Regency CC40LE-NG, CC40LE-LP, CC40RE-NG, CC40RE-LP, City Series Owners & Installation Manual

...
Page 1
City Series
®
Zero Clearance Direct Vent Gas Fireplace
Owners &
www.regency-re.com
STYLE MODEL Left Corner CC40LE-NG / CC40LE-LP Right Corner CC40RE-NG / CC40RE-LP
Warning Fire or explosion Hazard
failure to follow safety warnings exactly could result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919-740a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
04.26.17
Page 2
To the New Owner:
Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The City Series are hand crafted appliances and have been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The CC40LE /CC40RE City Series have been approved by Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency® Fireplace.
This appliance may be installed in an aftermarket, permanently lo­cated, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible fore use with other gases, unless a certified kit is used.
2 | City Series
Page 3
MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regency® product has been tested and listed by Intertek as a Direct Vent Wall Furnace to the following standards: VENTED GAS DECORATIVE FIREPLACE CAN/CGA-2.17-M91, and ANSI Z21.50-2014 • CSA 2.22-2014 HIGH ALTITUDES CAN/CGA 2.17-M91.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This Regency® mobile/manufactured home listed appliance comes factory equipped with four 1/4" diameter holes located near each corner of the base. Fasten the fireplace in place using screw, inserted through the holes.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes. See the "Wiring Diagram" section.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket permanently located, manufactured home (U.S.A only) or mobile home, where not prohibited by local codes.
. and GAS-FIRED APPLIANCES FOR USE AT
This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Ensure that structural members are not cut or weakened during installation.
City Series | 3
Page 4
table of contents
Copy of Safety Decal .....................................................5
Installation................................................................9-60
Important Message ......................................................9
Before You Start .............................................................9
General Safety Information ..........................................10
Installation Checklist ....................................................10
Heatwave Duct System ...............................................10
Locating Your Gas Fireplace ........................................11
Unit Assembly Prior to Installation ...............................11
Clearances CC40LE/CC40RE .....................................13
Clearances CC40LE/CC40RE .....................................14
Clearances CC40LE/CC40RE .....................................15
Mantel Clearances CC40LE/CC40RE .........................16
Framing Dimensions CC40LE (Left Corner) ................17
Framing Dimensions CC40RE (Right corner) .............18
Wall Board/Drywall Installation CC40LE/CC40RE ......19
Framing and Finishing Inset Installations CC40LE/
CC40RE ......................................................................20
Optional Framing Kit Installation CC40LE/CC40RE ....21
Building additional framing off of the framing kit ..........24
Guidelines for installing a TV / artwork |above the unit 2 5
TV recessed into wall ..................................................25
Exterior Vent Termination Locations ............................26
4” x 6-5/8” Rigid Pipe Cross Reference Chart .............27
Wall Mount On / Off Switch and Battery Holder Installa-
tion ...............................................................................29
Required for all installations .......................................29
Vent Restrictor Position ...............................................30
Horizontal Terminations ...............................................31
Flex Vent 4" x 6-7/8" ....................................................31
Venting Introduction .....................................................32
Venting Arrangement for Horizontal Terminations .......32
Horizontal Terminations ...............................................33
Rigid Pipe 4" x 6-5/8" ...................................................33
Horizontal Terminations ...............................................34
Rigid Pipe 4" x 6-5/8" ...................................................34
Horizontal Venting with Two (2) 90o Elbows .................34
Horizontal Venting with Three (3) 90o Elbows ..............34
Vertical terminations
Rigid Pipe 4" x 6-5/8" ...................................................35
Venting Arrangement for Vertical Terminations ............36
Vertical Terminations Rigid Pipe 4" x 6-5/8" ...............37
Unit Installation with Horizontal Termination ...............38
4" x 6-5/8" venting .......................................................38
Unit Installation with Horizontal Termination ...............39
Dura-Vent
Horizontal terminations ................................................40
Dura-Vent Vertical Termination ....................................41
4" x 6-5/8" venting .......................................................41
Vertical Termination 4" x 6-7/8" venting .....................42
Vertical flue extension kit (part #946-756) ...................43
Ceiling Firestop / firestop spacer (part #946-757) .......43
High Elevation ..............................................................44
Gas Line Installation ....................................................44
Pilot Adjustment ...........................................................44
Gas Pipe Pressure Testing ..........................................44
885 S.I.T. Valve Description .........................................44
Wiring Diagrams ..........................................................45
Inner glass panel (firebox glass) Installation / removal 46 Outer safety glass panel (barrier glass) Installation /
removal ........................................................................48
Outer safety glass panel (barrier glass) Installation / re-
moval ...........................................................................49
LP Conversion Instructions ..........................................50
CC40LE/CC40RE Painted panel installation ...............52
Inner Panels - CC40LE/CC40RE.................................52
Outer Panels - CC40LE/CC40RE ................................52
CC40LE/CC40RE glass panel installation ...................53
CC40LE/CC40RE enamel panel installation ...............55
Burner and Firebox media options ..............................57
Optional driftwood Log set Installation .........................58
CC40LE/CC40RE - Removable drywall guides ...........60
Operating instructions..........................................61-63
First Fire ......................................................................61
Normal Operating Sounds of Gas Appliances .............61
Aeration Adjustment ....................................................61
Lighting Procedure ......................................................62
Shutdown Procedure ...................................................62
Copy of the Lighting Plate Instructions ........................63
Maintenance...........................................................60-62
Maintenance Instructions ............................................64
Log Replacement ........................................................64
Glass Gasket ...............................................................64
Glass ...........................................................................64
Glass replacement .......................................................64
Bulb Replacement .......................................................65
Valve Replacement ......................................................66
Parts List................................................................67-70
CC40LE main assembly ..............................................67
CC40RE main assembly .............................................69
Warranty............................................................................72-75
4 | City Series
Page 5
This is a copy of the label that accompanies Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the outer front panel is removed.
NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Copy of Safety Decal
safety decal
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible con­nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli­ances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.
City Series | 5
Page 6
requirements
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
6 | City Series
Page 7
CC40LE (Left Corner) dimensions
11
"
16
18
475mm
24
616mm
4"
102mm
3
47
8
1203mm
1
"
23
4
48"
1219mm
dimensions
"
1
"
8
587mm
"
1
4
183mm
7
16
291mm
3
6
4
171mm
"
7
11
"
5
17
"
8
448mm
15
"
7
8
200mm
7
1
1
10 "
"
16
4
382mm
261mm
"
3
8
873mm
34
3
14
"
4
375mm
Note: Height Dimension may vary depending on the height of the leveling legs.
Dimensions will appear as (inches)" / (metric)mm throughout this manual. The inches are rounded to the nearest 1/16" when converted, when greater accuracy is required, use the metric dimensions.
43
1108mm
42
1089mm
5
"
8
642mm
"
3
16
33
"
1
4
25
7
"
8
1
842mm
"
37
8
943mm
Note: These units are non-load bearing.
ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS.
City Series | 7
Page 8
dimensions
CC40RE (Right Corner) dimensions
3
23
587mm
47
1
"
8
"
8
1203mm
24
616mm
1
"
4
"
1
4
183mm
"
7
16
11
7
291mm
4"
102mm
48"
1219mm
43
1108mm
3
"
6
171mm
5
"
8
4
11
1
"
25
4
3
642mm
"
16
33
842mm
1
"
37
8
943mm
7
1
1
10
"
7
"
15 "
8
16
4
18
200mm
382mm
261mm
16
475mm
17 5/8"
[448mm]
"
"
3
8
873mm
34
7
42
Note: Height Dimension may vary depending on the height of the leveling legs.
Dimensions will appear as (inches)" / (metric)mm throughout this manual. The inches are rounded to the nearest 1/16" when converted, when greater accuracy is required, use the metric dimensions.
"
8
1089mm
Note: These units are non-load bearing.
8 | City Series
14
375mm
3
"
4
Page 9
installation
Important Message
SAVE THESE INSTRUCTIONS
City Series Direct Vent Fireplaces must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturer's instructions and all applicable codes.
Before You Start
Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE­CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CARE­FULLY SUPERVISED WHEN THEY ARE IN THE SAME AREA AS THE APPLI­ANCE. TODDLERS, YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS. A PHYSICAL BARRIERS IS RECOMMEND­ED IF THERE ARE AT RISK INDIVIDUAL IN THE HOUSE. TO RESTRICT ACCESS TO A FIREPLACE OR STOVE, INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS FROM THE HOT VIEWING GLASS IS PROVIDED WITH THIS APPLIANCE AND SHALL BE INSTALLED FOR THE PROTECTION OF CHILDREN AND OTHER AT-RISK INDIVIDUALS
ANY SAFETY SCREEN, GUARD, OR BARRIER REMOVED FOR SERVICING THE APPLIANCE, MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.
WE RECOMMEND REMOVING THE GLASS WITH THE GLASS VACUUM HOLDERS SUPPLIED BY THE MANU­FACTURER. LOWER THE GLASS TO REST IN A SAFE PLACE. THIS IS TO PREVENT DAMAGE TO THE GLASS EDGES. EXTRA CARE MUST BE TAKEN WHEN REMOVING/INSTALLING THE GLASS. BREAKAGE OR DAMAGE TO THE EDGE OF THE GLASS WHICH OCCURS AS A RESULT OF CARELESS HANDLING WILL NOT BE COVERED UNDER WARRANTY.
City Series | 9
IF THE BARRIER BECOMES DAMAGED, THE BARRIER SHALL BE REPLACED WITH THE MANUFACTURER'S BARRIER FOR THIS APPLIANCE.
Page 10
installation
General Safety Information
1. The appliance installation must conform with
local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.
2. See general construction and assembly
instructions. The appliance and vent should be enclosed.
3. This appliance must be connected to the
specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per Venting instructions.
4. Inspect the venting system annually for blockage
and any signs of deterioration.
5. Venting terminals shall not be recessed into a
wall or siding.
6. Any safety glass removed for servicing must
be replaced prior to operating the appliance.
7. To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fireplace.
8. Wear gloves and safety glasses for protection
while doing required maintenance.
9. Be aware of electrical wiring locations in walls
and ceilings when cutting holes for termination.
10. Under no circumstances should this appliance
be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.
11. Installation and any repairs to this appliance
should be done by a qualified service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.
12. Do not slam shut or strike the glass door.
13. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in this appliance.
14. The appliance area must be kept clear and
free of combustible materials, (gases and other flammable vapours and liquids).
Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
Installation Checklist
1. Locate appliance. Refer to the following sections:
a) Locating Your Fireplace b) Clearances c) Combustible Mantel Clearances d) Framing & Finishing e) Venting. See the "Venting Introduction" to
"Venting Arrangements" sections.
2. Assemble Standoffs. Refer to the "Unit Assem­bly Prior to Installation" section. (NOTE: must be done before installing unit into fireplace.)
3. Install vent. See the "Horizontal Installations"
to "Installation Procedures" sections.
4. Install 4 AA batteries into receiver battery box. Connect receiver to wiring marked receiver, this will enable operation of the appliance manually when position in "ON" position.
Note: The wire harness (marked receiver) is
located near the gas valve and will need to be routed to the exterior of the fireplace from either the left or right hand side of the appliance prior finishing.
5. Supply 120 volt power to appliance. This
will be required to operate lights and highly recommended to operate gas valve. AA Batteries serve as back up only if 120 volt power is lost.
6. Make gas connections. Test the pilot. Must be as
per diagram. Refer to the "Gas Line Installation" & "Pilot Adjustment" sections.
7. Install standard and optional features. Refer
to the following sections where applicable:
a. Safety Glass b. Firebox (inner) glass c. Log Set d. Fireglass e. Ceramic stones or other approved media f. Painted, enamel or glass panels (panels
required) g. Optional Framing Kit h. Heatwave Kit
8. Plug 3 prong plug for the lights into the
receptacle. The 3 prong plug will be located near the gas valve on the appliance.
9. Final check.
Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.
This includes:
1. Clocking the appliance to ensure the correct firing rate (rate noted on label 28,500 Btu/h NG/ LP) after burning appliance for 15 minutes.
2. If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
Heatwave Duct System Optional kit
The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Please Note: One adaptor kit #656-995 must be used with each 946-556.
The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.
10 | City Series
Page 11
installation
Locating Your Gas Fireplace
1. When selecting a location for your fireplace, ensure that the clearances are met.
2. The appliance must be installed on a flat, solid, continuous surface For example a wood, metal or concrete floor or in a raised (on the wall) ap­plication. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.
3. The CC40LE/CC40RE Direct Vent Gas Fire­place can be installed in a recessed position or framed out into the room as in A and B. See Diagram 1.
A
B
Unit Assembly Prior to Installation
Before you start
The CC40LE/CC40RE has 4 standoffs, 2 on one side and 2 at the back that need assembly before installation.
Side and back standoff assembly CC40LE/CC40RE
The standoffs are shipped in a flat position and must be folded into shape and attached.
Take each standoff off the unit by removing one screw and bend into the correct shape. Slot the 2 tabs of the stand off into the slots in the unit and attach the other end with one screw.
Standoff locations
CC40LE/CC40RE
Diagram 1
A) Corner Left B) Corner Right
4. For bedroom installations, check with local codes before installation. This appliance is offered with a remote control.
5. The CC40LE/CC40RE Direct Vent Gas Fire­place is approved for alcove installations, see "Clearances" section for details.
6. We recommend that you plan your installa­tion on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.
Note: For vent terminations refer to "Exterior
Vent Termination Locations" section.
Back standoff assembly CC40LE/ CC40RE
Take each standoff off the unit by removing one screw. Bend into the correct shape (see above). Slot the 2 tabs of the stand off into the slots in the unit and attach the other end with one screw.
CC40LE/CC40RE
City Series | 11
Page 12
installation
Top nailing strip
Nailing strips CC40LE/CC40RE
Nailing strips are shipped folded flat against the unit. Fold nailing strips out 90º before installing unit. Secure nailing strips to framing using wood or metal screws.
