Rheem Prestige Specification

Rheem Prestige™Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace
FORM NO. G11-546 REV. 1
R802V- Upflow/Horizontal Series
Air
Gas Furnaces
R802V (UF/HZ) Series
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
80% residential Gas Furnace CSA certified
Two stages of operation to save energy and maintain optimal
comfort level.
Variable speed blower motor technology provides ultimate
humidity control quieter sound levels and year round energy savings
EcoNet enabled HVAC product
3 way multi poise design UF / HZ
PlusOne
Diagnostics — 7 Segment LED all units
PlusOne
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability.
Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability.
Solid doors provide quiet operation
Solid bottom
Insulated blower compartment
Low profile 34" cabinet ideal for space constrained
installations
Blower shelf design – serviceable in all furnace orientations
Hemmed edges on cabinets and doors
1/4 turn door knobs for tool less access
Integrated Control board features dip switches for easy
system set up
QR code for quick access to product information from your
smart phone or tablet
Compatible with single or two stage thermostats. For optimal
performance a two stage thermostat is recommended.
Air
Table of Contents
R802V (UF/HZ) Series
2
TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Model Features/Physical Data & Specifications..................................................4
Model Number Identification ............................................................................5
Dimensional Data ........................................................................................6-7
Blower Performance Data ................................................................................8
Accessories....................................................................................................9
Limited Warranty ..........................................................................................10
Air
Standard & Optional Equipment
R802V (UF/HZ) Series
3
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
DIRECT SPARK IGNITOR
IN-SHOT BURNERS
DRAFT INDUCER MOTOR
PATENTED HEAT EXCHANGER
INTEGRATED FURNACE CONTROL
STANDARD EQUIPMENT
Completely assembled and wired; 2 speed induced draft blower; high and low pressure switches; 2 stage redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; transformer; ECM blower motor. Furnaces are equipped with cooling/heating relay and transformer (50VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; fused­protection (secondary), 3rd speed option for continuous fan.
OPTIONAL EQUIPMENT
Side and bottom filter frame assembly. 4" Flue Adapter NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
The complete terms of limited and other warranties are available at our sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, direct spark ignition
is 100% safety lockout type.
ECM MOTOR
Air
Model Features/Physical Data & Specifications
R802V (UF/HZ) Series
4
MODEL NUMBERS R802V SERIES R802VA050317M*A R802VA075317M*A R802VA075421M*A R802VA100521M*A R802VA125524M*A
High Input-BTU/Hr [kW]
50,000 [15] 75,000 [22] 75,000 [22] 100,000 [29] 125,000 [37]
Heating Capacity BTU/Hr [kW]
40,000 [12] 60,000 [18] 60,000 [18] 80,000 [23] 100,000 [29]
Low Input BTU/Hr [kW]
35,000 [10] 52,500 [15] 52,500 [15] 70,000 [20] 87,500 [25]
Heating Capacity BTU/Hr [kW]
28,000 [8] 42,000 [12] 42,000 [12] 56,000 [16] 70,000 [20]
Heat Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .12 [.029] .15 [.037] .20 [.05]
Blower (D x W) [mm]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
Motor H.P. Type [W]
1
/2 ECM
[373]
1
/2 ECM
[373]
3
/4 ECM
[560]
3
/4 ECM
[560]
3
/4 ECM
[560] Motor Full Load Amps 7.7 7.7 9.6 9.6 9.6 Cooling CFM @ Rating Point
[L/s]
1250 [590]
1650 [780]
1800 [850]
1750 [825]
1900
[900] Max. E.S.P. (In. W.C.) [kPa] 1.0 [.249] 1.0 [.249] 1.0 [.249] 1.0 [.249] 1.0 [.249] Temperature Rise Range °F
[°C]–High Input
25-55
[13.9-30.6]
25-55
[13.9-30.6]
25-55
[13.9-30.6]
35-65
[19.4-36.1]
35-65
[19.4-36.1]
Temperature Rise Range °F [°C]–Low Input
20-50
[12.8-29.4]
20-50
[12.8-29.4]
20-50
[12.8-29.4]
30-60
[18.3-35]
30-60
[18.3-35]
Max. Outlet Air Temp. °F [°C]
155
[68.3]
155
[68.3]
165
[73.8]
180
[82.2]
180
[82.2]
Approx. Shipping Weight (Lbs.) [kg]
125 [57]
125 [57]
140 [64]
140 [64]
150
[68]
AFUE
80.0% 80.0% 80.0% 80.0% 80.0%
NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is 1/2" [12 mm] N.P.T.
