Rheem MPi 551 Series, MPi 551 325, MPi 551 410 Owner's Manual And Installation Instructions

This water heater must be installed and serviced by a qualified person.
Please leave this guide with the householder.
Owners Guide
and
Installation Instructions
Water Heater
MPi 551 Series
PATENTS
This water heater may be protected by one or more patents or registered designs in the name of
Rheem Australia Pty Ltd.
TRADE MARKS
®
Registered trademark of Rheem Australia Pty Ltd.
™ Trademark of Rheem Australia Pty Ltd.
Note: Every care has been taken to ensure accuracy in preparation of this publication.
No liability can be accepted for any consequences, which may arise as a result of its application.
3
CONTENTS
HOUSEHOLDER – We recommend you read pages 4 to 18.
The other pages are intended for the installer but may be of interest.
About Your Water Heater ............................................................................................................ 4
Regular Care .............................................................................................................................. 10
Water Supplies ........................................................................................................................... 12
Save A Service Call ................................................................................................................... 14
Installation .................................................................................................................................. 19
Heat Pump And Tank Assembly .............................................................................................. 25
Connections – Plumbing .......................................................................................................... 36
Connections – Electrical ........................................................................................................... 38
Commissioning .......................................................................................................................... 40
Draining The Water Heater ....................................................................................................... 42
Warranty ..................................................................................................................................... 43
4
ABOUT YOUR WATER HEATER
WATER HEATER APPLICATION
This water heater is designed for use in a single family domestic dwelling for the purpose of heating potable water. Its use in an application other than this may shorten its life.
MODEL TYPE
Your Rheem® air sourced heat pump water heater is designed for outdoor installation only. The model you have chosen is a 551 series model. The 551 325 model water heater is recommended for connection to a minimum 16 hour per day power supply. The 551 410 model water heater is recommended for connection to a 24 hour per day power supply.
A Rheem heat pump water heater consumes less energy than an electric water heater. The impact on an electricity account will depend on the tariff arrangement of the water heater replaced and where you live. Contact your energy provider for more information on tariff arrangements and cost comparisons.
The Rheem air sourced heat pump water heater has a Rheemglas® vitreous enamel lined steel cylinder. The water heater‟s evaporator absorbs heat from the surrounding air and transfers this heat into the water.
When hot water is drawn off and cold water enters the tank, the thermostat activates a fan, a compressor and a circulator. The fan draws outside air in through the air inlet louvres at the side of the heat pump module and the pump circulates water from the bottom of the storage tank through a heat exchanger. Heat is absorbed from the air by an evaporator and transferred into the water through the heat exchanger. The resulting cold air is then discharged through the air outlet grille back to atmosphere and the heated water is circulated back into the storage tank. This process continues while heating is required until the water in the storage tank reaches a temperature of 60°C.
Even on cloudy or cold days, heat is drawn from the surrounding air. The heat pump will operate when the ambient air temperature is between a minimum of 3°C to 5°C and maximum of 45°C to 55°C. The booster heating unit will operate when the ambient air temperature is outside of this temperature range if heating is required. The efficiency of the water heater increases as the ambient air temperature increases within the operating range of the heat pump.
Automatic safety controls are fitted to the water heater to provide safe and efficient operation.
ELECTRIC BOOSTING
Ice may begin to form on the evaporator reducing the heat pump efficiency, when the ambient air temperature falls below 7°C and the heat pump has been operating for an extended period. At ambient air temperatures below 3°C to 5°C, the water heater deactivates the heat pump operation and switches to the booster heating unit. During this period the evaporator will defrost if necessary.
At ambient air temperatures above 45°C to 55°C, the water heater deactivates the heat pump operation and switches to the booster heating unit.
The water inside the tank will be heated to a temperature of 70°C by the electric booster heating unit if heating is required. The temperature setting of the thermostat controlling the booster heating unit is not adjustable and is set at 70°C.
Boost Capacity
Element size
551 325
551 410
2.4 kW*, 3.6 kW*
180 litres
200 litres
1.8 kW
100 litres
-
* The boost capacity of a 2.4 kW or 3.6 kW low watts density heating unit if used is 100 litres (551 325) or 125 litres (551 410).
