VC100W2 - 2 doors
VCL200W
VC200W2 - 2 doors
VC200W
Model designation
> Process volume/batch max 100 kg
> 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV8HW: 11 kW, 400 V,
50 Hz, 3 phase / 27A
> Refrigerating machine 40: 15.4 kW,
400 V, 50 Hz, 3 Phase /40A
Tech nical Data
Chamber weight: ca. 1750 kg
Pump unit: ca. 860 kg
Cooling unit: ca. 420 kg
Total weight: ca. 3030 kg
Suitab le to oven 72 4 / 725 / 726
Max. u sable space 8 20 x 1000 mm
1 troll ey/batch ca. 14 bat ches/hr
Model designation
> Process volume/batch max 200 kg
> 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HW: 22 kW, 400 V,
50 Hz, 3 phase / 52A
> Refrigerating machine 60: 23.3 kW,
400 V, 50 Hz, 3 Phase /63A
Tech nical Data
Chamber weight: ca. 1380 kg
Pump unit: ca. 1070 kg
Cooling unit: ca. 650 kg
Total weight: ca. 3100 kg
Suitab le to oven 72 4 / 725 / 726
Max. u sable space 8 20 x 1000 mm
1 troll ey/batch ca. 14 bat ches/hr
Model designation
> Process volume/batch max 200 kg
> 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HW: 22 kW, 400 V,
50 Hz, 3 phase / 52A
> Refrigerating machine 60: 23.3 kW,
400 V, 50 Hz, 3 Phase /63A
Tech nical Data
Chamber weight: ca. 1750 kg
Pump unit: ca. 1070 kg
Cooling unit: ca. 650 kg
Total weight: ca. 3470 kg
Suitab le to oven 72 4 / 725 / 726
Max. u sable space 8 20 x 1000 mm
1 troll ey/batch ca. 14 bat ches/hr
Model designation
> Process volume/batch max 200 kg
> 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HW: 22 kW, 400 V,
50 Hz, 3 phase / 52A
> Refrigerating machine 60: 23.3 kW,
400 V, 50 Hz, 3 Phase /63A
Tech nical Data
Chamber weight: ca. 1500 kg
Pump unit: ca. 1070 kg
Cooling unit: ca. 650 kg
Total weight: ca. 3220 kg
Suitab le to oven 2 x 725 / 2 x 7 26
Max. u sable space 8 50 x 1280 mm
2 troll eys/batch ca. 14 ba tches/h r
VCL200W2 - 2 doors
Model designation
> Process volume/batch max 200kg
> 3-component unit: Vacuum chamber
max. 25 m from pump
> Unit: UV16HW: 22 kW, 400 V,
50 Hz, 3 phase / 52A
> Refrigerating machine 60: 23.3 kW,
400 V, 50 Hz, 3 Phase /63A
Tech nical Data
Chamber weight: ca. 1900 kg
Pump unit: ca. 1070 kg
Cooling unit: ca. 650 kg
Total weight: ca. 3620 kg
Suitab le to oven 2 x 725 / 2 x 7 26
Max. u sable space 8 50 x 1280 mm
2 trolleys/batch ca. 14 batches/hr