Read instructions manual before use.
Lesen Sie die Bedienungsanleitung vollstän-
dig durch, bevor Sie das Gerät das erste Mal
benutzen.
Lees voor gebruik deze gebruiksaanwijzing.
Lisez les instructions avant utilisation.
Lea el manual de instrucciones antes del uso.
Leggere il manuale di istruzioni prima dell’uso.
Antes de utilizar o aparelho, leia o manual de
instruções.
Do not use on the face.
Nicht im Gesicht anwenden.
Niet op het gezicht gebruiken.
Ne pas utiliser sur le visage.
No utilice el aparato en el rostro.
Non usare sul viso.
Não utilize no rosto.
Do not use near water.
Nicht in der Nähe von Wasser anwenden.
Niet gebruiken in de buurt van water.
Ne pas utiliser près d’une source d’eau.
No utilice el aparato cerca del agua.
Non usare in prossimità dell’acqua.
Não utilize perto de água.
i-Light is a home-use device for the reduction of body hair using Intense
Pulsed Light (IPL) technology. This is the same technology used in professional hair
removal salons and clinics. If used correctly it can provide long-lasting
hair reduction.
What is Intense Pulse Light (IPL) and how does the i-Light work?
i-Light works by directing an extremely short, intense pulse of light into the skin. The
light energy is absorbed by the melanin in the hair follicle temporarily disabling the
growth mechanism in the hair and delaying hair growth.
Hair follicles typically pass through three phases throughout the hair growth cycle.
These phases are:
Anagen Phase (growing phase) – the active growth phase of the hair follicles.
Melanin concentration is at its highest as it is responsible for pigmentation of the hair.
Only hairs in the anagen phase are susceptible to treatment with IPL (fig. 2).
Catagen Phase (degradation phase) – this is a short transition stage, which follows
the anagen phase and signals the end of active growth of hair. It typically lasts 2-3
weeks (fig. 3).
Telogen Phase (resting phase) – the hair follicle is completely at rest during this
phase, which is the longest phase and lasts about 100 days. During this time, the new
Getting Acquainted With i-Light
hairs push out the old hairs, allowing the growth cycle to begin again (fig. 4).
What to expect from i-Light
Our studies have shown significant hair reduction after only a single treatment.
However, optimal results are generally not obtained with a single session. For best
results, repeat a treatment session whenever you notice hair starting to
regrow. Results vary by individual, however, most will re-treat areas every two weeks
for three treatments until desired results are achieved.
A few days after the first treatment you may start to notice hair has fallen out.
Some hair growth will occur that is less dense, finer and lighter in color than the origi-
nal hair. This regrowth is perfectly normal and should be expected.
■ Do not use if you have a skin disease such as active skin cancer, if you have a
history of skin cancer or any other localized cancer in the areas to be treated, or if
you have pre-cancerous lesions or multiple atypical moles in the areas to be treated.
■ Do not use if you have epilepsy with flashlight sensitivity.
■ Do not use if you have a history of collagen disorder, including a history of keloid
scar formation or a history of poor wound healing.
■ Do not use if you have a history of vascular disorder, such as the presence of
varicose veins or vascular ectasia in the areas to be treated.
■ Do not use if your skin is sensitive to light and causes a rash or an allergic reaction.
If you are taking photosensitizing agents or medications, check the package insert
of the medicine. Never use the unit if it can cause photo-allergic reactions or phototoxic reactions, or if you should avoid sun while taking a medication.
■ Do not use if you have diabetes, lupus erythematodes, porphyria or congestive heart
disease.
■ Do not use on areas of your skin which are currently being treated with or have
recently been treated with Alpha Hydroxy Acids (AHAs), Beta Hydroxy Acids (BHAs),
topical isotretinoin and azelaic acid.
■ Do not use if you have taken oral isotretinoin Accutane or Roaccutane in the last
six months. This treatment can make skin more susceptible to tears, wounds and
irritations.
■ Do not use if you have any bleeding disorder or take anticoagulation medications,
including heavy use of aspirin, in a manner which does not allow for a minimum
1-week washout period prior to each treatment.
■ Do not use if you have infections, eczema, burns, inflamed follicles, open lacerations,
abrasions, surgeries, herpes simplex, wounds or lesions and haematomas in the
areas to be treated.
