PAGE 4 Introducing the Remington® iLIGHT® Hair Removal System 5 What is the Remington
®
iLIGHT® Hair Removal System Used For? (Indications) 8 Who Should Not Use the Remington® iLIGHT® Hair Removal System? (Contraindications) 9 Warnings 10 Precautions 13 Risks 15 How Does the Remington
®
iLIGHT® Hair Removal System Work? 16 The Remington® iLIGHT® Hair Removal System Reference 18 Getting to Know Your Remington
®
iLIGHT® Hair Removal System 19 What to Expect During and After a Remington® iLIGHT® Hair Removal System Treatment 21 Using the Remington
®
iLIGHT® Hair Removal System for Treatment
34 After Your Remington
®
iLIGHT® Hair Removal System Treatment 38 Replacing the Replacement Cartridge 40 Troubleshooting 47 Contact Information/Specifications/Labeling 48 Customer Service and Warranty 50 Treatment Cards
4 5
The Remington iLIGHT Hair Removal System is an over-the-counter device indicated for the removal of unwanted body hair. The device is also intended for permanent reduction in unwanted hair. Permanent hair reduction is defined as the long-term stable reduc­tion in the number of hairs regrow­ing when measured at 6, 9, and 12 months after the completion of a treat­ment regiment.
Skin Tone
The Remington iLIGHT Hair Removal System is intended for use only on light to medium skin tones. To determine if your skin tone is suitable to use with the device, compare your skin in the intended treatment areas with the Skin Tone Chart. See Figure 1. If it matches the Light to Medium skin tones, you can use the Remington iLIGHT device. If your skin tone in the intended treat­ment area matches the dark skin tones below, DO NOT use the device.
The Remington iLIGHT device also has a built-in SKIN TONE SENSOR that is designed to help prevent flashing on skin that is too dark for treatment. See Step 2 of “Using the Remington iLIGHT Hair Removal System for Treatment” in the TOC for details. Test each different area you wish to treat with the Skin Tone Chart and SKIN TONE TESTER. Some areas are darker than others.
If you have tanned skin in the intended treatment area, DO NOT use the Remington iLIGHT device in those areas as your skin may be too dark for treatment. You should wait until your tan has completely faded from any intended treatment area before using the device.
What is the Remington® iLIGHT® Hair Removal System Used For? (Indications) Introducing the Remington® iLIGHT® Hair Removal System
Congratulations on the purchase of your new Remington iLIGHT Hair Removal System! The Remington iLIGHT Hair Removal System is a new breakthrough product that uses Intense Pulsed Light (“IPL”) to remove unwanted hair at-home. The device utilizes the same clinically proven technology that profes­sional dermatologists and salons use, but optimized for personal treatment of smaller areas in the privacy and comfort of your own home.
Unlike most at-home hair removal methods, the Remington iLIGHT Hair Removal System doesn’t cut or pull out hair; it actually uses light energy to work below the skin’s surface to disable active hairs at the root. You should gradually notice fewer hairs in the treatment area within a few weeks, with results generally improving over time.
The Remington iLIGHT Hair Removal System is intended for use on:
• Male and Female Body Hair (under­arms, bikini line, and on legs, arms, stomach and chest).
Note: The Remington iLIGHT device isn’t for everyone. Please review the Contradictions, Warnings and Precautions to determine if the device is OK for you to use. See Table of Contents (TOC).
6 7
Hair Color
The light energy targets dark coloring in hair, and therefore works best on DARKER HAIR (black, dark brown, brown or dark blond). DO NOT use the Remington iLIGHT device on gray or white hairs or “peach fuzz,” as it will not work. The device is less effective on LIGHT HAIR such as blond or red.
PALE
BEIGE
BEIGE LIGHT
BROWN
MEDIUM
BROWN
DARK
BROWN
BLACK
YES - OK to use NO - DO NOT USE
LIGHT TO MEDIUM SKIN TONES DARK SKIN TONES
What is the Remington® iLIGHT® Hair Removal System Used For? (Indications)
Treatment Areas
The Remington iLIGHT Hair Removal System is intended for use on Male and Female Body hair on under-
arms, bikini line, legs, arms, chest
and stomach. If you have unwanted DARKER HAIR in any of these areas, you will need approximately 10 flashes to cover a 1.5” x 3” treatment area. Treat in a GRID-LIKE PATTERN – slight overlaps are OK, but DO NOT flash the same EXACT spot multiple times during one treatment session. Record treat­ments with the iLIGHT App, available at the iTunes store or on Google Play, or with the TREATMENT CARDS. See TOC.
