renishaw TP8 User Guide

User’s guide
H-1000-5118-02-A
TP8 manual indexable probe
© 2006 - 2007 Renishaw plc. All rights reserved.
This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without the prior written permission of Renishaw.
The publication of material within this document does not imply freedom from the patent rights of Renishaw plc.
Disclaimer
Considerable effort has been made to ensure that the contents of this document are free from inaccuracies and omissions. However, Renishaw makes no warranties with respect to the contents of this document and specifically disclaims any implied warranties. Renishaw reserves the right to make changes to this document and to the product described herein without obligation to notify any person of such changes.
Trademarks
RENISHAW® and the probe emblem used in the RENISHAW logo are
registered trademarks of Renishaw plc in the UK and other countries.
apply innovation is a trademark of Renishaw plc.
All other brand names and product names used in this document are trade names, service marks, trademarks, or registered trademarks of their respective owners.
Renishaw part no: H-1000-5118-02-A
Issued: 10 2007
1
TP8
user’s guide
2
Care of equipment
Renishaw probes and associated systems are precision tools used for obtaining precise measurements and must therefore be treated with care.
Changes to Renishaw products
Renishaw reserves the right to improve, change or modify its hardware or software without incurring any obligations to make changes to Renishaw equipment previously sold.
Warranty
Renishaw plc warrants its equipment for a limited period (as set out in our Standard Terms and Conditions of Sale) provided that it is installed exactly as defined in associated Renishaw documentation.
Prior consent must be obtained from Renishaw if non-Renishaw equipment (e.g. interfaces and/or cabling) is to be used or substituted. Failure to comply with this will invalidate the Renishaw warranty.
Claims under warranty must be made from authorised Service Centres only, which may be advised by the supplier or distributor.
Care of equipment
3
Probe trigger force adjustment
1 Probe trigger force adjustment
NOTE: Only increase the stylus trigger force if you encounter
unexpected probe triggers.
The probe trigger force can be adjusted using a 2.5 mm hexagonal wrench. A clockwise rotation increases the trigger force from 0.1 N to 0.3 N approximately. Before leaving the factory, this force is set to
0.12 N based on a 21 mm long stylus fitted with a 4 mm diameter ball tip.
4
TP8 dimensions
100° 100°
75.5 mm
45.25 mm
2 TP8 dimensions
5
3 Specification
Specification summary TP8
PRINCIPAL APPLICATION Robust universal DCC and
manual CMMs.
SENSE DIRECTIONS 5-axis: ±X, ±Y, +Z
UNIDIRECTIONAL REPEATABILITY MAXIMUM (2s µm) (at stylus tip)
0.5 µm (0.00002 in)
PRE-TRAVEL VARIATION 360° (XY PLANE) ±1 µm (±0.00004 in)
WEIGHT (without shank) 95 g (3.36 oz)
STYLUS RANGE M3
STYLUS FORCE RANGE (ADJUSTABLE) 0.11 N - 0.3 N
STYLUS FORCE (SET BY RENISHAW) 0.11 N - 0.13 N
STYLUS OVERTRAVEL (TYPICAL)
XY plane +Z axis
±22°
5.5 mm (0.22 in) @ 0.11 N 2 mm (0.08 in) @ 0.3 N
MOUNTING METHOD Shank
SUITABLE INTERFACE PI 4-2, PI 7-2, PI 200, UCC
Above data applies to test conditions as follows: Stylus length 21 mm (0.83 in). Stylus velocity 480 mm/min (1.57 ft/min). Stylus force 0.11-0.13 N. Ø4 ball.
Specification