Regency HZ33CE, HZ33CE-LP10, HZ33CE-NG10 User Manual

Page 1
HZ33CE Gas Fireplace
Non-combustibl
26-1/16"
NAILING STRIP
2-1/2"
[64mm]
742mm
29-1/4"
Model HZ33CE-NG10 HZ33CE-LP10
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 11” W.C. (2.73 kPa)
Manifold Pressure - High 3.5” W.C. (0.87 kPa) 10” W.C. (2.48 kPa)
Manifold Pressure - Low 1.6” W.C. (0.41 kPa) 6.4” W.C. (1.59 kPa)
Orice Size -Altitude 0-4500 ft. #47 DMS #56 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
Flex Vent Systems: FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems: Simpson Direct Vent Pro®
16"
407mm
12,000 BTU/h
(3.51 kW)
17,000 BTU/h
(4.98 kW)
4” x 6-7/8” - Flex
4” x 6-5/8” - Rigid
Approved Venting Systems
American Metal Products® Amerivent Direct Security Secure Vent® Selkirk Direct-Temp™ Metal-Fab® Sure Seal
23"
584mm
12,500 BTU/h
(3.66 kW)
15,000 BTU/h
(4.39 kW)
4” x 6-7/8” - Flex
4” x 6-5/8”- Rigid
Header
(steel stud
on edge)
M
e
H
I
G
J
DETAILN
SCALE1:6
2X4HEADER
N
N
16"
(406mm)
NAILING STRIP
34-9/16" [878mm]
26"
660mm
29-7/16"
747mm
26-1/16"
543mm
21-3/8"
3"
(76mm)
2-1/2"
[64mm]
29-1/4"
742mm
K
O
L
29-1/4"
742mm
Framing
Description HZ33CE
Dimensions
G Framing Width 35"(889mm)
H Framing Height * 31-3/4" (806mm)
I Framing Rise from Floor 0" (when not using a surround)
2" min (when using Casandra Surround )
3-5/16" min (when using Verona Faceplate)
J * For Finish with
Tile Surround
K Corner Wall Length 38-15/16" (988mm)
L Corner Facing Wall Width 55-1/2" (1410mm)
Framing Depth Vertical Horizontal
22-3/4" (578mm) Vertical Rise
19-3/4" (502mm) Rigid / 16" (406mm) Flex
M Framed Chase Ceiling* 36" (914mm) Rigid 32"
N
O
Vent Centerline Height* 30" (762mm) Rigid 26"
Gas Connection Height* 1 1/2" (38mm)
P Gas Connection Inset* 7-3/16" (183mm)
Q Gas Connection Width* 3" (76mm)
* Measured from base of unit.
J
Floor
P
Q
Opening for gas
connection
I
(812mm)
Flex
(660mm)
Flex
Page 2
HZ33CE Gas Fireplace
C
F
G
C
Close to Ceiling
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this replace and vent system be installed only in accordance with these instructions.
The top, back and sides of the fireplace are defined by
Caution Requirements
standoffs. The metal ends of the standoff may NOT
be recessed into combustible construction.
Fire hazard is an extreme risk
WARNING
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this replace and vent
system be installed only in accordance with these instructions.
Clearance: Dimension Measured From:
A: *Front Floor Clearance (min.)
B: *Sidewall (on one side)
C: *Ceiling (room and/or alcove)
D: Alcove Width
E: Alcove Depth
F: Mantel
G: Mantel Clearances
9" (229mm) Side Opening of Unit
30" (762mm) Top Opening of Unit
84" (1219mm) Sidewall to Sidewall (Minimum)
36" (914mm) Front to Back Wall (Maximum)
12" (305mm)
15-3/4" (400mm)
0" Underside of Unit
From Top Opening of Unit
Flue Clearances
Horizontal - Top 2-1/2"
Horiztonal - Side 1-1/2"
Horiztonal - Bottom 1-1/2"
Vertical (Flex Vent) 1-1/2"
Vertical (Rigid) 1-1/4"
Page 3
MANTEL CLEARANCES
Top View
0-3
Allowable mantel leg projection
6-3/4"
9"
Side opening of Unit
HZ33CE Gas Fireplace
Due to the extreme heat this replace emits, the
mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the paint may discolour.
12
16
14
12
10
15-3/4" (400mm)
8
6
4
2
0
Mantel Clearances
6
810
12" (305mm)
7-1/2"(191mm)
0 - 3-1/2" (89mm)
13-3/4"(349mm)
24-1/4"(616mm)
to floor
4
2
11-3/4"(298mm)
Top opening of Unit
0
Drywall
Non-combustible material
3"(76mm)
Standoff
Combustible mantel leg clearances from side of unit as per diagram:
Side View
MANTEL LEG CLEARANCES
Page 4
29-7/16"
747mm
21-3/8"
[542mm]
Combustible Material
Non-combustible Finishing Material (ie. tile)
Non-combustible Material (3-1/2" x 34-9/16")
Finishing Material (ie. tile)
Nailing Strip
-1/2" back from unit face
Combustible Material
Non-combustible
Supplied with Unit
1-1/2
(38mm)
Ensure finished material is brought to lip
HZ33CE Gas Fireplace
FRAMING & FINISHING
1. There are 8 (eight) side nailing strips and one top nailing strip available on the unit. One set of four (4) are for a clean finish installation, the other set
are for a tile finish installation as they are set back 1/2" (13mm). The top nailing strip is adjustable to 1/2" (13mm).
