Rheem Package Dedicated Horizontal A-C Specification

FORM NO. A11-186 REV. 5
Supersedes Form No. A11-186 Rev. 4
Featuring Industry Standard R-410A Refrigerant
RSNM- HIGH EFFICIENCY 13-SEER SERIES
NOMINAL SIZES 2-5 TONS [7-17.6 kW]
RSPM- SUPER HIGH EFFICIENCY 14-SEER SERIES
NOMINAL SIZES 2-5 TON [7-17.6 kW]
PACKAGE
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched
with appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
(14 SEER ONLY)
2
TABLE OF CONTENTS
Unit Features & Benefits ..............................................................................3-6
Model Identification Options ............................................................................7
General Data
RSNM- Series ........................................................................................8-10
RSPM- Series ......................................................................................11-13
Performance Data
RSNM- Cooling Series ..........................................................................14-16
RSPM- Cooling Series ..........................................................................17-20
Airflow Performance RSNM/RSPM- Series..................................................21-24
Electrical Data
RSNM- Series ..........................................................................................25
RSPM- Series............................................................................................26
Electric Heater Kits ..................................................................................27-30
Dimensional Data..........................................................................................31
Typical Installations ......................................................................................32
Accessories ..................................................................................................33
Typical Wiring ..........................................................................................34-39
Limited Warranty ..........................................................................................40
UNIT FEATURES & BENEFITS—RSNM/RSPM- SERIES
3
The RSNM/RSPM series of Package Air Conditioners are designed to be the most efficient, quickest to install, easiest to service, and most reliable units in the industry - while still maintain­ing an affordable price. This platform provides you with a full line of nominal capacities from 2 through 5 tons utilizing earth-friendly R-410A refrigerant. This unit is suitable for use in mobile homes, manufactured housing and conventionally constructed residential and commercial buildings where horizontally-ducted systems are preferred. RSNM models are 13 SEER, and RSPM Models are 14 SEER, each AHRI-certified.
As with all units offered by Rheem, we started our design process with input from the customer. From fan grille to the base rails, Rheem has combined 30 years worth of package unit design experience with input from Dealers to meet the latest application requirements.
Starting at the bottom, the base rails ()allow for separation between the unit base and the ground level, protecting the base from ground moisture and providing air circulation around the unit. Constructed from sturdy 14-gauge G-90 sheet metal, the base rails also allow for easier maneuverability during installation.
1
1
2
1
1
1
4
UNIT FEATURES & BENEFITS—RSNM/RSPM- SERIES
While other manufacturers have chosen to use pre-painted steel in their equipment, which exposes raw edges and invites rust and sharp edges, Rheem package equipment uses a powder-coat paint system, rated at 1000 hour salt spray per ASTM B117. The powder-coat process also greatly diminishes and dulls sharp edges, reducing the occurrence of cuts and torn clothes.
To provide flexibility in space-limited installations, the unit can be installed flush to the structure without blocking airflow over the outdoor coil or making any screws inaccessible for maintenance. Furthermore, the cabinet is a slim 33" wide. Full-louver coil pro­tection ()makes Rheem unique in the industry and also totally protects the outdoor coil from vandalism and weather extremes.
Two round 14" duct collar ()are included with the unit, which makes attaching duct a snap. The collar is crimped around the leading edge, making it easier to install duct onto the collar. A metal bead around the circumference prevents the attached duct­ing from sliding off after installation.
Keeping service technicians in mind, Rheem takes pride providing easy access to internal components. The outdoor-section top cover () is easily removed to allow access to the scroll com-
pressor (), outdoor fan motor (), and refrigerant tubing
()
.
7
65
4
3
2
5
6
7
4
2
3
5
UNIT FEATURES & BENEFITS—RSNM/RSPM- SERIES
The indoor-section top cover also easily opens to access the removable blower housing and motor (). This also gains total
access to the indoor coil for cleaning and service ().