ABOUT YOUR WATER HEATER
5
MAINS PRESSURE
The water heater is designed to operate at mains pressure by connecting directly to the mains water supply. If the mains supply pressure in your area exceeds that shown on page 20, a pressure limiting valve must be fitted. The supply pressure should be greater than 350 kPa for true mains pressure operation to be achieved. A minimum water supply pressure of 200 kPa is required to enable the heat pump circulator and heat pump system to operate effectively.
HOW HOT SHOULD THE WATER BE?
The system controls (compressor, evaporator and fan) will operate until a water temperature of 60°C is reached. If the ambient air temperature is outside of the heat pump‟s operating range, the water temperature is boosted automatically to 70°C by the thermostatically controlled booster electric heating unit, if heating is required.
To meet the requirements of the National Plumbing Standard the temperature of the stored water must not be below 60°C.
HOTTER WATER INCREASES THE RISK OF SCALD INJURY
This water heater can deliver water at temperatures which can cause scalding. Check the water temperature before use, such as when entering a shower or filling a bath or basin, to ensure it is suitable for the application and will not cause scald injury.
We recommend and it may also be required by regulations that an approved temperature limiting device be fitted into the hot water pipe work to the bathroom and ensuite when this water heater is installed. This will keep the water temperature below 50°C at the bathroom and ensuite. The risk of scald injury will be reduced and still allow hotter water to the kitchen and laundry.
TEMPERATURE ADJUSTMENT
The thermostats controlling the heat pump and the booster heating unit are factory set and not adjustable.
WARNING
This water heater is only intended to be operated by persons who have the experience or the knowledge and the capabilities to do so. This water heater is not intended to be operated by persons with reduced physical, sensory or mental capabilities i.e. the infirm, or by children. Children should be supervised to ensure they do not interfere with the water heater.
This water heater uses 240 V AC electrical power for operation of the control systems and the electrically operated components. The removal of the access cover(s) will expose 240 volt wiring. They must only be removed by a qualified person.
Do not use aerosols, stain removers and household chemicals near the water heater whilst it is
working. Gases from some aerosol sprays, stain removers and household chemicals are corrosive to the materials used in the heat pump system.
Do not store swimming pool chemicals, household cleaners, etc., near the water heater.
Ensure the air flow, air inlet louvres and outlet grille are not obstructed in any way at any time.
typical maximum temperature
from heat pump operation,
minimum recommended stored
water temperature
maximum recommended supply
temperature to bathrooms and
ensuites
booster temperature setting
ABOUT YOUR WATER HEATER
6
SAFETY
This water heater is supplied with a thermostat, two over-temperature energy cut-outs and a combination temperature pressure relief valve. These devices must not be tampered with or removed. The water heater must not be operated unless each of these devices is fitted and is in working order.
The operation of the over-temperature cut-out on the thermostat indicates a possibly dangerous situation. If the over-temperature cut-out operates, it must not be reset and the water heater must be serviced by a qualified person.
If the electrical supply conduit to the water heater is damaged, it must be replaced by a qualified person in order to avoid a hazard. Phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection.
Warning: For continued safety of this water heater it must be installed, operated and maintained in
accordance with the Owner‟s Guide and Installation Instructions.
The Rheem warranty may not cover faults if relief valves or other safety devices are tampered with or if the installation is not in accordance with these instructions.
OPERATING MODE MONITOR
An operating mode monitor is located on the front of the heat pump module and houses a green and a red LED.
The green LED, marked “NORMAL”, indicates the current operating mode of the heat pump water heater and the red LED, marked “ATTENTION”, indicates a fault mode.
The green LED will emit either a constant glow or a series of flashes, with a 2 second interval between each series. A series of long green flashes may also be emitted.
The red LED will emit a series of flashes, with a 2 second interval between each series, only if there is a particular fault condition with the system.