Note: DO NOT physically mark the treatment area with grid pattern as this could cause injury to the skin.
Graphic not actual size.
Figure 1
8 9
Warnings
The Remington iLIGHT Hair Removal System is a powerful device. As such it should be used with special atten­tion to safety. Please read all warn­ings and safety precautions before use and follow them strictly when using the device.
DO NOT flash in an environment
where the emission of light could cause an explosion, such as in the presence of gas.
KEEP OUT OF REACH OF
CHILDREN! DO NOT leave the Remington iLIGHT device unattended around children as the cords rep­resent a choking hazard. Children should be supervised to ensure that they do not play with the appliance.
The Remington iLIGHT device
SHOULD NOT be used by anyone under the age of 18.
DO NOT use the Remington iLIGHT device if you have a known sensitiv- ity to light (photosensitivity) or are taking medications that make your skin more sensitive to light, as the Remington iLIGHT device may injure your skin or make existing conditions worse.
Who Should Not Use the Remington® iLIGHT® Hair Removal System (Contraindications)
Important Safety Information – Read Before Use!
The Remington iLIGHT Hair Removal System is not designed for everyone. Please read and consider the information in the following section before use.
DO NOT USE the Remington iLIGHT device if you have DARK SKIN. Darker skin may absorb too much light energy which could cause skin swelling, temporary blisters, or could change the color of your skin. Refer to the Skin Tone Chart to determine if your skin tone is suitable for use with the Remington iLIGHT device. See Figure 1. You should test each different area of skin you want to treat. Some areas are darker than others.
DO NOT USE the Remington iLIGHT device on TATTOOS, DARK BROWN or BLACK SPOTS (such as dark freckles, birthmarks, moles, or warts), LIPS,
NIPPLES, GENITALS or AROUND THE ANUS. These areas have darker skin
and may absorb too much light energy which could cause skin swelling, tem­porary blisters, or could change the color of your skin.
DO NOT USE the Remington iLIGHT device ON EYES, EYEBROWS or EYELASHES. Doing so can cause seri­ous and permanent eye injury.
DO NOT USE the Remington iLIGHT device anywhere on the FACE, HEAD
OR NECK.
10 11
DO NOT use the Remington iLIGHT
device if your skin is sensitive to light. In order to determine if you can use the device, perform a test on a small patch of skin and wait 24 hours to determine if there are any adverse reactions before using the device more broadly. See steps for testing on a patch of skin in Table 2. Contact Customer Service for more information or assistance. See page 48.
DO NOT use the Remington iLIGHT
device if you are or may be pregnant or are breast-feeding. The Remington iLIGHT device has not been tested on pregnant women. Hormonal changes are common during pregnancy or breast-feeding and could increase skin sensitivity and the risk of skin injury.
DO NOT flash the Remington iLIGHT
device against any material other than skin.
DO NOT use the Remington iLIGHT
device for any purpose other than hair removal.
DO NOT use the Remington iLIGHT
device on any area where you may someday want your hair to grow back. The results may be permanent and irreversible.
DO NOT cover any part of the
Remington iLIGHT device ventila­tion slots during use, as they help to keep the device cool during operation. Covering the ventilation slots could result in the device overheating.
DO NOT use the Remington iLIGHT
device if the box packaging or the device appears damaged or if any part of the device body is cracked or broken. Doing so could increase the risk of skin or eye injury from the flash lamp. Contact Customer Service for assis­tance. See page 48.
DO NOT allow the Remington iLIGHT
device to become damp or wet.
The Remington iLIGHT Hair Removal System is a powerful device. As such it should be used with special attention to safety. Please read all warnings and safety precautions before use and follow them strictly when using the device.
DO NOT use the Remington iLIGHT device if you have TANNED SKIN in the intended treatment area, as your skin may be too dark and treatment in tanned areas could temporarily cause skin swelling, blisters, or could change the color of your skin. Wait until your tan has faded in the treat­ment area before treating.