Top Nailing strip CC40LE/CC40RE
Nailing strip is shipped with the appliance and will need to be attached. Note that the nailing strips are not required if using the optional chase or extended framing kit and may be recycled.
1. Secure nailing strip to appliance with 2 screws.
2. Secure nailing strips to framing using wood or metal screws.
Side nailing strip CC40LE
Top nailing strip
Side nailing strip CC40RE
Levelling bolts
There are four levelling bolts - two on each side that can be adjusted if required.
Access panel removal
The front access panel may be removed for ease of hooking up gas and electrical. Once complete ensure that the access panel is reinstalled prior to any finishing. The CC40LE/CC40RE has 4 screws to remove access cover. See locations in diagram to the right.
Leveling bolts
12 | City Series
Access panel screws
Page 13
installation
Clearances CC40LE/CC40RE
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
Note: CC40LE shown in illustration. Clearances will be the same for the CC40RE.
Clearance: single sided Dimension Measured From:
A: Mantel Height (min.)
B: Opening Height
C: From Floor
D: Sidewall (on one side)
E: Mantel Depth (Max.)
F: Alcove Depth
G: Convection Air Outlet
H: Convection Air Outlet Opening Offset
I: Chase Enclosure (Min.)
Hearth
** See mantel clearances chart in this manual.
F
I
A
** Top of Fireplace Opening
15-1/16" (382mm) Bottom/Top of Fireplace Opening
Min. 0" Bottom of Fireplace Opening
Min. 36" (914mm) Side of Fireplace Opening
** Front of Fireplace Opening
Min. 36" (914mm) Front of Fireplace Opening
* Top of Enclosure
0-3" (76mm) Max. offset from top of chase enclosure
63" (1600mm) From Base of Unit
0" No hearth required
H
G
E
D
Flue Clearances to Combustibles
Horizontal - Top 3" Horizontal - Side 2" Horizontal - Bottom 2" Vertical 2"
Passing through wall/ floor/ceiling - when
1-1/2"
firestop is used.
*A minimum of 120 square
inches of open area, not lower than 3" from top of enclosure, required for all installations
B
C
The HeatWave Duct Kit has differ­ent clearance and framing require­ments, check the HeatWave manual
F
for details.
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
D
CC40 UNIT
Top View
Alcove
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Fire hazard is an extreme risk
WARNING
City Series | 13
Page 14
installation
ts
top op
Clearances CC40LE/CC40RE
H
G
G
G
CC40LE shown
E
I
B
Low framing with ven
Low framing with vents in front/sides or top
G
H
CC40LE shown
14 | City Series
I
E
B
Floor to ceiling with
Floor to ceiling with top opening
Page 15
Clearances CC40LE/CC40RE
installation
CC40LE shown
Chase enclosed
H
H
G
G
I
E
B
Full framing with low vents in front or sides
H
H
G
G
I
E
B
CC40LE shown
City Series | 15
Full framing with vents in front or sides
Page 16
installation
20
Mantel Clearances CC40LE/CC40RE
Combustible mantel clearances from top of front facing are shown in the diagram on the right.
26
10
14
12" (305mm)
212 6 4810
Drywall, wood, wood panel, etc.
Combustible Material
Wood Stud
(On Edge)
Standof
f
9
0
To Bottom of Fireplace Lip
15-1/16”
2”
Top of Fireplace Opening
16 | City Series
Page 17
Framing Dimensions CC40LE (Left Corner)
NOTE: Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs.
installation
Framing Dimensions
A Framing Height 37-3/8” (949mm) B Framing Width 48-1/4" (1226mm) C Framing Depth 19" (483mm) D Unit Base to Top Enclosure (Min.) 63"(1600mm) G Vent Centerline Height 56-1/4" (1429mm)
NOTE: Unit cannot be load-bearing. All finishing materials must be supported by the framing.
Description CC40LE
Note: A combined minimum of 120 square inches of open area is required for the convection air outlet to cool the enclosure. En­sure clearances for Convection Air Outlets are met. See clearances CC40LE/CC40RE (single sided) in this manual as there are different methods as to how this can be achieved.
Note: This appliance must be in­stalled on a level and solid surface such as a plywood floor which must be the full width and depth of the appliance.
City Series | 17
Page 18
installation
Framing Dimensions CC40RE (Right corner)
NOTE: Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs.
Framing Dimensions
A Framing Height 37-3/8” (949mm) B Framing Width 48-1/4" (1226mm) C Framing Depth 19" (483mm) D Unit Base to Top Enclosure (Min.) 63"(1600mm) G Vent Centerline Height 56-1/4" (1429mm)
NOTE: Unit cannot be load-bearing. All finishing materials must be supported by the framing.
Description CC40RE
Note: A combined minimum of 120 square inches of open area is required for the convection air outlet to cool the enclosure. En­sure clearances for Convection Air Outlets are met. See clearances CC40RE (in this manual) as there are different meth­ods as to how this can be achieved.
Note: This appliance must be in­stalled on a level and solid surface such as a plywood floor which must be the full width and depth of the appliance.
18 | City Series
Page 19
installation
Wall Board/Drywall Installation CC40LE/CC40RE
WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified.
Finishing Instructions It is important to follow the framing and finishing instructions to ensure proper placement of fireplace into the surrounding framing/finishing materials. Wall board materials 1/2 in. thick are specified in this installation manual to properly align with the optional finishing methods offered with this appliance. The
CC40LE/CC40RE may be finished to the appliance opening with 1/2 inch thick drywall.
• Ensure that the back and side clearances are maintained.
WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Inadequate air space could cause overheating and fire.
DO NOT use screws more than 3/4 inch in length on the lower access cover panel. Longer screws may penetrate gas line or damage valve or electrical
components. Note: It is acceptable to use a high temperature silicone sealant to adhere drywall to lower access cover panel.
The appliance is designed to be used with 1/2 in. wall sheathing materials such as drywall, plywood, wood composites, or non-combustible materials. Thicker materials may be used. Refer to facing and finishing details in this manual.
Facing Material
• Facing and/or finishing materials must never overhang into the glass opening.
• Facing materials may be combustible or non-combustible
WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation.
PAINTING
If desired finishing includes a painted wall, 100% acrylic latex, oil-based or standard acrylic paints may be used. Follow paint manufacturer’s instructions for paint and primer application.
City Series | 19
Page 20
installation
Framing and Finishing Inset Installations CC40LE/CC40RE
1. Frame in the enclosure for the unit with framing material
Note: When constructing the framed opening ensure there is sufficient access to install the gas lines,electrical. Also the wiring harness must be wall mounted using the receptacle provided with the appliance. The wiring harness will be located on the right hand side of the appliance if facing the unit from the front. This must be done prior to any finishing.
2. For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.)
WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames etc. These are not product related issues.
3. The unit does not have to be completely enclosed in a chase. You must
maintain clearances from the vent to combustible materials: See "Clear­ances" section. Combustible materials can be laid against the side and back standoffs and the stove base.
4. Combustible material (drywall,wood,wood panels, etc.) may be brought
up to this appliance (top,bottom and sides)
5. Ensure that the material being used does not encroach anywhere in the
area of the glass. This would cause dangerous operating conditions.
6. This appliance comes with a 1/2" lip at top, sides and bottom to hide the
ends of the drywall. The 1/2" side and bottom, front and bottom side lips supplied with the appliance can alternatively be removed and replaced with J Style Trim or Metal Corner Bead purchased at your local hardware store to cover cut/exposed edges of the combustible facing material or any other finishing materials being used. Six (6) screws secure the bot­tom front lip. Two (2) secure the bottom side lips and 2 secure the side if deciding to remove these. These will be hidden so the outer panels (if installed) will need to be removed to access the screws. See outer panel removal in this manual.
7. This appliance can also be recessed (using combustible materials) with
a hearth in front of the appliance. This can also extend to the top. See below for details.
8. The wall behind the unit must be closed off.
**Combustible material may extend a minimum of 1/2" and to a maximum of 2-1/2" from the Front top and open side faces of the appliance. If 2-1/2" is insufficient non combustible material may be used instead of combustible to extend the finished material further out or alternatively be staggered if using combustible materials. See mantle clearance chart for details. The base and closed side have no limit when it comes to how far the combustible material may extend out from the appliance.
Note: an offset screwdriver is provided with the appliance for ease of removal/ installation.
20 | City Series
Page 21
Optional Framing Kit Installation CC40LE/CC40RE
CC40LE/CC40RE FRAMING KIT INSTALLATION
CITY SERIES
This framing kit is for the CC40LE/CC40RE. The parts are adaptable so the same kit can be installed on either the right or left side units.
NOTE: CC40RE SHOWN IN DIAGRAMS
Installation is the same for CC40LE, please note that images will appear fl ipped.
A 656-391
1. This framing kit requires the installation of two studs at locations shown below. Be sure to install studs and walls to enclose chase (see Unit Manual) prior to moving the unit into position.
installation
Shown for CC40RE
Stud
18"
B 656-392
2x C 656-393
D 656-396
E 656-394
F 656-398
G 656-397
H 656-395
J 656-399
K 656-400
Unit nailing strips are not required and can be recycled when using the framing kit.
Remove nailing fl anges
49 3/4"
Stud
2. Begin with the unit away from the wall. Install part A to the back of the unit using holes next to appropriate shape (diamond or square depending on which unit you have) using the diagrams below. Attach to the back of the unit using 2 screws in locations shown below.
CC40RE
Holes next to squares
Measured from wall to stud center
CC40LE
Holes next to diamonds
City Series | 21
A
NOTE: CC40LE use holes corresponding with diamond shape. CC40RE use holes corresponding with square shape.
Page 22
installation
CITY SERIES
3. Install B to the side of the unit, use the holes corresponding with the
appropriate shape (diamond or square depending on which unit you have) using the diagrams below. Attach B to the side of the unit and install 2 screws in locations shown below.
CC40RE
Holes next to squares
4. Install 2 x part C's onto par ts A & B respectively, identify the holes to
be used, attach to the unit with 2 screws each.
CC40LE
Holes next to diamonds
B
5. Slide unit against wall and line up part C's with studs in the wall. Attach both part C's to studs with at least two screws each; one at the top, and one near the unit (as seen below).
6. Install venting before proceeding further with framing kit construction. Refer to manual for venting instructions.
7. Identify D, attach to back corner C with 2 screws as shown below.
Studs
C
C
Part D Profi le
D
8. Identify E (see diagram below), attach E to front corner C with 2 screws as shown below.
Part E Profi le
E
22 | City Series
Page 23
installation
CITY SERIES
9. Identify F and attach to both E and D with 2 screws on each side.
F
10. Identify G and attach to back corner C and front corner F with 2
screws on each side.
12. Identify J (diagonal support) and attach to back corners C and front
corner F with 2 screws on each side.
13. Attach K (center support) to E and H with 2 screws each.
J
G
11. Identify H and attach to both front corners C and F with 2 screws on each side.
H
K
City Series | 23
Page 24
installation
BUILDING FRAMING OFF OF THE KIT
CITY SERIES
Building additional framing off of the framing kit
This framing kit is designed as a base in which to build additional framing. Studs can be affi xed to all outer faces using the holes identifi ed below. This will provide a stable surface that is fl ush with the front of the fi replace, ready for drywall or other fi nishing material.
The framing must be strong enough to support the weight of all fi nishing material and must not put any weight on the fi replace.
Holes for fi xing additional
framing to kit
Potential Wood Framing installs
24 | City Series
1/2” for drywall
Leave gap between framing and unit trim for nishing material
Page 25
Guidelines for installing a TV / ARTWORK above the unit
3.5”
MAX
Vertical 2x4
12.0” MIN
Horizontal 2x4
15.5” MIN
Airow
Zone
Do not
obstruct
installation
Note: All wiring should stay free and clear of the vent system to avoid damage due to heat. We recommend using a metal receptacle box and BX cable (120
volt wire protected by metal sheathing) if located directly in front of the vent
system. Ensure wiring is secured without any sag.
ZERO CLEARANCE TO TV: While most consumers prefer to centrally locate a wall mounted TV, the “Cool-Touch Wall Technology” means that the bottom edge of the TV can be installed flush with the bottom edge of the ventilated
fireplace chase opening.
The TV cannot be any lower than this finishing lip.
TV recessed into wall
The TV may be recessed into a wall as shown below. This can only recess into the chase opening a maximum of 3-1/2 inches and must be a minimum of 12 inches from the fireplace lip to the first stud. To achieve a maximum of 3-1/2" recess, the wall must be of a maximum of 2" as shown.
Airow
Zone
Do not
obstruct
15.5” MIN
Horizontal 2x4
12.0” MIN
Vertical 2x4
3.5”
MAX
Sample Install 1 Sample Install 2
3.5”
2.0”
12.0”
3.5”
MAX
20.0”
16.5”
3.5”
MAX
15.5”
2”
City Series | 25
Page 26
installation
Exterior Vent Termination Locations
1
Minimum Clearance Requirements
A
Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm)
B
Clearance to window or door that may be opened 12"(30cm) 9" (23cm)
C
Clearance to permanently closed window * *
D
Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) from the center line of the terminal (check with the local code)
E
Clearance to unventilated soffit 20"(51cm) 20"(51cm)
F
Clearance to outside corner: with AstroCap Termination Cap. 6"(15cm) 6"(15cm)
Clearance to outside corner: with all other approved Termination Caps. 14"(36cm) 14"(36cm)
G
Clearance to inside corner: with AstroCap Termination Cap 6"(15cm) 6"(12cm)
Clearance to inside corner: with all other approved Termination Caps. 12"(30cm)
H
Clearance to each side of center line extended above meter/regulator assembly 36"(90cm)
J
Clearance to service regulator vent outlet 36"(90cm) *
K
Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 12"(30cm) 9" (23cm)
L
Clearance to a mechanical air supply inlet #3' (91cm) above if within 10' (3m) horizontally.
