renishaw RSP3-6 User Manual

Page 1
Renishaw plc
New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR United Kingdom
T +44 (0)1453 524524 F +44 (0)1453 524901 E uk@renishaw.com
www.renishaw.com
RSP3-6 extended reach probe
Enhanced access and inspection capability with RSP3-6
RSP3-6
The RSP3-6 provides enhanced
capability for accessing deep bores
and inspecting features within large
parts. It is available with a range
of stylus holders for applications
requiring straight and cranked
extensions and can be used for
both touch-trigger and 2D scanning
applications.
The other RSP3 probes within
the range (RSP3-1, -2, -3, -4) can
be used for 3-axis scanning with
fixed REVO head angles during
measurement, providing the REVO
system with 3D-scanning (X, Y, Z)
with crank stylus capabilities. It also
allows different lengths of styli to be
used whilst maintaining optimum
metrology performance.
RSH3-6c-500
RSH3-6c-600
RSH3-6-600
Reach
Available with straight extensions up to 800 mm from REVO’s A-axis centre of rotation, and
cranked extensions up to 600 mm from REVO’s A-axis centre of rotation.
RSH3-6-700
RSH3-6-800
Accuracy
Scanning accuracy: Typically better than 10 µm form error (filtered) and 5 µm diameter error
Touch-trigger accuracy: Typically better than 3 µm form and diameter error
Part of the REVO 5-axis multi-sensor system
Long extensions combined with 5-axis movements for better part access, and multi-sensor
changing for increased flexibility.
Page 2
Performance
Scanning of a ring gauge
Form error (F) and diameter error (D)
REVO A-axis
centre of rotation
490 mm
600 mm700 mm800 mm
Test setup criteria
Stylus used
CMM specification
CMM controller
Data filter used
Artefacts used
Scanning speed
Touch speed
Back off speed
Bi-directional
scans
Renishaw’s M2 stylus range
U3 = 3.1 µm + L / 250
UCC2-2
Harmonic simple cut off order
= 60 UPR (undulation values)
Ø45 mm (nom) calibration
sphere (for the calibration)
Ø50 mm (nom) ring gauge (for
the ring gauge tests)
5 mm/s (for the ring gauge
scan tests)
2 mm/s (for the ring gauge
touch tests)
2 mm/s
Bi-directional scan data is
quoted to demonstrate the
performance of the Renishaw
probe calibration method
F = 7 µm
D = 3 µm
F = 7 µm
D = 3 µm
Max
50 mm
590 mm
F = 8 µm
D = 3 µm
F = 9 µm
D = 3 µm
F = 9 µm
D = 3 µm
Page 3
Touch-trigger probing of a ring gauge
Form error (F) and diameter error (D)
EWL = effective working length
EWL 348 mm
F = 2 µm
D = 2 µm
F = 2 µm
D = 2 µm
EWL 456 mmEWL 556 mmEWL 656 mm
EWL 448 mm
F = 3 µm
D = 3 µm
F = 3 µm
D = 3 µm
Max
50 mm
F = 3 µm
D = 3 µm
Page 4
Renishaw plc
New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR United Kingdom
T +44 (0)1453 524524 F +44 (0)1453 524901 E uk@renishaw.com
www.renishaw.com
Specification
132 mm
REVO A-axis
centre of rotation
50.6 mm 173 mm
80.5 mm
Ø46 mm
Probe attributes
Measurement range
Overtravel range
Resolution
Weight
Effective stylus length range
Mounting
Crash protection
Change rack options
Interface options
2-axis scanning (X,Y) and 3-axis touch-trigger (X,Y,Z)
±0.5 mm deflection in all directions in all orientations
X, Y ±2 mm
+Z 1.7 mm
-Z 1.2 mm
Capable of <0.1 µm
300 g (10.58 oz) (excluding stylus holder and stylus)
RSP3-6 + RSH3-6c-500 EWL 348 mm (13.70 in) using M2 star centre
RSP3-6 + RSH3-6c-600 EWL 448 mm (17.64 in) using M2 star centre
RSP3-6 + RSH3-6-600 EWL 456 mm (17.95 in) using 10 mm stylus
RSP3-6 + RSH3-6-700 EWL 556 mm (21.89 in) using 10 mm stylus
RSP3-6 + RSH3-6-800 EWL 656 mm (25.83 in) using 10 mm stylus
Magnetised kinematic coupling
±X, ±Y, -Z Via break out of probe or stylus holder
+Z Via integral bump-stop design
RCP TC-2 For probe changing only
This single port unit mounts to the MRS or MRS2
RCP2 For stylus holder changing only
This single port unit mounts to the MRS or MRS2
UCC2-2 systems
© 2014 Renishaw plc Renishaw reserves the right to change specifications without notice Printed in England 0914
US hybrid part no. H-1000-2123-01-B
Printed in England 0914 Part no. H-1000-2122-01-B