DO NOT flash the Remington iLIGHT device on the identical treatment spot multiple times during the same ses­sion, as this could temporarily cause skin swelling, blisters, or could change the color of your skin. See instructions under “Using the Remington iLIGHT Hair Removal System for treatment” in the TOC for more information on how to properly administer treatment.
DO NOT treat any area more than once
every other week, as this will not speed up results, but could increase likelihood of skin swelling, blistering or changing the color of your skin.
DO NOT use the Remington iLIGHT
device on damaged skin, including open wounds, cold sores, sunburns, or areas where you have had a skin peel or other skin resurfacing procedure within the last 6-8 weeks.
DO NOT use the Remington iLIGHT
device on irritated skin, including rashes or swollen skin. These conditions can make the skin more sensitive to the light treatment. Wait for the affected area to heal before using the device.
Precautions
12 13
DO NOT use the device near bathtubs, showers, basins, or other vessels con­taining water. Failure to follow these precautions can cause electrocution or electric shock. Contact Customer Service for assistance. See page 48.
DO NOT operate the Remington iLIGHT device with an unapproved power cord, or if it has a damaged plug or cord. Keep the device cord away from heated surfaces (such as stoves, fireplaces, radiators or furnaces). Failure to follow these precautions can cause electrocution or electric shock. Contact Customer Service for assis­tance. See page 48.
DO NOT open the Remington iLIGHT device (except to replace the removable TREATMENT CAP and/or REPLACEMENT CARTRIDGE) or attempt to repair the device as it contains no user-serviceable parts. Trying to open the device may also damage the device and will void your warranty. Please contact Customer Service if
you have a broken or damaged device. See page 48. Failure to follow these precautions can cause electrocution or electric shock.
• If you’ve had professional, clinical, or self-administered laser, IPL or elec­trolysis hair removal treatments, wait at least 6 months before using the Remington iLIGHT device. If you’ve waxed, plucked or epilated hair in the treatment area, wait at least 6 weeks before using the device. The device uses the hair under your skin to disable your hair at the root, so it is not effective if the hair has been pulled out.
Precautions Risks
It is important to use the Remington iLIGHT Hair Removal System prop­erly. Make sure that you follow all the Warnings, and that you do not use the device if it is not right for you. See TOC. If you do not understand any of the Warnings, or have any questions, please contact Customer Service. See page 48.
If you use the Remington iLIGHT device as directed, the risks are low:
• Your skin may become red within 24
hours after treatment. This redness generally clears up within a few hours. If the redness does not go away within 2-3 days, contact Customer Service. See page 48.
• You may develop temporary blisters, although these are unlikely for people with lighter skin tones. If you do develop a blister, stop using the Remington iLIGHT Hair Removal System, clean the blister and cover it with a bandage and change daily to help prevent the blister from becoming infected. If you need more information, contact Customer Service. See page 48.
• In rare cases, an outbreak of cold sores may develop in the area(s) treated that have a history of cold sores. If the cold sores do not heal after 7 days, contact Customer Service. See page 48.
14 15
How Does the Remington® iLIGHT® Hair Removal System Work?
Light-based hair removal is a well­established technology that has been in use worldwide for over 15 years. The Remington iLIGHT device uses this technology to flash your skin with an intense pulse of light. The energy in the pulse works under the surface of your skin to target hairs at the root, helping to disrupt their growth. Because the energy in the pulse of light targets dark coloring, it works best on darker hair. To avoid targeting (and possibly damaging) dark skin, you should use the device only on light-to­medium skin tones.
How Many Treatments are Needed?
Individual hairs go through a continu­ous growth cycle with phases of active growth and phases of rest. Like other laser or light-based treatments, the Remington iLIGHT device affects only hairs that are in the active growth phase. Your initial regimen should be spread out over 1 month to ensure that you target the most number of active
hairs (including those that recently cycled from the resting phase).
We recommend that you use the device once every two weeks over the span of a month, for a total of 3 treat­ments on each area.
If you have redness, blistering or other skin irritation in the treatment area, DO NOT perform treatment. Wait until the skin returns to normal before using the Remington iLIGHT device again. If the irritation does not go away within 3 days, contact Customer Service. See page 48.