M
Clearance above paved sidewalk or a paved driveway located on public property 84"(2.1m)
N
Clearance under veranda, porch, deck, or balcony 12"(30cm)
1
In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor
Clearance in accordance with local installation codes and the requirements of the gas supplier
*
a
3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b
3 feet (91cm) above - if within 10 feet (3m) horizontally
Canada
18"(46cm) 18"(46cm)
12"(30cm)
13"(33cm)
a
72"(1.8m) 36"(90cm)
USA
2
*
b
*
*
26 | City Series
Page 27
installation
4” X 6-5/8RIGID PIPE CROSS REFERENCE CHART
Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.
4” x 6-5/8” Rigid Pipe Cross Reference Chart
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
* Olympia Ventis DV applicable for the following units only: B36XTE, B36XTCE, B41XTE, B41XTCE, P36, P36E
Description
6” Pipe Length-Galvanized 46DVA-06 4DT-6 N/A 4D6 SV4L6 TC-4DL6 VDV-0406
6” Pipe Length-Black 46DVA-06B 4DT-6B N/A 4D6B SV4LB6 TC-4DL6B VDVB-0406
7” Pipe Length-Galvanized N/A N/A 4D7 N/A N/A N/A N/A
7” Pipe Length-Black N/A N/A 4D7B N/A N/A N/A N/A
9” Pipe Length-Galvanized 46DVA-09 4DT-9 N/A N/A N/A TC-4DL9 VDV-0409
9” Pipe Length-Black 46DVA-09B 4DT-9B N/A N/A N/A TC-4DL9B VDVB-0409
12” Pipe Length-Galvanized 46DVA-12 4DT-12 4D12 4D12 SV4L12 TC-4DL1 VDV-0412
12” Pipe Length-Black 46DVA-12B 4DT-12B 4D12B 4D12B SV4LB12 TC-4DL1B VDVB-0412
18” Pipe Length-Galvanized 46DVA-18 4DT-18 4D18 4D18 SV4LA TC-4DL18 VDV-0418
18” Pipe Length-Black 46DVA-18B 4DT-18B 4D18B 4D18B SV4LA TC-4DL18B VDVB-0418
24” Pipe Length-Galvanized 46DVA-24 4DT-24 4D24 4D24 SV4L24 TC-4DL2 VDV-0424
24” Pipe Length-Black 46DVA-24B 4DT-24B 4D24B 4D24B SV4LB24 TC-4DL2B VDVB-0424
36” Pipe Length-Galvanized 46DVA-36 4DT-36 4D36 4D36 SV4L36 TC-4DL3 VDV-0436
36” Pipe Length-Black 46DVA-36B 4DT-36B 4D36B 4D36B SV4LB36 TC-4DL3B VDVCB-0436
48” Pipe Length-Galvanized 46DVA-48 4DT-48 4D48 4D48 SV4L48 TC-4DL4 VDV-0448
48” Pipe Length-Black 46DVA-48B 4DT-48B 4D48B 4D48B SV4LB48 TC-4DL4B VDVB-0448
60” Pipe Length-Galvanized 46DVA-60 4DT-60 N/A N/A N/A N/A N/A
60” Pipe Length-Black 46DVA-60B 4DT-60B N/A N/A N/A N/A N/A
Adjustable Length 3”-10”-Galvanized N/A N/A N/A 4DAL N/A TC-4DLT N/A
Adjustable Length 3”-10”-Black N/A N/A N/A 4DALB N/A TC-4DLTB N/A
Adjustable Length 7”-Galvanized N/A N/A 4D7A N/A N/A N/A N/A
Adjustable Length 7”-Black N/A N/A 4D7AB N/A N/A N/A N/A
Extension Pipe 8-1/2”-Galvanized 46DVA-08A N/A N/A N/A N/A N/A N/A
Extension Pipe 8-1/2”-Black 46DVA-08AB N/A N/A N/A N/A N/A N/A
Adjustable Length 12”-Galvanized N/A N/A 4D12A N/A SV4LA12 TC-4dLSI N/A
Adjustable Length 12”-Black N/A N/A 4D12A N/A SV4LBA12 TC-4dLSIB N/A
Extension Pipe 16”-Galvanized 46DVA-16A N/A N/A N/A N/A N/A N/A
Extension Pipe 16”-Black 46DVA-16AB N/A N/A N/A N/A N/A N/A
Simpson
Direct Vent Pro
®
Selkirk
Direct Temp™
American Metal Products®
Amerivent Direct
Metal-Fab™
Sure Seal
Security
Secure- Vent®
ICC Excel
Direct
Olympia Ventis DV*
45º Elbow-Galvanized 46DVA-E45 4DT-EL45 4D45L N/A N/A TE-4DE45 VDV-EL0445
45º Elbow-Black 46DVA-E45B 4DT-EL45B 4DT-EL45B N/A N/A TE-4DE45B VDVB-EL0445
45º Elbow Swivel-Galvanized See 46DVA-E45 N/A N/A 4D45L SV4E45 N/A N/A
45º Elbow Swivel-Black See 46DVA-E45B N/A N/A 4D45LB SV4EB45 N/A N/A
90º Elbow-Galvanized 46DVA-E90 4DT-EL90S 4DT-EL90S N/A N/A TE-4DE90 VDV-EL0445
90º Elbow-Black 46DVA-E90B 4DT-EL90SB 4DT-EL90SB N/A SV4EBR90-1 TE-4DE90B VDVB-EL0445
90º Elbow, Swivel-Galvanized See 46DVA-E90 N/A N/A 4D90L SV4E90-1 N/A N/A
90º Elbow, Swivel-Black See 46DVA-E90B N/A N/A 4D90LB SV4EB90-1 N/A N/A
90º Starter Elbow, Swivel-Galvanized
Adaptor* N/A N/A N/A 4D90L N/A N/A VDV-UAA04
Ceiling Support N/A 4DT-CS 4DSP 4DFSP SV4SD TM4-RDS VDV-SCR04
Cathedral Support Box 46DVA-CS 4DT-CSS 4DRSB 4DRS SV4CSB TM4-SDS VDV-CSS04
Wall Support/Band 46DVA-WS 4DT-WS/B 4DWS 4DWS SV4BM TM-SWS VDV-WS04
Offset Support46
Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM N/A VDV-WPT04
Wal
l Thimble Support/Ceiling Support 46DVA-DC N/A N/A N/A SV4PF N/A N/A
Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF TM-4CS VDV-FS04
Tr im Plate-Black N/A 4DT-TP 4DFPB 4DcP SV4LA TM-4TP VDV-WTC04
N/A N/A N/A 4D90A N/A N/A N/A
DVA-ES - N/A
from FPI
4DT-OS N/A N/A SV4SU TM-SOS N/A
City Series | 27
Page 28
installation
Description
Attic Insulation Shield 12” 46DVA-IS
Attic Insulation Shield - Cold Climates 36”
Basic Horizontal Termination Kit (A) Disc. 4DT-HKA 4DHTK2 4DHTKA SV-SHK TM4-HTK VDV-KW04
Horizontal Termination Kit (B) 46DVA-KHA
Ver tical Termination Kit Disc. 4DT-VKC 4DHTK 4DHTK SV-FK N/A N/A
High Wind Vertical Cap 46DVA-VCH N/A N/A N/A N/A TM-4VT VDV-VCHW04
High Wind Horizontal Cap 46DVA-HC N/A N/A N/A N/A TM-4DHT N/A
Horizontal Square Termination Cap 46DVA-HC 4DT-HHC 4DHC 4DHT SV4CHC-1 TM-4HT VDV-HC04
Ver tical Termination Cap 46DVA-VC 4DT-HVC 4DVC 4DVT SV4CGV-1 N/A N/A
Storm Collar 46DVA-08A 4DT-SC 4DSC 4DSC SV4FC TM-SC VDV-SC04
Adjustable Flashing 0/12-6/12 46DVA-F6 4DT-ST14 4D12S 4DST14 SV4STC14 TF-4FAVDV-F0406
Adjustable Flashing 6/12-12/12 46DVA-F12 4DT-ST36 4D36S 4DST36 SV4STC36 TF-4FB VDV-SSO
Vinyl Siding Standoff 46DVA-VSS 4DT-VS N/A 4DVS SV4VS TM-VSS N/A
Vinyl Siding Shield Plate N/A 4DT-VSP N/A N/A SV4VS N/A N/A
Snorkel Termination 14” 46DVA-SNK14 N/A N/A N/A N/A TM-4ST14 N/A
Snorkel Termination 36” N/A N/A N/A N/A N/A TM-4ST36 N/A
Restrictor Disk N/A N/A N/A N/A N/A TM-4DS N/A
Extended Vertical Te rmination Cap N/A N/A N/A N/A N/A N/A N/A
Chimney Conversion Kit A (USA only) 46DVA-KCA N/A N/A N/A N/A TM-4CA6 N/A
Chimney Conversion Kit B (USA only) 46DVA-KCB N/A N/A N/A N/A TM-4CA7 N/A
Chimney Conversion Kit C (USA only)
Wall Firestop 46DVA-WFS N/A N/A N/A N/A TM-4TR VDV-FS04
Colinear Flex Connectors 46DVA-ADF N/A N/A N/A N/A N/A N/A
Simpson
Direct Vent Pro
N/A@ FPI
N/A N/A 4DAIS12 N/A N/A TM-4AS N/A
(Changed Components)
46DVA-KCC N/A N/A N/A N/A TM-4CA8 N/A
Selkirk
®
Direct Temp™
N/A 4DAIS12 N/A SV4RSA N/A VDV-AIS04
4DT-HKB 4DHTK1 4DHTKB SV-HK TM4-HTK VDV-K04
American Metal Products®
Amerivent Direct
Metal-Fab™
Sure Seal
Security
Secure- Vent®
ICC Excel
Direct
Olympia Ventis DV*
* Olympia Ventis DV applicable for the following units only: B36XTE, B36XTCE, B41XTE, B41XTCE, P36, P36E
FPI
946-506/P Vent Guard (Optional) for AstroCap 946-205 Vinyl Siding Shield for Riser Vent Terminal
510-994 Rigid Pipe Adaptor (Must use with all rigid piping) 946-208/P Vent Guard (Optional) for Riser Vent Terminal
640-530/P Riser Vent Terminal 946-523/P AstroCap Horizontal Cap
946-206 Vinyl Siding Standoff for AstroCap
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
0” (0mm) 4-7/8” (124mm) 13-7/8” (340mm) Simpson Direct Vent Pro: www.duravent.com
6” (152mm) 8” (203mm) 16-1/2” (419mm) Selkirk Direct-Temp: www.selkirkcorp.com
9” (229mm) 10-1/8” (257mm) 18-5/8” (473mm) American Metal Products: www.americanmetalproducts.com
12” (305mm) 12-1/4” (311mm) 20-3/4” (527mm) Metal-Fab Sure Seal: www.mtlfab.com
24” (610mm) 20-5/8” (524mm) 29-1/8” (740mm) Security Secure Vent: www.securitychimneys.com
36” (914mm) 29” (737mm) 37-1/2” (953mm) Industrial Chimney Company: www.icc-rsf.com
48” (1219mm) 37-7/16” (951mm) 45-15/16” (1167mm)
Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
4” x 6-5/8” Venting For specifi c instructions on venting components - visit the
Run (X) Rise (Y)
manufacturers website listed below.
28 | City Series
Page 29
Wall Mount On / Off Switch and Battery Holder Installation
Required for all installations
IMPORTANT INSTALLATION NOTE:
The Battery Holder must be placed inside the supplied (Low Voltage) junction type wall box and installed into
the wall only.
DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE SWITCH MUST BE ACCESSIBLE
Battery Holder Installation
1. Install the low voltage junction box to the framing, at desired location within 10-1/2 ft. from replace.
2. Feed the 6 pin connector wiring harness through the opening at back of junction box. The wiring harness
is located near the gas valve and will need to be routed to the exterior of the replace from either the left
or right hand side prior to nishing.
3. Connect the 6 pin connector to the back of the Battery Holder.
4. Install the Battery Holder in the Low Voltage Junction box.
5. Install batteries only if 120 volt power will not be used. Batteries are only used if power is lost within the
home and serve as a secondary power source. Insert the 4 AA type batteries in the battery compartment
with the correct polarity.
6. Place the slider into the cover plate.
7. Put the Battery Holder switch in the “OFF” position, to allow correct lineup for slider switch.
8. Make sure the Battery Holder and cover plate words “ON” and “UP” are on the same side.
9. Align the slider with the switch on the Battery Holder and couple the switch into the slider.
10. Align the screw holes.
11. Using the two (2) screws provided secure the cover plate to the Battery Holder.
12. For coding instructions, see full details in this manual.
installation
Low Voltage Junction Box
Proame Battery Holder
Slider Switch
J-Box
Battery Holder
Wall Plate
Diagram 1
City Series | 29
Page 30
installation
Vent Restrictor Position
Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation.
The Vent Restrictor plate is packed in the instruction manual package.
To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;
1. Remove the safety glass and firebox glass - see instructions in this manual.
2. Remove the screws that hold the vent restrictor plate in place (see Diagram 1)
3. Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.
4. Once the vent restrictor plate is in the required position, secure with screws.
Vent restrictor positions:
Set 0 (Full open) Factory set
Set 1 (Vent restrictor at 2”)
Set 2 (Vent restrictor at 1.75”)
Screw locations
Vent restrictor location - inside top of rebox
Diagram 1
30 | City Series
Set 3 (Vent restrictor at 1.5”)
Page 31
installation
Horizontal Terminations
Flex Vent 4" x 6-7/8"
These venting systems, in combination with the CC40LE/CC40RE Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent
Termination Locations" section.
Regency® Direct Vent (Flex) System Termination Kits includes all the parts needed to install the CC40LE/CC40RE using a flexible vent.