The indoor motor and blower system will achieve nominal 400 CFM per ton up to a minimum of .8 inches of static pressure, which helps to eliminate customer dissatisfaction over poor airflow brought about by high-static duct designs.
Optional electric heat ()can be specified as factory installed, or can be easily installed in the field, with either dual- or single-point power connections.
10
9
8
The controls are located in a large, easy-to-access control box (), which provides plenty of space in which to troubleshoot.
The transformer () is protected by an in-line fuse, which protects the transformer during a low-voltage electrical short. The low­voltage ()and high-voltage ()wiring connections are easily accessed and have ample room around which to maneuver. Troubleshooting is further aided with number- and color-coded wiring, which corresponds with the large, easy-to-read wiring dia­gram located on the inside of the control box access panel.
1413
12
11
10
11
12
13
14
10
9
8
6
UNIT FEATURES & BENEFITS—RSNM/RSPM- SERIES
High and low refrigerant pressure can easily and accurately be measured using the two gauge ports ()located inside the control box.
15
A small side panel grants access to a removable, sloped drain pan (), which helps to ensure indoor air quality (IAQ) throughout the life of the unit. A 3/4" drain trap () assembly is provided for convenience.
“Patent 7,430,877”
17
16
Foil-faced insulation is securely glued and captured to the cabinet. On the base of the unit, closed-cell insulation is used to prevent moisture from being absorbed and help reduce mold content to provide better indoor air quality.
For reliability and long-lasting operation, Rheem uses 100% scroll compressor technology () on all package platforms. With over 12 years of history, the scroll compressor has proven to be reli­able, efficient, and quiet during operation.
18
16
17
15
18
7
MODEL IDENTIFICATION—RSNM/RSPM- SERIES
R S N M — A 036 J K 010
Heating Capacity (Factory Installed) 000 = No Resistance Heat 005 = 05 KW Resistance Heat 007 = 07 KW Resistance Heat 010 = 10 KW Resistance Heat 015 = 15 KW Resistance Heat 020 = 20 KW Resistance Heat *
Drive Package K = Direct Drive
Electrical Designation J = 208-230V—1PH—60 Hz C = 208-230V—3PH—60 Hz
Nominal Cooling Capacity (BTUH) [kW] 024 = 24,000 [7.03] 030 = 30,000 [8.79] 036 = 36,000 [10.55] 042 = 42,000 [12.31] 043 = 42,000 [12.31] 048 = 48,000 [14.07] 060 = 60,000 [17.59]
Future Technical Variations
Design Series M = R-410A
Efficiency Designation N = 13 SEER High Efficiency P = 14 SEER Super High Efficiency
Product Classification S = Package Air Conditioner
Tradebrand R = Rheem
Not available in 3 phase models.
*Available in 3
1/
2
, 4 and 5 ton models.