Use the iLIGHT App, or TREATMENT CARDS to help keep track of your treatments. See TOC.
Results aren’t immediate, but you should have noticeably fewer hairs within 1 to 2 weeks after you start treatment. During this time, it may look like the hair is still growing, but it is actually being “pushed out.” You may or may not see these hairs fall out.
Risks
• In rare cases, some users might see an increase in the number of hairs growing. This increase is usually temporary and due to hair growth cycles. However, if after beginning use of the Remington iLIGHT device you believe that the number of hairs regrowing in the treated area has increased since you started treat­ment, stop using the device and contact Customer Service. See page 48.
• Skin swelling, especially around the hair follicle where you may notice the skin is slightly higher than surrounding areas. If the swelling doesn’t go away within 2-3 days, stop using the Remington iLIGHT Hair Removal System and contact Customer Service. See page 48.
• Skin discoloration. If you notice that your skin tone in the treatment area has changed, stop using the device and contact Customer Service. See page 48.
• Eye Injury. Flashing any laser or IPL device near or around the eyes could cause serious and permanent eye injury. This is very unlikely so long as the device is used below the neck as indicated.
16 17
A.
R.
N.
N.
D.
D.
O.
P.
M.
M.
K.
Q.
J.
I.
H.
G.
F.
E.
D.
C.
L.
L.
B.
Figure 2
The Remington® iLIGHT® Hair Removal System Reference
A. Power Switch B. Power Inlet C. Base Unit D. Hand Piece E. Flash Button F. Energy Level Selection Button G. Cool Down Mode Indicator H. Cartridge Status Indicator Display I. Energy Level Selection Display
J. Skin Tone Sensor K. Hand Piece Cord L. Flash Window M. Skin Contact Sensors N. Treatment Cap Release Buttons O. Replacement Cartridge P. Treatment Cap Q. Power Cord R. Lint Free Cloth
18 19
What to Expect During and After a Remington® iLIGHT® Hair Removal System Treatment
During Treatment
For many people, using the Remington iLIGHT Hair Removal System is their first experience with a light-based device. Here are some things to expect during treatment:
• A Flash of Light: The flash of light that you see is only part of the light pro­duced by the device. The Remington iLIGHT Contact Sensors help ensure that most of the light is directed into the skin. The remaining visible light should not be harmful to the eyes, and special eye protection is not needed as long as you follow the directions for using the device in this manual. The Remington iLIGHT device should NOT be used on the eyes, eyelashes or eyebrows.
• A Sensation of Warmth and Tingling: It is normal to feel a warm and tin­gling sensation with each flash. Many people describe this sensation to be like a rubber band lightly snapped against the skin. However, sensations vary by person and treatment area. If the sensation is too intense or pain­ful, stop using the device and contact Customer Service before using again. See page 48.
Inside your Remington iLIGHT device box, you will find the BASE UNIT, POWER CORD, CLEANING CLOTH, and this USER’S MANUAL. The device comes with the TREATMENT CAP and a REPLACEMENT CARTRIDGE pre-assem­bled to the HAND PIECE.
Getting to Know Your Remington® iLIGHT®Hair Removal System
Model
Flashes per LIGHT CARTRIDGE
iLIGHT
®
Pro 1,500*
iLIGHT
®
Pro Plus Quartz 30,000
*Additional LIGHT CARTRIDGES may be included.
On the BASE UNIT, the control panel includes a SKIN TONE SENSOR to test for appropriate Skin Tone before usage, and allows you to control the energy level that’s effective and comfortable for you. See instructions in Figure 3. The POWER SWITCH is located next to the POWER SOCKET.
20 21
Once you’ve become familiar with the Remington iLIGHT device and read all the information on the preceding pages, including the Warnings and Precautions, you’re ready to use the device.
This section explains step-by-step how to operate the device. Read this entire section carefully before you start treat­ment. Then refer back to it later as you follow the steps.
The first time you use the device, you should test it on a small patch of skin. See Table 2.
In addition, we recommend that you use the device in a cooler area where the temperature is less than 80° F (27° C) to help prevent the device from overheating
STEP 1: PREPARE SKIN
Before using the Remington iLIGHT device, prepare the treatment area by thoroughly Cleaning, Shaving, and Drying the intended treatment area. It is important that you remove any makeup from the treatment area.