In accordance with D.O.E. test procedures.See Conversion Kit Index Form for high altitude derate.
* S = Standard, X = Low Nox
[ ] Designates Metric Conversions
80% residential Gas Furnace CSA certified
Two stages of operation to save energy and maintain optimal comfort level.
Variable speed blower motor technology provides ultimate humidity control quieter sound levels and year round energy savings
EcoNet enabled HVAC product
3 way multi poise design UF / HZ
PlusOne
Diagnostics — 7 Segment LED all units
PlusOne
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability.
Solid doors provide quiet operation
Solid bottom
Insulated blower compartment
Low profile 34" cabinet ideal for space constrained installations
Blower shelf design serviceable in all furnace orientations
Hemmed edges on cabinets and doors
1/4 turn door knobs for tool less access
Integrated Controls board features dip switches for easy system set up
QR code for quick access to product information from your smart phone or tablet
Compatible with single or two stage thermostats. For optimal performance a two stage thermostat is recommended.
Model Features
Physical Data and Specifications
R
80 2 V A
075
4 17 M S A
Rheem 80 =
80% AFUE
2 = Two Stage V = Variable
Speed ECM
Design Series
A = 1st Design
Input
BTU/HR [kW]
050 = 50,000 [15] 075 = 75,000 [22] 100 = 100,000 [29] 125 = 125,000 [37]
3 = Up to
3 Ton
4 = 21/2 to
4 Ton
5 = 31/2 to
5 Ton
Cabinet
Width 17 = 17.5" 21 = 21".0 24 = 24.5"
M = Multi X = Low NOx
S = Standard
Revision-
Marketing
(A – First Time
Release)
Air
Model Number Identification
R802V (UF/HZ) Series
5
Model Number Identification
[ ] Designates Metric Conversions
Air
Dimensional Data
R802V (UF/HZ) Series
6
Upflow Application
MODEL R802V-
A B C D E F
REDUCED CLEARANCE (IN.) [mm]
SHIP
WGTS.
(LBS.) [kg]
LEFT SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
050, 075317 171/2 [445] 1611/32 [415] 123/8 [314]
151/2 [381] 21/2 [64] 0
3 [76]
0 1 [25] 3 [76]
6 [152]
125 [57]
075421, 100 211/2 [533] 1927/32 [504] 141/8 [359]
181/2 [470] 21/2 [64] 0 0 0 1 [25] 3 [76]
6 [152]
140 [64]
125 241/2 [622] 2311/32 [593] 157/8 [403]
221/2 [559] 21/2 [64] 0 0 0 1 [25] 3 [76]
6 [152]
150 [68]
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 in accordance with local codes.
[ ] Designates Metric Conversions
Dimensional Data: Upflow Model
Air
Dimensional Data
R802V (UF/HZ) Series
7
Horizontal Application
MODEL R802V-
A B C D E F
REDUCED CLEARANCE (IN.) [mm]
SHIP
WGTS.
(LBS.) [kg]
LEFT SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
050, 075317 171/2 [445] 1611/32 [415] 123/8 [314]
151/2 [381] 21/2 [64] 0
3 [76]
0 1 [25] 3 [76]
6 [152]
125 [57]
075421, 100 211/2 [533] 1927/32 [504] 141/8 [359]
181/2 [470] 21/2 [64] 0 0 0 1 [25] 3 [76]
6 [152]
140 [64]
125 241/2 [622] 2311/32 [593] 157/8 [403]
221/2 [559] 21/2 [64] 0 0 0 1 [25] 3 [76]
6 [152]
150 [68]
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 in accordance with local codes.
[ ] Designates Metric Conversions
Dimensional Data: Horizontal Model
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS
FACING UPWARDS.
