Regency I3100L, I1100S User Manual

www.regency-fi re.com
WOOD
Fireplace
Inserts &
Hearth Heater
Tested by:
908-332b
MODELS: H2100 I1100S I3100L
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
11/15/07
Thank-you for purchasing a
REGENCY FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
Keep those REGENCY FIRES burning.
SAFETY NOTE: If this Insert is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building or fi re offi cials about restrictions and instal­lation inspection requirements in your area.
Regency Wood Insert & Hearth Heater2
TABLE OF CONTENTS
REGENCY FIREPLACE INSERTS
& HEARTH HEATER
SAFETY LABEL
Safety Label For I1100S & I3100L ................................. 4
Safety Label For H2100M .............................................5
INSTALLATION
Before Installing Your Insert ..........................................6
Chimney Specifi cations .................................................6
Fireplace Specifi cations ................................................6
Installing Your Insert ......................................................6
Optional Flue Connector Kit ..........................................7
Masonry and Factory Built Fireplace Clearances .........7
Leg Option on H2100 Hearth Heater .............................8
Flue Connector Bracket .................................................8
Installation Into a Factory Built Fireplace ......................8
Installation Into a Masonry Fireplace .............................8
Faceplate and Trim .......................................................9
Fan / Blower ................................................................10
Floor Protection ........................................................... 11
Firebrick Assembly ...................................................... 11
Door Handle ................................................................11
Brick Flue Baffl e & Secondary Air Tube Installation ....11
Draft Control ................................................................12
Screen Door ................................................................12
OPERATING INSTRUCTIONS
First Fire ......................................................................13
Fan Operation (All Units) .............................................13
Ash Disposal ...............................................................13
Some Safety Guidelines ..............................................13
Creosote ......................................................................14
MAINTENANCE
Maintenance of Gold-Plated Doors .............................14
Door Gasket ................................................................14
Door Latch Adjustment ................................................14
Glass Cleaning ............................................................14
Glass Replacement .....................................................14
Glass Removal ............................................................14
PARTS LIST
I1100 & I3100 Main Assembly .....................................15
I1100 & I3100 Faceplates ............................................16
H2100 Main Assembly .................................................17
I1100, I3100 & H2100 Firebrick ...................................18
WARRANTY
Warranty ......................................................................19
Regency Wood Insert & Hearth Heater 3
SAFETY LABEL
HOT
WHILE
IN
OPERATION
DO
NOT
TOUCH.
KEEP
CHILDREN,
CLOTHING
AND
FURNITURE
AWAY.
CONTACT
MAY
CAUSE
SKIN
BURNS.
READ
ABOVE
NSTRUCTIONS.
This is a copy of the label that accompanies each
Regency Small Flush Insert and Large Flush Insert. We have printed a copy of the contents
here for your review.
SAFETY LABEL FOR I1100S AND I3100L
(Duplicate Serial #)
AWAY.
CHILDREN,
OPERATION
KEEP
IN
FURNITURE
CAUTION
DO NOT REMOVE THIS LABEL
104
AND
WHILE
TOUCH.
HOT
NOT
DO
CLOTHING
MANUFACTURED BY:
FPI FIREPLACE PRODUCTS
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
104
BURNS.
SKIN
INSTRUCTIONS.
CAUSE
MAY
ABOVE
READ
CONTACT
UNITED STATES ENVIRONMENTAL PROTECTION
AGENCY CERTIFIED TO COMPLY WITH JULY 1990,
PARTICULATE EMISSION STANDARDS.
908-306b 10/03
6988 VENTURE ST.
INTERNATIONAL LTD.
DELTA, BC V4G 1H4
DO NOT REMOVE THIS LABEL
CAUTION
106
UNITED STATES
INSTRUCTIONS.
CHILDREN, CLOTHING
CONTACT MAY CAUSE
DO NOT TOUCH. KEEP
AND FURNITURE AWAY.
HOT WHILE IN OPERATION
SKIN BURNS. READ ABOVE
Manufactured by:
6988 Venture Street
Delta, BC V4G 1H4
INTERNATIONAL LTD.
FPI FIREPLACE PRODUCTS
EMISSION STANDARDS.
WITH JULY 1990, PARTICULATE
AGENCY CERTIFIED TO COMPLY
ENVIRONMENTAL PROTECTION
MADE IN CANADA
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5IN / 38MM
ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST
BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING
(E) 16 IN / 405MM TO FRONT AND (G) 8IN / 205MM TO SIDES FROM FUEL
DOOR.
D
G
C
E
B
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY)
LISTED FACTORY BUILT FIREPLACE INSERT
CERTIFIED FOR USE IN CANADA AND U.S.A.