Removing surface hair and cleaning the skin helps to minimize the sensation felt from the device flashes and allows the energy to penetrate to the hair root. Because the device works below the skin, the device is still effective even if hairs are not clearly visible.
What to Expect During and After a Remington® iLIGHT® Hair Removal System Treatment
Immediately After the First Treatment
• Visible changes to the hair are unlikely at this point. During and just after your Remington iLIGHT device session, it is not uncommon to see some very mild redness, mostly around the hairs themselves. This is normal and typically clears up within a few hours. If the red­ness does not go away within 3 days, contact Customer Service. See page 48.
• If you have redness, blistering or other skin irritation in the treatment area, DO NOT perform treatment. Wait until the skin returns to normal before using the device again. If the irritation does not go away with 3 days, contact Customer Service. See page 48.
One to Two Weeks after the First Treatment
• Hairs in the treated area will begin to fall out gradually, but it is unlikely you will notice significant reduction in hair at this stage.
• Make sure to complete the full treat­ment schedule to ensure you hit all hairs in the growth phase in the tar­geted area.
Two Weeks after the Last Treatment
• You should see a noticeable reduction in hairs in the treated area. Also, any new hair growth should be lighter and finer.
• At this point, additional treatments on the same area should only be done as needed to target hairs that have recently entered the active cycle. You only need to use the Remington iLIGHT device for occasional touch-ups, where necessary, or to treat another area.
Using the Remington® iLIGHT® Hair Removal System for Treatment
22 23
2b. Always place the SKIN TONE SENSOR
window directly on the area of skin you plan to treat. The reading will take place automatically.
Note: You must use the SKIN TONE SENSOR to test color on each body part you plan to treat.
2a. Turn the POWER SWITCH on. The
SKIN TONE SENSOR will flash YELLOW. You will hear a series of audible “BEEPS” every 5 seconds to remind you to take the test. For safety reasons, after 30 seconds of inactivity, the audible “BEEPS” will increase in frequency until the test is taken or the machine is turned off.
SKIN TONE SENSOR LED will be blinking
STEP 2: TURN ON AND UNLOCK the Remington iLIGHT Hair Removal System.
Flip the POWER SWITCH on near the
power inlet. Each time you turn the Remington
iLIGHT device on, you will be prompted to test your skin tone with the SKIN TONE SENSOR. The device will play a melody to remind you to test. See Figure 3.
Note: Using the Remington iLIGHT device on darker skin tones can result in damage to the skin (such as burns, blisters or skin discoloration). To help protect against such damage, the device requires that you test your skin tone before every use. Since some skin areas are darker than others, test each differ­ent area you want to treat.
DO NOT use the Remington iLIGHT device on tanned skin. Even if your natural skin tone is light, tanning makes it darker—potentially too dark for treat­ment. With tanned skin, wait until the tan has completely faded before using the device on that area.
Always use the SKIN TONE SENSOR to determine if your skin is too dark to treat with the Remington iLIGHT device by placing the SKIN TONE SENSOR on the area to be treated. Make sure your skin in this area is clean and dry, and shave it if necessary to be sure it is free of hair.
Figure 3
Using the Remington® iLIGHT ®Hair Removal System for Treatment
24 25
Notes:
• Some areas of skin are darker than others. You must use the SKIN TONE SENSOR on each different area you want to treat.
• If you believe your skin is suitable based on the Skin Tone Chart in Figure 1, but the SKIN TONE SENSOR will not enable the device, contact Customer Service. See page 48.
• If you have tanned skin in the intended treatment area, DO NOT use the Remington iLIGHT device in those areas as your skin may be too dark for treatment. You should wait until your tan has completely faded from any intended treatment area before using the device.
2c. Place the body part to be treated
over the SKIN TONE SENSOR (touching the unit) the sensor will immediately read the skin type.
2d.
If your skin tone is NOT suitable for use, the SKIN TONE SENSOR turns solid YELLOW and the device will “BUZZ” once for 5 seconds. After 5 seconds, you may re-try the SKIN TONE SENSOR (step 2c).
2f. Once the device is enabled, the
ENERGY LEVEL LIGHT and BULB LIFE LIGHT will turn on and the internal fan will start. Your Remington iLIGHT device is set to the lowest energy level setting and ready for use!
