Page 5 of 8
Z-Wave setup and operations
Z-Wave inclusion and exclusion
Include or exclude the ZRP-100 from the existing Z-Wave home control network with your
primary controller.
- Refer to your primary controller instructions to process the inclusion / exclusion setup
procedure.
- When prompted by your primary controller, triple click the PR OG button within 1 se cond
.
(The unit will enter classical inclusion/exclusion first then jump to NWI, it will exit NWI
mode automatically after 5 seconds if no inclusion/exclusion request.)
- The primary controller should indicate that the action was successful. If the controller
indicates the action was unsuccessful, please repeat the procedure.
All configuration parameters value will keep no change after exclude the unit from network
LED Indication Status
Operations LED Indication Status
Device not currently paired into
a Z-Wave network
LED keep flashing at 2Hz frequency.
Learning / NWI mode:
Triple click on PROG button
LED flashes slowly within 2 seconds then keep in previous on or
off stage if it’s already exist in the network.
LED flashes slowly and waiting for Network Wide Inclusion (NWI)
if it does not exist in the network, it will exit NWI mode
automatically after 5 seconds.
Receive command /
Send command or data
LED flashes 2 times then keep in previous on or off stage.
Configure command error LED flashes 6 times rapidly then keep in previous on or off stage.
Restoring Factory Defaults
All Configuration Parameters value can be restored to factory default settings and excluded
from network.
Step Setup Key LED Indication Status on ZRP-100
1
Press and keep holding the PROG
button not less than 10 seconds.
• LED state will toggle at first 5seconds.
• LED state will toggle after 10seconds.
2
Release the PROG button then triple
click the PROG button within 2
seconds.
• LED will keep in previous on or off stage.