FPI Kit # Length Contains:
#946-513 2 Feet 1. 6-7/8” flexible outer liner (Kit length)
#946-515 4 Feet
#946-516 10 Feet
Notes:
1. Liner sections should be continuous without any joints or seams.
2. Only Flex pipe purchased from Regency® may be used for Flex installations
3. Horizontal vent must be supported every 3 feet.
4. Regency® Direct Vent System (Flex) is only approved for horizontal terminations.
5. Flex system can only be used up to a maximum continuous vent length of up to 10 feet. If longer runs are required, rigid pipe must be used.
2. 4” flexible inner liner (Kit length)
3. spring spacers
4. thimble
5. AstroCap termination cap
6. screws
7. tube of Mill Pac
8. plated screws
9. S.S. screws #8 x 1-1/2” drill point
Vent Guard - if required*
(Part #946-506/P)
City Series | 31
Page 32
installation
Venting Introduction
The CC40LE/CC40RE uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
Venting Arrangement for Horizontal Terminations
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o (two 45o elbows equal one 90o elbow).
Note: When using rigid vent pie systems, the rigid pipe adapter (Part# 510-994) must be used in all applications.
56-1/4” (1429mm)
VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 0.
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required.
NOTE: A minimum of 1' (305mm) vertical off the top of the unit is required before any horizontal runs can start.
Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous
vent length of up to 10 feet. If longer runs are required, rigid pipe must be used.
• Maintain clearances to combustibles as listed in "Clearances" section
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
• A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
• Flex system can only be used up to 10 feet - otherwise rigid venting must be used.
32 | City Series
Page 33
Horizontal Terminations
Rigid Pipe 4" x 6-5/8"
The minimum components required for a basic horizontal termination are:
1 Horizontal Termination Cap 1 Rigid Pipe Adaptor (510-994) 1 Wall Thimble 1 Length of pipe to suit wall thickness (see chart)
Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.
installation
Horizontal
Termination Cap
Vinyl Siding
Standoff (Optional)
Flat Wall Installation
Wall Thickness
(inches)
4" - 5-1/2" 6"
7" - 8-1/2" 9"
10" - 11-1/2" 12"
9" - 14-1/2' 11" - 14-5/8" Adj. Pipe
15" - 23-1/2" 17" - 24" Adj. Pipe
WARNING:
Do not combine venting components from different venting systems.
Use of the the AstroCapTM and FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct Venting, ICC Excel Direct and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.
Vent Length Required
(inches)
Adj.Pipe Length
o
90 Elbow
Pipe Length
Rigid Pipe Adapter
Wall Thimble
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap can Metal Products Ameri Vent Direct Vent, Security Secure Vent®, ICC Excel, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
TM
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent, Ameri-
City Series | 33
Page 34
installation
Horizontal Terminations
Rigid Pipe 4" x 6-5/8"
The diagrams below show examples of horizontal termination arrangements using one, two, or three 90o elbows (two 45o elbows equal one 90o elbow)
1. A maximum of three 90o elbows are permitted.
2. Minimum distance between elbows is 1 ft. (305mm).
• Maintain clearances to combustibles as listed in the "Clearances" section.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
• Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems.
• A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
• Flex system can only be used up to 10 feet - otherwise rigid venting must be used.
Horizontal Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option V H + H1
A) 1' Min. 2' Max.
B) 2' Min. 4' Max.
C) 3' Min. 5' Max.
D) 4' Min. 6' Max.
E) 5' Min. 7' Max.
F) 6' Min. 8' Max.
Restrictor Set 0 - Factory Setting
H1
With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.
Please note minimum 1 foot between 90o elbows is required.
H
V
Horizontal Venting with Three (3) 90o Elbows
One 90o elbow = Two 45o elbows.
Option V H V + V1 H + H1
A) 1' Min. 1' Max. 2' Min. 2' Max.
B) 1' Min. 2' Max. 3' Min. 3' Max.
C) 2' Min. 2' Max. 5' Min. 4' Max.
D) 3' Min. 2' Max. 7' Min. 5' Max.
E) 4' Min. 3 Max. 9' Min. 6' Max.
F) 5' Min. 4' Max. 10' Min. 7' Max.
G) 6' Min. 5' Max. 11' Min. 8' Max.
H) 7' Min. 6' Max. 12' Min. 9' Max.
Restrictor Set 0 - Factory Setting
With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.
Please note min. 1 foot between 90o elbows is required.
34 | City Series
Page 35
Vertical terminations
Rigid Pipe 4" x 6-5/8"
The minimum components required for a basic vertical termination are:
1 Vertical Termination Cap 1 Rigid Pipe Adaptor (510-994) 1 Ceiling Firestop 1 Flashing 1 Storm Collar 1 Length of pipe to suit wall thickness (see chart)
Galvanized pipe is desirable above the roofline due to its higher
corrosion resistance. Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in diagram 2 or local codes. Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.
installation
Roof Pitch Minimum Vent
Height
Feet Meters
flat to 7/12 2 0.61
over 7/12 to 8/12 2 0.61
over 8/12 to 9/12 2 0.61
over 9/12 to 10/12 2.5 0.76
over 10/12 to 11/12 3.25 0.99
over 11/12 to 12/12 4 1.22
over 12/12 to 14/12 5 1.52
over 14/12 to 16/12 6 1.83
over 16/12 to 18/12 7 2.13
over 18/12 to 20/12 7.5 2.29
over 20/12 to 21/12 8 2.44
Diagram 2
WARNING:
Do not combine venting components from different venting systems.
Use of the the AstroCapTM and FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct Venting, ICC Excel Direct and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.
Diagram 1
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap can Metal Products Ameri Vent Direct Vent, Security Secure Vent®, ICC Excel, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
TM
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent, Ameri-
City Series | 35
Page 36
installation
0
Venting Arrangement for Vertical Terminations
Vertical Venting with straight Vertical venting and or with a max. of two (2) 90o Elbows (1 - 90
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with Rigid Pipe Venting Systems.
o
Two 45
elbows equal to one 90o elbow.
• Vent must be supported at offsets.
• Minimum distance between elbows is 1 ft. (305mm).
• Maintain clearances to combustibles as listed in the "Clearances" section.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
• Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems.
• Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 through to Set 3 if required.
2
4
0
40
38
36
34
32
30
28
26
Vent Restrictor on Set 3
6
Horizontal (Feet)
8
10 12 16
Maximum: 37 ft. (11.2m)
o =
2 - 45o)
14
18
2
24
22
20
18
Vertical Height (Feet)
16
14
12
10
8
6
4
Vent Restrictor on Set 2
Vent Restrictor on Set 1
Minimum
8’6” (2.6m)
Maximum: 27 ft. (8.2m)
36 | City Series
2
0
Minimum length of pipe
between elbows 12” (305mm)
(1429mm)
Min. 56-1/4”
Page 37
Vertical Terminations Rigid Pipe 4" x 6-5/8"
installation
• Two 45
• Vent must be supported at offsets.
• Minimum distance between elbows is 1 ft. (305mm).
• Maintain clearances to combustibles as listed in the "Clearances" section.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
• Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems.
o
elbows equal to one 90o elbow. Maximum of six 45o elbows allowed.
Vertical Venting with Three (3) 90o Elbows
One 90o elbow = Two 45o elbows.
Option V H + H1 V + V1
A) 1' Min. 2' Max 3' Min.
B) 2' Min. 3' Max 4' Min.
C) 3' Min. 4' Max 6' Min.
D) 4' Min. 5' Max 7' Min.
E) 5' Min. 6' Max 8' Min.
F) 6' Min. 7' Max 9' Min.
G) 7' Min. 8' Max 10' Min.
Lengths do not include elbow indicated
With these options, max. total pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizontal.
Please note min. 1 foot between 90o elbows is required.
V1
H1
H
V
City Series | 37
Page 38
installation
56-1/4" (1429mm)
Min. height
Unit Installation with Horizontal Termination
4" x 6-5/8" venting
(Rigid Vent Systems)
Minimum Vent Clearances to Combustibles
Clearances noted below must be maintained; except when passing through a wall, ceiling or at the termination
where the use of a restop or wall thimble reduces
clearance to 1-1/2" (38mm).
Horizontal Top 3" (76mm)
Horizontal Side 2 " (51mm)
Horizontal Bottom 2" (51mm)
Vertical Vent 2" (51mm)
Below are the recommended framing dimensions (inside measurements) for the 4" x 6-5/8" rigid vent terminations - for use with a firestop or wall thimble.
Recommended Framed Opening
Size
Vent Size Framing Size
4" x 6 - 5/8" 10" x 10"
Install the vent system according to the manufacturer's instructions included with the components.
1. Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.
2. Direct Vent pipe and fittings are designed with special twist-lock connections to connect the venting system to the appliance flue outlet. A twist-lock appliance adaptor is required.
3. In conjunction with the Approved Vent system, install the adaptor after the unit is set in its desired location. Put a bead of Mill-Pac inside the outer section of the adapter and a bead of Mill-Pac on the inner collar. Slip the adapter over the existing inner and outer flue collar. Fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier).
4. Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips.
5. Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock for a solid connection.
Note: For best results and optimum
performance with each approved venting system, it is highly recommended to apply Mill-Pac sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty.
Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose.
6. Mark the wall for a square hole.-see chart to left for size. The center of the square hole should line up with the center-line of the horizontal pipe. Cut and frame the square hole in the exterior wall where the vent will be terminated. See diagram 2 for center line requirements.
If the wall being penetrated is constructed of
non-combustible material, i.e. masonry block or concrete, an 8" (203mm) diameter hole is acceptable.
Note:
a) The horizontal run of vent must be level, or
have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.
b) The location of the horizontal vent
termination on an exterior wall must meet all local and national building codes.
center
of hole
C
L
C
L
(Rigid)
Diagram 2
7. Ensure that the pipe clearances to combustible materials are maintained (Diagram 3). Install the termination cap.
Note: If installing termination on a vinyl
siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.
Diagram 3
The four wood screws provided should be
replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
8. Before connecting the horizontal run of vent pipe to the vent termination, slide the Wall Thimble over the vent pipe. The wall thimble is required for all horizontal terminations.
9. Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap.
10. Install wall thimble in the center of the framed hole and attach with wood screws (Diagram 4).
Diagram 4
Diagram 1
38 | City Series
Page 39
installation
Furstrp.eps
see also c34020a.eps
(294mm)
56-1/4”
Unit Installation with Horizontal Termination
4" X 6-5/8" VENTING
(Flex Vent Systems)
Minimum Vent Clearances to Combustibles
Clearances noted below must be maintained; except when passing through a wall, ceiling or at the termination
where the use of a restop or wall thimble reduces
clearance to 1" (25mm).
Horizontal Top 3" (76mm)
Horizontal Side 2 " (51mm)
Horizontal Bottom 2" (51mm)
Vertical Vent 2" (51mm)
Below are the recommended framing dimensions (inside measurements) for the 4" x 6-5/8" rigid
vent terminations - for use with a restop or wall
thimble.
Recommended Framed Opening
Vent Size Framing Size
4" x 6 - 5/8" 10" x 10"
1. Locate the unit in the framing, rough in the gas (preferably on the right side of the unit). Locate the centerline of the termination and mark wall accordingly. Cut an square hole in the wall - see chart (inside dimension).
Note: If installing termination on a siding covered
wall, a vinyl siding standoff or vinyl furring strips must be used to ensure that the termination is not recessed into the siding.
2. Level the fireplace and fasten it to the framing using nails or screws through the nailing strips.
3. Assemble the vent assembly by applying Mill Pac to the inner flue collar of the termination and slipping the inner flex liner over it at least 1-3/8" (35mm). Fasten with the 3 screws (drilling pilot holes will make this easier). Apply Mill-Pac to the outer flex pipe and slip it over the outer flue collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 screws.
Size
Outside Wall
Furring
Strips
NOTE: Horizontal sections must be sup-
ported at intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags in the liner).
4. Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls.
5. Slip the assembled liner and termination as­sembly through the thimble making sure the termination cap faces up (there are markings on the cap indicating which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws.
6. Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fire­place. (You may wish to cut the liner shorter to make it more workable.) Do not bend liner more than 90o. The liners must slip over the collars a minimum of 1-3/8".
7. Apply Mill Pac over the fireplace inner flue collar and slip the inner flex liner down over it and attach with 3 supplied screws.
8. Do the same with the outer flue collar and outer flex liner.
9. Apply a bead of silicone between the thimble and termination and around the outer edge of the terminal at the wall in order to keep the water out.
IMPORTANT: Do not locate termination hood
where excessive snow or ice buildup may
occur. Be sure to check vent termination area after snow falls, and clear to prevent
accidental blockage of venting system. When using snow blowers, make sure snow is not
directed towards vent termination area.
Screws
(3 per
connection)
4" (102mm) dia. flue pipe
with spring spacer
6-7/8" (173mm) dia. air intake
Wall Thimble 2 pieces
(10" (254mm)
Outer Diameter)
ASTROCAP DIMENSIONS (946-523/P)
(294mm)
11”
2” x 4” or 2” x 6”
Termination
Cap
Screws
(4 per
connection)
11”
of hole
C
L
(1429mm)
Min.
City Series | 39
Page 40
installation
56-1/4” (1429mm)
Dura-Vent Horizontal terminations
Install the vent system according to the manufacturer's instructions included with the components.
1) Set the unit in its desired location. Check to
determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.
2) Direct Vent pipe and fittings are designed with special twist-lock connections to connect the venting system to the appliance flue outlet. A twist-lock appliance adaptor is an available option that must be used in conjunction with the Simpson Dura-Vent Direct Vent system.
3) Put a bead of Mill-Pac inside the outer section of the adaptor and on the inner collar. Slip the adapter over the existing inner and outer flue collar and fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier). Level the fireplace and fasten it to the framing using nails or screws through the nailing strips.
4) Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock for a solid connection.