Using the Remington® iLIGHT® Hair Removal System for Treatment
STEP 3: SELECT ENERGY LEVEL
ENERGY LEVEL SELECTION DISPLAY illuminates the energy level that the Remington iLIGHT device will deliver to your skin, from the lowest level (
) to the highest level ( ). Higher levels improve hair removal results, but may be less comfort­able. To get the best results, you should use the highest setting that’s comfortable.
There are 5 energy level settings on the device. Whenever the device is turned on, it is automatically set to the lowest energy level and the light will be illumi­nated on the ENERGY LEVEL SELECTION DISPLAY. See Table 1. To modify the energy level, press the ENERGY LEVEL SELECTION BUTTON to increase the energy level. Once the energy level has reached level 5, pressing the ENERGY LEVEL SELECTION BUTTON will return the device to energy level 1. The num­ber of lights on the ENERGY LEVEL SELECTION DISPLAY will coincide with the change in energy level. See Table 1.
2e. If your skin tone is suitable for
use, a high-pitched “BEEP” will sound and the SKIN TONE SENSOR will turn green and the device is ready for use.
26 27
Using the Remington® iLIGHT® Hair Removal System for Treatment
3c. If a higher energy level was
previously selected and a lower energy level is desired, continue to press the ENERGY LEVEL SELECTION BUTTON until the desired lower energy setting is set. After reaching Level 5, pressing the ENERGY LEVEL SELECTION BUTTON an additional
time will reset to Energy Level 1. As with any new skin care product, we recommend testing the device on a patch of skin before your first full treatment or before treating a new area.
Energy Level 1 2 3 4 5 Press ENERGY LEVEL SELECTION BUTTON
Defaults to Level 1 upon start-up.
ENERGY LEVEL SELECTION DISPLAY lights:
3a. Upon start-up, the device sets itself
to the lowest energy level (Level 1 above).
The device is now ready to trigger the first flash. (See “Using the Remington iLIGHT Hair Removal System for Treatment").
3b. To change the energy level press
the ENERGY LEVEL SELECTION BUTTON to increase the energy level until the desired energy level is set (for example, pressing the ENERGY LEVEL SELECTION BUTTON once will increase from Level 1 to Level 2; pressing another time will increase to Level 3). ENERGY LEVEL SECTION DISPLAY will coincide with the energy level setting.
Table 1
STEP 4: SKIN PATCH TEST
Before treating an area for each time, test a patch of skin to determine the appropriate energy level. Mild to moderate discomfort that is tolerable is normal. If the discomfort is intolerable, or you develop side effects, STOP.
Use the table below to find the energy level that is right for you.
Table 2
ENERGY
LEVEL
SELECTION
DISPLAY
Flash skin/
Wait 15
Minutes
Tolerable/No Side Effects
YES NO
Once Increase Energy Level STOP
Do not use this device
Once Increase Energy Level STOP
Use Energy 1 for treatment
Once Increase Energy Level STOP
Use Energy 2 for treatment
Once Increase Energy Level STOP
Use Energy 3 for treatment
Once Use Energy Level 5 for
treatment
STOP
Use Energy 4 for treatment
Note: Higher energy levels may be more effective, but may not be tolerable or may cause side effects.*
28 29
Using the Remington® iLIGHT® Hair Removal System for Treatment
STEP 5: TREAT YOUR SKIN
The Remington iLIGHT device can flash approximately every 3 seconds and is ideal for treating both larger and smaller areas.
Periodically, if either the hand piece or base unit gets too hot, the “Hourglass” icon will flash and the unit will beep. Wait for a few minutes to allow the device to cool down. There is no need to shut the unit down, as the hourglass and beeps will turn off when the device is ready to use again. The number of flashes delivered before the cool down state depends on several factors, including how fast you apply the treatments, and the room temperature. See Figure 4.
DO NOT FLASH A PATCH OF SKIN MORE THAN ONCE; YOU WILL NOT GET AN ACCURATE RESULT AND MAY CAUSE SIDE EFFECTS.
* Side effects include blistering, burns, and changes in skin tone. Wait 15 minutes to see if acute side effects develop. If you are unsure about your skin’s reaction to a particular energy level, do not treat with that energy level. Wait 24 hours before treating to be sure you have selected the appro­priate energy level.
