WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919-120a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
HZ33CE Video
www.regency-fi re.com
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any applianceDo not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
11/13/13
To the New Owner:
Congratulations!
You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The HZ33CE has been
designed to provide you with all the warmth and charm of a fi re at the fl ick of a switch. The model
HZ33CE has been approved by Warnock Hersey for both safety and effi ciency. As it also bears
our own mark, it promises to provide you with economy, comfort and security for many trouble
free years to follow. Please take a moment now to acquaint yourself with these instructions and
the many features of your Regency
®
Fireplace.
Horizon Benefi ts VideoHZ33CE Video
2
Regency HZ33CE Gas Fireplace
MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regency® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED
GAS FIREPLACE HEATERS ANSI Z21.88 - 2009 / CSA 2.33 - 2009 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN
/ CGA 2.17-M91.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home
Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes
follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current
CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local
codes.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited
by local codes.
This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases,
unless a certifi ed kit is used. (Kit # 434-972).
Ensure that structural members are not cut or weakened during installation.
Regency HZ33CE Gas Fireplace
3
TABLE OF CONTENTS
SAFETY LABEL
Copy of Safety Decal .....................................................5
REQUIREMENTS
MA Code - CO Detector.................................................6
DIMENSIONS
Unit Dimensions ............................................................7
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliancemust be installedin accordance with the Standard CAN/CSAZ240 MH,Mobile Housing, in Canada, or withthe Manufactured HomeConstruction and SafetyStandard, Title 24CFR, Part 3280,in the
United States,or whensuch a standardis notapplicable, ANSI/NCSBCSA225.1/NFPA501A, Manufactured HomeInstallations Standard
This appliance is onlyfor use with the type of gasindicated on the rating plate and maybe installed in an aftermarket, permanently located,manufactured (mobile) home where notprohibited by local codes. See
owner's manualfor details.
Installer l'appareilselon lescodes ou règlementslocaux, ou,en l'absence detels règlements,selon les codesd'installation ANSIZ223.1, NationalFuel Gas Codeou CSA-B149.1en vigueur.
Installer l'appareilselon la normeCAN/CSA-Z240,Série MM, Maisonmobiles ou CAN/CSA-Z240VC, Véhiculesdecamping, ou lanorme 24 CFRPart 3280,Manufactured Home Constructionand Safety Standard.
Si cesnormes nesont pas pertinentes,utilisez lanorme ANSI/NCSBCSA225.1/NFPA501A, Manufactured HomeInstallations Standard.
Cet appareil doitêtre utilize uniquement avec letype de gaz indiqué surla plaque signalétique. Cet appareilpeut être installé dans unemaison préfabriquée ou mobile (É.-U.seulement) installée à demeure siles
règlements locauxle permettent.Voir lanotice de l'utilisateurpour plusde renseignements. Cetappareil nepeut pas êtreutilisé avecd'autres gaz saufsi unetrousse de conversioncertifiée estfournie.
This ventedgas fireplaceheater is notfor usewith air filters.Nepas utiliser defiltre àair avec cefoyer augaz à évacuation.
For usewith glassdoors certified withthe applianceonly
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev e
Pression a la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Califorique minimum selon
é
D bit Caliorfique maximum selon
é
l'altitude
APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev e
Pression a la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Califorique minimum selon
é
D bit Caliorfique maximum selon
é
l'altitude
Pour utilisationuniquement avecles portes enverre certifiéesavec l'appareil
ééé
é
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.FOYER AU GAZ À ÉVACUATION -
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
Minimum Clearances to Combustibles
Modéle-NG
HZ33CE
Modéle-LP
HZ33CE
ééé
é
Degagement Minimum De Materiaux Combustibles
Ceiling
A
C
DOOR SEAL: Please check that
the door is properly sealed
(See Instruction Manual for Detailed Instructions)
Electrical supply/ Électrique115VAC,1.13A, 60Hz.
Made in Canada / Fabrique au Canada
406
Serial No./ No de serie
406
0" Clearance to
combustibles from:
Sides, bottom and rear of unit
*Top - 3-1/2" (89mm) non-combustible
material required above unit.
Wall
Ceiling Clearances from
Top Opening of Unit:
(A) 30" (762mm)
Side Wall Clearance from
Side Opening of Unit:
B) 9"(229mm)
Floor Clearance:
Floor
FPI Fireplace Products International Ltd.