■ Do not use if you have a history of immunosuppressive disease (including HIV
infection or AIDS) or if you take immunosuppressive medications.
■ Do not use when you are on painkillers, which reduce the sensitivity to heat.
■ Do not use if you use long-lasting deodorants. This can result in skin reactions.
■ Do not use over or near anything artificial such as silicon implants, Implanon
contraceptive implants, pacemakers, subcutaneous injection ports (insulin dispenser)
or piercings.
IMPORTANT SAFETY INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF BURNS, ELECTROCUTION, FIRE,
OR INJURY TO PERSONS:
As with most electrical appliances, electrical parts are electrically live even when the
switch is off. To reduce the risk of injury or death by electric shock:
■ Always unplug the unit from the electrical outlet immediately after using.
■ Do not use near water.
■ Do not place or store this appliance where it can fall or be pulled into a tub or sink.
■ Do not place or drop into water or other liquid.
■ Do not reach for the unit if it has fallen into water or other liquid. Unplug unit
immediately.
■ Do not reach for the unit if it has become wet. Unplug unit immediately.
■ Unplug the unit before cleaning it.
■ Keep the unit dry at all times.
■ If you move the unit from a very cold to a very warm environment, wait approximately
2 hours before using it.
■ An appliance should never be left unattended when plugged into a power outlet.
■ Keep the power plug and cord away from heated surfaces.
■ Make sure the power plug and cord do not get wet.
Warnings and Safety Precautions
■ Do not plug or unplug the unit with wet hands.
■ Do not use the product with a damaged cord. A replacement can be obtained via
the Remington
■ Use and store the product at a temperature between 15°C and 35°C.
■ Always unplug from the mains when cleaning.
■ Only use the parts supplied with the appliance.
■ Keep this product out of reach of children. The use of this appliance by persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge can give cause to hazards. Persons responsible for their safety should
give explicit instructions or supervise the use of the appliance.
Familiarize yourself with the features of your new i-Light device.
Flash Window (fig. 1-D)
The Flash Window is a filtered glass window with built-in UV protection that allows specific wavelengths of light to pass from the hand piece to your skin and hair follicles.
WARNING: Always inspect the Flash Window before use to ensure there is no
WARNING: Always clean the Flash Window before use with the lint-free cloth
Skin Contact Sensor
The Skin Contact Sensor is a safety mechanism that prevents the device from accidental activation. In order for the device to activate, the Skin Contact Sensor must be fully
depressed against the skin.
damage to the lens.
provided to ensure there is no oil or debris on the lens.
The Flash Button is located on the hand piece. To activate the flash bulb, ensure the Skin
Contact Sensor is fully engaged and press the Flash Button.
Bulb Status Indicator Display
The device is ready to flash when the Bulb Status Indicator Display is illuminated green.
NOTE:
If the Flash Button is pressed AND the Skin Contact Sensor is not fully engaged
OR the Bulb Status Indicator Display is not illuminated, an audible “beep” will
sound.
When the Bulb Status Indicator Display
in the flash bulb. When the Bulb Status Indicator Display
has been used up and will no longer operate. You must replace the bulb cartridge to
Preparing for Use
continue using the device.
Nose Cone Release Buttons
Press both buttons and gently pull to remove the nose cone.
WARNING: ALWAYS ensure the unit is OFF and the power cord is disconnected
before removing the nose cone. If the nose cone is removed while the
unit is powered ON, all indicator lights on the base unit will flash and
audible “beeps” will sound.
Each light cartridge has a life of 1,500 flashes. When all flashes have been used, the
cartridge must be replaced.
Replacement model: SP-IPL
Intensity Level Selection
The i-Light device is equipped with 5 intensity levels. Level 1 is the lowest setting and level
5 is the highest setting.
TIP: For the most effective results, always use the highest intensity level that does
not cause discomfort on the skin. To determine the intensity level being used,
observe the number of lights illuminated on the Intensity Level Selection
Display.
Your i-Light device will automatically be set to Intensity Level 1 each time the device is powered ON. To change the level, press the Intensity Level Selection Button.
Flash Mode Selection (fig. 1-N)
The i-Light device is equipped with two operating modes: Single Flash Mode and MultiFlash Mode. Your i-Light device will automatically be set to Single Flash Mode each time
the device is powered ON.
