Regency F3100 User Manual

F3100 Wood Stove
Wood Stoves
F3100 Large Stove
25-1/4”(641mm)
Minimum Clearance To Combustible Materials
Please read the section below carefully as clearances depend on whether the airmate or the rear heat defl ector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.
Residential Installation “C” Vent (Single Wall)
Unit From Unit From Corner
Wood Stoves
with Airmate 18” 12” 8.5” 32” 18.5” 22”
with Rear Defl ector 20” 14” 10.5” 34” 20.5” 24”
From Vent centerline
206 June 2007 Regency Product Specifi cations Book
Wood Stoves
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.
Unit From Unit From Corner
F3100 A B C D E F
with Airmate 16” 9.5” 8.5” 30” 16” 22”
with Rear Defl ector 20” 12” 8.5” 34” 18.5” 22”
Mobile Home Close Clearance (To be installed with required pipe components)
“C” Vent single wall pipe is not approved for Mobile Home installations. (Refer to mobile home instructions.)
Unit From Unit From Corner
F3100 A B C D E F
with Airmate 18” 9.5” 10” 32” 16” 23.5”
with Rear Defl ector 20” 12” 10” 34” 18.5” 23.5”
Minimum Alcove Clearance To Combustible Materials
From Vent centerline
From Vent centerline
F3100 Wood Stove
Floor Protection
A combustible fl oor must be protected by a non-combustible material (like tile, concrete board, or certifi ed to UL-1618 or as defi ned by local codes) extending beneath the heater and a minimum of 6" from each side and minimum 16" from the front face of the stove and minimum 6" (or the rear clearance to combustibles whichever is smaller) from the rear of the stove.
Minimum Overall Width (X) of Floor Protector for all installations:
Large Stove F3100 40"
Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84" Maximum depth of alcove - 36"
Unit From Unit
F3100 G H I J K L
with Airmate 16” 9.5” 30” 16” 60” 46.5”
with Rear Defl ector * * * * * *
From Vent centerline
Min.
Width
Min. Hearth
to Rear Wall
NOTE: In Canada, fl oor protection must extend 18" to the front
and 8" to each side of the stove.
Minimum Overall Depth (Y) of Floor Protector
Unit
F3100 Y Z Y Z Y Z Y Z
with Airmate 43” 6” 43” 6” 43” 6” 43” 6”
with Rear Defl ector 43” 6” 43” 6” 43” 6” N/A N/A
Residential
“C” Vent
Residential
Close
Clearance
Mobile
Home Close
Clearance
Alcove
Wood Stoves
* not approved for Alcove.
207June 2007 Regency Product Specifi cations Book