Reznor VC Series Option Installation Manual

WIND & RAIN HOOD CONVERSION INSTRUCTIONS
Applies to: Gas-Fired, Tubular, Radiant,
Low-Intensity Infrared Heater
Model VCS/VCT (Harsh Environment )
Part no. 270689
VCS/T Models
Fit Wind &
Rain Hood
CONVERSION KIT PART NUMBER 270615
Part No. Description Quantity
270435 5mm diameter x 16mm long Stainless Steel screw for 1.2mm material 3 270616 VC outdoor air spigot 1 270617 4" outdoor wind and rain hood assembly Stainless Steel 1 270414 No. 8 x 1/2" Stainless Steel cross pan head self tapper 2 270689 Wind and rain hood conversion manual (outdoor only) VC 1
It is essential that when fitting the wind and rain
hood kit that waterproof sealant is used where
indicated.
Step 1: Remove the screws securing the original fresh air inlet plate with a no. 2 cross headed screwdriver,
(keep screws for re-use). Carefully prise off the plate,
(stuck on with sealant), making sure not to damage the burner casing.
Step 2: Apply waterproof sealant apply to the inner
face of the spigot along the line of the circle indicated.