Single Flash Mode: The i-Light device will flash once when the Flash Button is
pressed AND the skin contact sensor is engaged.
Multi-Flash Mode: The i-Light device will flash once every two seconds when the
Flash Button is pressed AND the skin contact sensor is fully engaged.
The Multi-Flash Mode allows you to quickly treat large areas such as the legs, chest or
back by simply gliding the hand piece to a new location after each flash.
The Multi-Flash Mode allows you to quickly treat large areas such as the legs,
chest or back by simply gliding the hand piece to a new location after each
flash.
To turn Multi-Flash Mode ON, press the Multi-Flash Mode Selector Button. The MultiFlash Mode Selector Display will illuminate. Press again to turn Multi-Flash Mode OFF
and return to Single-Flash Mode.
2. Familiarize yourself with the features of the i-Light device.
3. Consult the Skin Tone Chart to ensure your skin color is in the
acceptable range.
4. Test the i-Light device on a small patch of skin and wait 48
hours to ensure there are no adverse reations.
5
]
Treat desired area(s) with the i-Light device
Prepare your skin for treatment
1. Ensure the area to be treated is clean and free from oils,
deodorants, perfume, make up, lotions and creams. Shave the
hair from the area to be treated.
Getting Acquainted With i-Light
Getting Acquainted With i-Light
2. Never use wax, epilation, tweezers, or depilation products to
remove the hair because they counteract the IPL process.
Prepare the device for treatment
3. Unwrap the hand piece cord from the i-Light base and rest
the hand piece in the base cradle. Locate the power switch
on the i-Light base and ensure the unit is OFF. Connect the
power cord to the i-Light base at the power inlet. Connect the
power cord to the wall outlet. Turn the power switch ON
(fig 6).
4. Select the desired Intensity Level. If the Multi-Flash Mode is
desired, turn ON using the Flash Mode Selector Button (fig 7).
Treat desired area(s) with the i-Light device –
Single Flash Mode
1. Place the i-Light hand piece against your skin so the Flash
Window is flush with the skin surface (fig. 8).
2. Ensure the Skin Contact Sensor is fully engaged and the Bulb
Status Indicator Display is illuminated.
3. Press the Flash Button to activate the device (fig. 9).
4. Move the hand piece to a new treatment area and repeat
steps 1-3 (fig. 10).
GB
8
]
Treat desired area(s) with the i-Light device –
Multi Flash Mode
1. Place the i-Light hand piece against your skin so the Flash
Window is flush with the skin surface (fig. 8).
2. Ensure the Skin Contact Sensor is fully engaged and the Bulb
Status Indicator Display is illuminated.
3. Press AND HOLD the Flash Button down to activate the
device (fig. 9).
4. Immediately after the device has flashed, slide the hand piece
to a new location. After a short delay (approximately
2 seconds) the device will flash again (fig. 10).
NOTE:■ During Multi-Flash Mode, the Skin Contact Sensor
AND the Flash Button must remain fully depressed.
If either becomes disengaged, the device will not
operate. To resume treatment, repeat steps 1-4.
■ During Multi-Flash Mode, the Bulb Status Indicator
Display will remain illuminated while the Skin
Contact Sensor and Flash Button are engaged.
■ For best results, avoid overlapping flashes. This helps prevent exposure to more energy
than is necessary to suppress hair growth. It also ensures that you get the maximum use
of the light cartridge.
■ For the most effective results, always use the highest intensity level that does not cause
discomfort on the skin. The level you use should feel warm on your skin, but should never
cause discomfort.
■ Optimal results are generally not obtained with a single session. For best results, repeat a
treatment session whenever you notice hair starting to regrow. Results vary by individual,
however, most people will treat areas every two weeks for the first three treatments, until
desired results are achieved.
■ You may notice that bony areas, such as elbows, shins, and ankles, are more sensitive
during treatment. This is normal and should not be cause for alarm. To avoid this
sensitivity, try stretching the skin away from the bony area during treatment.
Post-Treatment Care
After treatment, you may experience slight redness or a warm sensation on your skin. This
is normal and will disappear quickly. To avoid irritation to your skin after a treatment, take the
following precautions:
■ Avoid sun exposure for 24 hours after a treatment. Protect the skin with SPF 30 for 2
weeks after each treatment.
