Gas Inserts
L234 Gas Insert
Model L234-NG L234-LP
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (2.99 kPa)
Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orifi ce Size -Altitude 0-4500 ft. #42 DMS #54 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
Flex Vent Systems: FPI AstroCap™ Flex Vent
Approved Venting Systems
12,500 BTU/h
(3.66 kW)
23,500 BTU/h
(6.89 kW)
3”x3” Co-linear
2”x3” Co-linear (Optional)
(Standard)
11,000 BTU/h
(3.22 kW)
21,500 BTU/h
(6.30 kW)
3”x3” Co-linear (Standard)
2”x3” Co-linear (Optional)
L234 Gas Insert
Gas Inserts
B
1
A
1
A
2
B
2
CC
Contemporary Faceplate
D
H
F
60°
G
Contour Faceplate
I
E
Dimension Description L234
A1 Contour Faceplate Width 27-1/2” (699mm)
B1 Contour Faceplate Height 20-3/4” (527mm)
A2 Contemporary Faceplate Width 27-3/4” (705mm)
2 Contemporary Faceplate Height 21” (533mm)
B
C Unit Width 19-1/2” (495mm)
D Unit Height 16-7/8” (429mm)
E Unit Depth 13” (330mm)
F Faceplate to Vent Centerline 11-3/4” (299mm)
G Contour Faceplate Depth 2-1/2” (64mm)
G Contemporary Faceplate Depth 3” (76mm)
H Height to Vent Collar 16-1/4” (413mm)
I
Air Intake Collar (Standard) 3” (76mm)
Air Intake Collar (Optional) 2” (51mm)
Minimum Fireplace Dimensions
The minimum fi replace dimensions for the FPI gas fi replace insert are
shown in the following diagrams:
M
J
Dimension Description
J Height 17” (432mm) 17” (432mm)
K Width 25” (635mm) 25” (635mm)
L Depth 14” (356mm) 14” (356mm)
N Rear Width 16” (406mm) 16” (406mm)
L
aaaaaaaa
aaaaaaaa
K
aaaaaaaa
aaaaaaaa
aaaaaaaa
N
Contour
Faceplate
Contemporary
Faceplate
123June 2007 Regency Product Specifi cations Book
L234 Gas Insert
Clearances
Gas Inserts
Combustible Mantels
Unless otherwise stated the clearances listed below are Minimum
distances to combustible materials. Please Note: A major cause
of chimney related fi res is due to a failure to maintain required
clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in
accordance with these instructions.
Clearances to Combustibles
Dimension Description L234
A From Unit to Side Walls 8” (203mm)
B From Unit to Ceiling 56” (1422mm)
Gas Inserts
C Minimum Mantel Height 21” (533mm)
D Maximum Mantel Depth 12” (305mm)
E Alcove Width 60” (1524mm)
F Alcove Depth 36” (914mm)
G Hearth Height 1-1/2” (38mm)
H Hearth Width 28” (711mm)
I Hearth Depth 12” (305mm)
Dimensions are measured from the edge of the door frame.
Because of the extreme heat this fi replace emits, the mantel
clearances are critical. Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.
Mantel
Faceplate
Hearth
G
Hearth Clearances Flush and Raised
12" Max.
D
To p o f
Door Frame
Existing or
Non-Combustible Hearth
12” Min.
C
Mantel
Faceplate
4” min
No Hearth required when unit is raised 4”
12" Max.
D
To p o f
Door Frame
C
Combustible
Flooring
Flush Front Mantel Clearances
Note: A non-combustible mantel may be installed at a lower
height.
Note: Ensure the paint that is used on the mantel and the facing
is “heat resistant” or the paint may discolour.
124 June 2007 Regency Product Specifi cations Book