Renkus-heinz X12, X24, X14 Manual

0 (0)
Renkus-heinz X12, X24, X14 Manual

OWNER'S MANUAL

X12 • X14 • X24

Loudspeaker Controllers

X12 • X14 • X24 OWNER'S MANUAL

Cautions

CAUTION

TO AVOID ELECTRIC SHOCK, DO NOT INSERT FINGERS OR OBJECTS INTO ANY OPENINGS IN THE CABINET

Sicherheitsvorschriften

VORSICHT

UM ELEKTRISCHEN SCHLAG ZU VERMEIDEN, KEINE FINGER ODER GEGENSTÄNDE IN ÖFFNUNNGEN DES GEHÄUSES STECKEN N

WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

Explanation of Graphical Symbols

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the use to the presence of uninsulated "dangerous Voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans.

The exclamanation point,within an equilateral triangle is intended to alert the users to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.

WARNUNG: ZUR VERMEIDUNG VON FEUER ODER ELEKRISCHEN SCHLÄGEN DAS GERÄT NICHT MIT REGEN ODER FEUCHTIGKEIT IN BERÜHRUNG BRINGEN

Erklärung der graphischen Symbole

Der Blitz mit nach untenzielendem Pfeil in einem gleichseitigen Dreieck weist den Benutzer auf das Vorhandensein einer unisolierten, "gefährlichen Spannung" im Gehäuse hin, die stark genug sein kann, einer Person einen gefährlichen elektrischen Schlag zu versetzen.

Das Ausrufezeichen in einem gleichseitigen Dreieck weist den Benutzer auf wichtige Betriebsund Wartungsvorschriften in den beiliegenden Unterlagen des Gerätes hin.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER. NO USERSERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

VORSICHT

GEFAHR EINES ELEKTRISCHEN

SCHLAGES NICHT ÖFFNEN

VORSICHT! UM DAS RISIKO EINES ELEKTRISCHEN SCHLAGES ZU VERMINDERN, ABDECKUNG NICHT ENTFERNEN. KEINE BENUTZER BEDIENUNGSTEILE IM INNERN. BEDIENUNG NUR DURCH QUALIFIZIERTES BEDIENUNGSPERSONAL.

CAUTION

RISK OF ELECTRIC SHOCK: OPEN ONLY IF QUALIFIED AS SERVICE PERSONNEL

VORSICHT

GEFAHR EINES ELEKTRISCHEN SCHLAGES: NUR VON QUALIFIZIEREM WARTUNGSPERSONAL ZU ÖFFNEN

To reiterate the above warnings: servicing instructions are for use by qualified personnel only. To avoid electric shock, do not perform any servicing other than that contained in the Operation Instructions unless you are qualified to do so. Refer all servicing to qualified personnel

Eindrigliche Warnung: Wartungsvorschriften dienen nur der Benutzung durch qualifizieres Personal. Zur Vermeidung eines elektrischen Schlages keine anderen als die in den Betriebsvorschriften beschriebenen Wartungsarbeiten ausführen, es sei denn Sie sind dafür qualifiziert.

Wartungsarbeiten sind nur von qualifiziertem Wartungspersonal auszuführen.

2

X12 • X14 • X24 OWNER'S MANUAL

Table of Contents

Warning Messages

2

Table of Contents

3

Introduction

4

Overview

5

System Wiring Diagrams

 

X12

6

X14

7

X24

8

Plug-In Modules

9

Front Panel Features

 

X12 & X24

10

Status Indicators

10

X14

11

Status Indicators

11

Rear Panel Features

 

X12 & X24

12

Sense Lines

12

X14

13

Sense Lines

13

Set-Up

 

Mounting

14

Cabling

14

Amplifier Selection

14

Sense Connectors

14

Trouble Shooting

15

Technical Specifications

16

3

X12 • X14 • X24 OWNER'S MANUAL

Introduction

Congratulations on your purchase of a Renkus-Heinz loudspeaker controller. It has been designed to provide years of trouble-free, high performance operation. We hope you enjoy it.

The X12, X14 and X24 are a series of loudspeaker controllers designed to be used specifically with speakers produced by Renkus-Heinz. These loudspeaker controllers provide electronic crossovers, equalization, delay, and loudspeaker protection circuitry tailored specifically to a particular model loudspeaker. By using one of these controllers, you are assured of obtaining the optimum in loudspeaker performance and protection.

Caution: The X12, X14 and the X24 are configured for a particular Renkus-Heinz loudspeaker model. Do not use with any other loudspeaker model other than the internally programmed intended loudspeaker model. Use of the wrong loudspeaker model may result in loudspeaker damage.