■ After treatment, keep the area clean and dry and drink plenty of water to keep skin
hydrated.
■ Do not handle the treated area roughly.
■ Do not take hot baths, showers, or use steam rooms and saunas for 24 hours after
Post Treatment Care / Treatment Tips
treatment.
■ Do not swim for 24 hours after treatment.
■ Do not take part in contact sports for 24 hours after treatment.
■ Do not wear tight-fitting clothing over the treated area.
■ Do not prolong sun exposure such as sunbathing, using a tanning bed, or self-tan for at
■ Do not depilate (waxing, plucking, threading or creams) during the treatment – shaving is
acceptable as long as you avoid shaving 24 hours after each treatment.
■ Do not use bleaching creams or perfumed products for 24 hours after treatment.
■ Do not scratch or pick at the treated area.
Cleaning Your i-Light Device
CAUTION: Before cleaning your i-Light device, make sure that the power switch is OFF and the
■ Regular cleaning helps to ensure optimal results and a long life for the i-Light device.
■ To clean the Flash Window, use only the lint-free cloth included with your i-Light device.
■ For stubborn stains, use a dampened cotton swab to apply a small amount of water to
■ Use a small hand-held vacuum to remove dust and debris from the hand piece vents.
power cord is disconnected from the base unit.
The exterior surface of the base unit and hand piece may be wiped clean with a slightly
damp cloth.
Take care not to scratch or chip the Flash Window. Scratches and chips can reduce the
effectiveness of the unit.
the Flash Window and clean with the lint-free cloth provided.
WARNING: If the Flash Window is cracked or broken, the unit must not be used.
CAUTION: The i-Light is a high voltage device. Never immerse in water. Never
Do not use petroleum-based or flammable cleaning agents because
Never scratch the filter glass or the metallic surface inside the Nose
Cone.
clean the unit or any of its parts under the tap or in the dishwasher.
of the risk of fire. Never use scouring pads, abrasive cleaning agents
or aggressive liquids such as oil or acetone to clean the unit.
Before performing maintenance on your i-Light device, ensure that the power
switch is OFF and the power cord is disconnected from the base unit.
Replacing the bulb
1. Press the nose cone release buttons and gently pull to remove the nose cone.
2. Gently pull out the old bulb cartridge.
3. Replace with a new bulb cartridge. Replacement model: SP-IPL
CAUTION: When replacing the bulb cartridge, do not touch the flash bulbs directly
as this leaves oils and residue. Doing so could reduce the effectiveness
4. Replace the nose cone, making sure it snaps into place.
of the bulbs or cause them to crack during treatment.
Storage
■ Switch off the unit, unplug it and let it cool down for 10 minutes before storage.
■ Store the unit in a dry place at a temperature between 15º C and 35º C.
Troubleshooting
Always read these instructions fully before using i-Light.
Refer to this troubleshooting guide if you experience any problems with i-Light, as this sec-
tion addresses the most common problems you could encounter with i-Light.
If you have followed the instructions in this section and continue to experience problems,
please contact the Remington
Troubleshooting / Storage / Maintenance
I turn the power switch ON, but the unit is not working.
■ Make sure the unit is plugged into a working electrical outlet.
■ Try switching to a different outlet.
The unit appears to have cracks or is broken.
■ Do not use if the unit is damaged. If you have concerns about using the unit,
I have switched the unit ON, but I cannot increase or decrease the light intensity.
■ Try resetting the unit by turning it off and waiting several seconds before turning it
back on.
The Bulb Status Indicator Light turns green but the unit does not flash when the
button is pressed.
■ Make sure the Skin Contact Sensor is in full contact with the skin.
■ Try resetting the unit by turning it off and waiting several seconds before turning it
back on.
There is a strange smell.
■ Be sure the area is completely shaved before treatment.
The treated areas become red after treatment.
■ This is normal and the redness should subside. If not, try using a lower light intensity.
I have not seen optimal results or hair has begun to grow back.
■ Hair may begin to grow back after your initial treatment. This is perfectly normal. For
optimal results, repeat the treatment when you notice hair regrowth.
Q. What is i-Light? What is Intense Pulse Light (IPL)?
A. IPL works by directing an extremely short, intense pulse of filtered light into the skin. The
light is absorbed by the colored pigments in and surrounding the hair and disables the
hair follicle temporarily, preventing hair regrowth.
