34000 [10.0] 14500 [4.2]
57000 [16.7] 15 12
1400 [661] 76
2 39200 [11.5] 17800 [5.2] 1600 [755] 78
ROLA-070E04
1 32100 [9.4] 15900 [4.7]
57500 [16.8] 16 12
1175 [554] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
ROLA-115E05
1 32800 [9.6] 15700 [4.6]
57500 [16.8] 16 12.5
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RCFN-H*6024+RXMD-C06 Coil Only
1 33100 [9.7] 14900 [4.4]
58000 [17.0] 15 12
1325 [625] 76
2 40800 [12.0] 17200 [5.0] 1675 [790] 78
RCQD-6024
RBHM-25J
1 30400 [8.9] 15100 [4.4]
54500 [16.0] 15.5 12.5
1200 [566] 76
2 37400 [11.0] 17100 [5.0] 1600 [755] 78
RBHM-26J
1 30900 [9.1] 14600 [4.3]
55000 [16.1] 16 12.5
1275 [602] 76
2 38700 [11.3] 16300 [4.8] 1700 [802] 78
RGFE-09?ZCM?
1 29900 [8.8] 15100 [4.4]
53500 [15.7] 14.5 11.5
1200 [566] 76
2 36400 [10.7] 17100 [5.0] 1600 [755] 78
RGFE-10?ZCM?
1 30100 [8.8] 14900 [4.4]
53000 [15.5] 14.5 11
1225 [578] 76
2 35900 [10.5] 17100 [5.0] 1600 [755] 78
RGFE-12?RCM?
1 30100 [8.8] 14900 [4.4]
53500 [15.7] 15 11.5
1225 [578] 76
2 36600 [10.7] 16900 [5.0] 1625 [767] 78
RGFG-09?ZCM?
1 29900 [8.8] 15100 [4.4]
53500 [15.7] 14.5 11.5
1200 [566] 76
2 36400 [10.7] 17100 [5.0] 1600 [755] 78
RGFG-10?ZCM?
1 29900 [8.8] 15100 [4.4]
53500 [15.7] 14.5 11.5
1200 [566] 76
2 36800 [10.8] 16700 [4.9] 1650 [779] 78
RGFG-12?RCM?
1 30100 [8.8] 14900 [4.4]
53500 [15.7] 15 11.5
1225 [578] 76
2 36600 [10.7] 16900 [5.0] 1625 [767] 78
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 28
28
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
061JEZ
RCQD-6024
RGJF-09?ZCM?
1 30100 [8.8] 14900 [4.4]
53500 [15.7] 15 11.5
1225 [578] 76
2 36400 [10.7] 17100 [5.0] 1600 [755] 78
RGJF-10?ZCM?
1 29900 [8.8] 15100 [4.4]
53500 [15.7] 15 11.5
1200 [566] 76
2 36400 [10.7] 17100 [5.0] 1600 [755] 78
RGJF-12?RCM?
1 31900 [9.3] 14100 [4.1]
54500 [16.0] 15 11.5
1375 [649] 76
2 38800 [11.4] 15700 [4.6] 1750 [826] 78
RGPE-07?BRQ?
1 30100 [8.8] 14900 [4.4]
54000 [15.8] 15 12
1225 [578] 76
2 36900 [10.8] 17100 [5.0] 1600 [755] 78
RGPE-10?BRM?
1 30100 [8.8] 14900 [4.4]
54000 [15.8] 15 12
1225 [578] 76
2 37100 [10.9] 16900 [5.0] 1625 [767] 78
RGPE-12?ARM?
1 29900 [8.8] 15100 [4.4]
54000 [15.8] 15.5 12
1200 [566] 76
2 37100 [10.9] 16900 [5.0] 1625 [767] 78
RGRM-07?YBG?
1 29400 [8.6] 15100 [4.4]
52000 [15.2] 13.5 10
1200 [566] 76
2 34800 [10.2] 17200 [5.0] 1575 [743] 78
RGRM-09?ZAJ?
1 30100 [8.8] 14900 [4.4]
53000 [15.5] 14.5 11
1225 [578] 76
2 36100 [10.6] 16900 [5.0] 1625 [767] 78
RGRM-10?ZAJ?
1 29200 [8.6] 15300 [4.5]
53000 [15.5] 14.5 11
1150 [543] 76
2 35900 [10.5] 17100 [5.0] 1600 [755] 78
RGRM-12?RAJ?