Note: a) Twist-lock procedure: Four indenta-
tions, located on the female ends of pipes and fittings, are designed to slide straight onto the male ends of adjacent pipes and fittings, by orienting the four pipe indentations so they match and slide in to the four entry slots on the male ends, Diagram 1. Push the pipe sections completely together, then twist-lock one section clockwise approximately one­quarter turn, until the two sections are fully locked. The female locking lugs will not be visible from the outside, on the Black Pipe or fittings. They may be located by examining the inside of the female ends.
b) Horizontal runs of vent must be supported
every three feet. Wall straps are available for this purpose.
5) Mark the wall for a 10" x 10" square hole. The center of the square hole should line up with the centerline of the horizontal pipe. Cut and frame the 10 inch square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of non­combustible material, i.e. masonry block or concrete, a 7"(178mm) dia. (7-1/2"(191mm) dia. for flex) hole is acceptable.
Diagram 2
Note:
a) The horizontal run of vent must be level, or
have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.
b) The location of the horizontal vent
termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. For External Vent Terminal Locations, see the "Exterior Vent Termination Locations" section.
c) Snorkel Terminations: For installations requiring a vertical rise on
the exterior of the building, 14-inch and 36­inch tall Snorkel Terminations are available, as well as the standard Riser Vent. Follow the same installation procedures as used for standard Horizontal Termination. NEVER
install the snorkel upside down.
Note: Riser Vent is only for use in above grade terminations.
Diagram 3a
*Diagrams 3 & 4: As specified in CGA B149 Installation Code. Local codes or regulations may require different clearances.
Below Grade Installation
If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Diagram 4. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.
Diagram 1
NOTE: For best results and optimum perfor­mance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty.
40 | City Series
Diagram 4
NOTE: For Snorkel terminations in
ABOVE grade installations, follow national or local code requirements.
6) The arrow on the vent cap should be pointing up. Insure that the 1-1/2" clearances to
combustible materials are maintained (Diagram
4). Install the termination cap.
The four wood screws provided should be
replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
Page 41
installation
Dura-Vent Vertical Termination
4" x 6-5/8" venting
(Rigid Vent Systems)
1. Maintain the 1-1/2" clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. Check "Venting" Sections for the maximum vertical rise of the venting system and the maximum horizontal offset limitations.
2. Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof.
3. A firestop spacer must be installed in the floor or ceiling of every level. To install the Firestop spacer in a flat ceiling or wall, cut a 10 inch square hole. Frame the hole as shown in Diagram 2 and install the firestop.
Note: All vertical terminations are vented using 4" x 6-5/8" venting and rigid pipe adaptor #510-994.
Diagram 1
4. Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow con­nections are in the fully twist-locked position and sealed.
NOTE: For best results and optimum perfor­mance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty.
5. Cut a hole in the roof centered on the small
drilled hole placed in the roof in Step 2. The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles of 1-1/2". Slip the flashing under the shingles (shingles should overlap half the flashing) as per Diagram 3.
Diagram 3
Diagram 3: The upper half of the ashing is installed under the roong material and not nailed down until the chimney is installed. This allows for small
adjustments.
Diagram 4
Roof Pitch Minimum Vent Height
Feet Meters
flat to 7/12 2 0.61
over 7/12 to 8/12 2 0.61
over 8/12 to 9/12 2 0.61
over 9/12 to 10/12 2.5 0.76
over 10/12 to 11/12 3.25 0.99
over 11/12 to 12/12 4 1.22
over 12/12 to 14/12 5 1.52
over 14/12 to 16/12 6 1.83
over 16/12 to 18/12 7 2.13
over 18/12 to 20/12 7.5 2.29
over 20/12 to 21/12 8 2.44
7. Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails, slide storm collar over the pipe section and seal with a mastic.
8. Install the vertical termination cap by twist­locking it.
Note: Any closets or storage spaces, which
the vent passes through must be
enclosed.
Diagram 2
City Series | 41
6. Continue to assemble pipe lengths.
Note: If an offset is necessary in the attic
to avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose.
Galvanized pipe is desirable above the roofline
due to its higher corrosion resistance. Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in Dia. 4 or local codes. Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.
Page 42
installation
VERTICAL TERMINATION
4" X 6-7/8" VENTING - VERTICAL FLEX VENT KIT (946-755)
Flashing
Termination Cap
Storm Collar
Roof support
Vertical Termination 4" x 6-7/8" venting
1. Maintain the 1-½” clearance (air space) to combustibles when passing
through ceilings, walls, fl oors, enclosures, attic rafters or other nearby
combustibles. Do not pack air spaces with insulation. Check Venting sections for the maximum vertical rise of the venting system and the
maximum horizontal off set limitations.
Ensure that you maintain clearances around enclosures, walls, below
or above fl oors, fl oor joists, etc. Each appliance has diff erent clearance requirements (top,sides,bottom). See speci c appliance manual for details.
2. Set the appliance in its desired position. Drop a plumb bob down from
the ceiling/fl oor joist to the position of the appliance fl ue exit and mark
the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next drop a plumb bob from the roof to the hole previously drilled at the ceiling level and mark the spot where the vent will penetrate the roof.
3. Cut a hole in the roof centered on the small hole placed in the roof in the previous steps. The hole should be a minimum of 10-¼ inches. The hole may be round and or square.
4. Slip the fl ashing under the shingles and line up fl ashing so it is centered
to the hole (shingles should overlap half of the fl ashing) as per Diagram
1.
Diagram 1: The upper half of the  ashing is
installed under the roo ng material and not
nailed down until the chimney is installed.
This allows for small adjustments.
Diagram 1
5. A ceiling  restop/ restop spacer must be installed when passing through each fl oor or ceiling level. To install the ceiling  restop/ restop spacer in a fl at ceiling or fl oor joist cut a 10- ¼ inch square hole. Frame the hole as show in Diagram 1 and install the ceiling  restop. Slide the top attic insulation spacer onto the top of the attic insulation shield/ restop - See
Diagram 1a. Secure with 4 screws/nails. If more than one is required, these can be purchased separately.
11. Secure inner fl ex pipe to pipe adaptor by using Mill-Pac over the adaptor.
Slide the inner pipe over adaptor and secure with 3 screws.
12. Repeat Step 11 to secure outer fl ex.
13. Slide the  nished length up towards the fl ashing ensuring the length of
pipe is a minimum of 2 feet measured from the top of the roof. Level the chimney and secure using the roof support provided with kit to bottom side of the roof as shown using a minimum of 2 screws per side- see Diagram 3b. See Diagram 4 for roof pitch and height requirements. See
Diagram 3a for securing method if 2 ft. is insuffi cient and additional lengths
are required, this may be purchased separately. See Simpson Duravent components list in the instruction manual for part numbers.
Termination Cap
Storm Collar
Flashing
Roof Support / Brace
Ceiling Firestop
Ceiling Firestop
Flex Pipe
Support to prevent sagging
Elbow Support
Termination Cap
Storm Collar
Flashing
Roof Support
Ceiling Firestop
Enclosure
Ceiling Firestop
Flex Pipe
Diagram 3 Diagram 3a
Termination Cap
Storm Collar
Flashing
Note: The ceiling  restop/ restop spacer may be cut down to size if this
shield is too high for the application.
-1/4
60
Diagram 2
Ceiling firestop
Firestop spacer to prevent
debris from falling into the
ceiling  restop
Ceiling firestop
Enclosure
Diagram 2a
Ceiling firestop
6. Determine the overall height of the chimney from the top of the appliance
to the underside of the fl ashing. If required cut the fl exible inner and outer
pipe to the desired length up to a maximum of 20 feet.
7. Put a bead of Mill-Pac around the 4 inch collar on the appliance and slide
the inner fl ex pipe over the inner collar of the appliance and secure with
a minimum of 3 screws.
8. Install 4 inch spacers around 4 inch fl ex.
9. Repeat Step 7 to install the outer pipe to the outer collar of the appliance
Note: If an off set is necessary in the attic or fl oor joists it is important to
support the vent pipe every 3 feet to avoid excessive stress and sagging of the vent pipe. Wall straps are provided (3 in total) for this purpose. All round/plumbers strapping may also be used if further supports are required.
10. Attach the rigid pipe section to the adaptor by using Mill-Pac on the inner/ outer pipe. Use 3 screws to secure outer pipe.
Roof support
Diagram 3b
Diagram 4
Roof Pitch Minimum Vent Height
Feet Meters
fl at to 7/12 2 0.61
over 7/12 to 8/12 2 0.61
over 8/12 to 9/12 2 0.61
over 9/12 to 10/12 2.5 0.76
over 10/12 to 11/12 3.25 0.99
over 11/12 to 12/12 4 1.22
over 12/12 to 14/12 5 1.52
over 14/12 to 16/12 6 1.83
over 16/12 to 18/12 7 2.13
over 18/12 to 20/12 7.5 2.29
over 20/12 to 21/12 8 2.44
14. Put a bead of caulking on the exterior between the outer pipe and fl ashing
to prevent water from penetrating the chimney system.
15. Slide storm collar over pipe length until it reaches the fl ashing.
16. Install termination cap by twist locking it.
17. Secure the fl ashing to the roof using screws
Note: Any closets or storage spaces which the vent passes through must
be enclosed.
42 | City Series
Page 43
VERTICAL FLUE EXTENSION KIT (PART # 946-756)
919-698
08.10.16
60
-1/4
Ceiling firestop
Diagram 1
Diagram 1a
Diagram 1a
Enclosure
Ceiling firestop
Flashing
Termination Cap
Storm Collar
Roof support
Ceiling firestop
Flashing
Termination Cap
Storm Collar
Roof support
Firestop spacer to prevent
debris from falling into the ceiling
restop
A ceiling restop/restop spacer must be installed when passing through each oor or ceiling level. To install the ceiling restop/restop spacer in a at ceiling or oor joist cut a 10- ¼ inch square hole. Frame the hole as show in Diagram 1 and install the ceiling restop. Slide the top attic insula- tion spacer onto the top of the attic insulation shield/restop - See Diagram 1a. Secure with 4 screws/nails. If more than one is required, these can be purchased separately.
Note: The ceiling restop/restop spacer may be cut down to size if this shield
is too high for the application
CEILING FIRESTOP/FIRESTOP SPACER ( PART # 946-757)
The ceiling restop/restop spacer may be cut down to size if this shield
CEILING FIRESTOP/FIRESTOP SPACER ( PART # 946-757)
1
Vertical flue extension kit (part #946-756)
20 foot Flex pipe Extension
(Used in conjunction with the 946-755 Vertical Flex kit and 948-367/P ex to ex adaptor).
1. Stretch out both inner 4" (100 mm) and outer 6 7/8" (175mm) pipe up to a maximum of 20 feet.
Note :The inner and outer pipes may be cut if only a short length is required.
2. Install spring spacers around 4" (100 mm) inner pipe as shown.
Slide outer ex pipe over and all the way down the 4" pipe.
3. Apply a bead of Mill Pac around the perimeter of the 4" (100mm) inner collar of the ex adapter and slip the 4" (100mm) inner ex pipe from the Vertical termination kit over the ex adapter ensuring that the inner ex pipe overlaps the collar by at least 1-3/8" (35mm). Fasten with 3 screws.
4. Apply a bead of Mill Pac around the perimeter of the 6-7/8" (175mm) outer collar of the ue adapter and slip it over the 6-7/8" (175 mm) outer ex pipe from the vertical termination kit ensuring that the outer ex pipe overlaps the collar by at least 1-3/8" (35mm). Fasten with the 3 screws.
5. Repeat steps to secure the other end of the ex adapter using the ex kit.
6. See Vertical Vent installation instructions for installation of the complete vent system.
4" (100mm) inner pipe
6-7/8" (175mm)
outer ex pipe
20ft
installation
20ft.
10 spring spacers
ex adaptor
3 wall straps
Note: If an o󰀨set is necessary in the attic or oor joists it is important to sup­port the vent pipe every 3 feet to avoid excessive stress and sagging of the vent pipe. Wall straps are provided (3 in total) for this purpose.
All round/plumbers strapping may also be used if further supports are required.
Ceiling Firestop / firestop spacer (part #946-757)
A ceiling restop/restop spacer must be installed when passing through each oor or ceiling level. To install the ceiling restop/restop spacer in a at ceiling or oor joist cut a 10- ¼ inch square hole. Frame the hole as show in Diagram 1 and install the ceiling restop. Slide the top attic insula­tion spacer onto the top of the attic insulation shield/restop - See Diagram 1a. Secure with 4 screws/nails. If more than one is required, these can be purchased separately.
Note:
is too high for the application
-1/4
60
Ceiling firestop
Firestop spacer to prevent
Diagram 1
debris from falling into the ceiling
restop
Enclosure
City Series | 43
Ceiling firestop
Ceiling firestop
Page 44
installation
1
2
3
4
6
5
7
CC40LE/CC40RE NG SYSTEM DATA
Min. Supply Pressure
Manifold Pressure 3.8" WC (0.94 kpa)
Orice Size #42 DMS
Maximum Input 28,500 Btu/h
Minimum Input 15,500 Btu/h
5" WC (1.25 kpa)
(8.33 kW)
(4.54 KW)
CC40LE/CC40RE LP SYSTEM DATA
Min. Supply Pressure 11" WC (2.73 kpa)
Manifold Pressure 10.5" WC (2.62 kpa)
Orice Size #53 DMS
Maximum Input 28,500 Btu/h
Minimum Input 15,500 Btu/h
(8.35 kW)
(4.54 KW)
High Elevation
This unit is approved for altitude 0 to 4500 ft. (CAN1
2.17-M91).
Gas Line Installation
Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.
For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.
When using copper or flex connectors use only approved fittings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and flex connectors are usually considered to meet this requirement.
NOTE: A shutoff / dante valve should be sup­plied in or near the unit (or as per local codes) for ease of servicing this appliance.
IMPORTANT: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing.