[ ] Designates Metric Conversions
NOMINAL SIZES 2-5 TONS [7-17.6 kW]
Model RSNM- Series A024JK A030JK A036CK A036JK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 24,800 [7.27] 30,000 [8.79] 37,200 [10.9] 37,200 [10.9] EER/SEER
2
11.3/13 11.5/13 11.3/13 11.3/13 Nominal CFM/AHRI Rated CFM [L/s] 800/800 [378/378] 1000/1000 [472/472] 1200/1200 [566/566] 1200/1200 [566/566] AHRI Net Cooling Capacity Btu [kW] 23,800 [6.97] 28,800 [8.44] 35,800 [10.49] 35,800 [10.49] Net Sensible Capacity Btu [kW] 18,400 [5.39] 22,200 [6.5] 27,300 [8] 27,300 [8]
Net System Power kW 2.1 2.5 3.17 3.17
Net Weight lbs. [kg] 304 [138] 306 [139] 309 [140] 309 [140]
Compressor
No./Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll
Outdoor Sound Rating (dB)
3
76 76 76 76
Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 10.44 [0.97] 12.64 [1.17] 12.65 [1.18] 12.65 [1.18] Rows / FPI [FPcm] 1 / 20 [8] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9]
Net Latent Capacity Btu [kW] 5,400 [1.58] 6,600 [1.93] 8,500 [2.49] 8,500 [2.49]
Indoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 4.33 [0.4] 4.33 [0.4] 4.33 [0.4] 4.33 [0.4] Rows / FPI [FPcm] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm]
4
1/1 [25.4] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4]
Outdoor Fan—Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6] Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 3400 [1604] 3400 [1604] 3400 [1604] 3400 [1604] No. Motors/HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP Motor RPM 875 875 875 875
Indoor Fan—Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/2 No. Motors 1 1 1 1 Motor HP 1/4 1/3 1/2 1/2 Motor RPM (Nominal) 1033 1080 1050 1050 Motor Frame Size 48 48 48 48
Filter—Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No (No.) Size Recommended in. [mm] (1)1x20x16 [25x508x406] (1)1x20x20 [25x508x508] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] (R-410A) 70 [1984] 78 [2211] 78 [2211] 78 [2211] Weights
Ship Weight lbs. [kg] 328 [149] 330 [150] 333 [151] 333 [151]
CONTINUED
[ ] Designates Metric Conversions
8
GENERAL DATA—RSNM- SERIES
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360.
2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.
4. Standard 3/4" PVC P-Trap provided.
Model RSNM- Series A042CK A042JK A048CK A048JK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 43,000 [12.6] 43,000 [12.6] 48,000 [14.06] 48,000 [14.06] EER/SEER
2
11.1/13 11.1/13 11.3/13 11.3/13 Nominal CFM/AHRI Rated CFM [L/s] 1400/1400 [661/661] 1400/1400 [661/661] 1600/1550 [755/731] 1600/1550 [755/731] AHRI Net Cooling Capacity Btu [kW] 41,500 [12.16] 41,500 [12.16] 46,000 [13.48] 46,000 [13.48] Net Sensible Capacity Btu [kW] 31,500 [9.23] 31,500 [9.23] 35,500 [10.4] 35,500 [10.4]
Net System Power kW 3.74 3.74 4.07 4.07
Net Weight lbs. [kg] 333 [151] 333 [151] 349 [158] 349 [158]
Compressor
No./Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll
Outdoor Sound Rating (dB)
3
76 76 78 78
Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 12.65 [1.18] 12.65 [1.18] 16.54 [1.54] 16.54 [1.54] Rows / FPI [FPcm] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9]
Net Latent Capacity Btu [kW] 10,000 [2.93] 10,000 [2.93] 10,500 [3.08] 10,500 [3.08]
Indoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 5.78 [0.54] 5.78 [0.54] 5.78 [0.54] 5.78 [0.54] Rows / FPI [FPcm] 3 / 13 [5] 3 / 13 [5] 3 / 13 [5] 3 / 13 [5] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm]
4
1/1 [25.4] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4]
Outdoor Fan—Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6] Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 3400 [1604] 3400 [1604] 4200 [1982] 4200 [1982] No. Motors/HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP Motor RPM 875 875 1075 1075
Indoor Fan—Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/11x9 [279.4x228.6] 1/11x9 [279.4x228.6] 1/11x9 [279.4x228.6] 1/11x9 [279.4x228.6] Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/2 No. Motors 1 1 1 1 Motor HP 1/2 1/2 3/4 3/4 Motor RPM (Nominal) 1075 1075 1075 1075 Motor Frame Size 48 48 48 48
Filter—Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No (No.) Size Recommended in. [mm] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] (R-410A) 86 [2438] 86 [2438] 114 [3232] 114 [3232] Weights
Ship Weight lbs. [kg] 357 [162] 357 [162] 375 [170] 375 [170]
CONTINUED
NOMINAL SIZES 2-5 TONS [7-17.6 kW]
[ ] Designates Metric Conversions
9
GENERAL DATA—RSNM- SERIES
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360.