The modes are:
Flashes
Operational Modes
solid green
(remains on)
Standby mode – water is hot
1 x green
Call for heating received – system checks performed Note: unit may wait and continue flashing until compressor has cooled from its last operation
2 x green
Circulator commences circulation
3 x green
Heat pump operation – compressor and fan running
long green
Heating unit on – ambient air temperature below 3°C to 5°C or above 45°C to 55°C
no green
(remains off)
No power at the water heater or to the heat pump or a possible fault condition
Refer to notes below before calling for service
ABOUT YOUR WATER HEATER
7
Notes:
Power must be available at the water heater and to the heat pump for the LEDs to glow or flash.
When power is turned on or reconnected to the water heater, the red LED will emit a solid glow for
three (3) seconds and then extinguish. This is normal operation and does not indicate a fault. The LED display will then return to the current operational status.
If there is power to the water heater and the green LED is off or the red LED is flashing, this indicates
there may be a fault condition with the water heater. The red LED may emit up to nine flashes in each series of flashes. Refer to “Possible fault condition” on page 7.
Time controlled power supply (power must be available at the water heater)
If the water heater is connected to a time controlled power supply, then during periods of no power supply at the water heater the LEDs will be off.
This is not a fault condition, but a result of no power being available to energise the LEDs.
The green LED will recommence glowing or flashing when power is available again at the water heater.
Heat pump operating range (power must be available to the heat pump)
The heat pump‟s operating range is between an ambient air temperature of a minimum of 3°C to 5°C and a maximum of 45°C to 55°C. The heat pump will not operate when the ambient air temperature is outside the heat pump‟s operating range. If heating is required, the water heater will commence heating with the booster heating unit in booster heating mode (long green flash) instead.
At the completion of this heating cycle by the booster heating unit (long green flash), the thermostat controlling the booster heating unit opens circuit cutting power to the heat pump causing the green LED to go out. This is not a fault condition, but a result of the power being cut to the heat pump by the thermostat.
The green LED will remain off for an extended period of time until the water temperature in the top of the water heater drops to below 62°C and the thermostat closes circuit reinstating power to the heat pump, when the red LED will emit a solid glow for three (3) seconds and then extinguish. The green LED will then recommence to glow or flash.
The green LED will glow (standby mode – water is hot) if the water temperature in the lower part of the water heater is 50°C or more.
The green LED will flash if the water temperature in the lower part of the water heater is less than 50°C. If at least 45 minutes has elapsed after power is reinstated to the heat pump, i.e. 45 minutes after the red LED emitted a solid glow for three (3) seconds and then extinguished, heating of the water by the heat pump will recommence (3 x green flashes) if the ambient air temperature has moved back to within
the heat pump‟s operating range, or the water heater will switch to the booster heating unit (long green
flash) if the ambient air temperature is outside of the heat pump‟s operating range.
Possible fault condition
There may be a fault condition with the water heater if either:
there is power available at the water heater and the green LED is off, and
the water heater has not operated outside of the heat pump‟s operating range (refer to “Heat pump
operating range” on page 7).
Before phoning to arrange a service inspection due to the green LED being off, refer to “Heat Pump
Is Not Operating” on page 15 in the “Save A Service Call” section of this Owner‟s Guide.
or
the red LED is flashing – the red LED may emit up to nine flashes in each series of flashes
The fault condition which led to the red LED flashing may be cleared after the backup heating cycle by the booster heating unit has completed. When heating is next required the red LED will recommence to flash the fault code for thirty (30) seconds and then extinguish. If the red LED then recommences to flash or recommences to flash after the heat pump next operates, a service call may be required.
Before phoning to arrange a service inspection due to the red LED flashing, refer to “Heat Pump Is
Not Operating” on page 15 in the “Save A Service Call” section of this Owner‟s Guide.
ABOUT YOUR WATER HEATER
8
TIMER CONTROL
A timer can be installed in the electrical circuit to the water heater. The timer must be weatherproof if it is installed outdoors.
It may be desirable for the water heater not to operate between certain hours, such as during the peak period when connected to a Time of Use electricity supply due to a more expensive tariff rate applying.