1 30100 [8.8] 14900 [4.4]
53500 [15.7] 15 11.5
1225 [578] 76
2 36600 [10.7] 16900 [5.0] 1625 [767] 78
RGTM-07?RBG?
1 31100 [9.1] 14400 [4.2]
54000 [15.8] 14.5 11.5
1325 [625] 76
2 37500 [11.0] 16500 [4.8] 1675 [790] 78
RGTM-09?ZAJ?
1 30200 [8.8] 14800 [4.3]
53500 [15.7] 15 11.5
1250 [590] 76
2 36400 [10.7] 17100 [5.0] 1600 [755] 78
RGTM-10?RBJ?
1 30900 [9.1] 14600 [4.3]
54000 [15.8] 15 11.5
1275 [602] 76
2 37500 [11.0] 16500 [4.8] 1675 [790] 78
ROCA-070E04
1 31600 [9.3] 13900 [4.1]
53000 [15.5] 14 11
1400 [661] 76
2 35900 [10.5] 17100 [5.0] 1600 [755] 78
ROLA-070E04
1 29800 [8.7] 15200 [4.5]
53500 [15.7] 15 11.5
1175 [554] 76
2 36400 [10.7] 17100 [5.0] 1600 [755] 78
ROLA-115E05
1 29900 [8.8] 15100 [4.4]
53500 [15.7] 15 11.5
1200 [566] 76
2 36400 [10.7] 17100 [5.0] 1600 [755] 78
RCQD-6024+RXMD-C06 Coil Only
1 30600 [9.0] 14400 [4.2]
54500 [16.0] 14 11.5
1325 [625] 76
2 38800 [11.4] 15700 [4.6] 1775 [838] 78
RCSL-H*6024 RHPL-HM6024
1 35000 [10.3] 14500 [4.2]
59000 [17.3] 16 13
1400 [661] 76
2 41900 [12.3] 17100 [5.0] 1700 [802] 78
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Page 29
29
Model
Number
RARL
ELECTRICAL PHYSICAL
Phase
Frequency (Hz)
Voltage (Volts)
Compressor
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit Ampacity Amperes
Fuse or HACR
Circuit Breaker
Outdoor Coil
Refrig.
Per Circuit Oz. [g]
Weight
Rated Load
Amperes
(RLA)
Locked Rotor
Amperes
(LRA)
Minimum Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM [L/s]
Net
Lbs. [kg]
Shipping Lbs. [kg]
Rev. 5/8/2012
025JEZ 1-60-208/230 11.7/11.7 58.3 0.75 16/16 20/20 25/25 15.82 [1.47] 1 2285 [1078] 104 [2948] 197 [89.4] 210 [89.4]
038JEZ 1-60-208/230 15.3/15.3 83 1 21/21 25/25 35/35 23.01 [2.14] 1 3400 [1604] 186 [5273] 216 [98] 229 [98]
049JEZ 1-60-208/230 21.2/21.2 104 1 28/28 35/35 45/45 23.01 [2.14] 1 3400 [1604] 180 [5103] 252 [114.3] 265 [120.2]
061JEZ 1-60-208/230 28.8/28.8 152.9 2.8 39/39 50/50 60/60 23.01 [2.14] 2 3500 [1652] 243 [6889] 283 [128.4] 296 [128.4]
NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set.
[ ] Designates Metric Conversions
Electrical and Physical Data
Air
Electrical and Physical Data
RARL- JEZ Series
Page 30
Unit Dimensions
Model Number
RARL-
Height “H”
(Inches) [mm]
Length “L”
(Inches) [mm]
Width “W”
(Inches) [mm]
025JEZ 23 [584] 443/8 [1127] 311/2 [800]
038JEZ/049JEZ/061JEZ 33 [838] 443/8 [1127] 311/2 [800]
[ ] Designates Metric Conversions
Air
Unit Dimensions
RARL- JEZ Series
30
ACCESS PANEL
AIR DISCHARGE
ALLOW 60 [1524 mm] CLEARANCE
L
ALLOW 24 [610 mm] ACCESS CLEARANCE
W
ALTERNATE HIGH VOLTAGE CONNECTION (KNOCKOUT)
11
/32[34 mm]
1
H
AIR INLETS (LOUVERS) ALLOW 6 [152 mm] MIN. CLEARANCE 3 SIDES
SERVICE FITTINGS
3
0
0
0
0
-
A
HIGH PRESSURE CONTROL MANUAL RESET (FIELD INSTALLED ACCESSORY)
VAPOR LINE CONNECTION
LOW VOLTAGE CONNECTION
7
/80 [22 mm]
LIQUID LINE CONNECTION
7
/80 [73 mm] DIA.
