Remotec Z-Wave ZRP-100US User Manual

Page 1
Page 1 of 8
Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL
Introduction
Thank you for choosing ZRP-100 Z-Wave Repeater product! ZRP-100 is a Z-Wave repeater with best RF performance to repeat Z-Wave signals in a network, which will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacle and radio dead spots.
Page 2
Page 2 of 8
Glossary
Key Features
- Supports Network Wide Inclusion (NWI) and Explore Frames
- Reliable and best RF performance to repeat Z-Wave signals
- Ultra-low power consumption
- Complex, thin and small size form factor
- Does not block lower outlet when plugged into upper outlet of a duplex wall receptacle and vice versa
Device/Light/Node
Devices, lights and nodes are all terms to describe an individual Z-Wave device. These are all interchan geable when setting up your Z-Wave network.
Z-Wave Network
A collection of Z-Wave devices is controlled by primary and secondary controllers operating on the same system. A Z-Wave network has its own unique ID code so that controllers not in the network cannot control the system.
Inclusion
Add a Z-Wave device to the network.
Exclusion
Delete a Z-Wave device from the network.
Network Wide Inclusion (NWI)
Network Wide Inclusion (NWI) enables both end-user friendly, Plug and Play like Z-Wave network inst allation as well as professional installation scenario where the inclusion process in terms of time will be reduced significantly. NWI is a feature supported by a new frame type named Explorer which enables the Z-Wave protocol to implement Adaptive Source Routing.
Page 3
Page 3 of 8
Product Overview
A Status LED B PROG Push button C Fixing hole D AC plug
E External fixing insert and screw
A
Installation Location
WARNING: To avoid fire, shock, or death; turn off power at circuit breaker or fuse and test that power is off before dismount or mount the unit by screw! In case you need to mount the unit with screw, please refer to below figures and select your configuration. It is recommended that a qualified electrician perform this installation.
B C D E
Grounded AC outlet with center screw
Un-grounded AC outlet with center screw
Grounded AC outlet with upper and lower screw
Page 4
Page 4 of 8
ZRP-100 will not block lower outlet when plugged into upper outlet of a duplex wall receptacle and vice versa. Below are the illustrations.
Un-grounded AC outlet
with center screw
Grounded AC outlet
with center screw
Grounded AC outlet with
upper and lower screw
Installed at upper AC outlet
Installed at lower AC outlet
Page 5
Page 5 of 8
Z-Wave setup and operations
Z-Wave inclusion and exclusion
Include or exclude the ZRP-100 from the existing Z-Wave home control network with your primary controller.
- Refer to your primary controller instructions to process the inclusion / exclusion setup
procedure.
- When prompted by your primary controller, triple click the PR OG button within 1 se cond
. (The unit will enter classical inclusion/exclusion first then jump to NWI, it will exit NWI mode automatically after 5 seconds if no inclusion/exclusion request.)
- The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful, please repeat the procedure.
All configuration parameters value will keep no change after exclude the unit from network
 
LED Indication Status
Operations LED Indication Status
Device not currently paired into a Z-Wave network
LED keep flashing at 2Hz frequency.
Learning / NWI mode: Triple click on PROG button
LED flashes slowly within 2 seconds then keep in previous on or off stage if it’s already exist in the network.
LED flashes slowly and waiting for Network Wide Inclusion (NWI) if it does not exist in the network, it will exit NWI mode
automatically after 5 seconds. Receive command / Send command or data
LED flashes 2 times then keep in previous on or off stage.
Configure command error LED flashes 6 times rapidly then keep in previous on or off stage.
Restoring Factory Defaults
All Configuration Parameters value can be restored to factory default settings and excluded from network.
Step Setup Key LED Indication Status on ZRP-100
1
Press and keep holding the PROG button not less than 10 seconds.
LED state will toggle at first 5seconds.
LED state will toggle after 10seconds.
2
Release the PROG button then triple click the PROG button within 2 seconds.
LED will keep in previous on or off stage.
Page 6
Page 6 of 8
Wireless Information
Wireless range:
This device has an open-air line-of-sight transmission distance of 30m which complies with the Z-Wave standards. Performance can vary depending on the amount of object s in between Z-Wave devices such as walls and furniture. Every Z-Wave device set up in your network will act as a signal repeater allowing devices to talk to each other and find alternate routes in the case of a reception dead spot. Radio frequency limitations:
1. Each wall or object (i.e.: refrigerator, bookshelf, large TV, etc) can reduce the maximum range of 20m by up to 20 to 30%.
2. Plasterboard and wooden walls block less of the radio signal then concrete, brick or tile walls which will have more of an effect on signal strength.
3. Wall mounted Z-Wave devices will also suffer a loss of range if they are housed in metal junction boxes which could also reduce the range by up to 20 to 30%.
Maintenance
1. Do not expose your unit to dust, strong sunlight, humidity, high temperatures or
mechanical shocks.
2. Do not use corrosive or abrasive cleansers on your unit.
3. Keep the unit dust free by wiping it with a soft, dry cloth.
4. Do not disassemble your unit; it contains no user-serviceable parts.
Technical Specifications
Model no.
BW8140US (ZRP-100US)
RF frequency
908.42MHz
Input voltage / frequency
120Vac / 60Hz
Input power and current
0.3W / 7mA @ 120Vac
RF operating distance
up to 30m (line of sight between the Wireless Controller and the closest Z-Wave receiver module at open area)
Dimension (L x W x T)
64 x 48 x 23mm
Weight
50g
Storage Temperature
-10~60
o
C
Operation Temperature
0~40
o
C
Relative Humidity:
5~95%
Environment
Indoor use only
Note: Specifications subject to change without notice due to continuing product improvement.
Page 7
Page 7 of 8
Certifications
UL Listed: This power unit is intended to be correctly orientated in a vertical or floor mount position. FCC Information
FCC ID : TBD This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Notice : Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment.
IC information
IC : TBD This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This device complies with RSS-310 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference
Page 8
Page 8 of 8
Warnings
- Do not modify the unit in any way.
- Risk of fire.
- Risk of electrical shock.
- Risk of burns.
- This unit never got qualified certificate to supply power for medical instrument or any life support equipment.
- Do not dispose of electrical appliances and unsorted municipal waste, use sep arate collection facilities. Contact your local government for information regarding the collection systems available.
- There is no user serviceable parts in this unit.
Warranty
ONE-YEAR LIMITED WARRANTY: Remotec warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the original date of purchase from the distributor or dealer.
REMOTEC shall not be liable for:
- damages caused by defective devices for indirect, incidental, special, consequential or punitive damages, including, inter alia, loss of profits, savings, data, loss of benefits, claims by third parties and any property damage or personal injuries arising from or related to the use of the device.
- Service trips to provide instruction on product use.
- Shipping costs for replacement products.
This warranty is limited to the repair or replacement of this product only, if the purchase date cannot be substantiated, the warranty period will begin on the date of manufacture as indicated on this product. All warranty claims must be made to Remotec appointed distributors or dealers during the applicable warranty period. This warranty gives you specific legal right and you may also have other rights which vary in each country.
Please contact Customer Service at: Zwave Products, 111 roosevelt Ave Westwood NJ 07675 email: Sales@zwaveproducts.com
www.zwaveproducts.com
Printed in China F820-8140-0000