A timer will affect the operating times of both the heat pump circuit and the booster heating unit.
Note: The 551 325 model water heater is recommended for connection to a minimum 16 hour per day power supply. The 551 410 model water heater is recommended for connection to a 24 hour per day power supply.
TO TURN OFF THE WATER HEATER
If you plan to be away from home for only a few nights, we suggest you leave the water heater switched on.
If it is necessary to turn off the water heater:
Switch off the electrical supply at the isolating switch to the water heater.
Close the cold water isolation valve at the inlet to the water heater.
TO TURN ON THE WATER HEATER
Open the cold water isolation valve fully on the cold water line to the water heater.
Switch on the electrical supply at the isolating switch to the water heater.
Note: When power is turned on or reconnected to the water heater, the red LED will emit a solid glow for three (3) seconds and then extinguish. This is normal operation and does not indicate a fault. The LED display will then return to the current operational status.
The water heater may take up to forty five minutes to commence operating when the power supply is switched on. The heat pump will only operate when power is available at the water heater, the water in the storage tank requires heating, the heat pump compressor is cool and the ambient air temperature is within the heat pump‟s operating temperature range of between a minimum of 3°C to 5°C and a maximum of 45°C to 55°C. If the ambient temperature is outside of this range, the water heater will commence heating with the booster heating unit.
When the heat pump is operating, the system will switch to the booster heating unit if the detected ambient air temperature is outside the operating temperature range of between a minimum of 3°C to 5°C and a maximum of 45°C to 55°C.
The system will not switch back to heat pump operation from the booster heating unit if the detected ambient
air temperature has moved back within the heat pump‟s operating temperature range. The heating cycle will
be completed by the booster heating unit.
Note: The heat pump may not turn on immediately after either having just completed a heating cycle and more hot water is drawn from the water heater or power is shut down to the compressor, either during or at the end of a heating cycle. The heat pump will wait until the compressor has cooled down and the conditions for start up are favourable in order to protect the compressor from damage. This will be a minimum of forty five (45) minutes and may take up to ninety (90) minutes from the last heating cycle.
GOING ON HOLIDAYS
If you plan to be away from home for a few nights, we suggest you leave the water heater switched on. If you plan to be away for a longer period, conserve energy by switching off the isolating switch to the water heater (refer to “To Turn Off The Water Heater” on page 8).
ABOUT YOUR WATER HEATER
9
PRECAUTIONS
Where damage to property can occur in the event of the water heater leaking, the water heater must be installed in a safe tray. Construction, installation and draining of a safe tray must comply with AS/NZS 3500.4 and all local codes and regulatory authority requirements.
The water heater must be maintained in accordance with the Owner‟s Guide and Installation Instructions.
Refer to “Regular Care” on page 10 and to “Anode Inspection and Replacement” on page 12.
If this water heater is to be used where an uninterrupted hot water supply is necessary for your application or business you should ensure that you have back up redundancy within the hot water system design. This should ensure the continuity of hot water supply in the event that this water heater were to become inoperable for any reason. We recommend you seek advice from your plumber or specifier about your needs and building back up redundancy into your hot water supply system.
HOW DO I KNOW IF THE WATER HEATER IS INSTALLED CORRECTLY?
Installation requirements are shown on pages 19 to 23. The water heater must be installed:
by a qualified person, and
in accordance with the installation instructions, and
in compliance with Standards AS/NZS 3500.4, AS/NZS 3000 and all local codes and regulatory authority
requirements.
In New Zealand, the installation must also conform with Clause G12 of the New Zealand Building Code.
VICTORIAN CUSTOMERS
Notice to Victorian Customers from the Victorian Plumbing Industry Commission. This water heater must be installed by a licensed person as required by the Victorian Building Act 1993.
Only a licensed person will give you a Compliance Certificate, showing that the work complies with all the relevant Standards. Only a licensed person will have insurance protecting their workmanship for 6 years. Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate.
DOES THE WATER CHEMISTRY AFFECT THE WATER HEATER?
