Rheem Prestige High Efficiency Condensing Power Direct Specification

T
INTEGRATED HOME COMFORT
Prestige™ High Efficiency Condensing Power
INTEGRATED HOME COMFORT
Direct Vent induced draft gas water heater is a perfect choice when indoor air quality is a concern
Water
Residential Gas
High Efficiency Condensing Power Direct Vent Water Heaters
Efficiency
• 0.80 EF exceeds ENERGY STAR® Phase II requirements, Sept. 2010
®
• Complies with the ENERGY STAR for New Homes standard (ESNH), version 12.2
• Low operating costs: $228 annually for natural gas models
Performance
• FHR: Up to 93-gallons for natural and LP gas
• Recovery: 43.6 to 48.5 at a 90° F rise
Self-Diagnostic System
• Integrated system control for easy installation and service
• Diagnostic system control can be replaced without draining the water heater
Low Emissions
• Eco-friendly burner, low NOx design
Features
• Power direct vents are an ideal choice when either indoor air quality or negative air pressure are concerns
• Two-pipe system: one pipe pulls in outside air for combustion and the other exhausts combustion gases
• 120 VAC, 60Hz, induced draft blower
• New whisper quiet blower
Innovative Technology
• Proven center ue design with submerged coil type condensing heat exchanger
• Heat exchanger is porcelain coated inside and out for increased product life
Flammable Vapor Detection System
• FVIR compliant protective
• Control system that disables the heater in the presence of ammable vapor accumulation
Flexible Venting Options
• Long venting lengths up to 60 feet
• Use 2 or 3 inch diameter PVC, or CPVC certied to ULC-S636 vent pipe options
• Vertical or horizontal termination
• Concentric vent kit available
• Flat termination available
Longer Life
• Dual anode rods protect the tank from corrosion
High Altitude Compliant
Models are certied for applications up to 9,000 feet above sea level
Plus…
• Brass drain valve and temperature and pressure relief valve are included
• Durable silicon nitride igniter (HSI)
• Inlet tube with diffuser enhances heat transfer
• Front access to condensate trap and vent pipe
• Condensate neutralizer option
• Standard replacement parts
Warranty
• 6
-Year limited tank and parts warranty*
* See Residential Warranty Certicate for
complete information
Prestige High Efficiency
Condensing
Power Direct Vent
Induced Draft
38 and 48-Gallon Capacities
Up to 40,000 Btu/h Natural and LP Gas
LEED Points = 2
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 03/14 WP FORM NO. RHE-101CAN Rev. 3
T
INTEGRATED HOME COMFORT
INTEGRATED HOME COMFORT
Residential Gas
Water
High Efficiency Condensing Power Direct Vent Water Heaters
Prestige High Efficiency Condensing Power Direct Vent Specifications
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T Y
GAL. MODEL
P E
CAP. NUMBER NAT. LP NAT. LP NAT. LP A B C D E F G H I (LBS) NAT. LP NAT.
38 CN RHE40S 40 36 48.5 43.6 74 74 62-3/8 61-3/8 51-1/16 22-1/8 14-1/8 8 44-1/4 3/4 26-11/16 220 0.80 0.80 $228
SHORT
TALL
48 CN RHE50 40 36 48.5 43.6 93 93 71 69-5/8 59-11/16 22-1/8 14-1/8 8 52-7/8 3/4 26-11/16 250 0.80 0.80 $228
Specify LP gas when ordering. Add “P” sufx to the model number. Example CN RHE50P. Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate natural gas $1.218/therm; LP $1.87/gallon.
GAS INPUT IN RECOVERY IN FIRST HOUR
THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H.
HT. TO HT. TO HT. TO WATER HT. TO WATER FRONT AVG.
TOP OF TOP OF TANK GAS CONN. SIDE T&P CONN. TO SHIP.
VENT AIR INLET HT. DIAM. CONN. CNTR. VALVE SIZE BACK WT.
ENERGY FACTOR
ANN. OPER. COSTS
T&P FITTING
3/4" NPT
D
1/2"
COMBUSTION
AIR INLET
COMBUSTION
EXHAUST (VENT)
HOT WATER
CONNECTION
H
H COLD WATER CONNECTION
I
BA C G
E
F
Air-Inlet and Venting Information for CN RHE40S and CN RHE50
From Sea Level Through 5,999 ft. Above Sea Level
Vent & Combustion Minimum Allowed Maximum Allowed Vent
Air-Inlet Equivalent Vent & Combustion Equivalent Vent & Combustion and Combustion Pipe Diameter Air-Inlet Lengths – Air-Inlet Lengths – Air-Inlet System
Model (Inches) Each Pipe Run (Ft.) Each Pipe Run (Ft.) Termination(s)
CN RHE40S 2 7 30 90° Elbows Concentric*
CN RHE40S 3 7 60 90° Elbows Concentric*
CN RHE50 2 7 30 90° Elbows Concentric*
CN RHE50 3 7 60 90° Elbows Concentric*
From 6,000 ft. Above Sea Level Through 8,999 ft. Above Sea Level
Vent & Combustion Minimum Allowed Maximum Allowed Vent
Air-Inlet Equivalent Vent & Combustion Equivalent Vent & Combustion and Combustion Pipe Diameter Air-Inlet Lengths – Air-Inlet Lengths – Air-Inlet System
Model (Inches) Each Pipe Run (Ft.) Each Pipe Run (Ft.) Termination(s)
CN RHE40S 2 Not Allowed Not Allowed
CN RHE40S 3 7 45 90° Elbows Concentric*
CN RHE50 2 Not Allowed Not Allowed
CN RHE50 3 7 45 90° Elbows Concentric*
One 90° elbow is equivalent to 5 feet of straight pipe. One 45° elbow is equivalent to 2.5 feet of straight pipe. The vent and combustion air inlet terminations are not included in the equivalency calculations. * Use only Rheem 3 inch concentric termination kit SP20245.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5 • www.rheem.com
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 03/14 WP FORM NO. RHE-101CAN Rev. 3