REVENT RVS50, RVS70, RVS80, RVS90, RVS110 Installation Manual

...
Installation Guide
Read and Save These Instructions
Watch the installation video at:
reventfans.com/install
Questions? Call
1-877-543-8698 (English) or
1-800-615-5439 (French)
Need Help?
1
Table of Contents
Please Read and Save
These Instructions
page 1
page 1-2
page 3
page 4
page 5
page 6
page 7
page 8-13
page 14-19
page 19
page 20
page 21
Table of Contents
Specifications
What’s Inside The Box
Safety Information
Planning Your Installation
Connecting The Duct
Removing Your Old Fan
SheetLock™ Easy Roomside Installation
Installation For New Construction Framing
Care And Cleaning
Frequently Asked Questions
3-Year Limited Warranty
...............
...........
...............
...............
...............
...............
...............
..........
........
.............
.............
.............
Specifications
Duct Exhaust Diameter
Voltage
Frequency
Fan Watts
Air Flow
Fan Weight
Sound
Grille Size
Housing Length*
Housing Width*
Housing Depth*
4 in ( 10.2 cm )
120 V
60 Hz
13 W, 16 W, 20 W
50 CFM, 70 CFM, 80 CFM
5.25 Lbs ( 2.4 Kg )
0.3 Sone, 0.7 Sone, 0.8 Sone
11 x 11 in ( 27.9 x 27.9 cm )
8 3/8” in ( 21.3 cm )
7 7/8” in ( 20 cm )
5 1/8” in ( 13 cm )
RVS50, RVS70, RVS80
*This may require modification of your current opening. Some hand tools required. Power tools may also be necessary.
2
RVS90, RVS110
Duct Exhaust Diameter
Voltage
Frequency
Fan Watts
Air Flow
Fan Weight
Sound
Grille Size
Housing Length*
Housing Width*
Housing Depth*
4 in ( 10.2 cm )
120 V
60 Hz
23 W, 30 W
90 CFM, 110 CFM
6.95 Lbs ( 3.15 Kg )
0.7 Sone, 1.3 Sone
12 5/8” x 12 5/8” in ( 32.1 x 32.1 cm )
9 3/4” in ( 24.8 cm )
9 1/2” in ( 24.1 cm )
6 3/8” in ( 16.2 cm )
*This may require modification of your current opening. Some hand tools required. Power tools may also be necessary.
RVS130, RVS150
Duct Exhaust Diameter
Voltage
Frequency
Fan Watts
Air Flow
Fan Weight
Sound
Grille Size
Housing Length*
Housing Width*
Housing Depth*
6 in ( 15.24 cm )
120 V
60 Hz
34 W, 40 W
130 CFM, 150 CFM
8.6 Lbs ( 3.9 Kg )
1.5 Sone, 1.5 Sone
13 3/8” x 13 3/8” in ( 34 x 34 cm )
10 1/2” in ( 26.7 cm )
10 3/8” in ( 26.4 cm )
7 5/8” in ( 19.4 cm )
*This may require modification of your current opening. Some hand tools required. Power tools may also be necessary.
3
What’s Inside The Box
SHORT BRACKET
(used for new
construction only)
Qty:2
LONG BRACKET
(used for new
construction only)
Qty:1
MANUAL
Qty:1
TEMPLATE
Qty:1
TRIM RING
Qty:1
DAMPER DIRECTION | POSITION
DU REGISTRE | DIRECCIÓN
DE LA COMPUERTA
ELECTRICAL DIRECTION | POSITION
DU CÂBLAGE ÉLECTRIQUE |
DIRECCIÓN ELÉCTRICA
Template fits models:
Gabarit pour modèles | Plantilla adecuada para los modelos: RV90, RVL90, RVH90, RVHL90, RV110, RVL110, RVH110, RVHL110
U.S.A. and International Patents Pending Brevets américains et internationaux en instance | Patentes de EE. UU. e internacionales pendientes
aligning window entaille d’alignement | alineación de ventana
Tape this to the ceiling. Insert jab saw or pencil in slot, and cut or mark. Use template slot to guide saw or pencil.
Fixez ce gabarit au plafond avec du ruban adhésif. Servez-vous de la fente pour marquer avec un crayon ou pour découpe avec une scie pour plaque de plâtre.
Pegue esto en el techo. Inserte una sierra para paneles o lápiz en la ranura y corte o marque. Utilice una plantilla para ranuras para guiar la sierra o el lápiz.
aligning window
entaille d’alignement | alineación de ventana
CUTOUT TEMPLATE, PERFECT CUT EVERY TIME!
GABARIT DE DÉCOUPAGE, POUR UNE DÉCOUPE PARFAITE
PLANTILLA DE RECORTE ¡CORTE PERFECTO SIEMPRE!