The water heater is suitable for most public water supplies, however some water chemistries may have detrimental effects on the water heater, its components and fittings. Refer to “Water Supplies” on page 12.
If you are in a known harsh water area or you are not sure of your water chemistry, have your water checked against the conditions described on pages 12 to 13.
HOW LONG WILL THE WATER HEATER LAST?
The water heater is supported by a manufacturer‟s warranty (refer to page 43). There are a number of factors that will affect the length of service the water heater will provide. These include but are not limited to the water chemistry, the water pressure, the water temperature (inlet and outlet) and the water usage pattern. Refer to “Precautions” on page 9.
ENVIRONMENT
At the end of the service life of the heat pump water heater and prior to the water heater being disposed of, a person qualified to work with refrigerants must recover the refrigerant from within the sealed system. The refrigerant must not be vented to atmosphere. Phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection.
10
REGULAR CARE
MINOR SIX MONTH MAINTENANCE
It is recommended minor maintenance be performed every six months by the dwelling occupant.
The minor maintenance includes:
Operate the easing lever on the temperature pressure relief valve. It is very important you raise and
lower the lever gently. Refer to “Temperature Pressure Relief Valve” on page 11.
Warning: Exercise care to avoid any splashing of water, as water discharged from the drain line will
be hot. Stand clear of the drain line‟s point of discharge when operating the valve‟s lever.
Operate the easing lever on the expansion control valve (if fitted). It is very important you raise and
lower the lever gently. Refer to “Expansion Control Valve” on page 11.
Check the drain line from the safe tray (if one is installed) is not blocked.
MAJOR FIVE YEAR SERVICE
It is recommended a major five year service be conducted on the water heater.
Warning: Servicing of a water heater must only be carried out by a qualified person. Phone Rheem
Service or their nearest Accredited Service Agent.
Note: The five year service and routine replacement of any components, such as the anode and relief valve(s), are not included in the Rheem warranty. A charge will be made for this work. Only genuine replacement parts should be used on this water heater.
The major service includes:
Replace the temperature pressure relief valve.
Inspect and flush the expansion control valve (if fitted). If required, replace the valve.
Inspect and if required, replace the anode.
If the anode is not replaced, it should be replaced within three years of this service (refer to “Anode
Inspection and Replacement” on page 12).
Check the electric heating unit for excessive calcium build up or corrosion and replace if necessary.
Check and inspect the heat pump module for operation.
Visually check the unit for any potential problems.
Inspect all connections.
Check the condensate drain.
Check the drain line from the safe tray (if one is installed) is not blocked.
Note: The water heater may need to be drained during this service. After the completion of the service, the water heater will take some time to reheat the water. Depending upon the power supply connection, hot water may not be available until the next day.
HEAT PUMP SYSTEM
It is recommended the evaporator and refrigeration system is checked every five years. In particularly dusty environments, it may be necessary to have the heat pump system checked and cleaned of dust and residue on a more regular basis.
REGULAR CARE
11
TEMPERATURE PRESSURE RELIEF VALVE
This valve is near the top of the water heater and is essential for its safe operation. It is possible for the valve to release a little water through the drain line during each heating period. This occurs as the water is heated and expands by approximately 1/50 of its volume.
Continuous leakage of water from the valve and its drain line may indicate a problem with the water heater (refer to “Temperature
Pressure Relief Valve Running” on page 17).
Warning: Never block the outlet of this valve or its drain line for
any reason.
Operate the easing lever on the temperature pressure relief valve once every six months. It is very important you raise and lower
the lever gently.
DANGER: Failure to do this may result in the water heater
cylinder failing, or under certain circumstances, exploding.
Warning: Exercise care to avoid any splashing of water, as water discharged from the drain line will be hot. Stand clear of the drain line‟s point of discharge when operating the valve‟s lever.
If water does not flow freely from the drain line when the lever is lifted, then the water heater must be checked. Phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection.
The temperature pressure relief valve should be replaced at intervals not exceeding 5 years, or more frequently in areas where there is a high incidence of water deposits (refer to “Water Supplies” on page 12).