Q. Who can use i-Light?
A. Both men and women can use i-Light to remove unwanted hair anywhere below the
neck. i-Light has been designed for individuals with light to medium skin tones and dark
hair. Safe skin tones include white, ivory, tan, beige, and light brown only. Safe natural hair
colors include black, dark brown, and medium brown.
Q. What areas of my body can I treat with i-Light?
A. i-Light is designed to be used on areas below the neck, including the legs, underarms,
bikini line, arms, chest and back.
Q. What can I expect from i-Light?
A.
i-Light provides safe and effective salon-grade hair removal using IPL
technology.
Q. What are the risks involved with i-Light? Is it safe?
A. i-Light is safe to use, but like any electronic device it is important that you read and follow
the operating instructions.
Q. How often should I use i-Light?
A. You should use i-Light whenever you start to see hair regrowth.
Q. How long do treatments take?
A. Time varies based on the size of the area being treated, but one full leg should take no
more than 15 minutes.
Q. When will I begin to see results?
A. Results are not immediate. Hair may sometimes appear to be growing back after treat-
ment but many of these hairs will begin to fall out after two weeks. Hair grows in a cycle
of 3 different phases which lasts 18-24 months. Only hairs in the anagen phase are
Frequently Asked Questions
susceptible to treatment, which is why multiple treatments are required for optimal results.
The results are generally noticeable within a few weeks of the first treatment. Continuous
regular weekly (or every 2 weeks for three treatments) use will give good results within 6 to
12 weeks (darker skin may take longer).
Q. Why is my hair growing despite treatments?
A. Hair continues to grow for up to 2 weeks after treatment, at which time you will notice the
hair beginning to fall out. Another reason for continued growth could be that the area was
missed during a treatment. Continue to treat the area whenever you notice regrowth.
Q. Why can’t I use i-Light after recent sun exposure?
A. Sun exposure causes high levels of melanin to be present and exposes the skin to higher
Q. What are the warnings against using i-Light?
A. Certain conditions may limit your ability to use the unit. Please read the Warnings and
Safety Precautions section in the User Manual in its entirety before using i-Light.
Q. How often do I need to replace the bulb?
A. The bulb needs to be replaced after 1500 flashes. The Bulb Status Indicator Light will
illuminate green for the first 1350 flashes of the cartridge life. It will turn to a yellow light to
designate that only 150 flashes remain. When the light begins to flash the cartridge life is
up and you must replace the bulb.
Replacement model: SP-IPL
Q. Can I use i-Light on my face?
A. No. i-Light is not recommended for use on the face or the neck.
Q. How do I care for treated areas following treatment?
A. Avoid unprotected sun exposure to the treated areas.
Q. Should I suspend normal activity after using i-Light?
A. There is no need to suspend normal activity following treatment assuming no abnormal
complications occur. It is recommended that you perform the treatment prior to going to
bed so that any resulting redness fades by morning.
Q. Is i-Light dangerous for the skin after long term use?
A. There have not been any reported side effects or skin damage from long-term use of
intense pulse light.
Q. How often should I treat with i-Light?
A. An interval of 2 weeks for the initial treatment, is proven to be the most effective in hair
reduction. You should avoid treating the same area multiple times in one session, as it will
not improve efficacy but increases the risk of skin irritation.
Q. Can I use i-Light if I have blonde, red, gray or white hairs?
A. i-Light works best on darker hair types because they contain more melanin, the pig-
ment that gives hair and skin its color. Melanin is what absorbs the light energy used
during i-Light treatment. Black and dark brown hairs respond the best. Brown and light
brown hairs will also respond, but typically require more treatments. Red hairs may show
some response. White, grey or blonde hairs usually don’t respond to i-Light treatments,
although some users have noted results after multiple treatments.
Q. Can I use i-Light if I have naturally dark skin?
A. No. i-Light is designed to react with the dark pigment of the hair. As a result, dark brown
and black skin may absorb too much of the device’s energy (heat), which may cause
skin damage. Do not use i-Light on naturally dark skin, as it contains too much melanin.
Treating dark skin with i-Light can result in burns, blisters and skin color changes (hyperor hypo-pigmentation). Review the skin color chart on page 3 to determine if i-Light is
right for you.