Sheetrock Jab Saw Scie pour plaque de plâtre Sierra para placas de yeso
Watch the video
Regardez la vidéo | Ver el video: reventfans.com/install
INSTALLS IN HALF THE TIME
6 TO 4 IN DUCT ADAPTER
(only included with
130 or 150 CFM models)
Qty:1
WIRE NUT
Qty:3
(Canada only)
Installation Guide
Read and Save These Instructions
Watch the installation video at:
reventfans.com/install
Questions? Call
1-877-543-8698 (English) or
1-800-615-5439 (French)
models #RVS50, RVS70, RVS80, RVS90, RVS110, RVS130, RVS150
Need Help?
ROUNDHEAD
WOOD
SCREW
(used for new
construction only)
Qty:6
2-WIRE QUICK
CONNECT
Qty:2
(U.S.A. only)
1/2" x #6
BRACKET
SECURING
SCREW
(used for new
construction only)
Qty:3
3-WIRE QUICK
CONNECT
Qty:1
(U.S.A. only)
FAN
Qty:1
DAMPER
Qty:1
GRILLE
Qty:1
4
Safety Information
1.) WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards, such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d) Ducted fans must always be vented to the outdoors. e) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
2.) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
3.) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
4.) This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit. Do not use unapproved fans over a bathtub or shower that are not approved for that application.
5.) Install ductwork in a straight line with minimal bends.
6.) Use 120 V, 60 Hz for the electrical supply and properly ground the unit. Follow all local safety and electrical codes.
7.) Do not use this fan with any solid-state control device; such as a dimmer switch. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise, as well as increase risk of fire or electric shock.
8.) To reduce the risk of fire or electric shock, do not block air entry grille.
9.) Mount with the lowest moving parts at least 8.2 ft (2.5 m) above floor or grade level.
10.) Never place a switch where it can be reached from a tub or shower.
11.) Not to be installed in a ceiling thermally insulated to a value greater than R50. (This is required for installation in Canada only).
12.) Not for use in cooking areas. (See PAGE 5 for details)
13.) This product must properly connect to the grounding conductor of the supply circuit.
Follow the heating equipment manufacturer’s guideline and safety standards, such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
WARNING: Not suitable for use as a range hood.
CAUTION: For General Ventilating Use Only - Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors.
CAUTION: Do not install in locations where the temperature will exceed 104°F (40°C).
IMPORTANT: Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
NOTE: Make sure duct work size is a minimum of the discharge. Do not reduce. Reducing the duct size can increase fan noise.
IMPORTANT: You may want to consult with a qualified licensed electrician regarding the wiring of your ventilation fan.
WARNING: To reduce the risk of electric shock, please disconnect the electrical supply circuit before servicing.
CAUTION: This product must be properly grounded.
Go to reventfans.com to obtain a copy of this manual.
5
NOTE: If installing in existing construction, you may need to have access to space above and below the installation location.
Cooking Area
do not install above or
inside this area
Cooking
Equipment
Floor
Turning angle too sharp
Too many elbows
Avoid duct shrink
Elbow near the body
Fan
Body
Minimum 18 in ( 45.72 cm )
Planning Your Installation
When installing the ventilation fan in a new construction site, install the main body of the FAN and duct work during the rough-in construction of the building. The GRILLE should be installed after the finished ceiling is in place.
When installing in existing construction, use the provided cutout TEMPLATE for the ceiling. GRILLE edge should overlap finished ceiling.
Not for use in cooking area - see diagram below.
Do not install ventilation fan in areas where the duct work will require configuration as shown.
There are multiple installation configurations possible for this ventilation fan. Not all configurations are shown. If your installation requires a variation other than those shown, consult with a licensed contractor to determine the best installation for your project. If you are replacing an existing fan, ensure that the new FAN will adequately cover the existing opening.
Connecting the Duct
Install a circular duct to outlet and secure it with duct tape or clamps.
Install the duct to the outlet with a gradient 1°~2° to the outside as shown.
The ducting from this FAN to the outside of the building has a strong effect on
the air flow, noise and energy use of the fan. Use the shortest, straightest duct
routing possible for best performance, and avoid installing the FAN with smaller
ducts than recommended. Insulation around the ducts can reduce energy loss
and inhibit mold growth. Fans installed with existing ducts may not achieve their
rated airflow.
For models RVS50, RVS70, RVS80, RVS90, or RVS110, 4 in (10.16 cm) round
is recommended for best performance. For models RVS130 or RVS150,
6 in (15.24 cm) round is recommended for best performance.
Ensure duct joints and exterior penetrations are sealed with caulk or other
similar material to create an air-tight path, to minimize building heat loss and
gain, and to reduce the potential for condensation.
Place/wrap insulation around duct and/or FAN in order to minimize possible
condensation buildup within the duct, building heat loss and gain.
6
INSULATION*
(Place around and
over Fan Housing.)
Seal gaps
around
housing.
ROUND
DUCT*
POWER CABLE*
Seal duct
joints with
tape.
FAN
HOUSING
ROUND
ELBOWS*
ROOF CAP*
(with built-in
damper)
Keep duct runs short.
WALL CAP* (with built-in
damper)
*Purchase
separately.
OR