EXPANSION CONTROL VALVE
In many areas, including South Australia, Western Australia and scaling water areas, an expansion control valve is fitted to the cold water line to the water heater. The expansion control valve may discharge a small quantity of water from its drain line during the heating period instead of the temperature pressure relief valve on the water heater.
Operate the easing lever on the expansion control valve once every six months. It is very important you raise and lower the lever gently. The expansion control valve should be checked for performance or replaced at intervals not exceeding 5 years, or more frequently in areas where there is a high incidence of water deposits.
water
heater
drain
line
lift until water
flows from the
drain line –
lower gently
12
WATER SUPPLIES
This water heater must be installed in accordance with this advice to be covered by the Rheem warranty.
This water heater is manufactured to suit the water conditions of most public reticulated water supplies. However, there are some known water chemistries which can have detrimental effects on the water heater and its operation and / or life expectancy. If you are unsure of your water chemistry, you may be able to obtain information from your local water supply authority. This water heater should only be connected to a water supply which complies with these guidelines for the Rheem warranty to apply.
CHANGE OF WATER SUPPLY
The changing or alternating from one water supply to another can have a detrimental effect on the operation and / or life expectation of a number of components in this water heater.
Where there is a changeover from one water supply to another, e.g. a rainwater tank supply, bore water supply, desalinated water supply, public reticulated water supply or water brought in from another supply, then water chemistry information should be sought from the supplier or it should be tested to ensure the water supply meets the requirements given in these guidelines for the Rheem warranty to apply.
ANODE
The vitreous enamel lined cylinder of the water heater is only covered by the Rheem warranty when the total dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode is used. If an incorrect colour coded anode is used in the water heater, any resultant faults will not be covered by the Rheem warranty. In addition, the use of an incorrect colour coded anode may shorten the life of the storage tank.
The correct colour coded anode is as shown in the following table:
Total Dissolved Solids
Anode colour code
0 – 40 mg/L
Green
40 – 150 mg/L
Green or Black
150 – 400 mg/L
Black
400 – 600 mg/L
Black or Blue
600 – 2500 mg/L
Blue
2500 mg/L +
Blue (no cylinder warranty)
The changing of anodes must be carried out by a qualified person.
Note: Some water analysis reports may state the conductivity of the water rather than the level of total dissolved solids. Conductivity, measured in microsiemens per centimetre ( µS / cm), is directly proportional to the TDS content of the water. TDS, in mg / L, is approximately 70% of the conductivity in µS / cm.
ANODE INSPECTION AND REPLACEMENT
The anode installed in your water heater will slowly dissipate whilst protecting the cylinder. The life of the cylinder may be extended by replacing the anode.
If the anode is not replaced during a five year service (refer to “Major Five Year Service” on page 10) then the maximum time after installation when the anode should be replaced for this water heater is 8 years.
For water supplies which are either softened, desalinated or where the water supply may alternate between a water tank and a reticulated public supply or another supply, it is recommended the anode be replaced within 5 years of installation.
WATER SUPPLIES
13
CAUTION
If the water supply has a TDS greater than 150 mg/L and a green anode has not been changed to a black anode, or if the TDS is greater than 600 mg/L and the anode has not been changed to a blue anode, there is the possibility the anode may become overactive and hydrogen gas could accumulate in the top of the water heater during long periods of no use. In areas where this is likely to occur, the installer should instruct the householder on how to dissipate the gas safely.
If, under these conditions, the water heater has not been used for two or more weeks the following procedure should be carried out before using any electrical appliances (automatic washing machines and dishwashers) which are connected to the hot water supply.
The hydrogen, which is highly flammable, should be vented safely by opening a hot tap and allowing the water to flow. There should be no smoking or naked flame near the tap whilst it is turned on. Any hydrogen gas will be dissipated. This is indicated by an unusual spurting of the water from the tap. Once the water runs freely, any hydrogen in the system will have been released.
SATURATION INDEX
The saturation index (SI) is used as a measure of the water‟s corrosive or scaling properties.
