Renishaw RVP, H-1000-3322-01-C User Manual

RVP user's guide
Part number: H-1000-3322-01-C
RVP user's guide
www.renishaw.com
Issued 03 2019
1
General information
© 2015 ‐ 2019 Renishaw plc. All rights reserved.
This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without the prior written permission of Renishaw.
The publication of material within this document does not imply freedom from the patent rights of Renishaw plc.
Disclaimer
RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.
Trademarks
RENISHAW® and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries. apply innovation is a trademark of Renishaw plc.
All brand names and product names used in this document are trade names, service marks, trademarks, or registered trademarks of their respective owners.
Windows XP, Windows 2000, Vista, Windows 7 and Windows 10 are registered trade names of the Microsoft Corporation. All trademarks and trade names are acknowledged.
WEEE
The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with the general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help save valuable resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service or Renishaw distributor.
Warranty
Renishaw plc warrants its equipment for a limited period (as set out in our Standard Terms and Conditions of Sale) provided that it is installed exactly as defined in associated Renishaw documentation.
Prior consent must be obtained from Renishaw if non-Renishaw equipment (e.g. interfaces and/or cabling) is to be used or substituted. Failure to comply with this will invalidate the Renishaw warranty.
Claims under warranty must be made from authorised service centres only, which may be advised by the supplier or distributor.
RVP user's guide
www.renishaw.com
Issued 03 2019
2
Care of equipment
Renishaw probes and associated systems are precision tools used for obtaining precise measurements and must therefore be treated with care.
Changes to Renishaw products
Renishaw reserves the right to improve, change or modify its hardware or software without incurring any obligations to make changes to Renishaw equipment previously sold.
Packaging
To aid end user recycling and disposal the materials used in the different components of the packaging are stated here:
Packaging component Material 94/62/EC code 94/62/EC number
Outer box Non-corrugated fibreboard PAP 21 Storage box Polypropylene PP 05 Packaging insert Corrugated fibreboard PAP 20 Stylus box Polypropylene PP 05 Stylus box label Polypropylene PP 05 Bag Low density polyethylene LDPE 04
RVP user's guide
www.renishaw.com
Issued 03 2019
3
Patents
Features of the RVP system and associated products (such as REVO-2), equipment and techniques are the subjects of one or more of the following patents and patent applications:
CA2925301 CN100453970 EP1086354 IN2017/009615 JP2016-513248 US2015-0362311 CN101166951 EP1687589 IN259801 JP2016-533484 US2016-0238373 CN101166953 EP1877727 IN279118 JP2018-514773 US2018-0058884 CN101405563 EP1877732 IN292511 JP2018-522240 US2018-0156608 CN101405564 EP1989504 IN294476 JP4695762 US6633051 CN101490430 EP2002206 IN295786 JP5196356 US7533574 CN101772690 EP2002207 IN296310 JP5350216 US7809523 CN102037309 EP2035719 WO2006/114603 JP5425476 US7861430 CN102305613 EP2140318 WO2007/107776 JP5638517 US7885777 CN102906533 EP2167911 WO2009/141606 JP5653581 US7971365 CN103842766 EP2291606 WO2011/135282 JP5658863 US8006398 CN105190230 EP2431707 WO2014/122438 JP5706158 US8186882 CN105408723 EP2564151 WO2014/191729 JP5851969 US8302321 CN105793695 EP2764324 WO2015/049341 JP6013533 US8425119 CN107532930 EP2954283 WO2018/091867 JP6199870 US8474148 CN107850425 EP3004797 JP6348577 US8511898 EP3052926 US8601701 EP3289314 US8756973 EP3322959 US8978261 US9038282 US9366519 US9618329 US9903713
RVP user's guide
www.renishaw.com
Issued 03 2019
4
Product compliance
EU declaration of conformity
Contact Renishaw plc or visit www.renishaw.com/EU for the full EU declaration.
FCC (USA only)
Information to user (47 CFR 15.105)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
Information to user (47 CFR 15.21)
The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised representative could void the user's authority to operate the equipment.
Equipment label (47 CFR 15.19)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
REACH regulation
Information required by Article 33﴾1﴿ of Regulation ﴾EC﴿ No. 1907/2006 ﴾“REACH”﴿ relating to products containing substances of very high
concern (SVHCs) is available at:
www.renishaw.com/REACH
RVP user's guide
www.renishaw.com
Issued 03 2019
5
Safety
Before unpacking and installing the RVP system, the user should carefully read the safety instructions below and ensure that they are followed at all times by all operators.
The RVP vision probe system should only be used with the REVO-2 head. Operators must be trained in the use and application of the REVO-2 system and accompanying products, in the context of the machine it is
fitted to, before being allowed to operate that machine. Permanent magnets are used in some components of the REVO-2 system and associated products. It is important to keep them away from
items which may be affected by magnetic fields, e.g. data storage systems, pacemakers and watches.
VM10 and VM11 LED emissions
The VM10 and VM11 vision modules incorporate high power LED lights and should not be used in the event of serious damage to any part of the VM10 and VM11 modules. In such cases immediately disconnect the power source, remove and do not attempt to reuse the parts. Contact your supplier for advice.
CAUTION: This equipment uses LED illumination that may flash at a variable rate. Avoid exposure or seek advice from your medical practitioner if you are susceptible to photosensitivity or related health effects.
RVP user's guide
www.renishaw.com
Issued 03 2019
6
Environmental and electrical specifications
Environmental specification
Ambient operating temperature range +10 °C to +40 °C Storage temperature range ‐25 °C to +70 °C ﴾‐13 °F to 158 °F﴿ Operating humidity 0% to 80% (non-condensing) Storage humidity 0% to 80% (non-condensing)
Electrical specification
The REVO-2 head and probe electronics are powered from the UCC S5. The head motors are powered from the SPA3. The VPCP and VMCP are powered by a separate power supply that is supplied by Renishaw. Any additional backlighting is powered by a separate power supply that is supplied by Renishaw. No additional power supplies are required.
RVP user's guide
www.renishaw.com
Issued 03 2019