Q. Do I need eye protection while using i-Light?
A. No, it is not harmful to the eyes, unless it is directed to the face. i-Light features a safety
system which prevents unintentional flashing when the device is not in contact with the
skin. The small amount of light emitted during treatment is similar to that of a camera flash
and is not harmful to the eyes, unless it is directed to the face.
Frequently Asked Questions
Q. Can I use i-Light if I am pregnant or nursing?
A. No. i-Light has not been tested on pregnant women, therefore we do not recommend
using i-Light if you are pregnant or breast feeding. Hormonal changes could increase sensitivity and the risk of injury to the
You can use this skin-type chart for self-assessment, by adding up the score for each of the
questions you’ve answered. At the end there is a scale providing a range for each of the six
skin-type categories. Following the scale is an explanation of each of the skin types. You can
quickly and easily determine which skin type you are.
Genetic Disposition
Score01234
What is the
colour of
your eyes?
What is
the natural
colour of
your hair?
What is
the colour
of your
skin (non
exposed
areas)?
Do not dispose the product in household waste at the end of its useful life.
Disposal can take place at the Remington
collection sites.
For further information on recycling see www.remington-europe.com,
www.remington-ilight.com
®
Service Centre or appropriate
SERVICE & WARRANTY
This product has been checked and is free of defects. We warrant this product
against any defects that are due to the faulty material or workmanship for a 2
year period from the original date of consumer purchase. If the product should
become defective within the warranty period, we will repair any such defect or
elect to replace the product or any part of it without charge provided there is
proof of purchase. This does not mean an extension of the warranty period.
In the case of a warranty simply call the Remington
region.
This warranty is offered over and above your normal statutory rights.
The warranty shall apply in all countries in which our product was sold via an
authorised dealer.
This warranty does not include replacement bulbs which are consumable parts.
Also, not covered is damage to the product by accident or misuse, abuse,
alteration to the product or use inconsistent with the technical and/or safety
instructions required.
This warranty shall not apply if the product has been dismantled or repaired by
a person not authorised by us.
i-Light ist ein Gerät zur Entfernung von Körperbehaarung. Es setzt die Intense Pulsed
Light (IPL)-Technologie für die Anwendung zu Hause ein. Dies ist die gleiche Technik,
die in der professionellen kosmetischen Haarentfernung und in Kliniken eingesetzt
wird. Bei sachgemäßer Anwendung ermöglicht es eine dauerhafte Reduzierung der
Körperbehaarung.
Was genau ist Intense Pulse Light (IPL) und wie wirkt das
i-Light?
i-Light wirkt, indem ein extrem kurzer, intensiver Lichtimpuls in die Haut geschickt wird.
Diese Lichtenergie wird durch das Melanin im Haarfollikel absorbiert. Dabei wird der
Wachstumsmechanismus vorübergehend außer Kraft gesetzt und das Haarwachstum
wird aufgehalten.
Die Haarfollikel durchlaufen in ihrem Wachstumszyklus in der Regel drei Phasen des
Haarwachstums:
Anagen-Phase (Wachstumsphase) – die aktive Wachstumsphase der Haarfollikel.
Da sie für die Pigmentierung der Haare verantwortlich ist, ist die Melaninkonzentration
jetzt am höchsten. Eine IPL-Behandlung ist nur in der Anagen-Phase der Haare wirksam (Abb. 2).
Katagen-Phase (Übergangsphase) – eine kurze Übergangsphase, die auf die AnagenPhase folgt und das Ende des aktiven Haarwachstums anzeigt. Sie dauert in der Regel
2 bis 3 Wochen (Abb. 3).
Die Telogen-Phase (Ruhephase) – während dieser Phase befindet sich das
Haarfollikel in einer vollständigen Ruhephase. Sie ist mit ca. 100 Tagen die längste
Phase. Während dieser Zeit schieben die neuen Haare die alten heraus, so dass der
Machen Sie sich mit i-Light vertraut
Wachstumszyklus wieder von neuem beginnen kann (Abb. 4).
