Revox RECONTROL M218 User Manual

M218
M218 Connection plan
The M218 wall-mounted remote control panel enables you to control additional room amplifiers. In conjunction with an interface (M200, M201), it can also be used to control the M51. The M218 has an infrared receiver, which is located behind the lens. In addition, control commands are confirmed with a short, blue flash signal, irrespective of whether the command comes from an infrared signal or direct from the remote control panel keys.
Assembly
Connect the cable to the M218 as described in the chapter configuration that matches your requirements (see chapter board onto the flush mounting box using either the slot-holes at the sides or the drilled holes located at the corners.
Please note: In either case, you must make sure that the screws are only finger tightened, otherwise there is a danger of cracks occurring in the board.
Now you can clip in the corresponding frame with the blanking plate. There are lengthwise internal grooves provided for the
Gira
The external trapezoid shaped cutouts should be used with the
Connection
Connection is made using a two-part, 3-pin Phoenix plug as shown printed on the board.
VCC : + 8 to 20 V (factory setting) Data: IR signal GND: Earth / Screening
Revox recommends the use of a 2-core, screened cable (microphone cable), where the screening us used as the earth.
Dominating Entertainment. Revox of Switzerland.
systems:
1.551.320 .11
REVOX
Connection
Options A B
Merten
VCC
A
B
and select the
). Screw the M218
Jung
and
system:
Data
GND
5V
5V operation with Exception/Evolution
Different power supply levels can be used with the M218. If the solder pad on the rear of the board, which is labelled 5V is closed (solder bridge plugged), the M218 can be operated with a +5V power supply. This is necessary if the M218 is connected to an using the “Remote Display” connector or to an
Exception
Please check the 5V solder pad in each case as otherwise, your M218 will be damaged.
Options
There are two solder pad fields on the rear of the board, labelled A and B (see Connection plan). the factory setting for both these pads is open, i.e. not bridged.
Option A In some cases, it can be advantageous to turn the IR receiver off. This can be done with solder pad A.
Solder pad A closed (solder bridge in place) Æ IR receiver: Off
Solder pad A open (no solder bridge in place) Æ IR receiver: On
Option B Using option B, you can re-address the tuner command (remote address) from tuner to AUX3. This is only necessary if a second tuner has been built into the M51. In this way, for example, you can listen to the first tuner in the main room (and Zone 1) and independently of this, use the second tuner in Zones 2 – 4.
The following steps are necessary:
1. Put solder bridge B in place
2. M51 Setup / Remote Menu
Now, when you press the Tuner key on the M218, the second tuner in When using wall-mounted remote panels with solder pad B not in place on the other hand, the first tuner in
Tip The second tuner should be inserted into as here the screening is best suited for optimised reception.
setup, using the “Option” connector.
A B
Remote button
Tuner
is selecting
“FM Tuner” in
slot 1
Slot 1
Evolution
Remote button
is selecting
“FM Tuner” in
Slot 2
is selected as usual.
setup
Aux3
slot 2
is selected.
Slot 2
Re:connect
M219 connection panel
IR LINK
(Phoenix plug view:)
IN
VCC
+
Data-IR
V209/ 219 connection panel
External IR Receiver
(DIN plug view: solder side)
As well as the earth on PIN 2, the housing of the 7-pin DIN plug should also be earthed.
Technical data
Tip: Up to 5 M218 can be switched in parallel Max. cable length: 40m Power consumption: 17 mA
E & OE We reserve the right to make technical modifications.
TUNER SERVER AUX2
-
6
7
3
1
5
4
2
Earth: GND
CD
><<
+
Guarantee
The guarantee period is 24 months from the date of purchase. Your dealer should be your first contact if you need service.
If he can't give you the help you need, send the M218 carriage free and without any accessories to your national Sales Office. Please supply a complete description of the problem and a full return postal address.
-
GND
VCC (≥ 10Volt)
Data IR
LOCAL
OFFVOL