2 ACCESSORY KNOCKOUTS
HIGH VOLTAGE CONNECTION
11
/320 [34 mm]
1
SERVICE ACCESS TO ELECTRICAL & VALVES ALLOW 240 [610 mm] CLEARANCE ONE SIDE
Page 31
Air
Refrigerant Line Size Information
RARL- JEZ Series
Suction Line Run
Feet [m]
25'
[7.62]
50'
[15.24]
100'
[30.48]
150'
[45.72]
Optional Standard Optional
Optional Standard Optional
Optional Standard Optional
Optional Standard Optional
5
/8"[15.88 mm]O.D. Std.*
3
/4" [19.05 mm]O.D. Opt.
1.00
1.00
0.99
1.00
0.97
0.98
0.95
0.97
Suction Line Length/Size and Capacity Multiplier
2-Stage R-410A
System Capacity Model
2 To n 3 To n
5
/8"[15.88 mm]O.D. Opt.
3
/4" [19.05 mm]O.D. Std.*
.99
1.00 N/A
0.98
0.99
N/A
0.95
0.97
N/A
0.91
0.95
N/A
4 Ton
3
/4" [19.05 mm]O.D. Opt.
7
/8" [22.23 mm]O.D. Std.*
1.00
1.00 N/A
0.98
0.99
N/A
0.95
0.97
N/A
0.93
0.95
N/A
5 Ton
.99
1.00 N/A
0.98
0.99
N/A
0.94
0.97
N/A
0.91
0.95
N/A
Suction Line Connection Size 3/4" [19.05] I.D. 7/8" [22.23] I.D.
2-Stage R-410A System
Capacity
Model
Line Size
(Inch O.D.)
[mm]
Liquid Line Size
Outdoor unit above Indoor Coil (Cooling Only)
Liquid Line Size
Outdoor unit Below Indoor Coil (Cooling Only)
Minimum Vertical Separation—Feet [m] Maximum Vertical Separation—Feet [m]
25
[7.62]50[15.24]75[22.86]
100
[30.48]
125
[38.10]
150
[45.72]25[7.62]50[15.24]75[22.86]
100
[30.48]
125
[38.10]
150
[45.72]
Total Equivalent Length—Feet [m] Total Equivalent Length—Feet [m]
5/16 [7.94] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 40 [12.19] 35 [10.66] 29 [8.83] 22 [6.70]
2 Ton
1/4* [6.35] 0 0 17 [5.18] 43 [13.10] 70 [21.33] 95 [28.95] 25 [7.62] 10 [3.04] N/A N/A N/A N/A
5/16
[7.94]
Liquid Line
Connection
Size
(Inch I.D.)
3/8 [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 51 [15.54] 48 [14.63] 44 [13.41] 40 [12.19]
3 Ton
5/16* [7.94] 0 0 0 0 0 7 25 [7.62] 39 [11.88] 28 [8.53] 16 [4.87] 5 [1.52] N/A
5/16
[7.94]
3/8 [9.53] 0 0 0 0 0 0 25 [7.62] 47 [14.32] 40 [12.19] 32 [9.75] 24 [7.31] 17 [5.18]
4 Ton
5/16* [7.94] 0 0 8 [2.43] 32 [9.75] 55 [16.76] 80 [24.38] 25 [7.62] 15 [4.57] N/A N/A N/A N/A
3/8
[9.53]
1/2 [12.7] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 56 [17.06] 54 [16.45] 52 [15.84] 50 [15.24]
5 Ton
3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 41 [12.49] 30 [9.14] 20 [6.09] 10 [3.04] 0
3/8
[9.53]
3/8 [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 45 [13.71] 42 [12.80] 39 [11.88] 37 [11.28]
NOTES: N/A = Application not recommended.
*Standard line size
NOTES: Line size not recommended due to inadequate oil return.
*Standard line size
[ ] Designates Metric Conversions
Condensing Unit Refrigerant Line Size Information
31
Page 32
Air
Limited Warranty
RARL- JEZ Series
32
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including
applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Unit Replacement
(Registration Required)...............................Ten (10) Years
Parts............................................................Ten (10) Years
Page 33
Air
Notes
RARL- JEZ Series
33
Page 34
Air
Notes
RARL- JEZ Series
34
Page 35
Air
Notes
RARL- JEZ Series
35
Page 36
The new degree of comfort.
Rheem Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.rheem.com
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A 06/12 QG FORM NO. A11-213