Pilot Adjustment
Periodically check the pilot flames. Correct flame pattern has two strong blue flames: 1 flowing around the flame sensor and 1 flowing across the burner (it does not have to be touching the burner).
Burner
Flame Sensor
Pilot
Ignitor
Note: If you have an incorrect flame
pattern, contact your Regency® dealer for further instructions.
Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear burner or flame sensor.
Gas Pipe Pressure Testing
The appliance must be isolated from the gas sup­ply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.
The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1 Make sure the unit is in the "OFF" position.
2. Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a
1/8" wide flat screwdriver.
3. Attach manometer to "IN" and/or "OUT" pres­sure tap(s) using a 5/16" ID hose.
4. Turn the unit on with the remote or wall switch
5. The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.
885 S.I.T. Valve Description
1) 6 Stage flame adjustment
2) Pilot adjustment
3) Outlet Pressure Tap
4) Inlet Pressure Tap
5) Pilot Outlet
6) Main Gas Outlet
7) Main Gas Inlet
44 | City Series
6. When finished reading manometer, turn off the unit, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver.
Note: Screw should be snug, but do not over tighten.
Page 45
Wiring Diagrams
installation
No electrical power supply is required for the gas control to operate. 120 Volt AC power is needed for the lights. A receptacle box, receptacle and cover are provided and located on the left hand side of the unit, under the outer base panel.
Electrical power must be brought to the appliance by a licensed electrician.
(Do not cut the ground terminal off under any circumstances.)
BLACK
Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
BATTERY CONNECTION
BATTERY
HOLDER
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three­prong receptacle. Do not cut or remove the grounding prong from this plug.
VARIABLE LIGHTS
City Series | 45
Page 46
installation
Inner glass panel (firebox glass) Installation / removal
Note: glass panels must be installed to operate fireplace
WARNING: GLASS HANDLING
We recommend using the glass vacuum holders supplied by the manufac­turer. Lower the glass to rest in a safe place, this is to prevent damage to the glass edges. Extra care must be taken when removing/installing the glass. Breakage or damage to the edge of the glass which occurs as a result of careless handling will not be covered under warranty.
We recommend handling the glass with supplied vacuum
clamps
• When removing glass–prepare a soft, scratch resistant surface to place the glass
• Never clean or remove hot glass
Note: The suction cups may leave a round film on the glass when used. Ensure that the glass is cleaned using a fireplace glass cleaner prior to operating the appliance.
Important:
Prior to installing the inner glass, ensure that there is no media present in the bottom channel as this can cause damage to the glass. Remove any media from bottom channel prior to installing the glass.
1. Remove outer safety glass panels if previously installed–see instructions in this manual.
2. CC40LE/CC40RE Single sided & CC40LE/CC40RE 3 Sided Units—Re- move outer panels installed in units - see panel removal section in this manual.
Push side glass panel rmly
to back wall until springs are
compressed—
then close
clamps.
4. With the springs compressed, close the 2 clamps at the bottom and 2 clamps at the top, by turning inward, to secure the glass in position. For the 3 sided unit, repeat on the opposite side.
Single sided units–proceed to Step 5.
3. Ensure all 4 clamps on each side are open to allow clearance for the glass. Lift up side panel using supplied vacuum clamp and tilt inward and upward positioning into a top channel and lowering gently into the lower glass chan­nel–slide the side glass panel firmly towards the back wall until the springs at the back wall are compressed.
Top clamps in
open position
Bottom side clamps in
open position
Bottom
channel
Top clamps in
closed position
Bottom clamps in
closed position
CC40LE/CC40RE shown
CC40LE/CC40RE shown
46 | City Series
Page 47
installation
5. Ensure all 7 front clamps are in the open position to allow clearance for the glass.
Open clamps prior to placing front glass panel
CC40LE shown
6. Lift up the front panel using the supplied vacuum clamps and position into the lower front channel–ensure the front panel is accurately centered—with the front panel in position—secure in place by closing the 3 lower clamps and 4 upper clamps.
Press glass vacuum clamps in open position firmly onto surface of glass. Bring handles together to close.
Note: Ensure that the front glass is centered and evenly spaced with side glass (3 sided unit) - open to release glass clamps to remove from surface of glass.
Open clamps to release pressure on the springs
7. Return to the side panel(s), and release the upper and lower clamps. The springs will release and push the glass side panel forward slightly—this will create a seal between the front and side panels. When the junction between the front and side glass panels is sealed, close the clamps to secure the side panel(s) in place.
Open
Handle front panel with supplied vacuum clamps
Closed
8. To remove the glass panels—always remove the side panel(s) (for 3 sided units) before removing the front panel.
9. Reverse steps to remove glass.
City Series | 47
Page 48
installation
Outer safety glass panel (barrier glass) Installation / removal
Note: safety glass panels must be installed to operate fireplace
3. Tilt the top of the glass panel inward and lift up and underneath
WARNING: GLASS HANDLING
We recommend using the glass vacuum holders supplied by the manufac­turer. Lower the glass to rest in a safe place, this is to prevent damage to the glass edges. Extra care must be taken when removing/installing the glass. Breakage or damage to the edge of the glass which occurs as a result of careless handling will not be covered under warranty.
We recommend handling the glass with supplied vacuum
clamps
• When removing glass–prepare a soft, scratch resistant surface to place the glass
• Never clean or remove hot glass
Note: The suction cups may leave a round film on the glass when used. Ensure that the glass is cleaned using a fireplace glass cleaner prior to operating the appliance.
Outer glass safety panels to be installed during the initial installation after the unit is in the final position.
Note: The outer safety panels come with plastic corners to protect these against damage. These should be kept in place until such time the outer safety panels are installed. Ensure these are removed prior to operating the appliance. Keep the plastic corners in a safe place if ever removing the outer panels for servicing.
the upper front panel of the outside frame. Hook the glass panel onto the pins and also onto the two angle adjustment brackets lo­cated on the frame in two locations as shown in the diagram below. Note: The front frame upper panel is shown as transparent to better illustrate the install (this area is not visible when installing glass).
1. Carefully remove glass safety panels from packaging.
Press glass vacuum clamp in open position firmly onto surface of glass. Bring handles together to close.
Open
NOTE: Inner glass panel shown in image - depicting proper handling of glass.
Closed
Pins on body of unit
Angle adjustment brackets
Note: If the outer safety glass panels do not sit at 90º and angle too far
inward or outward, remove the glass panel and adjust the screw of the panel angle bracket. Turn the panel angle bracket screw in 1/4 increments—reinstall panel to check.
Panel angle bracket—to adjust, turn screw:
Clockwise = bring panel in
2. Using the supplied vacuum clamps, lift the large front glass panel and position it front and centre by manoeuvering up and underneath the front of the unit frame.
48 | City Series
Counter clockwise= bring panel out
Page 49
Outer safety glass panel (barrier glass) Installation / removal
Note: safety glass panels must be installed to operate fireplace.
4. For 3 sided and corner units only: With front panel installed, proceed to install the side panel(s). Identify the left and right side panels before installing. Facing the front of
the unit, the right panel will show an arrow pointing to the front of the unit as shown in the diagram below.
Direction arrow on side
panel bracket, should
point toward front of
unit
Note: After the side panel has been adjusted so it is installed at 90º to the
unit and not flaring in or out, check to ensure there is no gap between the front and side panel. If there is a gap as shown below, slide the side panel to adjust the position and close the gap.
installation
5. Lift up the side panel with the supplied glass clamps (see procedure on previous page). Tilt the side of the glass panel inward and lift up and under­neath the upper side panel and hook the 2 outer hooks on to the pins, there is also a panel angle adjustment bracket for the third hook.
Note: The side frame upper panel is shown as transparent to better illustrate the install (this area is not visible when installing glass).
Note: If the outer safety glass side panels angle too far inward or outward,
remove the side glass panel and adjust on the panel angle bracket, see details on previous page.
6. Repeat Steps 4 and 5 to install the opposite side panel.
7. Reverse Steps to remove all panels.
Note: When removing panels, we recommend using the supplied glass clamps.
City Series | 49
Panel angle bracket
Page 50
installation
CITY SERIES
CONVERSION FROM NG TO LP
CV40E/ CB40E using SIT 885 NOVA Gas Valve
LP Conversion Instructions
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION!
WARNING
This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufac­turer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If these instructions is not followed exactly, a fi re, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualifi ed service agency is re­sponsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specifi ed in the manufacturer’s instructions sup­plied with the kit.
Conversion Kit 656-969 includes:
1 911-191 Stepper Motor LP for 885 SIT
1 904-947 Orifi ce #53
1 910-101 Pilot Orifi ce #35
1 918-590 Decal - Conversion to LP
1 908-528 Label Propane
1 904-529 5/32" long Allen Key
Caution: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.
Always let the appliance cool to room temperature before servicing.
1. Remove the outer panels and safety glass — see manual.
6. If unable to access this Cable - undo 2 screws securing the IFC Board and slide out of unit to access cable.
7. Remove and discard 2 Pressure regulator screws (A)using a (T20 or slot screwdriver,) Pressure Regulator (B) and Spring and Diaphragm (C) (see below).
8. Ensure the rubber gasket, which is prefi tted as part of the Assembly,
is properly positioned. Install the new Pressure Regulator using the 2x M4 x .7 screws supplied. Tighten the screws to 25lb-in. In the event that the screw threads are cross threaded or stripped, replace the valve as­sembly.
Install the enclosed propane identifi cation label to the valve body where it can be easily seen.
Pressure regulator
screws
2. Remove inner ceramic glass — see manual.
3. Remove inner panels — see manual.
4. Remove all media installed on burner (glass, logs or stones, etc).
5. Disconnect the Cable coming from the Pressure Regulator Motor.
50 | City Series
9. Re-attach the Pressure Regulator wire (disconnected in Step 6), and re­situate the IFC, secure the screws that fasten the IFC Mounting Brackets.
10. Remove pilot hood by lifting up and off.
Cable from motor
Page 51
CITY SERIES
11. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide burner to the left away from the orifi ce and lift out.
front
screw locations
back screw locations
installation
14. Unscrew the pilot orifi ce with the allen key; then replace with the LPG pilot orifi ce and the pilot cap, provided in the kit.
12. Remove burner orifi ce with a 3/8" wrench. Use another wrench to hold on to the elbow behind the orifi ce. Discard orifi ce. Reinstall new burner orifi ce LPG stamped #53 and tighten.
CV40E shown
13. Remove pilot retainer clip with pliers and pull off the pilot cap to expose the pilot orifi ce.
Burner Orifi ce
Location
15. Reinstall pilot cap and pilot retainer clip.
16. Prior to installing burner—adjust aerations settings - to 1/4" for LP. Reinstall burner (see Step 13).
17. Ensure the pilot light is in the correct orientation to the Burner. Recon­nect the gas and electrical supply to the appliance. Start the appliance. (see section on Lighting Instructions) Ensure that pilot and burner igni­tion is completed without delay. Check both your inlet and outlet pres­sures at full load. With a soapy solution, leak test the entire system. Verify both the correct fl ame and pilot appearance.
11. See Gas Pipe Pressure Testing in manual.
City Series
LP SYSTEM DATA
Min. Supply Pressure 11" WC (2.73kpa)
Manifold Pressure - High 10.5" WC (2.62 kpa)
Manifold Pressure - Low 2.9" WC (0.72 kpa)
Orifi ce Size #53 DMS
Maximum Input 28,500 Btu/h (8.35 kW)
Minimum Input 15,500 Btu/h (4.54 KW)
Altitude 0-4500 ft (0-1372m)
Pilot retainer clip
City Series | 51
Installer Notice:
These instructions must be left
with the appliance.
Page 52
installation
CC40RE/CC40LE INNER PANELS
5. Manoeuvre in side panel to the side wall of the unit—secure in place
The CC40RE/CC40LE can be equipped with optional steel inner panels.
CITY SERIES
CC40LE/CC40RE Painted panel installation
Inner Panels - CC40LE/CC40RE
There are 4 outer panels and 3 inner panels.
NOTE: CC40RE shown in diagrams—CC40LE panels install in the same order. Installed panels for the CC40LE will appear as mirror images of diagrams shown below.
Turn off unit and allow to cool to room temperature. Remove the safety glass and firebox glass — see manual for instructions.
1. Install inner lower base panel.
2. Install panel clips into the slots at the top of the back panel as shown.
with 1 panel clips and 1 screws.
Panel Clip
6. Reverse steps to remove panels.
Outer Panels - CC40LE/CC40RE
CC40RE/CC40LE OUTER PANELS
Note: Install inner safety glass prior to installation of outer panels-see instructions in manual
1. Attach Regency logo to the right hand side of outer front panel. The magnets will be positioned under the outer front base panel to secure the logo. The logo should be about 3 inches from the right hand corner of the outer base. Install outer front and side base panel.
3. Manoeuvre in back panel to the back wall of the unit—secure in place with 2 panel clips and 2 screws.
Panel Clips
4. Install panel clip into the slots at the top of the
side panel as shown.
Location of
Regency Logo
Outer base panel install
2. Install side panels - the side panels are secured in place by existing magnets in the unit.
Outer side panel install
3. Install outer safety glass.
4. Reverse steps to remove panels.
52 | City Series
Page 53
CC40LE/CC40RE glass panel installation
CC40LE/CC40RE GLASS PANEL INSTALLATION
CITY SERIES
installation
1. Turn off unit and allow to cool to room temperature. Remove the outer safety glass and inner ceramic fi rebox glass panels and any media installed — see manual for instructions. CC40RE shown in diagrams.
NOTE: CC40RE shown in diagrams—CC40LE panels install in the same or­der. Installed panels for the CC40LE will appear as mirror images of diagrams shown below.