5a. Ensure that the energy level is on
the correct setting. See Table 2 for details about the different settings.
5b. Apply the TREATMENT CAP to
the skin, making sure the skin is spread evenly and smoothly. Make sure the SKIN CONTACT SENSORS on the TREATMENT CAP are in full contact with the skin.
SKIN CONTACT SENSORS
Figure 4
30 31
5c. If the SKIN CONTACT SENSORS are
NOT in full contact with the skin, the device will not operate if you press the FLASH BUTTON and it will “BUZZ.” Double check that the SKIN CONTACT SENSORS are in full contact with the skin.
5d. If the SKIN CONTACT SENSORS
on the TREATMENT CAP are in full contact with the skin, a series of high-pitched “BEEPS” will sound indicating the device is OK to flash.
5e. Press the FLASH BUTTON. The
device will flash a pulse of light onto your skin. You will see a flash of light and simultaneously hear a sound, which is normal for the device. You may feel a mild sen­sation of warmth and tingling.
5f. Immediately after a flash is deliv-
ered, move the HAND PIECE to a new treatment location while keeping the FLASH BUTTON pressed down. After 3 seconds the CARTRIDGE STATUS INDICATOR DISPLAY will turn on again and the device will beep. If the TREATMENT CAP is in full con­tact with the skin and the FLASH BUTTON is pressed down, another flash will be delivered.
After a flash is delivered, lift the HAND PIECE to the next area in a grid-format.
Note: If the button is kept depressed, the HAND PIECE can be slid between spots.
Three seconds later, (assuming SKIN CONTACT SENSORS are in contact with skin), the device will once again emit a “BEEP” to confirm that it is ready to flash.
The device will operate if FLASH BUTTON is pressed.
Using the Remington® iLIGHT® Hair Removal System for Treatment
5g. Try to treat in an organized, grid-
like pattern to ensure you cover all hairs in the intended treatment area. WARNING: DO NOT flash the Remington iLIGHT device on the same treatment spot multiple times during the same session, as this could cause skin swell­ing, temporary blisters, or could change the color of your skin.
32 33
Repeat step 5 until the desired treat­ment area is fully covered. Depending on the area, the treatment time will vary.
Note: For faster coverage you may hold down the FLASH BUTTON while you lift the HAND PIECE and place it back in contact with a new area to be treated. This will cause the unit to deliver a flash to the skin as soon as full contact between the skin and the treatment cap is established.
Recommended Treatment Schedule
Your initial regimen should be spread out over 1 month to ensure that you target the most number of active hairs (including those that recently cycled from the resting phase).
We recommend that you use the Remington iLIGHT device once every two weeks over the span of a month, for a total of 3 treatments on each area.
If you have redness, blistering or other skin irritation in the treatment area, DO NOT perform the treatment. Wait until the skin returns to normal before using the device again. If the irritation does not go away within 3 days, contact Customer Service. See page 48.
OTHER TREATMENT TIPS
• Perform your treatments at night before going to bed, so that any lingering redness will most likely disappear by the morning.
• If you’ve waxed hair in the treatment area, wait 6 weeks before using the Remington iLIGHT device. The device uses the hair under your skin to disable your hair at the root, so it is not effective if the hair has been pulled out.
• Shave immediately before treating the area. This will allow you to use a higher energy level as there’s no sur­face hair to absorb the light energy. How well you shave will make a big difference in how the treatment feels. See Step 1 under “Using the Remington iLIGHT Hair Removal System for Treatment” in the TOC.
• Periodically, if the device gets too hot, the “Hourglass” icon will flash and the unit will beep. Wait for a few minutes to allow the device to cool down. There is no need to shut the unit down, as the hourglass icon will disappear when your Remington iLIGHT device is ready to use again.
• The number of flashes delivered before the cool down state depends on several factors, including how fast you apply the treatments and the room temperature.
• Use the highest energy level setting that’s comfortable for you and that does not cause an adverse reac­tion. Higher energy levels are more effective. See Step 3 under “Using the Remington iLIGHT Hair Removal System for Treatment” in the TOC.
Using the Remington® iLIGHT® Hair Removal System for Treatment