Where the saturation index is less than –1.0, the water is very corrosive and the Rheem warranty does not apply to the water heater. In a corrosive water supply, the water can attack copper parts and cause them to fail.
Where the saturation index exceeds +0.40, the water is very scaling and the Rheem warranty does not apply to the water heater.
Water which is scaling may be treated with a water softening device to reduce the saturation index of the water.
CHLORIDE AND PH
Where the chloride level exceeds 250 mg/L the Rheem warranty does not apply to the water heater. In a high chloride water supply, the water can corrode stainless steel parts and cause them to fail.
Where the pH is less than 6.0 the Rheem warranty does not apply to the water heater. pH is a measure of whether the water is alkaline or acid. In an acidic water supply, the water can attack stainless steel parts and cause them to fail.
Water with a pH less than 6.0 may be treated to raise the pH. The water supply from a rainwater tank in a metropolitan area is likely to be corrosive due to the dissolution of atmospheric contaminants.
SUMMARY OF WATER CHEMISTRY ADVICE AFFECTING WARRANTY
The water heater is not suitable for certain water chemistries. Those chemistries are listed below. If the water heater is connected at any time to a water supply with the following water chemistry, the Rheem warranty will not cover any resultant faults:
Water Chemistry
Component
Total Dissolved Solids (TDS) > 2500 mg/L
water heater cylinder
Total Dissolved Solids (TDS) not suitable for anode type
water heater cylinder
Saturation Index (SI) < -1.0
water heater
Saturation Index (SI) > +0.4
water heater
Chloride > 250 mg/L
water heater
pH < 6.0
water heater
14
SAVE A SERVICE CALL
Check the items below before making a service call. You will be charged for attending to any condition or fault that is not related to manufacture or failure of a part.
NOT ENOUGH HOT WATER (OR NO HOT WATER)
Is the electricity switched on?
Inspect the isolating switch marked “HOT WATER” or “WATER HEATER” at the switchboard and the
isolating switch (if one is installed) at the water heater and ensure they are turned on.
Check the fuse marked “HOT WATER” or “WATER HEATER” at the switchboard.
Is a timer installed?
If a timer has been installed, ensure sufficient time has been allowed to reheat the storage tank.
Are you using more hot water than you think?
Is one outlet (especially the shower) using more hot water than you think?
Very often it is not realised the amount of hot water used, particularly when showering. Carefully review the family‟s hot water usage. As you have installed an energy saving appliance, energy saving should also be practised in the home.
Adjust your water usage pattern to take advantage of maximum energy gains. Have your plumber install a flow control valve to each shower outlet to reduce water usage.
Heat pump fault
Has the heat pump developed a fault and the red LED is flashing?
The heat pump will not operate and the water heater will switch to backup heating mode using the booster heating unit.
Refer to “Heat Pump Is Not Operating” on page 15.
Temperature pressure relief valve running
Is the relief valve discharging too much water?
Refer to “Temperature Pressure Relief Valve Running” on page 17.
Water heater size
Do you have the correct size water heater for your requirements?
The sizing guide in the sales literature and on the Rheem website (www.rheem.com.au) suggests average sizes that may be needed.
WATER NOT HOT ENOUGH
You may find that due to heavy hot water usage the water temperature may be lower than normally expected, due to insufficient heating time being allowed. You will need to carefully plan your use of the hot water on such occasions.
WATER TOO HOT
The water heater during heat pump operation will heat the water to a temperature of 60°C. In booster heating mode or back up heating mode the water will be heated to 70°C. The heat pump will operate when the ambient air temperature is between a minimum of 3°C to 5°C and maximum of 45°C to 55°C. The booster heating unit will operate in booster heating mode when the ambient air temperature is outside of this temperature range, if heating is required. This is normal operation.
If a heat pump component has developed a fault condition, the heat pump will not operate and the water heater will switch to backup heating mode to ensure a supply of hot water. In backup heating mode, the booster heating unit will operate if heating of the water is required, regardless of the ambient air temperature. The red LED will flash to indicate the fault mode that has occurred. Refer to “Heat Pump Is Not Operating” on page 15.