2. Identify panels and order of installation.
Y5PQ$PSOFS#SBDLFU$$-
Y5PQ$PSOFS#SBDLFU$$3
Y5PQ#BDL#SBDLFU
Y5PQ4JEF#SBDLFU
4. Slide the supplied bottom corner bracket behind the small panel (1) and the back and side walls, in the orientation shown below.
bottom
corner bracket
656-206
base panel
back bracket
base panel
5. Carefully manoeuvre the back glass panel (2) to the back wall of the fi rebox. Center the glass panel and position bottom of panel into brackets installed in step 4. Place the 2 top back brackets on the top edge of the glass and secure to the unit with one screw on each side once back glass panel is in position.
back wall of unit
back wall of unit
bottom
656-218
Y#PUUPN#BDL#SBDLFU
Y#PUUPN$PSOFS#SBDLFU
Glass Panel Parts Layout
3. Install the inner base panel (1) around burner as shown below.
bottom corner
brackets
Top back
bracket
orientation
656-202
Top back
bracket location
656-202
City Series | 53
Page 54
installation
Bottom Side Bracket
CITY SERIES
6. Carefully manoeuver the Side Glass Panel (3) into the side of the fi re­box. Position the bottom of the panel into the Bottom Corner Bracket and secure the top using the Top Side Bracket as shown. Once in position, secure the Top Side Bracket to the side wall with one screw. Slide the appropriate Top Corner Bracket over the corner between the Side and Back glass panels.
656-205
656-203
Use with CC40R
656-203
656-204
Use with CC40L
656-202
9. Install outer side base panel (5) — panel 5 rests on the tab of panel 4.
anel 7
Panel 5
Tab on Panel 4
10. Install outer side panels (6, 7) — both panels are held in position with magnets.
nel 6
7. Reinstall inner ceramic fi rebox glass panels (see manual for instructions).
8. Install front outer base panel (4) Note: there are tabs on panel 4 that should face inward.
Panel 4
Panel 6
Tab
Outer side panels
(6, 7)
11. Install outer safety barrier glass (3 pieces). See manual for instructions.
12. Reverse Step 1 to reassemble unit.
13. Reverse steps to remove panels.
54 | City Series
Page 55
maintenance
CITY LINE
CC40LE/CC40RE enamel panel installation
Black Enamel Panels — Handling Instructions
Black Enamel panels must be inspected for scratches and dimples prior to installation.
All claims to be recorded at this time. Claims for damage after installation will not receive consideration.
Black Enamel panels will discolor a little during normal operation. This is normal and should not be considered a defect.
All hand and fi nger marks MUST be cleaned off with a soft cloth. Use an ammonia based cleaner (ie. glass cleaner) to remove any fi ngerprints before
*
applying heat to the unit.
Failure to do this will result in burn stain on panels which you will be unable to remove and will not be protected by product warranty.
The CC40RE/CC40LE can be equipped with optional enamel panels. There are 4 outer panels and 3 inner panels.
NOTE: CC40RE shown in diagrams—CC40LE panels install in the same order. Installed panels for the CC40LE will appear as mirror images of diagrams shown below.
Tu rn off unit and allow to cool to room temperature. Remove the safety glass and fi rebox glass — see manual for instructions
CC40RE/CC40LE INNER PANELS
1. Install inner lower base panel.
2. Install panel clips into the slots at the top of the back panel as shown.
3. Manoeuvre in back panel to the back wall of the unit—secure in place with 2 panel clips and 2 screws.
Panel Clips
4. Install panel clip into the slots at the top of the side panel as shown.
5. Manoeuvre in side panel to the side wall of the unit—secure in place with 1 panel clip and 1 screw.
City Series | 55
Panel Clip
6. Reverse steps to remove panels.
Page 56
maintenance
CC40RE/CC40LE OUTER PANELS
CITY LINE
Note: Install inner safety glass prior to installation of outer panels-see instructions in manual
1. Attach Regency logo to the right hand side of outer front panel. The magnets will be positioned under the outer front base panel to secure the logo. The logo should be about 3 inches from the right hand corner of the outer base. Install outer front and side base panel.
Location of
Regency Logo
Outer base panel install
2. Install side panels - the side panels are secured in place by existing magnets in the unit.
Outer side panel install
3. Install outer safety glass.
4. Reverse steps to remove panels.
56 | City Series
Page 57
installation
Burner and Firebox media options
Spread the media evenly over the burner. Ensure the glass/stones do not overlap excessively as this will affect the flame pattern.
IMPORTANT NOTE:
Only the supplied approved media are to be used with these fireplaces. Use of any other type of glass or stones can alter the unit's performance. Any damage caused by the use of any unapproved glass or stones will not be covered under warranty. When using Ceramic Spa/Volcanic Stones ensure required glass crystals/beads are used as a base. DO NOT overstack Ceramic Spa Stones or Volcanic Stones on burner or in the pilot area. Media must be installed on and around burner only in amounts noted below.
CC40LE/CC40RE Approved Media*
Fireglass (starfire, copper or black) On burner 1.5 lbs
Glowing embers/sea wool (supplied with unit) On burner 1 bag
Natural Stones Around burner 1 box = 15lbs
Ivory Natural Stones Around burner 1 box = 15lbs
3/4" Crushed black glass Around burner 3.5lbs
Crushed Iceburg chips Around burner 3.5lbs
Firebeads Around burner 3.5lbs
Spa stones Around burner 2 boxes
Lava Embers Around burner 6 packages
Stone River Pebbles Around burner 2 bags
* Media not supplied with unit - must be purchased separately.
3/4" Crushed black glass + Black Fireglass
Where Used Quantity
Natural / Ivory Stones + Fireglass
Starre Fireglass + Iceburg chips
Fireglass + Firebeads
Lava Embers + Black Fireglass
City Series | 57
Spa Stones + Fireglass
Stone River Pebbles + Fireglass
Page 58
installation
CITY LINE
CITY LINE - LOG INSTALLATION
Optional driftwood Log set Installation
Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.
Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
*Dark brown paint is included if touch ups are required.
1 Rear Log
2 Left Log
3 Right Log
4 Left Cross Log
5 Right Cross Log
6Front Left Log Piece
7Front Right Log Piece
Log Brackets (3)
Lava rock (purchased separately from log set)
1.5 lb Black Fireglass (purchased separately from log set)
Glowing wool (supplied with unit)
3/4" Crushed black glass or iceburg chips (purchased separately from log set)
5. Clip on the log guides - position the rear guides by centering over the second and fourth ver tical lines at the back of the burner. The front log guide clips on to the front edge of the burner on the right side as shown below.
Log Guides - location of log guides,
1
6. Centre Log 1 and rest on installed rear log guides—with pins facing up.
2 rear - 1 front
Log guides
2
4
3
5
6 7
1. S hut off gas and electrical supply, allow unit to cool to room temperature.
2. Remove safety glass and fi rebox glass (see manual).
3. Carefully remove the logs from the packaging and unwrap them. The logs are fragile, handle with care—never force into position.
4. Install Black Fireglass(1.5lb) and glowing wool on the burner as shown below.
Burner covered with Fireglass and glowing wool
1
Log 1 in position
7. Position Log 2 on the burner—the longest point of Log 2 should sit level at the left edge of the burner — the other end of the log on a slight diagonal to the front of the fi rebox as shown.
Point of log to edge
of burner
2
2
Log 2 in position
58 | City Series
Page 59
installation
CITY LINE
8. Place the split end of Log 3 to the right front corner of the burner—angle the log so that the other end is sitting approximately 1/2" (13mm) from the edge of the burner tray.
Log to corner of
3
Log 3 placement
9. Place Log 6 and Log 7 on the burner locations shown below.
10. Before placing the next log—spread the optional media evenly
throughout the burner tray as shown.
3/4" Crushed black
glass on burner tray
burner
Rest the other end of Log 4 on the indent in Log 2 as shown below.
4
Indent Log 2
2
12. Place Log 5—identify the pin locator and match with the right side pin on Log 1.
Pin in Log 1
5
1
7
6
NOTE: Ensure the installed optional media doesn't completely block the air fl ow—ensure more than 50% of the airfl ow is open (shown with 3/4" crushed black glass).
Do not completely
block air fl ow
11. Place Log 4—identify the pin locator and match with the left side pin on Log 1.
Pin in Log 1
4
3
Rest the other end of Log 5 on the indent in Log 3 as shown below.
5
Add lava rock sparsely around the perimeter of the burner.
City Series | 59
Completed Install
Page 60
installation
CC40LE/CC40RE - Removable drywall guides
(when using 1/2" drywall)
An optional finishing trim is available to finish the edges of the installation on the CC40RE/CC40LE unit. Installation is as follows:
1. Remove the outer safety glass and outer front and side panels - see in­structions in manual.
2. Loosen 3 screws inside the lower front edge of the unit to release existing lower drywall guide and remove guide.
Note : an offset screwdriver is provided with the appliance for ease of removal/
installation of the lip and finishing trim.
Lower drywall
guides
Loosen and tighten screws on drywall guide from inside front panel
3. Loosen 2 screws from inside the firebox to release the existing side drywall guide, remove guide and recycle.
5. Reverse steps to reinstall drywall guides (if applicable). If discarding, please recycle.
4. Loosen 2 screws from inside the firebox to release the existing side drywall guide, remove guide and recycle.
Loosen 2 screws from inside the rebox to remove the side drywall trim
pieces
60 | City Series
Page 61
operating instructions
First Fire
The FIRST FIRE in your fireplace is part of the paint curing process. To ensure the paint is prop­erly cured, it is recommended you burn your fireplace for at least four (4) hours the first time.
When first operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac­turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.
NOTE: When the glass is cold and the
appliance is lit, it may cause con­densation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.
DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!
DO NOT BURN THE UNIT WITHOUT THE GLASS IN PLACE.
During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.
Normal Operating Sounds of Gas Appliances
It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.
Burner Tray:
The burner tray is positioned directly under the burner tube(s) media and logs and is made of a different gauge material from the rest of the firebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fireboxes.
Pilot Flame: While the pilot flame is on it can make a very slight "whisper" sound.
Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.
Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.
Aeration Adjustment
The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame.
Remove outer safety glass and inner glass panels plus outer and inner base panels - see instructions in this manual.
2. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide burner to the left away from the orifice and lift out.
front
screw locations
back screw locations
3. Reverse steps to reinstall burner.
Minimum Air Shutter Opening:
NG Fully closed NG with Logs Fully closed NG with Stones Fully closed
LP 1/4" LP with Logs 1/4" LP with Stones 1/4"
Note: Any damage due to carboning
resulting from improperly setting the aeration controls is NOT covered under warranty.
City Series | 61
Page 62
operating instructions
Lighting Procedure
IMPORTANT: The remote control system supplied with this appliance has
several options for starting/operating the appliance using the battery holder and ON/OFF key on the hand held transmitter.
Prior to operating this appliance, please read the remote control operating
instructions (packaged with remote control) to understand how to operate this remote control system.
1. Ensure the battery holder switch is in the Remote position and / or wall mounted battery holder (if equipped) is in the <REMOTE> position.
2. Press and release the ON/OFF button on the remote handheld transmitter (see Diagram 1). An audible beep should be heard from the receiver. If not using the remote, the unit can also be turned on by sliding the battery holder switch to the <ON> position (if equipped).
ON/OFF Button
Note: The first try for ignition will last approximately 60 seconds. If there is no
flame ignition (rectification) the board will stop sparking for approximately 35 seconds. After wait time , the board will start second try for ignition by sparking for approximately 60 seconds . If there is still no positive ignition the board will go into lock out.
The system will need to be reset as follows:
a) Turn the system off by pressing the ON/OFF button on the remote. b) Wait 5 minutes then repeat from step 2.
Shutdown Procedure
1. Press the ON/OFF button on the remote
2. If service is to be performed, you must disconnect power and shut off gas
to the unit.
*
Remote shown in Manual Mode on Hi
Diagram 1
3. After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.
4. The unit will turn on.
*
*
*
* Not offered on all models.
Continuous Pilot/Intermittent Pilot (CPI/IPI) selection
See remote control instructions for details.
62 | City Series
Page 63
Copy of the Lighting Plate Instructions
operating instructions
POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE
FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.
Cet appareil doit être installé conformément aux codes locaux, s’il y a lieu. En l’absence de tels codes, suivre le National Fuel Gas Code, ANSI Z223.1/NFPA 54, ou les Natural Gas and Propane Installation Codes, CSA B149.1.
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.
AVERTISSEMENT : Quiconque ne respecte pas scrupuleusement les instructions de la présente notice risque de déclencher un incendie ou une explosion pouvant entraîner des dégâts matériels ou des blessures pouvant être mortelles. Tout défaut d'installation, de réglage, de modication, de service ou d'entretien peut entraîner des blessures ou des dom­mages matériels. Reportez-vous au manuel d'utilisation fourni avec cet équipement. Pour obtenir de l'aide ou des informa-
tions complémentaires, consulter un installateur ou un service d'entretien qualié, ou le fournisseur de gaz.
A) This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B) BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch, do not use any phone in your building.
- Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the re department.
C) Do not use this appliance if any part has been under water. Immediately call a qualied service
technician to inspect the appliance and replace any part of the control system and any gas control which has been underwater.
A) Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse manuellement.
B) AVANT LA MISE EN MARCHE, reniez tout autour de l’appareil pour déceler une odeur de gaz. Reniez au niveau du plancher, car certains gaz
sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne tentez pas d’allumer l’appareil
• Ne touchez à aucun interrupteur; n'utilisez pas de téléphones se trouvant dans le bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur. Suivez les instructions du fournisseur.
• Si vous ne pouvez pas rejoindre le fournisseur, appelez le service incendie. C) N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement. Faites inspecter l’appareil par un technicien qualié et remplacez
tout élément du système de contrôle ou de commande qui a été plongé dans l’eau.
CAUTION: Hot while in operation. Do not touch. Severe burns may result. Due to high surface temperatures keep
children, clothing and furniture, gasoline and other liquids having ammable vapors away. Keep burner and control
compartment clean. See installation and operating instructions accompanying appliance.
