Model designation
> For development environments > Compact unit: Vacuum pump and
air compressor in the system
50 Hz, 3 phase / 12A
Tech nical Data
Total weight: ca. 600 kg
VC70A
Model designation
> Process volume/batch max 70 kg > 2-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HL: 22 kW, 400 V,
50 Hz, 3 phase / 52A
Tech nical Data
Chamber weight: ca. 1130 kg Pump unit: ca. 1070 kg Total weight: ca. 2200 kg
Suitab le to oven 72 4 / 725 / 726 Max. u sable space 8 20 x 1000 mm 1 troll ey/batch ca. 14 bat ches/hr
VC40A
Model designation
> Process volume/batch max 40 kg > 2-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV8HW: 11 kW, 400 V,
50 Hz, 3 phase / 27A
Tech nical Data
Chamber weight: ca. 1080 kg Pump unit: ca. 860 kg Total weight: ca. 1940 kg
Suitab le to oven 72 6 Max. u sable space 5 00 x 800 mm 1 troll ey/batch ca. 14 bat ches/hr
VC70A2 - 2 doors
Model designation
> Process volume/batch max 70 kg > 2-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HL: 22 kW, 400 V,
50 Hz, 3 phase / 52A
Tech nical Data
Chamber weight: ca. 1500 kg Pump unit: ca. 1070 kg Total weight: ca. 2570 kg
Suitab le to oven 72 4 / 725 / 726 Max. u sable space 8 20 x 1000 mm 1 troll ey/batch ca. 14 bat ches/hr
VC100W
Model designation
> Process volume/batch max 100 kg > 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV8HW: 11 kW, 400 V,
50 Hz, 3 phase / 27A
> Refrigerating machine 40: 15.4 kW,
400 V, 50 Hz, 3 Phase / 40A
Tech nical Data
Chamber weight: ca. 1380 kg Pump unit: ca. 860 kg Cooling unit: ca. 420 kg Total weight: ca. 2660 kg
Suitab le to oven 72 4 / 725 / 726 Max. u sable space 8 20 x 1000 mm 1 troll ey/batch ca. 14 bat ches/hr
Suitab le for 4 tray s 600 x 400 m m
VC100W2 - 2 doors
VCL200W
VC200W2 - 2 doors
VC200W
Model designation
> Process volume/batch max 100 kg > 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV8HW: 11 kW, 400 V,
50 Hz, 3 phase / 27A
> Refrigerating machine 40: 15.4 kW,
400 V, 50 Hz, 3 Phase /40A
Tech nical Data
Chamber weight: ca. 1750 kg Pump unit: ca. 860 kg Cooling unit: ca. 420 kg Total weight: ca. 3030 kg
Suitab le to oven 72 4 / 725 / 726 Max. u sable space 8 20 x 1000 mm 1 troll ey/batch ca. 14 bat ches/hr
Model designation
> Process volume/batch max 200 kg > 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HW: 22 kW, 400 V,
50 Hz, 3 phase / 52A
> Refrigerating machine 60: 23.3 kW,
400 V, 50 Hz, 3 Phase /63A
Tech nical Data
Chamber weight: ca. 1380 kg Pump unit: ca. 1070 kg Cooling unit: ca. 650 kg Total weight: ca. 3100 kg
Suitab le to oven 72 4 / 725 / 726 Max. u sable space 8 20 x 1000 mm 1 troll ey/batch ca. 14 bat ches/hr
Model designation
> Process volume/batch max 200 kg > 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HW: 22 kW, 400 V,
50 Hz, 3 phase / 52A
> Refrigerating machine 60: 23.3 kW,
400 V, 50 Hz, 3 Phase /63A
Tech nical Data
Chamber weight: ca. 1750 kg Pump unit: ca. 1070 kg Cooling unit: ca. 650 kg Total weight: ca. 3470 kg
Suitab le to oven 72 4 / 725 / 726 Max. u sable space 8 20 x 1000 mm 1 troll ey/batch ca. 14 bat ches/hr
Model designation
> Process volume/batch max 200 kg > 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HW: 22 kW, 400 V,
50 Hz, 3 phase / 52A
> Refrigerating machine 60: 23.3 kW,
400 V, 50 Hz, 3 Phase /63A
Tech nical Data
Chamber weight: ca. 1500 kg Pump unit: ca. 1070 kg Cooling unit: ca. 650 kg Total weight: ca. 3220 kg
Suitab le to oven 2 x 725 / 2 x 7 26 Max. u sable space 8 50 x 1280 mm 2 troll eys/batch ca. 14 ba tches/h r
VCL200W2 - 2 doors
Model designation
> Process volume/batch max 200kg > 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HW: 22 kW, 400 V,
50 Hz, 3 phase / 52A
> Refrigerating machine 60: 23.3 kW,
400 V, 50 Hz, 3 Phase /63A
Tech nical Data
Chamber weight: ca. 1900 kg Pump unit: ca. 1070 kg Cooling unit: ca. 650 kg Total weight: ca. 3620 kg
Suitab le to oven 2 x 725 / 2 x 7 26 Max. u sable space 8 50 x 1280 mm 2 trolleys/batch ca. 14 batches/hr