remeha Avanta Plus Combi 24C, Avanta Plus Combi 28C, Avanta Plus Combi 35C, Avanta Plus Combi 39C, Avanta Plus System 18S User guide

...
120578-160109
058
Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales).
This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service.
The Benchmark Checklist may be required in the event of any warranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information Pack.
User Guide
Remeha Avanta Range
24c | 28c | 35c | 39c | 18s | 24s | 30s
© Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions furnished by us remain our property and may not be multiplied without our prior consent in writing.
Broag Ltd. Remeha House Molly Millars Lane RG41 2QP WOKINGHAM, Berks.
Tel: +44 118 9783434 Fax: +44 118 9786977 Internet: uk.remeha.com
www.avantarange.com
E-mail: boilers@broag-remeha.com
Remeha Avanta Plus
230 V
Gas
2bar
Min. 1 bar
230 V
R
R
R
R
R
R
R
R
R
R
24c / 28c / 35c / 39c / 18s / 24s / 30s
5 ENABLING THE BOILER
LT.AL.W7H.000.224
LT.AL.W7H.000.228
2. Disable boiler without frost protection, during longer periods of non-use
• Switch off the boiler.
• Turn off the boiler gas tap.
Drain boiler
Drain the boiler and central heating system if you will not be using the home for a long period and there is a chance of night frost.
SHORT USER GUIDE
1 SAFETY
Can you smell gas? What to do:
• Do not smoke and do not create any flame or sparks.
• Do not use any electric switches.
• Turn off the main gas stop cock.
• Open windows and doors.
• Warn those present and leave the building together.
• Call your gas suppliers / installer once you are outside the building, TRANSCO tel. 0800 111 999.
Can you smell smoke or flue gases? What to do:
• Switch off the boiler.
• Open windows and doors.
• Warn those present and leave the building together.
• Call your installer once you are outside the building.
Installation location for the boiler!
• Do not store or use any flammable materials, aggressive substance and/or aerosols near the boiler.
• The installation area must be frost-free.
• The switched spur unit for the boiler must always be accessible.
Water and pipe temperatures!
• The factory setting for the tap water temperature is 55°C; this temperature can be set to 65°C.
• The maximum water temperature in the Avanta Plus can reach 90°C. This means that pipes and/or radiators can reach this temperature.
• If the boiler is running, the flue duct can reach a high temperature.
2 PROBLEMS WITH BOILER AND/OR CENTRAL HEATING SYSTEM
Error codes – errors which can be resolved by the user
• Check the boiler water pressure. If the water pressure
is less than 1 bar, the system has to be topped up with water.
LT.AL.W7H.000.054
é1 / é2
Check water pressure: water pressure is greater or
equal to 1 bar.
Press R-key
Wait for recovery; display shows
0,
boiler functions properly.
Display shows , ,  or  again; note down the error code
and boiler type and call your installer
• Switch on the boiler at the fused spur unit; the boiler will
run the start-up program.
é7 / é10
Or
- A display test will briefly appear showing all segments of the
LT.AL.W7H.000.225
display.
f[ xx software version; p[ xx parameter version;
- A venting cycle of 3 minutes now follows, the version num-
bers will be displayed alternately;
Check water pressure: water pressure is lower than
1 bar.
Top up your central heating
system
Press R-keyOrWait for recovery;
display shows
0, boiler
functions properly.
Display shows , ,  or  again; note down the error code
and boiler type and call your installer
- Next, the following will appear in the display;
[1 pre-purge stage [2 ignition stage
LT.AL.W7H.000.212
[3 operating in CH mode or: [4 operating in DHW mode [7 pump run on after CH or DHW is satisfied [0 stand-by mode
• Set the room thermostat to the desired room temperature.
The boiler will now automatically start operating.
é4
Check yellow gas valve, bottom boiler, gas valve must be in line with gas supply pipe, if necessary open gas valve.
Press R-key Wait for
recovery; display shows
0, boiler
functions properly.
LT.NL.W6H.000.079
4
Error codes – errors which have to be remedied by the installer
If the display indicates a different error code from that described above, note down the error code and boiler type and call your installer. Contact your installer also in the event of a water leak.
Or
Display shows E4 again: note down the error code and boiler type and call your installer.
LT.NL.W6H.000.114 + LT.NL.W6H.000.115 + LT.NL.W6H.000.116 + LT.AL.W7H.000.235 + LT.NL.W6H.000.118
LT.AL.W7H.000.230 + LT.NL.W6H.000.121 + LT.NL.W6H.000.122
1
Remeha Avanta Plus
R
1x
R
2x
R
3x
5x
R
R
R
24c / 28c / 35c / 39c / 18s / 24s / 30s
3 CHANGING BOILER SETTINGS
LT.NL.W6H.000.070
LT.NL.W6H.000.071
1. Changing P1 setting: flow temperature of water in central heating system
Reduce the flow temperature as follows:
• Press ‘Enter’- key until codes p [ and [ 1 are displayed alternately.