Was i-Light leisten kann
Unsere Studien haben eine erhebliche Reduzierung der Körperbehaarung bereits nach nur
einer Anwendung nachgewiesen. Allerdings können mit nur einer Sitzung keine optimalen
Ergebnisse erzielt werden. Um optimale Ergebnisse zu erzielen, wiederholen Sie die Behandlung, sobald Sie ein erneutes Haarwachstum feststellen. Die Ergebnisse können individuell unterschiedlich ausfallen. Jedoch sollten die behandelten Bereiche alle zwei Wochen
insgesamt drei Mal nachbehandelt werden, um die gewünschten Ergebnisse zu erzielen.
Einige Tage nach der ersten Behandlung werden Sie feststellen können, dass Haare ausgefallen sind. Es können Haare nachwachsen, die weniger dicht, feiner und in der Farbe heller
26
sind als das ursprüngliche Haar. Dieses Nachwachsen ist absolut normal und zu erwarten.
■ Nicht anwenden, wenn Sie eine Hauterkrankung wie einen aktiven Hautkrebs haben,
wenn Sie eine Vorgeschichte mit Hautkrebs haben oder einen anderen Krebs, der
sich in den zu behandelnden Bereichen befindet, oder wenn Sie Krebsvorstufen
haben oder mehrere atypische Leberflecke in den zu behandelnden Bereichen.
■ Nicht anwenden bei Epilepsie mit einer Überempfindlichkeit gegen Blitzlicht.
■ Nicht anwenden, wenn Sie eine Vorgeschichte mit Kollagenstörungen, einschließlich
Narbengeschwürbildung, oder eine Vorgeschichte mit schlechter Wundheilung haben.
■ Nicht anwenden, wenn Sie eine Vorgeschichte mit Gefäßstörungen haben, wie
Krampfadern oder Gefäßektasie in den zu behandelnden Bereichen.
■ Nicht anwenden bei Lichtüberempfindlichkeit mit Ausschlag oder allergischen
Reaktionen. Wenn Sie lichtsensibilisierende Wirkstoffe oder Medikamente verwenden,
prüfen Sie die Packungsbeilage des Medikaments. Wenden Sie das Gerät nie an,
wenn es photoallergische oder phototoxische Reaktionen hervorrufen kann, oder
wenn Sie während der Einnahme eines Medikaments Sonnenlicht meiden müssen.
■ Nicht anwenden, wenn Sie unter Diabetes, Lupus Erythematodes, Porphyrie oder
kongestiver Herzerkrankung leiden.
■ Nicht auf Bereichen Ihrer Haut anwenden, die in letzter Zeit oder aktuell mit AlphaHydroxy-Säuren (AHAs), Beta-Hydroxy-Säuren (BHAs), Isotretinoin zur Anwendung
auf der Haut oder Azelainsäure behandelt wurden/werden.
■ Nicht anwenden, wenn Sie Isotretrinoin Accutane oder Roaccutane in den letzten 6
Monaten oral eingenommen haben. Diese Behandlung kann Ihre Haut empfindlicher
für Risse, Wunden und Reizungen machen.
■ Nicht anwenden, wenn Sie Blutungsstörungen haben oder koagulationshemmende
Medikamente einnehmen, einschließlich der massiven Anwendung von Aspirin in der
Weise, dass eine Mindest-Auswaschphase von 1 Woche vor jeder Behandlung nicht
eingehalten werden kann.
■ Nicht anwenden, wenn Sie Infektionen, Ekzeme, Verbrennungen, entzündete
Haarfollikel, offene Risswunden, Schürfwunden, Operationswunden, Herpes Simplex,
Wunden oder Läsionen und Hämatome in den zu behandelnden Bereichen haben.
■ Nicht anwenden, wenn Sie eine Vorgeschichte mit immunsuppressiven Erkrankungen
(einschließlich HIV-Infektion oder AIDS) haben oder wenn Sie immunsuppressive
Medikamente einnehmen.
■ Nicht anwenden, wenn Sie Schmerzmittel nehmen, da diese die Hitze-Empfindlichkeit
herabsetzen.
■ Nicht anwenden, wenn Sie lang anhaltende Deodorants benutzen. Dies kann
Hautreaktionen hervorrufen.
■ Nicht anwenden über oder in der Nähe von künstlichen Elementen wie SilikonImplantaten, Implanon-Implantaten zur Empfängnisverhütung, Herzschrittmachern,
subkutanen Injektionskanälen (Insulin-Dispenser) oder Piercings.
D
Warn- und Sicherheitshinweise
Getting Acquainted With i-Light