Please ensure that the installer has fully completed the Benchmark Checklist on the inside
back pages of the installation instructions supplied with the product and that you have signed
it to say that you have received a full and clear explanation of its operation. The installer is
legally required to complete a commissioning checklist as a means of complying with the
appropriate Building Regulations (England and Wales).
All installations must be notified to Local Area Building Control either directly or through
a Competent Persons Scheme. A Building Regulations Compliance Certificate will then
be issued to the customer who should, on receipt, write the Notification Number on the
Benchmark Checklist.
This product should be serviced regularly to optimise its safety, efficiency and performance.
The service engineer should complete the relevant Service Record on the Benchmark
Checklist after each service.
The Benchmark Checklist may be required in the event of any warranty work and as
supporting documentation relating to home improvements in the optional documents section
of the Home Information Pack.
User Guide
Remeha Avanta Range
24c | 28c | 35c | 39c | 18s | 24s | 30s
© Copyright
All technical and technological information contained in these
technical instructions, as well as any drawings and technical
descriptions furnished by us remain our property and may not be
multiplied without our prior consent in writing.
Broag Ltd.
Remeha House
Molly Millars Lane
RG41 2QP WOKINGHAM,
Berks.
Tel: +44 118 9783434
Fax: +44 118 9786977
Internet: uk.remeha.com
www.avantarange.com
E-mail: boilers@broag-remeha.com

Remeha Avanta Plus
24c / 28c / 35c / 39c / 18s / 24s / 30s
5 ENABLING THE BOILER
LT.AL.W7H.000.224
LT.AL.W7H.000.228
2. Disable boiler without frost protection, during longer
periods of non-use
• Switch off the boiler.
• Turn off the boiler gas tap.
Drain boiler
Drain the boiler and central heating system if you will not be
using the home for a long period and there is a chance of
night frost.
SHORT USER GUIDE
1 SAFETY
Can you smell gas? What to do:
• Do not smoke and do not create any flame or sparks.
• Do not use any electric switches.
• Turn off the main gas stop cock.
• Open windows and doors.
• Warn those present and leave the building together.
• Call your gas suppliers / installer once you are outside the
building, TRANSCO tel. 0800 111 999.
Can you smell smoke or flue gases? What to do:
• Switch off the boiler.
• Open windows and doors.
• Warn those present and leave the building together.
• Call your installer once you are outside the building.
Installation location for the boiler!
• Do not store or use any flammable materials,
aggressive substance and/or aerosols near the boiler.
• The installation area must be frost-free.
• The switched spur unit for the boiler must always be
accessible.
Water and pipe temperatures!
• The factory setting for the tap water temperature is 55°C;
this temperature can be set to 65°C.
• The maximum water temperature in the Avanta Plus can
reach 90°C. This means that pipes and/or radiators can
reach this temperature.
• If the boiler is running, the flue duct can reach a high
temperature.
2 PROBLEMS WITH BOILER AND/OR CENTRAL HEATING SYSTEM
Error codes – errors which can be resolved by the user
• Check the boiler water pressure. If the water pressure
is less than 1 bar, the system has to be topped up with
water.
LT.AL.W7H.000.054
é1 / é2
Check water
pressure:
water pressure
is greater or
equal to 1 bar.
Press R-key
Wait for
recovery;
display shows
0,
boiler functions
properly.
Display shows , , or
again; note down the error code
and boiler type and call your installer
• Switch on the boiler at the fused spur unit; the boiler will
run the start-up program.
é7 / é10
Or
- A display test will briefly appear showing all segments of the
LT.AL.W7H.000.225
display.
f[ xx software version;
p[ xx parameter version;
- A venting cycle of 3 minutes now follows, the version num-
bers will be displayed alternately;
Check water
pressure:
water pressure
is lower than
1 bar.
Top up your
central heating
system
Press R-keyOrWait for recovery;
display shows
0, boiler
functions
properly.
Display shows , , or
again; note down the error code
and boiler type and call your installer
- Next, the following will appear in the display;
[1 pre-purge stage
[2 ignition stage
LT.AL.W7H.000.212
[3 operating in CH mode or:
[4 operating in DHW mode
[7 pump run on after CH or DHW is satisfied
[0 stand-by mode
• Set the room thermostat to the desired room temperature.
The boiler will now automatically start operating.
é4
Check yellow
gas valve,
bottom boiler,
gas valve must
be in line with
gas supply pipe,
if necessary
open gas valve.
Press R-key Wait for
recovery;
display shows
0, boiler
functions
properly.
LT.NL.W6H.000.079
4
Error codes – errors which have to be remedied by the installer
If the display indicates a different error code from that described above, note down the error code and boiler type and call your
installer. Contact your installer also in the event of a water leak.
Or
Display shows
E4 again:
note down the
error code and
boiler type
and call your
installer.