2. Bend the required four (4) nailing strips to 90º.
3. Attach top nailing strip with one (1) screw (located at the back of the nailing strip). Adjust to required position, flush or back 1/2" and tighten screw.
Adjustable Top Nailing
Strip
Nailing strip for Clean
Finish (set ush with unit)
Nailing strip for Tile Finish (set back 1/2")
Nailing strip for Tile Finish (set back 1/2")
Nailing strip for Clean
Finish (set ush with unit)
1. Frame in the enclosure for the unit with framing material.
Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.
2. For exterior walls, insulate the enclosure to the same degree as the rest of the house; apply vapour barrier and drywall, as per local installation codes.
WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems
3. The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances"
4. Tile Finish Option 1: Drywall may be installed onto the unit as shown below to create a surface to apply finishing materials such as tile, slate, etc.
Drywall cannot extend beyond the metal surface of the unit.
5. Tile Finish Option 2: If applying a non-combustible finishing material (tile,slate,etc) the material can be installed directly onto the metal surface (clean
(Do not insulate the replace itself.)
including, but not limited to: excessive condensation on glass doors, poor ame package, carbon, blue ames etc. These are not product
related issues.
section. Combustible materials can be laid against the side and back standoffs and the stove base.
front) of the unit in the area shown below.
TILE FINISH
Page 5
29-7/16"
747mm
21-3/8"
[542mm]
NO FACING OR
FINISHING MATERIAL
IN THIS AREA
No Combustible
Materials in this Area
33-7/16"
[849mm]
34-9/16" 878mm
2-1/2"
[64mm]
5-3/16"
[132mm]
NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
3-1/2" [89mm]
29-7/16"
747mm
21-3/8"
[542mm]
J Style trim or metal corner bead may be used to finish edges
No Combustible
Materials in this Area
Combustible
Material
Non-combustible Finishing Material
Non-combustible Material (3-1/2" x 34-9/16")
Finishing Material
Nailing Strip
-flush with unit
Combustible Material
Non-combustible
Supplied with Unit
1-1/2
(38mm)
Ensure finished material is brought to lip
HZ33CE Gas Fireplace
CLEAN FINISH
6. If applying a non-combustible facing it may be installed over the metal surface (clean front) of the unit in the area shown below.
WOOD STUD
1/2" DRYWALL
DO NOT EXTEND DRYWALL ONTO METAL SURFACE OF UNIT.
3-1/2"
NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
34-9/16"
878mm
33-7/16"
[849mm]
Combustible and Non-combustible Facing and Finishing Materials around unit.
NOTE: The 3-1/2" x 34-9/16" non combustible material supplied with this unit can be replaced if trying to achieve a clean finish. A large piece of non
combustible material (ie. 4' x 8' x 1/2") can be used to eliminate taped seams on or near unit.
7. Non-combustible material (ie. tile, slate, etc.) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this will assure ease of glass door removal and access to the lower panel.
NOTE: Non-combustible finishing materials may be of any thickness desired.
[89mm]
NON-COMBUSTIBLE FACING FOR CLEAN LOOK (ie. PAINTED FINISH)
1/2" DRYWALL
Minimum Clearances for Finishing Materials
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into nal position - it is important to know the total thickness / height of nished hearth (tile, carpet, etc.) The base of the replace, 4 sided faceplate or mantel should be level or higher than the nished hearth height.
Trim materials
Note: All non-combustible facing material should butt up cleanly
Rough edges may be visible from an angle.
To maintain a clean finished edge - facing material edges
IMPORTANT: Materials used must be NON-COMBUSTIBLE.
to the flanges around the firebox opening.
may be finished with a J-style trim or metal cornerbead (both materials available at your local building or hardware store).
Page 6
HZ33CE Gas Fireplace
RIGID PIPE VENTING ARRANGEMENTS
Vertical Terminations
(Propane & Natural Gas)
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using one 90o elbow, with rigid pipe vent systems for Propane and Natural Gas.
• Unit must be raised 1".
• Firestops are required at each oor level and whenever passing through a wall.
• Maintain clearances to combustibles.
• Vent must be supported at o󰀨sets.
Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994.
Page 7
HZ33CE Gas Fireplace
16
2
4
6
8
10
12
14
2
0
0
12
20
6
14
30” (762mm) / 26” (660mm) when using flex Minimum Height Requirement
4
8
10
18
16
Vertical Height (Feet)
Horizontal (Feet)
8"(0.2m)
2 (0.6m)
RIGID PIPE VENTING ARRANGEMENTS
Horizontal Terminations
®
REGENCY
This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45o and one 90o elbow (two 45o elbows equal one
o
90
elbow).
Note: Must use optional rigid pipe adaptor (Part # 510-994. when using rigid pipe vent systems. (Refer "Rigid Pipe Venting Systems" Section)
DIRECT VENT SYSTEM (FLEX)
(Propane & Natural Gas)
Minimum
Simpson Dura-Vent Center-Line
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
Note: Regency
®
Direct Vent System (Flex) is only approved for horizontal terminations.
• Maintain clearances to combustibles.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each oor level and whenever passing through a wall.
Minimum
Flex Kit Center-Line