M219 Additional room amplifier
M219
Additional room
amplifier
General
The M219 is a digital Additional
Room Amplifier from the newest
M Series in the
programme. It is used for the
reproduction of music in the
additional rooms in a Multiroom
system and can also supply the
listener with current information
through an additional display.
The M219 receives the signals
from a selected source (CD,
Tuner, Server ...) in the main
room through a multiroom bus
cable. Volume, balance, bass
and treble settings can be made
in individually in each room.
Also, up to 3 local sources can
be connected and listened to in
each additional room. If you
want “concealed” operation,
various wall-mounted
controllers or IR receivers can
be connected.
Installation
The M219 should be installed in
such a way that the ventilation
slots are not covered up and so
that there is a gap of at least 5
cm ( ≈ 2 in) between the unit
and any walls or furniture.
REVOX Multiroom
M Series
You should avoid installing it in
locations where:
- there is direct sunlight
- it is next to a heat source
- there is poor ventilation
- there is a lot of dust in the
atmosphere
- it is unstable
- there is a risk of splashing
- there is high humidity
Furthermore you may not place
objects filled with liquids, such
as vases, or naked flame
sources, such as lighted
candles, on the M219.
Stacking several M219s
If you want to stack several
M219s on top of each other, we
recommend that you use the
corresponding installation kit,
with the Part no. 1.551.313.00.
Room-AmplifierM219
Room-AmplifierM219
M219
Room-Amplifier
2
M219 Additional room amplifier
Safety
Please take note of the
information shown on the labels
on the rear of the unit. Housings
should not be removed, in order
to avoid the danger of an
electric shock. Maintenance and
repairs should only be carried
out by qualified personnel.
This symbol warns of
“dangerous voltages” within the
unit. In the case of contact with
the corresponding components,
the level of voltage can cause
an electric shock.
!
This symbol indicates important
advice for operation and
maintenance in this
documentation.
M Series
Installation and operation
Please check the unit and
accessories for any signs of
transit damage, once you have
unpacked it. Please read the
operating instructions carefully
before starting to use the unit.
Keep the documentation
somewhere safe for future
reference.
If the unit shows any signs of
damage or has come into
contact with any fluids should
not be connected to a power
supply.
Only use the power cable
supplied. Before connecting the
power, the power supply and
unit connection values (power
voltage, frequency) must be
checked. The fuse used in the
unit must conform to the factory
definitions contained in the
“Technical data” section of this
manual.
3
M219 Additional room amplifier
Safety measures
Operational anomalies
In the case of any unusual
noises or smells coming from
the unit, remove the power
cable immediately. Have the
unit checked as soon as
possible by your supplier.
Do not open the unit
The unit should not be opened
because of the risk of
electrocution.
Periods of non-use
If the unit is not going to be
used for a longer period of time,
the power cable should be
unplugged from the socket as a
safety precaution.
Foreign objects
Fluids, flammables or other
foreign objects should not find
their way into any of the unit’s
openings as this can result in
breakdowns, fire or an electric
shock.
Power cable
Always pull the plug out of the
socket while holding the plug
housing and not the cable.
M Series
Warranty
Device regulations
REVOX offers a warranty in
EU/EEA countries on products
bought within the EU, in
addition to the statutory
warranty provided by the
retailer. The warranty covers
material and labour during the
period of the warranty, which is
stipulated in the individual EU
countries by the
Partners.
In all countries, the terms of
warranty from the
reseller is offered in addition to
the statutory regulations. You
must be able to prove that the
product was bought from an
approved
making any warranty claim.
The warranty is invalidated if
any inappropriate or
unprofessional repairs have
been carried out on the unit.
REVOX Sales
REVOX
REVOX Partner when
4
M219 Additional room amplifier
M Series
M219- Front view
[A][B][C]
[A] IR Sensor
The InfraRed sensor receives
signals from the remote control
or from any other IR control
devices, such as the PDAs for
the music server.
Switching the IR sensor off
If required, the IR sensor can be
switched off using the SETUP
DIL switch [3] on the rear of the
M219.
[B] Status LED
The blue status LED gives information about the current state of the
M219.
LED display M219 Status
Permanently dark M219 standby mode
Permanently lit M219 active
Rapid flashing Breakdown, overload
Rapid flashing Min/max position reached
(Volume, Bass, Treble, Balance)
Slow flashing IR receive (RC5 or RC6 Codes)
Single flash LOCAL 1 or general change of source
Double flash LOCAL 2
Triple flash LOCAL 3
M219
Room-Amplifier
[C] Ventilation slots
The ventilation slots on the front
and the top of the M219 must
always be left clear of
obstructions.
The M219 should be installed in
such a way that the ventilation
slots are not covered up and so
that there is a gap of at least
5cm between the unit and any
walls or furniture.
5
M219 Additional room amplifier
Connection plan
[1][2][3][4][5] [6]
LOCAL IN
12
L
R
3
Short descriptions
[1] Local Cinch inputs L/R
[2] Preamp outputs L/R
[3] DIL setup switches
[4] M219-Link display connector
[5] IR receiver or wall-mounted
remote control connections
[6]Switching voltage input
Rear view
PRE
OUT
14325678
1432
CHANNEL
SELECT
[7][8][9][10][11][12]
SETUP
M219
LINK
OUT
IN
MR-BUSSPEAKERS
[7]
[8] Multiroom Bus input
[9] Multiroom Bus output
[10] Speaker connections L/R
[11] Fuse
[12] Power connection
OUT
--
IN
+
+
+ R - - L +
Stereo/ Mono switch
M Series
FUSEAC - POWER
6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.