C) 0”
Alcove Clearances
D)E)Min. Width 84" (1219mm)
Max. Depth 36" (914mm)
Delta, BC, Canada
919-119
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Regency HZ33CE Gas Fireplace
5
REQUIREMENTS
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
MA Code - CO Detector
(for the State of Massachusetts only)
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and
detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of
the installation.
6
Regency HZ33CE Gas Fireplace
16"
3
m
407mm
23"
584mm
DIMENSIONS
UNIT DIMENSIONS
34-9/16"
[878mm]
16"
(406mm)
26"
660mm
29-7/16"
747mm
4 SIDED FACEPLATE DIMENSIONS
543mm
21-3/8"
3"
(76mm)
NAILING STRIP
29-1/4"
742mm
MANTEL DIMENSIONS
26-1/16"
(662mm)
2-1/2"
[64mm]
29-1/4"
742mm
42-5/16"
(1074mm)
Regency HZ33CE Gas Fireplace
6-3/8"
(162mm)
36-3/4"
(933mm)
2"
(51mm)
47-9/16"
9"
(229mm)
(1207mm)
29-9/16"
(750mm)
52-1/8"
(1324mm)
9"
(229mm)
21-1/2"
(545mm)
35-1/2"
(901mm)
5-1/8"
(130mm)
5"
(127mm)
8-1/8"
(206mm)
(76
7
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The HZ33CE™ Fireplace must be installed in
accordance with these instructions. Carefully read
all the instructions in this manual fi rst. Consult the
"authority having jurisdiction" to determine the need
for a permit prior to starting the installation. It is the
responsibility of the installer to ensure this fi replace
is installed in compliance with manufacturers
instructions and all applicable codes.
BEFORE YOU ST ART
Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD
BE DONE BY AN AUTHORIZED
SERVICE PERSON. THE APPLIANCE
SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A
PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE
IN THE SAME AREA AS THE APPLIANCE. TODDLERS, YOUNG CHILDREN
AND OTHERS MAY BE SUSCEPTIBLE
TO ACCIDENTAL CONTACT BURNS. A
PHYSICAL BARRIERS IS RECOMMENDED IF THERE ARE AT RISK INDIVIDUAL
IN THE HOUSE. TO RESTRICT ACCESS
TO A FIREPLACE OR STOVE, INSTALL
AN ADJUSTABLE SAFETY GATE TO
KEEP TODDLERS, YOUNG CHILDREN
AND OTHER AT RISK INDIVIDUALS OUT
OF THE ROOM AND AWAY FROM HOT
SURFACES.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
ANY SAFETY SCREEN, GUARD, OR
BARRIER REMOVED FOR SERVICING
THE APPLIANCE, MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE.
IF THE BARRIER BECOMES DAMAGED,
THE BARRIER SHALL BE REPLACED
WITH THE MANUFACTURER'S BARRIER
FOR THIS APPLIANCE.
GENERAL SAFETY
INFORMATION
1. The appliance installation must conform with
local codes or, in the absence of local codes,
with the current Canadian or National Gas
Codes, CAN1-B149 or ANSI Z223.1 Installation
Codes.
2. The appliance when installed, must be electri-
cally grounded in accordance with local codes,
or in the absence of local codes with the current
National Electrical Code, ANSI/NFPA 70 or CSA
C22.1 Canadian Electrical Code.
3. See general construction and assembly in-
structions. The appliance and vent should be
enclosed.
4. This appliance must be connected to the speci-
fi ed vent and termination cap to the outside of
the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is fi tted as per Venting instructions.
5. Inspect the venting system annually for blockage
and any signs of deterioration.
6. Venting terminals shall not be recessed into a
wall or siding.
7. Any safety glass removed for ser vicing must be
replaced prior to operating the appliance.
8. To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fi replace.
9. Wear gloves and safety glasses for protection
while doing required maintenance.
10. Be aware of electrical wiring locations in walls
and ceilings when cutting holes for termination.
11. Under no circumstances should this appliance
be modifi ed. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
12. Installation and any repairs to this appliance
should be done by an authorized service person. A professional service person should be
called to inspect this appliance annually. Make
it a practice to have all of your gas appliances
checked annually.
13. Do not slam shut or strike the glass door.
14. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
15. The appliance area must be kept clear and
free of combustible materials, (gases and other
fl ammable vapours and liquids).