• Press ‘Enter’- key again; set value for maximum flow temperature is displayed: 75°C (factory setting).
• Press [+] or [-] -key to change this value, for example to 70°C.
• Press ‘Enter’- key to confirm value; codes p [ and [ 1 are displayed alternately.
• Press ‘Reset’- key to switch boiler to operating mode.
2. Changing P2 setting: domestic hot water temperature
Increase the domestic hot water temperature as follows:
• Press ‘Enter’- key until codes p [ and [ 1 are displayed alternately.
• Press ‘[+]- key until codes p [ and [ 2 are displayed alternately.
• Press ‘Enter’- key; set value for domestic hot water temperature is displayed: 55°C (= factory setting).
• Press [+] or [-]- key to change this value, for example to 65°C.
• Press ‘Enter’- key to confirm value; codes p [ and [ 2 are displayed alternately.
• Press ‘Reset’- key to switch boiler to operating mode.
LT.NL.W6H.000.073
4. Changing P4 setting: Eco or comfort mode
No hot water
Beware; the system boiler in combination with an external calorifier will not warm up the calorifier in the Eco-mode. So, if the calorifier is empty, the tap water will be cold.
0 = Comfort mode
1 = Eco mode
2 = regulated by controller (= factory setting)
Change the mode as follows:
• Press ‘Enter’- key until codes p [ and [ 1 are displayed alternately.
• Press [+]- key 3x until codes p [ and [ 4 are displayed alternately.
• Press ‘Enter’- key; setting of ‘eco or heat retention’ mode is displayed (mode 2 = heat retention and regulator-dependent, factory setting).
• Press [-]- key to change this mode, for example mode 1 (=eco mode).
• Press ‘Enter’- key to confirm this mode; codes p [ and [ 4 are displayed alternately.
• Press ‘Reset’- key to switch boiler to operating mode.
P6 setting: display on/off
Change the display setting as follows:
• Press ‘Enter’- key until codes p [ and [ 1 are displayed alternately.
• Press [+]- key 5x until codes p [ and [ 6 are displayed alternately.
• Press ‘Enter’- key; you will see mode 2( = ‘Display automatically off’, factory setting).
• Press [-]- key to change this mode to mode 1 (= ‘Display remains on’).
• Press ‘Enter’- key to confirm this mode; codes p [ and [ 6 are displayed alternately.
• Press ‘Reset’- key to switch boiler to operating mode.
3. Changing P3 setting: boiler regulation (domestic hot water and central heating mode)
0 = CH 1 = CH 2 = CH 3 = CH
/ DHW
off
/ DHW on (factory setting)
on
/ DHW
on
/ DHW
off
off
off
on
LT.NL.W6H.000.075
4 DISABLING THE BOILER
The boiler must be disabled before any maintenance or repairs are carried out. If the
Change the boiler regulation as follows:
• Press ‘Enter’- key until codes p [ and [ 1 are displayed alternately.
central heating system is not used for a long time (during the holidays, for instance, or periods of milder weather) it is advisable to disable the boiler.
• Press [+]- key 2x until codes p [ and [ 3 are displayed alternately.
• Press ‘Enter’-key: central heating and domestic hot water mode setting is displayed.
• Press [-] or [+]- key to change this mode, e.g. level 3 (= central heating OFF
LT.NL.W6H.000.072
and domestic hot water ON).
• Press ‘Enter’- key to confirm this mode; codes p [ and [ 3 are displayed alternately.
1. Disable boiler with frost protection, during longer periods of non-use
• Set the room thermostat to a low temperature, e.g. 10°C,
• Switch setting p4 to 1 (Eco mode), this will switch off the heat retention function. Now the boiler will only start working to protect itself against freezing. With an external frost protection connected, the boiler can also prevent the central heating system from freezing.
• Press ‘Reset’- key to switch boiler to operating mode.
Broag Remeha is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk
LT.AL.W7H.000.217 + LT.AL.W7H.000.218
Pre and After Sales Service
Our dedicated pre-and-after-sales teams are ready te give you the support you need. It’s an integral part of the quality package that Broag offers as standard with all products.
For all your queries just call the Avanta team on: 0118 978 3434
Contact Information
Sales: 0118 9743060 After Sales: 0118 9743070 Literature: 0118 9743043 Training: 0118 9743020 Technical: 0118 9743070 Spares: 0118 9743070
www.avantarange.com
3