2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.
4. Standard 3/4" PVC P-Trap provided.
10
GENERAL DATA—RSNM- SERIES
Model RSNM- Series A060CK A060JK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 63,000 [18.46] 63,000 [18.46] EER/SEER
2
11.3/13 11.3/13 Nominal CFM/AHRI Rated CFM [L/s] 2000/1900 [944/897] 2000/1900 [944/897] AHRI Net Cooling Capacity Btu [kW] 60,000 [17.58] 60,000 [17.58] Net Sensible Capacity Btu [kW] 45,000 [13.18] 45,000 [13.18]
Net System Power kW 5.31 5.31
Net Weight lbs. [kg] 364 [165] 364 [165]
Compressor
No./Type 1/Scroll 1/Scroll
Outdoor Sound Rating (dB)
3
78 78
Outdoor Coil—Fin Type Louvered Louvered
Tube Type Rifled Rifled Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 16.54 [1.54] 16.54 [1.54] Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9]
Net Latent Capacity Btu [kW] 15,000 [4.4] 15,000 [4.4]
Indoor Coil—Fin Type Louvered Louvered
Tube Type Rifled Rifled Tube Size in. [mm] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 5.78 [0.54] 5.78 [0.54] Rows / FPI [FPcm] 4 / 13 [5] 4 / 13 [5] Refrigerant Control TX Valves TX Valves Drain Connection No./Size in. [mm]
4
1/1 [25.4] 1/1 [25.4]
Outdoor Fan—Type Propeller Propeller
No. Used/Diameter in. [mm] 1/24 [609.6] 1/24 [609.6] Drive Type/No. Speeds Direct/1 Direct/1 CFM [L/s] 4000 [1888] 4000 [1888] No. Motors/HP 1 at 1/3 HP 1 at 1/3 HP Motor RPM 1075 1075
Indoor Fan—Type FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/11x9 [279.4x228.6] 1/11x9 [279.4x228.6] Drive Type/No. Speeds Direct/2 Direct/2 No. Motors 1 1 Motor HP 3/4 3/4 Motor RPM (Nominal) 1075 1075 Motor Frame Size 48 48
Filter—Type Field Supplied Field Supplied
Furnished No No (No.) Size Recommended in. [mm] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] (R-410A) 178 [5046] 178 [5046] Weights
Ship Weight lbs. [kg] 390 [177] 390 [177]
NOMINAL SIZES 2-5 TON [7-17.6 kW]
[ ] Designates Metric Conversions
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360.
2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.
4. Standard 3/4" PVC P-Trap provided.
Model RSPM- Series A024JK A030JK A036CK A036JK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 25,200 [7.38] 30,400 [8.91] 37,600 [11.02] 37,600 [11.02] EER/SEER
2
12.4/14 12.25/14 12.2/14 12.2/14 Nominal CFM/AHRI Rated CFM [L/s] 800/800 [378/378] 1000/1000 [472/472] 1200/1200 [566/566] 1200/1200 [566/566] AHRI Net Cooling Capacity Btu [kW] 24,200 [7.09] 29,200 [8.56] 36,200 [10.61] 36,200 [10.61] Net Sensible Capacity Btu [kW] 18,800 [5.51] 23,000 [6.74] 27,700 [8.12] 27,700 [8.12]
Net System Power kW 1.95 2.38 2.97 2.97
Net Weight lbs. [kg] 304 [138] 306 [139] 309 [140] 309 [140]
Compressor
No./Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll
Outdoor Sound Rating (dB)
3
76 76 76 76
Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 10.44 [0.97] 12.64 [1.17] 12.65 [1.18] 12.65 [1.18] Rows / FPI [FPcm] 1 / 20 [8] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9]
Net Latent Capacity Btu [kW] 5,400 [1.58] 6,200 [1.82] 8,500 [2.49] 8,500 [2.49]
Indoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 4.33 [0.4] 4.33 [0.4] 4.33 [0.4] 4.33 [0.4] Rows / FPI [FPcm] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm]
4
1/1 [25.4] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4]