MODEL: I1100S
TESTED TO:
ULC S628-M93 / UL 1482-1998 / ULC S627-00 / UL 737-2000 REPORT NO. 632-3198 (SEPT.1993)
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY IN MASONRY
ADJACENT SIDEWALL A) 15in / 380mm
FIREPLACE OR FACTORY BUILT FIREPLACE.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
F
A
ADJACEN
TSIDEWALL
MANTLE B) 20in / 510mm
TOP FACING C 14in / 355 mm
SIDE FACING D) 7.375in / 185mm
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5" (38mm)
ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR
MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E)
16" (405mm) TO FRONT AND (G) 8" (205mm) TO SIDES FROM FUEL
DOOR.
D
G
C
E
B
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
F
A
ADJ ACEN
TSIDEWALL
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
2007
20062005
LISTED FACTORY BUILT FIREPLACE INSERT
CERTIFIED FOR USE IN CANADA AND U.S.A.
MODEL: I3100L
TESTED TO:
ULC S628-M93 / UL 1482-1998 / ULC S627-00 / UL 737-2000 REPORT NO. 632-323500 (MAR.1994)
2005 2006 2007
fireplace or factory built fireplace. Contact local building or fire officials about restrictions and installation inspection in your area.
Install and use only in accordance with the manufactuerer's installation and operating instructions. Install and use only in masonry
Minimum Clearances to Combustibles
(Measured from insert body)
ADJACENT SIDEWALL A) 13"(330mm)
MANTLE B) 19"(480 mm)
COMPONENTS REQUIRED FOR INSTALLATION: 6" (150mm) STAINLESS STEEL LINER.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS, SCREEN DOOR
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT
USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR CLOSED,
OPEN TO FEED FIRE ONLY. REPLACE GLASS ONLY WITH CERAMIC GLASS (5mm). INSPECT AND CLEAN CHIMNEY
FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO NOT
TOP FACING C) 18"(455 mm)
SIDE FACING D) 6.5"(165mm)
OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
DATE OF MANUFACTURE
(Duplicate Serial #)
DATE OF MANUFACTURE
COMPONENTS REQUIRED FOR INSTALLATION: 6IN / 150MM STAINLESS STEEL LINER.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS, SCREEN DOOR
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE
OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR CLOSED, OPEN TO FEED FIRE ONLY.
MADE IN CANADA
REPLACE GLASS ONLY WITH CERAMIC GLASS (5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN
CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
Regency Wood Insert & Hearth Heater4
908-343b rev. 11/05
SAFETY LABEL
This is a copy of the label that accompanies each Regency Hearth Heater. We have printed a copy of the contents here for your review.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
SAFETY LABEL FOR H2100M
CAUTION
HOT WHILE IN OPERATION
DO NOT TOUCH. KEEP CHILDREN,
INSTRUCTIONS.
SKIN BURNS. READ ABOVE
CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE
UNITED STATES ENVIRONMENTAL PROTEC-
TION AGENCY CERTIFIED TO COMPLY WITH
JULY 1990, PARTICULATE EMISSION STAND-
ARDS.
908-389b 11/05
MANUFACTURED BY:
DO NOT REMOVE THIS LABEL
103
103
(Duplicate Serial #)
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5 IN / 38 MM ABOVE
AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST BE PRO-
TECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E) 18 IN / 455 MM TO
FRONT AND (G) 6 IN / 150 MM TO SIDES.
COMPONENTS REQUIRED FOR INSTALLATION MUST HAVE A 6IN/150MM
D
C
B
A
TSIDEWALL
LISTED FACTORY BUILT FIREPLACE ACCESSORY HEARTH STOVE
CERTIFIED FOR USE IN CANADA AND U.S.A.
MODEL: H2100M
TESTED TO: ULC S628-M93 / UL 1482-1998 REPORT NO. 6255 (JULY 1991)
6988 VENTURE ST. DELTA, BC V4G 1H4
FIREPLACE PRODUCTS INTERNATIONAL LTD.
STAINLESS STEEL LINER.
G
E
F
ADJACEN
JAN FEB MA R APR MA Y JUN JUL AUG SEPT OCT NOV DEC
2005 2006 2007
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR
ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR CLOSED, OPEN TO FEED FIRE ONLY.
REPLACE GLASS ONLY WITH CERAMIC GLASS (5 MM).
INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO
ADJACENT SIDEWALL A) 10 in / 255 mm
MANTEL B) 2 5 in / 635 mm
TOP FACING C) 14 in / 355 mm
SIDE FACING D) 8.5 in/ 216mm
HEARTH EXTENSION (DEPTH) E) 18 in / 455 mm
HEARTH EXTENSION (ELEVATION) F) 1.5 in/ 38 mm
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY)
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY IN MASONRY FIREPLACE OR
FACTORY BUILT FIREPLACE.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
HEARTH EXTENSION (WIDTH) G) 6 in / 150 mm
NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
DATE OF MANUFACTURE
MADE IN CANADA
Regency Wood Insert & Hearth Heater 5
INSTALLATION
Regency Inserts are constructed with the high­est quality materials and assembled under strict quality control procedures that insure years of trouble free and reliable performance.