Your Renkus-Heinz controller was completely tested and inspected before leaving our factory and should have arrived in perfect condition. Please carefully inspect your controller and its shipping carton for any noticeable damage, and if any damage is found, immediately notify the shipping company.

Only the consignee may institute a claim with the carrier for any damage incurred during shipping. Be sure to save the carton and all packing materials for the carrier's inspection.

It is also a good idea to save the carton and packing material even though the controller arrived in good condition. If shipping the controller should ever be required, it should be shipped only in its original factory packing.

Important:

Your Renkus-Heinz controller contains no user-serviceable parts and all service should be referred to qualified service personnel. We recommend that it be returned to the factory in its original packing carton if factory service is required.

4

X12 • X14 • X24 OWNER'S MANUAL

The X12, X1 and the X24 are designed to be all encompassing units. They include crossovers, equalization, time alignment delay, and protective circuitry for specific loudspeakers in a single compact unit. This simplifies system design, reduces racks space requirements and lowers overall system costs.

A block diagram of the X12 controller is shown below in Figure 1. The X14 and X24 controllers are the same, except for the number of channels and/or the number of outputs.

Overview

+

Signal

Diff. Amp

Input

 

 

 

+

Low Freq Diff. Amp

Sense

+

High Freq Diff. Amp

Sense

Low Freq

Low

Delay

Low Freq

Excursion

Peak

Thermal

 

Low

+

High Pass

Frequency

Low Pass

Limiter

Limiter

Limiter/

Diff. Out

 

Circuit

Out

Filter

EQ

Filter

 

 

Sense Fail

 

 

 

 

 

 

High Freq

High

 

High Freq

 

Peak

Thermal

 

High

+

 

 

Diff. Out

 

High Pass

Frequency

 

Low Pass

 

Limiter

Limiter/

 

 

 

Out

Filter

EQ

 

Filter

 

 

Sense Fail

 

Crossover Module

EQ/Delay Module

Crossover Module

 

 

 

 

 

(Part 1)

(Part 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excursion Limiter

 

 

 

 

NOTES

 

 

 

Controller

 

 

 

 

 

 

 

 

 

 

 

 

1. Notice that the Low and High

 

Peak Limiter

 

 

 

 

channels are identical, except for

 

 

 

 

 

the

High channel not having

 

Controller

 

 

 

 

 

 

 

 

 

either a delay circuit or excursion

 

 

 

 

 

 

 

 

 

 

 

 

control.

 

 

 

Thermal Limiter

 

 

 

 

2. The single channel, 4-way

 

Controller

 

 

 

 

X14 is identical to the X12,

 

 

 

 

 

 

except for the X14 having two

 

 

 

 

 

 

low frequency channels and 2

 

 

 

 

 

 

high frequency channels with a

 

 

 

 

 

 

common input.

 

 

 

Peak Limiter

 

 

 

 

3. The two channel, 2-way

 

Controller

 

 

 

 

 

 

 

 

 

 

X24 is two X12's in a common

 

 

 

 

 

 

chassis. i.e., a X12 is one half

 

 

 

 

 

 

of a X24.

 

 

 

Thermal Limiter

 

 

 

 

 

 

 

 

 

Controller

 

 

 

 

 

 

 

 

 

Limit Module

Figure 1: X12 Block Diagram

Each controller is specifically “programmed” for a particular Renkus-Heinz loudspeaker. The model number(s) for the loudspeaker(s) your controller is programmed for are shown on the rear panel.

This “programming” is accomplished using plug-in Crossover, EQ/Delay and Limit modules. This allows the controller to be re-programmed for different loudspeakers by changing modules.

All three controller models use the same circuitry and same plug-in modules. The only difference between the three models is the number of input and output channels.

Model X12 (1 channel 2-way)

The X12 is a single channel 2-way (1 in 2 out) controller designed for use with active 2-way loudspeakers (or 3-way loudspeakers set up for bi-amp operation) in single channel (mono) systems. It is also often used as a "sub controller" and as a controller for passive 2-way loudspeakers. Typical system wiring diagrams for the X12 can be found on the next page.

Model X14 (1 channel 3-way plus sub)

The X14 is a single channel 4-way (1 in 4 out) controller designed for use with active 3-way loudspeakers (plus the possible addition of a subwoofer) in single channel (mono) systems. It is also used with active 2- way loudspeakers in single channel systems having subwoofers. Refer to page 7 for system wiring details.

Model X24 (2 channel 2-way)

The X24 is a dual channel 2-way (2 in 4 out) controller designed for use with two-way loudspeakers in dual channel (stereo) systems. It is also used in stereo systems having 3-way loudspeakers that are set up for biamp operation. Typical system wiring diagrams are shown on page 8.