ResMed Disposable Masks and Circuits User Manual

PRODUCT CODE
ResMed Hospital Full Face Mask (vented)
Small 60703 Medium 60704 Large 60705 Headgear (10 per pack) 60710
ResMed Corp Poway, CA, USA +1 858 746 2400 OR 1 800 424 0737 (toll free), ResMed Ltd, 1 Elizabeth MacArthur Drive Bella Vista NSW 2153 Australia +61 (2) 8884 1000 or 1 800 658 189 (toll free). Offices in Austria, Brazil, Finland, France, Germany, Hong Kong, Japan, Malaysia, Netherlands, New Zealand, Singapore, Spain, Sweden, Switzerland, United Kingdom (see website for details). Hospital Full Face Mask protected by patents: AU 744593, AU 775051, CA 2261790, EP 0956069, EP 1187650, US 6112746, US 6357441, US 6374826, US 6513526, US 6581602, US 6634358, US 6701927, US 7069933. Other patents and design registrations pending. Hospital Nasal Mask patents and design registrations pending. Mirage is a trademark of ResMed Ltd and registered in U.S. Patent and Trademark Office. ©2006 ResMed Ltd. Specifications may change without notice. 1010626/2 06 07
ResMed Hospital Nasal Mask (vented)
Medium 61106 Large 61107 Headgear (10 per pack) 61118
Global leaders in sleep and respiratory medicine www.resmed.com
ResMed Hospital Universal Disposable Bilevel Circuits
Universal Disposable Bilevel Circuit with filter (10 per case) 21952
Universal Disposable Bilevel Circuit (10 per case) 21953
Disposable Masks and Circuits
Quick to fit. Effective to use.
Quick to fit and easy to use, ResMed’s disposable masks and circuits provide cost-effective, time-saving solutions for the clinical environment. Ideally suited for CPAP, bilevel pressure treatment and noninvasive ventilation therapy.
ResMed Hospital Full Face Mask
The proven comfort and seal of ResMed’s Mirage mask is available in three sizes—small, medium and large—providing a comfortable fit for a wide range of patients. Designed for single patient use, the masks can be easily discarded, eliminating cross-contamination concerns and costs associated with mask disinfection and sterilization.
Easy to adjust and quick to fit headgear
Offers the ultimate in convenience and easy setup
360° rotating elbow with swivel
Allows clinician to select most appropriate tube position
Exhalation vent
Provides effective CO
Pressure port
Single port for measuring pressure
ResMed flow generator setting: Mirage Full Face
washout
2
cushion technology in a hospital mask. Quick to fit and easy to adjust, the full face
Silicone dual-wall cushion
Provides stability and superior seal, utilizing ResMed’s Mirage cushion technology
Quick-release headgear clips
Allows quick release of the mask in an emergency
Anti-asphyxia valve (AAV)
Safety valve automatically opens if the flow generator pressure fails, allowing the patient to breathe room air
ResMed Hospital Nasal Mask
ResMed's nasal masks are designed for single patient use. They are available in two sizes—medium and large— providing a comfortable fit for a wide range of patients. The masks can be easily discarded, eliminating cross­contamination concerns and costs associated with mask disinfection and sterilization.
Easy to adjust and quick to fit headgear
Offers the ultimate in convenience and easy setup
Exhalation vents
Provide effective CO2washout
Pressure port
Single port for measuring pressure
ResMed flow generator setting: Standard
ResMed Universal Disposable Bilevel Circuits
The universal bilevel circuits are designed for single patient use only and may be used with ResMed Hospital full face and nasal masks. The circuits are available both with a filter (21952) and without a filter (21953). Each circuit is packaged with three additional components. Please refer to the user’s guide for operating instructions.
Additional components packaged with Bilevel Circuits
360° rotating elbow with swivel
Allows clinician to select most appropriate tube position
Silicone single-wall cushion
Provides a comfortable, reliable and effective seal
Port cap
Pressure sensing port
Saving you money... saving you time
So easy to use, so quick to fit
• Preassembled and ready to use straight from the package
• Color-coded labeling for easy size identification
• Fitting Guide on packaging ensures correct size selection
• Robust one-piece design—no assembly required
• Simple and thoughtful design with minimal adjustment points
Comfortable and effective therapy
• Effective CO
• Reliable therapy
• ResMed sealing
• A broad range of
2
washout
custom-designed for the clinical environment
technology provides optimal comfort, leak-free seal and reduction of pressure sores
cushion sizes offers a comfortable fit
72” Disposable Bilevel Circuit with filter (21952) 72” Disposable Bilevel Circuit (21953)
96” pressure monitoring tubing
extension tubing and T-assembly
Exhalation vent
Inline exhalation port connector 30” “dual” pressure monitoring
Loading...