Rheem Guardian PowerVent User Manual

RHEEM INDUCED DRAFT GAS POWERVENT
More Models, Longer Vent Runs,
Greater Installation Flexibility!
PowerVent – now with the Guardian System
Rheem PowerVent features
Rheem Guardian™FVIR System offers air/fuel
shutoff protection, vapor detection sensor – maintenance free and no filters to clean!
and shorts with the Guardian System plus 75 gallon heavy-duty non-FVIR
Longer vent runs (up to 100 feet), 2 or 3-inch
PVC, ABS, or CPVC vent pipe options and vertical or horizontal termination – for greater installation flexibility
Environmentally friendly low NOx burner
New quiet blower, self-cleaning system,
self-diagnostic control…
and more!
Exceeds new FVIR standards!
Residential water heaters
from Rheem
RHEEM INDUCED DRAFT GAS POWERVENT
HOT
WATER
CONNECTION
COLD
WATER
CONNECTION
POWERVENT
A
SSEMBLY
C
B
F
A
D
G
G
E
T&P FITTING
3/4" N.P.T .
1/2"
Environmentally Friendly Burner
Low NOx design for low
nitrous oxide emissions
High Altitude Compliant
Tall models are certified for applications up to
7,700 feet above sea level Short models: certified up to 6,000 feet above
sea level
Self-Cleaning
EverKleen™patented system fights sediment
build-up Reduces fuel costs
Provides more hot water
Longer Life
Patented magnesium anode rod design
incorporates a special resistor that protects the tank from corrosion. Provides longer
tank life than using standard magnesium anode rods
6-Year Limited Tank
and Parts Warranty
See Residential Warranty Information Brochure for
complete warranty information.
Guardian System
Air/fuel shut-off
system offers double protection Maintenance free –
no filter to clean
Flammable Vapor Detection Sensor
Protective control system that
disables the heater in the presence of flammable vapor accumulation
Flexible Venting Options
Long venting lengths up to 100 feet
PVC, ABS, or CPVC vent pipe options
Vertical or horizontal termination
New Quiet Blower
Less noise than ever before
Self-Diagnostic System
Integrated self-diagnostic
system control takes the guess work away
CROSS REFERENCE AND SPECIFICATIONS
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
TALL
SHORT
T Y P E
PREVIOUS FVIR GAS INPUT IN RECOVERY IN FIRST HOUR TOP OF TANK GAS CONN. SIDE T&P CONN. SHIP. ENERGY AVG. ANN. GAL. MODEL MODEL THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. ASSEMBLY HT. DIAM. CONN. CNTR. VALVE SIZE WT. FACTOR OPER. COSTS CAP. NUMBER NUMBER
40 41VRP40 42VP40F 40 40 40.4 40.4 68 69-1/4 59 19-3/4 14 8 53-1/2 3/4 140 0.64 $213
50 41VRP50 42VP50F 42 42 42.4 42.4 87 68-1/4 58 21-3/4 14 8 52-1/2 3/4 170 0.64 $213
40 NEW! 42VP40SF 36 34 36.4 34.3 71 61-1/2 50-1/2 20-1/4 14 8 44 3/4 152 0.64 $213
50 NEW! 42VP50SF 36 34 36.4 34.3 85 61-1/2 50-1/2 22-1/4 14 8 44 3/4 176 0.62 $220
EW
N
NAT. LP NAT. LP NAT.
T. TO HT. TO WATER HT. TO WATER
H
ABCDEFG(LBS) NAT. NAT. GAS
VENTING INFORMATION FOR 2" VENTS
NUMBER OF MINIMUM MAXIMUM 90° ELBOWS NUMBER PIPE PIPE
WITH VENT OF 45° LENGTH LENGTH TERMINAL ELBOWS REQ. (FT.) (FT.)
One (1) None 4.0 44.0 One (1) One (1) 4.0 41.0 Two (2) None 4.0 38.0 Two (2) One (1) 4.0 35.0
Three (3) None 4.0 32.0
For the 2" vent, one 90° elbow is approximately equal to 6 feet of pipe. One 45° elbow is approximately equal to 3 feet of pipe.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
VENTING INFORMATION FOR 3" VENTS
NUMBER OF MINIMUM MAXIMUM 90° ELBOWS NUMBER PIPE PIPE
WITH VENT OF 45° LENGTH LENGTH
TERMINAL ELBOWS REQ. (FT.) (FT.)
One (1) None 5.0 95.0 One (1) One (1) 5.0 92.5 Two (2) None 5.0 90.0
Two (2) One (1) 5.0 87.5 Three (3) None 5.0 85.0 Three (3) One (1) 5.0 82.5
Four (4) None 5.0 80.0 Four (4) One (1) 5.0 77.5
Five (5) None 5.0 75.0
For the 3" vent, one 90° elbow is approximately equal to 5 feet of pipe. One 45° elbow is approximately equal to 2.5 feet of pipe.
Residential water heaters
Rheem Water Heating • 101 Bell Road, Montgomery, AL 36117-4305 800-621-5622 • sales@rheem.com • www.rheem.com
Rheem Canada Ltd./Ltée • Water Heater Division 128 Barton Street West, Hamilton, Ontario L8N 3P3
Not all models are available in Canada.
Printed in U.S.A. 05/07 WP Form No. 101-65 Rev. 3
from Rheem
Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test proce­dures. D.O.E. national average fuel rate natural gas 91¢/therm; LP $1.23/gallon.
Loading...