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
8
Regency HZ33CE Gas Fireplace
INSTALLATION
INSTALLATION
CHECKLIST
1. Locate appliance:
a) Room location (Refer to "Locating Your
Gas fi replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Mantel
Clearances" section)
d) Framing & Finishing Requirements
(Refer to "Framing & Finishing" section)
e ) Venting Requirements (Refer to "Venting"
section)
2. Assemble Top and Side Standoffs (Refer to
"Unit Assembly Prior to Installation).
3. Slide unit into place.
4. Install vent (Refer to "Venting Arrangement"
sections).
5. Make gas connections (Refer to "Gas Line
Installation section).
6. Test the pilot (Refer to "Pilot Adjustment"
section).
7. Test Gas Pressure (Refer to "Gas Pipe Pres-
sure Testing" section).
8. Install 4 AA batteries in the battery pack or
optional AC power adaptor.
9. Install standard and optional features. Refer
to the following sections:
This includes:
1. Clocking the appliance to ensure the correct
fi ring rate (rate noted on label), after burning
appliance for 15 minutes.
2. If required, adjusting the primar y air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
LOCATING YOUR
GAS FIREPLACE
1. When selecting a location for your fi replace,
ensure that the clearances are met.
2. The appliance must be installed on a fl at,
solid, continuous surface For example a
wood, metal or concrete fl oor or in a raised (on
the wall) application. The appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.
3. The HZ33CE Gas Fireplace can be installed
in a recessed position or framed out into the
room as in A, B, C and D. See Diagram 1.
A) Flat on Wall
4. This appliance is Listed for bedroom
installations when used with a listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
5. The HZ33CE Gas Fireplace is approved for
alcove installations, see "Clearances" section
for details.
6. We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For vent terminations refer to "Exterior
Vent T ermination Locations" section.
a) Optional Refl ective Panels
b) Glass Crystals or Optional Ceramic
Stones
c) Remote Control or Wall Thermostat
10. Wall Mounted ON/OFF Switch:
Use the toggle wall switch supplied with the
manual package. Use of a “decor” switch
causes higher resistance which is a problem
on gas fi replaces.
11. Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly and operation fully explained to customer.
Diagram 1
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner
Regency HZ33CE Gas Fireplace
9
INSTALLATION
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in accordance with these instructions.
The top, back and sides of the fi replace are defi ned by
Caution Requirements
standoffs. The metal ends of the standoff may NOT
be recessed into combustible construction.
C
F
G
Fire hazard is an extreme risk
WARNING
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fi replace and vent
system be installed only in accordance with these instructions.
C
Clearance:DimensionMeasured From:
A: *Front Floor Clearance (min.)
B: *Sidewall (on one side)
Due to the extreme heat this fi replace emits, the
mantel clearances are critical. Combustible mantel
clearances from top of front facing are shown in the
diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the
paint may discolour.
12
16
14
12
10
15-3/4" (400mm)
8
6
4
2
0
Mantel Clearances
6
810
12" (305mm)
7-1/2"(191mm)
0” - 3-1/2" (89mm)
13-3/4"(349mm)
24-1/4"(616mm)
to floor
4
2
11-3/4"(298mm)
Top opening
of Unit
0
Drywall
Non-combustible material
3"(76mm)
Standoff
MANTEL LEG CLEARANCES
Combustible mantel leg clearances from side of unit as per diagram:
Top View
Side opening of Unit
Side View
0-3
6-3/4"
Allowable mantel leg projection
9"
Regency HZ33CE Gas Fireplace
11
INSTALLATION
FRAMING & FINISHING
1. There are 8 (eight) side nailing strips and one top nailing strip available on the unit. One set of four (4) are for a clean fi nish installation, the other set are
for a tile fi nish installation as they are set back 1/2" (13mm). The top nailing strip is adjustable to 1/2" (13mm).
2. Bend the required four (4) nailing strips to 90º.
3. Attach top nailing strip with one (1) screw (located at the back of the nailing strip). Adjust to required position, flush or back 1/2" and tighten screw.
Adjustable Top
Nailing Strip
Nailing strip for
Clean Finish (set
fl ush with unit)
Nailing strip for
Nailing strip for
Tile Finish (set
back 1/2")
Tile Finish (set
back 1/2")
Nailing strip for
Clean Finish (set
fl ush with unit)
1. Frame in the enclosure for the unit with framing material.
Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.
2. For exterior walls, insulate the enclosure to the same degree as the rest of the house; apply vapour barrier and drywall, as per local installation codes.
(Do not insulate the fi replace itself.)
WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems
including, but not limited to: excessive condensation on glass doors, poor fl ame package, carbon, blue fl ames etc. These are not product
related issues.
3. The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances"
section. Combustible materials can be laid against the side and back standoffs and the stove base.
4. Tile Finish Option 1: Drywall may be installed onto the unit as shown below to create a surface to apply fi nishing materials such as tile, slate, etc.
Drywall cannot extend beyond the metal surface of the unit.
5. Tile Finish Option 2: If applying a non-combustible fi nishing material (tile,slate,etc) the material can be installed directly onto the metal surface (clean
front) of the unit in the area shown below.
TILE FINISH
Combustible
Material
21-3/8"
[542mm]
Non-combustible
Finishing Material
(ie. tile)
Ensure finished
material is
brought to lip
Non-combustible Material (3-1/2" x 34-9/16")
Nailing Strip
-1/2" back from unit face
Supplied with Unit
12
29-7/16"
747mm
Non-combustible
Finishing Material
(ie. tile)
1-1/2
(38mm)
Combustible
Material
Regency HZ33CE Gas Fireplace
INSTALLATION
CLEAN FINISH
6. If applying a non-combustible facing it may be installed over the metal surface (clean front) of the unit in the area shown below.
1/2" DRYWALL
3-1/2"
NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
34-9/16"
878mm
33-7/16"
[849mm]
Combustible and Non-combustible Facing and Finishing
Materials around unit.
[89mm]
WOOD STUD
DO NOT EXTEND
DRYWALL ONTO METAL
SURFACE OF UNIT.
NON-COMBUSTIBLE FACING
FOR CLEAN LOOK
(ie. PAINTED FINISH)
1/2" DRYWALL
Non-combustible
Finishing Material
Ensure finished
material is
brought to lip
Non-combustible
Finishing Material
Combustible
Material
Non-combustible Material (3-1/2" x 34-9/16")
Nailing Strip
-flush with unit
1-1/2
(38mm)
Combustible
Material
Supplied with Unit
NOTE: The 3-1/2" x 34-9/16" non combustible material supplied with this unit can be replaced if trying to achieve a clean fi nish. A large piece of non com-
bustible material (ie. 4' x 8' x 1/2") can be used to eliminate taped seams on or near unit.
7. Non-combustible material (ie. tile, slate, etc.) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this
will assure ease of glass door removal and access to the lower panel.
NOTE: Non-combustible fi nishing materials may be of any thickness desired.
NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
No Combustible
Materials in this Area
3-1/2"
[89mm]
5-3/16"
[132mm]
No Combustible
Materials in this Area
[849mm]
33-7/16"
[542mm]
NO FACING OR
21-3/8"
FINISHING MATERIAL
IN THIS AREA
29-7/16"
2-1/2"
[64mm]
747mm
34-9/16"
878mm
Minimum Clearances for Finishing Materials
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into fi nal position - it is important to know the
total thickness / height of fi nished hearth (tile, carpet, etc.) The base
of the fi replace, 4 sided faceplate or mantel should be level or higher
than the fi nished hearth height.
J Style trim or metal
corner bead may be
used to finish edges
29-7/16"
747mm
Trim materials
Note: All non-combustible facing material should butt up cleanly
to the fl anges around the fi rebox opening.
Rough edges may be visible from an angle.
To maintain a clean fi nished edge - facing material edges
may be fi nished with a J-style trim or metal cornerbead (both
materials available at your local building or hardware store).
IMPORTANT: Materials used must be NON-COMBUSTIBLE.
21-3/8"
[542mm]
Regency HZ33CE Gas Fireplace
13
INSTALLATION
DETAILN
SCALE 1 : 6
2X4 HEADER
N
Non-combustible
Header
(steel stud
on edge)
FRAMING DIMENSIONS
M
H
I
NOTE: If this is an outside corner, the
minimum distance between the vent
and the outside corner is 6" (15cm)
with AstroCap termination cap or 12"
(30cm) with Rigid Vent termination
cap.
(For example Dura-Vent)
Framing DimensionsDescriptionHZ33CE
GFraming Width35"(889mm)
HFraming Height *31-3/4" (806mm)
IFraming Rise from Floor0" (when not using a surround)
The HZ33CE uses the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer
liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing
warm room air up the chimney.