It is important that you read this manual thor­oughly and fully understand the safe instal­lation and operating procedures. The more you understand the way your Regency Insert operates, the more enjoyment you will experi­ence from knowing that your unit is operating at peak performance.
BEFORE INSTALLING
YOUR INSERT
1) Read all instructions before installing and
using your fi replace insert. Install and use only in accordance with manufacturer’s installation and operating instructions.
2) Check your local building codes - Building
Inspection Department. You may require a permit before installing your insert. Be aware that local codes and regulations may override some items in the manual.
WARNING: Careless installation is the
major cause of safety hazard. Check all local building and safety codes before installation of unit.
3) Notify your home insurance company that
you plan to install a fi replace insert or hearth heater.
4) Your fi replace insert is heavy and requires
two or more people to move it safely. The insert can be badly damaged by mishan­dling.
5) If your existing fi replace damper control
will become inaccessible once you have installed your Regency Insert, you should either remove or secure it in the open posi­tion.
6) Inspect your fi replace and chimney prior
to installing your insert to determine that it is free from cracks, loose mortar or other signs of damage. If repairs are required, they should be completed before installing your insert. Do not remove bricks or mortar from your masonry fi replace.
7) Do not connect the insert to a chimney
system servicing another appliance or an air distribution duct.
Emissions from burning wood or gas could contain chemicals known to the State of Cali­fornia to cause cancer, birth defects or other reproductive harm.
CHIMNEY
SPECIFICATIONS
Before installing, check and clean your chimney system thoroughly. If in doubt about its condi­tion, seek professional advice. Your Regency Insert is designed for installation into a masonry fi replace that is constructed in accordance with the requirements of "The Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Ap­pliance", N.F.P.A. 211, the National Building Code of Canada, or the applicable local code requirements.
The appliance, when installed, must be electri­cally grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.
Regency Inserts are designed with a 6" (152mm) fl ue.
Requirements for Installing
Solid-fuel Inserts in Factory-built
Fireplaces.
1) The insert must be tested and meet the
requirements of UL 1482 (U.S.) and or ULC S628 (Canada) when tested in a masonry fi replace built per ULC S628.
2) The factory-built fi replace must be listed per
UL 127 or ULC S610.
3) Clearances obtained from the masonry fi re-
place tests are also relevant for installation in factory-built fi replaces.
4) Installation must include a full height listed
chimney liner type HT requirements (2100 degree F.) per UL 1777 (U.S.) or ULC S635 (Canada). The liner must be securely attached to the insert fl ue collar and the chimney top.
5) Means must be provided to prevent room
air passage to the chimney cavity of the fi replace. This may be accomplished by sealing the damper area around the chimney liner, or sealing the fi replace front.
6) Alteration of the fi replace in any manner is not
permitted with the following exceptions;
a. external trim pieces which do not affect
the operation of the fi replace may be removed providing they can be stored on or within the fi replace for re-assembly if the insert is removed.
b. the chimney damper may be removed
to install the chimney liner.
7) Circulating air chambers (i.e. in a steel
fi replace liner or metal heat circulator) shall not be blocked.
8) Means must be provided for removal of the
insert to clean the chimney fl ue.
9) Inserts that project in front of the fi replace
must be supplied with appropriate supporting means.
10) Installer must mechanically attach the sup-
plied label to the inside of the fi rebox of the fi replace into which the insert is installed.
"WARNING: This fi replace has been converted for use with a wood insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fi replace re-approved by the authority having jurisdiction."
In order for a solid-fuel insert to be certifi ed for use in factory-built fi replaces, the above information must be clearly stated in the instal­lation manual and appropriate markings. Final approval is contingent on the authority having jurisdiction.
FIREPLACE
SPECIFICATIONS
Your fi replace opening requires the following minimum sizes:
Height Width Depth Small (I1100S) 20" 23" 13.25" Large (I3100L) 25" 28" 17" Hearth Heater (H2100M) 20.0" -- --
Two faceplates are available to seal the fi re­place opening:
Standard Oversize Small (I1100S) 36"W x 26"H 39.875"W x 30"H
Large (I3100L) 44"W x 32"H 50"W x 34.5"H
Hearth Heater (H2100M) 40 1/4"W x 30"H 48"W x 33"H
INSTALLING YOUR
INSERT
Your insert is very heavy and will require two or three people to move it into position. The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges. Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation.
Convection Grills for
I3100L
The convection grills are installed before the unit is positioned inside the fi replace.
Regency Wood Insert & Hearth Heater6
Loading...