Air
Blower Performance Data
R802V (UF/HZ) Series
8
MODEL NUMBER R802VA050317MSA R802VA075317MSA R802VA075421MSA R802VA100521MSA R802VA125524MSA
TARGET GAS
HEATING
AIRFLOW
HIGH
HEATING CFM
SW15 = OFF SW16 = OFF
890 1425 1345 1400 1985
SW15 = ON SW16 = OFF
790 1200 1100 1250 1700
SW15 = OFF SW16 = ON
DO NOT USE
SW15 = ON SW16 = ON
735 1075 960 1150 1530
LOW
HEATING CFM
SW13 = OFF SW14 = OFF
835 1125 1045 1200 1500
SW13 = ON SW14 = OFF
590 950 865 1050 1275
SW13 = OFF SW14 = ON
DO NOT USE
SW13 = ON SW14 = ON
510 825 665 950 1150
TARGET
COOLING/
HEAT-PUMP
AIRFLOW
HIGH
COOLING CFM
SW4 = OFF SW5 = OFF
1200 1200 1600 2000 2000
SW4 = ON SW5 = OFF
1000 1000 1400 1600 1600
SW4 = OFF SW5 = ON
800 800 1200 1400 1400
SW4 = ON SW5 = ON
600 600 1000 1200 1200
LOW
COOLING CFM
SW4 = OFF SW5 = OFF
900 900 1200 1500 1500
SW4 = ON SW5 = OFF
750 750 1050 1200 1200
SW4 = OFF SW5 = ON
600 600 900 1050 1050
SW4 = ON SW5 = ON
450 450 750 900 900
[ ] Designates Metric Conversions
Blower Performance Data
Air
Accessories
R802V (UF/HZ) Series
9
FILTER RACK FILTER SIZES* INCHES [mm]
MODEL
R802V
RXGF-CB
(UPFLOW/
HORIZONTAL)
RXGF-CD
(UPFLOW)
SIDE RETURN
050 & 075317
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
075421 &
100
191/4 x 25
[489 x 635]
153/4 x 25
[400 x 635]
125
223/4 x 25
[578 x 635]
153/4 x 25
[400 x 635]
WARNING: IMPORTANT NOTICE
A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS.
FURNACE SOLID BASE BASE
WIDTH BOTTOM PLATE NO. PLATE SIZE
IN. [mm] KIT NO. IN. [mm]
17
1
/2 [445] RXGB-D17 AE-61874-02 151/8 x 239/16 [384 x 598]
21
1
/2 [533] RXGB-D21 AE-61874-03 185/8 x 239/16 [473 x 598]
24
1
/2 [622] RXGB-D24 AE-61874-04 255/8 x 239/16 [651 x 598]
FOR HIGH ALTITUDES:
OPTION CODE FOR HIGH ALTITUDE: U.S.
None required for high altitudes.
HIGH ALTITUDE CONVERSION KITS: U.S. None required for high altitudes.
80+ HIGH ALTITUDE INSTRUCTIONS CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
when converting for high altitudes.
High altitude option codes are not required for these models. However, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information.
[ ] Designates Metric Conversions
SIDE RETURN FILTER RACK: RXGF-CD BOTTOM RETURN FILTER RACK FOR
UPFLOW APPLICATION: RXGF-CB
INDOOR COIL CASINGS
MODEL
NUMBER
RXBC-D17AI RXBC-D21AI RXBC-D21BI RXBC-D24AI
4" FLUE ADAPTER: RXGW-C01
CONTRACTOR BENEFITS:
• Auto/Self Configuration
• Day-at-a-glance scheduling, with programmable fan
• Intuitive wiring connections
• Dual fuel ready
• Automatically optimizes airflow
• System status & mode information
• Complete diagnostic information on display
HOMEOWNER BENEFITS:
• Large, easy to read icons and characters
• Auto-mode control
• Smart recovery
• Continuous Fan Mode (5 speeds)
• Humidity Control
• Water heater, pool heater integration* (check model compatibility)
*ECONET CONTROL ACCESSORIES:
Wall Plate = RCPN-AMC08 Face Plate = RETSTFPL
IMPORTANT: Existing Comfort Control2System Condensing Units & Heat Pumps are compatible with EcoNet when matched with a R802V Gas Furnace and with an EcoNet Translator (RETRN620CC2) installed on the Comfort Control
2
System control board.
*Available through PROSTOCK®.
ECONET CONTROL
RECOMMENDED COMMUNICATING FURNACE CONTROL
RETST600SYS
Air
Limited Warranty
R802V (UF/HZ) Series
10
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties,
including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Parts*..........................................................Ten (10) Years
Heat Exchanger ........................................Limited Lifetime
Air
Notes
R802V (UF/HZ) Series
11
The new degree of comfort.
Rheem Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.rheem.com
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A. 3/15 QG FORM NO. G11-546 REV. 1
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario • L6Y 0P5
Loading...