Outdoor Fan—Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6] Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 3400 [1604] 3400 [1604] 3400 [1604] 3400 [1604] No. Motors/HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP Motor RPM 875 875 875 875
Indoor Fan—Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/2 No. Motors 1 1 1 1 Motor HP 1/4 1/3 1/2 1/2 Motor RPM (Nominal) 1050 1050 1050 1050 Motor Frame Size 48 48 48 48
Filter—Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No (No.) Size Recommended in. [mm] (1)1x20x16 [25x508x406] (1)1x20x20 [25x508x508] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] (R-410A) 70 [1984] 78 [2211] 78 [2211] 78 [2211] Weights
Ship Weight lbs. [kg] 328 [149] 330 [150] 333 [151] 333 [151]
CONTINUED
NOMINAL SIZES 2-5 TON [7-17.6 kW]
[ ] Designates Metric Conversions
11
GENERAL DATA—RSPM- SERIES
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360.
2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.
4. Standard 3/4" PVC P-Trap provided.
Model RSPM- Series A042CK A042JK A043CK A043JK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 43,500 [12.75] 43,500 [12.75] 43,000 [12.6] 43,000 [12.6] EER/SEER
2
11.85/14 11.85/14 12/14 12/14 Nominal CFM/AHRI Rated CFM [L/s] 1400/1400 [661/661] 1400/1400 [661/661] 1400/1400 [661/661] 1400/1400 [661/661] AHRI Net Cooling Capacity Btu [kW] 42,000 [12.31] 42,000 [12.31] 42,000 [12.31] 42,000 [12.31] Net Sensible Capacity Btu [kW] 32,500 [9.52] 32,500 [9.52] 32,000 [9.38] 32,000 [9.38]
Net System Power kW 3.53 3.53 3.5 3.5
Net Weight lbs. [kg] 333 [151] 333 [151] 333 [151] 333 [151]
Compressor
No./Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll
Outdoor Sound Rating (dB)
3
76 76 76 76
Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 12.65 [1.18] 12.65 [1.18] 12.65 [1.18] 12.65 [1.18] Rows / FPI [FPcm] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9]
Net Latent Capacity Btu [kW] 9,500 [2.78] 9,500 [2.78] 10,000 [2.93] 10,000 [2.93]
Indoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 5.78 [0.54] 5.78 [0.54] 5.78 [0.54] 5.78 [0.54] Rows / FPI [FPcm] 3 / 13 [5] 3 / 13 [5] 3 / 13 [5] 3 / 13 [5] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm]
4
1/1 [25.4] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4]
Outdoor Fan—Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6] Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 3400 [1604] 3400 [1604] 3400 [1604] 3400 [1604] No. Motors/HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP Motor RPM 875 875 850 850
Indoor Fan—Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/11x9 [279.4x228.6] 1/11x9 [279.4x228.6] 1/11x9 [279x229] 1/11x9 [279x229] Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/2 No. Motors 1 1 1 1 Motor HP 1/2 1/2 1/2 1/2 Motor RPM (Nominal) 1050 1050 1075 1075 Motor Frame Size 48 48 48 48
Filter—Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No (No.) Size Recommended in. [mm] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] (R-410A) 86 [2438] 86 [2438] 86 [2438] 86 [2438] Weights
Ship Weight lbs. [kg] 357 [162] 357 [162] 357 [162] 357 [162]
CONTINUED
NOMINAL SIZES 2-5 TONS [7-17.6 kW]
[ ] Designates Metric Conversions
12
GENERAL DATA—RSPM- SERIES
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360.
2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.
4. Standard 3/4" PVC P-Trap provided.