There are 5 vent systems approved for use with the HZ33CE: the Regency® Direct Vent Flex System for Horizontal Terminations only and the
Simpson Dura-Vent, Selkirk Direct-Temp, Amerivent Direct Vent and Security Secure Vent Systems for Horizontal and Vertical Terminations (see
following "Venting" Sections for more details).
Note: These fl ue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate
solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
(See "Rigid Pipe Venting System" for more details and exceptions).
NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met.
Regency HZ33CE Gas Fireplace
15
INSTALLATION
EXTERIOR VENT TERMINATION REQUIREMENTS
1
Minimum Clearance Requirements
AClearance above grade, veranda, porch, deck, or balcony12"(30cm)12"(30cm)
BClearance to window or door that may be opened 12"(30cm)9" (23cm)
CClearance to permanently closed window**
DVertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm)
from the center line of the terminal (check with the local code)
EClearance to unventilated soffi t15"(38cm)15"(38cm)
FClearance to outside corner: with AstroCap Termination Cap. 6"(15cm)6"(15cm)
Clearance to outside corner: with all other approved Termination Caps.12"(30cm)12"(30cm)
GClearance to inside corner: with AstroCap Termination Cap 6"(15cm) 6"(15cm)
Clearance to inside corner: with all other approved Termination Caps.12"(30cm)12"(30cm)
HClearance to each side of center line extended above meter/regulator assembly 36"(90cm)
JClearance to service regulator vent outlet36"(90cm)*
KClearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance12"(30cm)9" (23cm)
LClearance to a mechanical air supply inlet
#3' (91cm) above if within 10' (3m) horizontally.
MClearance above paved sidewalk or a paved driveway located on public property 84"(2.1m)
NClearance under veranda, porch, deck, or balcony 12"(30cm)
1
In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
┼
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor
Clearance in accordance with local installation codes and the requirements of the gas supplier
*
a
3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b
3 feet (91cm) above - if within 10 feet (3m) horizontally
Canada
18"(46cm)18"(46cm)
a
72"(1.8m)36"(90cm)
┼
‡
USA
*
*
*
2
b
16
Regency HZ33CE Gas Fireplace
INSTALLATION
REGENCY® DIRECT VENT FLEX SYSTEM
Horizontal Terminations Only
This venting system, in combination with the HZ33CE-4 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey.
The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section .
Regency® Direct Vent Flex Termination Kit (Part # 946-513. includes all the parts needed to install the HZ33CE with a maximum run of 2 feet. If
installing the HZ33CE-4 with a continuous vent length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) use Kit # 946-515 (4 ft) or 946-516 (10 ft) or
see "Rigid Pipe Venting Systems" Section for alternate venting arrangements.
AstroCap Flex Kits
1
6-7/8" dia. fl exible liner (kit length)
2
4" dia. fl exible liner (kit length)
3
spring spacers (3.
4
thimble (2.
5
AstroCap termination cap (1.
6
screws (12.
7
tube of Mill Pac (1.
8
plated screws (8.
9
screws #8 x 1-1/2" drill point,
stainless steel (4.
Notes:
1. Liner sections should be continuous
without any joints or seams.
2. Only Flex pipe purchased from Regency®
may be used for Flex installations.
MINIMUM
RIGID PIPE CENTER-LINE
Alternate
Horizontal
Termination
Caps
MINIMUM
FLEX KIT CENTER-LINE
Wherever necessary due to
external location of cap, the
AstroCap can be replaced
with the FPI Riser Vent T ermination Cap.
Note: - Unit must be raised by 1".
Regency HZ33CE Gas Fireplace
17
INSTALLATION
RIGID PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
The minimum components required for a basic
horizontal termination are:
1 AstroCap Horizontal Termination Cap
1 45o Elbow
1 Rigid Pipe Adaptor
1 Wall Thimble
1 Length of pipe to suit wall thickness
(see chart)
For siding other than vinyl, furring strips may
be used, instead of the vinyl siding standoff, to
create a level surface to mount the vent terminal.
The Terminal must not be recessed into siding.
If a Vinyl Siding Standoff is required (it must
be used with vinyl siding), measure to outside
surface of wall without siding and add 2 inches.
Do not combine venting components from
different venting systems.
Exception: However, use of the the AstroCap
and FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent , Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
TM
18
The FPI AstroCap
American Metal Products Ameri Vent Direct Vent, Security Secure Vent®, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace
Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
TM
and FPI Riser Vent terminal are cer tifi ed for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent,
Regency HZ33CE Gas Fireplace