ATTENTION : Surfaces chaudes lorsque l’appareil est en marche. Ne pas toucher. Risque de brûlures graves. En raison des températures élevées, les enfants, les vêtements et le mobilier, le carburant et tout autre liquide aux vapeurs
inammables doivent être tenus éloignés de l’appareil. Nettoyer régulièrement le brûleur et le compartiment des
commandes. Voir les consignes d’installation et d’utilisation fournies avec l’appareil.
LIGHTING INSTRUCTIONS / CONSIGNES D’ALLUMAGE
1) Ensure the Main switch is in the ON position and/or the wall mounted battery holder (if equipped) is in the <REMOTE> position.
2) Press and release the ON/OFF button on the remote handheld transmitter. An audible beep should be heard from the receiver. If not using the remote, the unit can also be turned on by sliding the battery holder switch to the <ON> position (if equipped).
3) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.
4) The unit will turn on.
Note: The rst attempt to ignition will last approximately 60 seconds. If there is no ame ignition (rectication) the board will stop spark­ing for approximately 35 seconds. After this wait time, the board will start a second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the second attempt the board will go into lock out. The system will need to be reset as follows (after going into lock out mode): a) Wait 5 minutes - turn the system off by pressing the ON/OFF button on the remote. b) After approximately 2 seconds press the ON/OFF button again. c) Unit will repeat step 2.
1) S’assurer que le commutateur principal est en position ON et/ou que le bloc-piles mural (le cas échéant) est en position <REMOTE>.
2) Appuyer sur la touche ON/OFF de la télécommande puis relâcher. Un bip sonore retentira depuis le récepteur. Si vous n'utilisez pas la télécommande, l'appareil peut également être allumé en faisant glisser le commutateur du bloc-piles sur la position <ON> (le cas échéant).
3) Après environ 4 secondes, le système d'allumage produira une étincelle pendant 60 secondes pour allumer le brûleur principal.
4) L'appareil s’allumera.
Remarque : Au premier allumage, le système tente d’allumer les ammes pendant 60 secondes. Si l’essai est infructueux, le système fera une pause de 35 secondes. C’est ce qu'on appelle l'étape de rectication. Ce délai écoulé, le système tente à nouveau d'allumer les ammes en produisant des étincelles pendant 60 secondes. Si les ammes ne s’allument toujours pas, le système se met en mode ver-
rouillage. Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) : a) Attendre 5 minutes et éteindre l’appareil en appuyant sur la touche ON/OFF de la télécommande. b) Attendre 2 secondes et appuyer encore une fois sur la touche ON/OFF.
c) L'appareil répètera l'étape 2.
TO TURN OFF GAS APPLIANCE / POUR ÉTEINDRE UN APPAREIL AU GAZ
1) Press the ON/OFF button on the remote.
2) If service is to be performed–you must disconnect power and shut off gas to the unit.
Appuyer sur la touche ON/OFF de la télécommande.
1)
2) Lors de l'entretien de l'appareil, vous devez débrancher l'alimentation électrique et couper le gaz alimentant l'appareil.
DO NOT REMOVE THIS INSTRUCTION PLATE
NE PAS ENLEVER CETTE ÉTIQUETTE D’INSTRUCTIONS
919-649
City Series | 63
Page 64
maintenance
Maintenance Instructions
1. Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.
2. Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner. The glass should be
cleaned when it starts looking cloudy.
3. The fireplace is finished in a heat resistant paint and should only be refinished with heat resistant paint. Regency® uses StoveBright Paint - Metallic Black #6309.
4. Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call a qualified service person.
5. The appliance and venting system must be inspected before use, and at least annually, by a qualified field service person, to ensure that the flow of combustion and ventilation air is not obstructed.
and exterior portions of the system being exposed to cold weather.
4. Inspect joints, to verify that no pipe sections or fittings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.
Log Replacement
The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.
Note: Improper positioning of logs may
create carbon build-up and will severely alter the unit's performance which is not covered under warranty.
Glass Gasket
If the glass gasket requires replacement use a tadpole glass gasket (Part # 936-220).
Glass replacement
In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only. Replacement glass is shipped already installed into the door frame. Reinstall as per Glass Installation in the "Glass Installation" section.
REPLACEMENT GLASS:
CC40LE/CC40RE
Inner Glass Front - Ceramic (Part# 940-436/P) Inner Glass Side - Ceramic (Part# 940-437/P)
CC40LE
Outer Safety Glass Side - Tempered Large #940-486/P Outer Safety Glass Side - Tempered Small # 940-439/P
CC40RE
Outer Safety Glass Side - Tempered Large #940-485/P Outer Safety Glass Side - Tempered Small #940-440/P
Note: Never operate the appliance without
the glass properly secured in place.
6. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water.
7. In the event this appliance has been serviced check that the vent-air system has been properly resealed & reinstalled in accordance with the manufacturer's instructions.
8. Verify operation after servicing.
General Vent Maintenance
Conduct an inspection of the venting system semi­annually. Recommended areas to inspect as follows:
1. Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately.
2. Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.
Glass
Your Regency® fireplace is supplied with high temperature 5mm-Tempered outer glass & 5mm­Ceramic inner glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot. * The use of substitute glass will void all product warranties. * Care must be taken to avoid breakage of the glass. * Do not strike or abuse the glass. * Do not operate this fireplace without the glass front or with a cracked or broken glass front. * Wear gloves when removing damaged or broken glass. * Replacement of the glass panels should be done by a licensed or qualified service per son.
3. Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows,
64 | City Series
Page 65
Bulb Replacement
maintenance
1. Turn off unit and allow to cool to room temperature.
2. Remove outer safety glass panels and inner panels (firebox glass)–see instructions in this manual.
3. Loosen 2 outer screws on each side to remove outer light cover — located in the upper inside front of the firebox and remove.
4. Loosen 2 screws on each side of individual inner light cover and remove.
5. Remove glass cover by using a flat head screwdriver to pry the tab securing the glass assembly in place.
6. Replace bulb and reverse steps to complete procedure.
NOTE: Do not handle bulb with bare hands. Use packaging or a tissue to hold
new bulb when replacing.
Regency Part# 911-208 Oven Lamp Assembly G9 120V/25W Regency Part# 911-072 Replacement Bulb G9 120 Volt/25 watt
City Series | 65
Page 66
maintenance
tooltip
Valve Replacement
Important: Always shut off gas supply/120 volt power prior to servicing the
gas valve.
1. Turn off unit and allow to cool to room temperature.
2. Remove outer enamel or steel panels—see instructions in the panel removal section in this manual
3. Remove outer safety glass panels and inner panels (firebox glass)–see instructions in this manual.
4. Remove all media and logs (if installed) — set aside.
5. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide burner to the left away from the orifice and lift out.
front
screw locations
7. Lift valve tray by out partially and disconnect flexible gas connection on the valve inlet side, remove valve tray- replace with new valve tray.
8. Reverse steps 6-1 to complete.
back screw locations
6. Remove 16 screws in locations shown below.
Remove 16 screws securing valve tray
66 | City Series
Page 67
CC40LE main assembly
parts list
1 656-525 Burner Assembly - NG/LP
2 656-046 Pilot Cover/Shield
4 911-006 Pilot Assembly IPI NG 2 Flame 0.199.050
4 911-007 Pilot Assembly IPI LP 2 Flame
5 911-188 Novasit Valve Only - NG 885 SIT IPI 0.885.009
5 911-189 Novasit Valve Only - LP 885 SIT IPI
6 656-276 IFC Cover/Shield
6A 911-174 IFC Board Complete 584.306
7 656-045 Burner Surround
8 940-486/P Outer Barrier Tempered Glass Assembly - Large
9 940-436/P Flush Inner Ceramic Glass - Large
N/S 656-062 Outer Base Cover Black
10 940-439/P Outer Safety Glass Side - Tempered Small
11 940-437/P Flush Inner Ceramic Glass Small
17 656-574/P Valve Assembly - NG
17 656-576/P Valve Assembly - LP
18 656-033F Bottom Cover Access Plate
18 656-034 Bottom Cover Access Gasket
19 656-309 Removable Drywall Finishing
20 656-124 Removable Drywall Finishing Trim
22 911-190 Stepper Motor NG SIT 0.907.015
22 911-191 Stepper Motor LP SIT 0.907.015
23 656-125 Removable Drywall Vertical Finishing Trim Left/Right
24 656-241F Nailing Strip Side
25 656-247F Nailing Strip Top
N/S 936-219 Gasket 5/8 (09) Sewn Rope Graphite 3/4 PSA 10
(Sold per Foot 10 Feet Required)
N/S 904-943 Bracket Dormont Orifice Mount 10-BZ001-19.5
N/S 936-220 Gasket Tape 2" Wide Graphite Wrap
N/S 656-051 Baffle Cover (Each)
N/S 904-996 Burner Orifice #42 NG (PO512)
N/S 904-947 Burner Orifice #53 LP (PO512)
N/S 910-100 Pilot Orifice SIT - NG #62 977.166
N/S 910-101 Pilot Orifice SIT - LP #35 977.168
N/S 911-037 Flame Sensor 0.915.905
N/S 911-038 Flame Electrode 0.915.020
N/S 910-432 Novasit Pilot Tubing With Nuts
N/S 911-039 Two Way Pilot Hood
N/S 911-137 Pilot Hood Clip
N/S 904-658 Inlet Flex Line Gas SS Steel 24 inch
N/S 904-606 Fitting 90 Street Elbow Extruded
N/S 904-165 Fitting 3/8 Male Flarex Mpt Strt Adaptor
N/S W840470 Pilot Assembly Gasket
N/S 656-040 Valve Assembly Gasket
N/S 656-039 Burner Orifice Mount Gasket
N/S 911-175 Hand Held Remote Control GTMFL SIT 0.584.042
N/S 911-187 Remote Receiver/Battery Holder 584.103
N/S 910-576 Cover Wall Mount White GTM SIT 0.584.803
N/S 911-173 Wire Harness IFC No CPI Switch 584.924
N/S 911-177 Wire 4 Position IFC Fan & Light
N/S 911-181 Wire Harness Battery Box Proflame II
N/S 911-192 Power Cord 120 Volts With Connector
N/S 911-193 Connector With Jumper
N/S 911-209 Wire 2 Position IFC to Lights
N/S 910-369 Receptacle Box Low Voltage SC100A
N/S 910-428 Receptacle Duplex White
N/S 910-429 Receptacle Box Duplex Metal
N/S 910-430 Receptacle Cover Duplex Metal
N/S 904-687 Connector Clamp 3/8 CI-804
N/S 948-078 Glass Suction Cup (Each)
N/S 904-790 Magnet Round 1/2 inch (Each)
N/S 904-970 Magnet Cup 1/2 inch (Each)
N/S 948-223 Logo Plate Plastic Regency/Flame Silver
N/S 656-131 Logo Mounting Bracket
N/S 656-017F Restrictor Plate
N/S 656-018 Pressure Relief Base
N/S 656-023 Pressure Relief Base Gasket
N/S 656-019 Pressure Relief Bracket Right
N/S 656-020 Pressure Relief Bracket Left
N/S 656-021F Pressure Relief Door
N/S 656-022 Pressure Relief Door Gasket
N/S 656-075F Rear Standoff (Each)
N/S 911-208 Oven Lamp Assembly G9 120V 25W
N/S 656-086 Light Glass Bracket
N/S 911-072 Replacement Bulb G9 120 Volt/25 watt
N/S 656-087 Light Rear Louver
N/S 656-088 Light Cover Plate
N/S 656-089 Light Deflector Shield
N/S 656-085 Gasket Light Cover Gasket
N/S 656-079 Top Glass Clamp Left (Each)
N/S 656-080 Top Glass Clamp Right (Each)
N/S 656-269 Lower Glass Clamp (Each)
N/S 656-052 Lower Glass Clamp Bracket (Each)
N/S 656-617 Pressure Relief Door Frame Assembly/Includes Gasket
Optional Accessories
11 656-926* Inner Panel Glass Black
11 656-927* Inner Panel Black (Painted)
11 656-928* Inner Panel Enamel Black
* Sold only as complete sets
N/S 656-202 Top Rear Panel Clip (Used on the 656-926)
N/S 656-203 Top Corner Bracket (Used on the 656-926)
N/S 656-205 Glass Panel Top Side Bracket (Used on the 656-926)
N/S 656-205 Lower Corner Glass Bracket (Used on the 656-926)
N/S 656-218 Rear Base Panel Bracket (Used on the 656-926)
N/S 656-291 Inner Top Panel Clip (Used on the 656-927)
City Series | 67
Page 68
parts list
N/S 656-059 Inner Top Panel Clip (Used on the 656-928)
N/S 656-930/P Driftwood Log Set
N/S 656-969 Conversion Kit - LP
N/S 656-991 Chase Vent Front Black
N/S 656-995 Adaptor Heat Wave
N/S 946-556 Heatwave Kit
N/S 946-672 Stones - River Pebbles
N/S 946-674 Stones - Ceramic Spa (70 stones)
N/S 946-675 Fireglass Black Reflective 1/4in.1Lb Pkg
N/S 946-676 Fireglass Copper 1/4 in. 1Lb Pkg
N/S 946-677 Fireglass Starfire 1/4 in. 1Lb Pkg
N/S 946-775 Fireglass Black Reflective 1/4in.5Lb Pkg
N/S 946-776 Fireglass Copper 1/4 in. 5Lb Pkg
N/S 946-777 Fireglass Starfire 1/4 in. 5Lb Pkg
N/S 946-780 Crushed Glass Coal Black 3/4in. 3.5 Lbs
N/S 946-781 Crushed Glass Iceberg Chips 3/4in. 3.5 Lbs
N/S 946-735 Firebeads Black 1 Lb Pkg
N/S 946-736 Firebeads Sangria Luster 1 Lb Pkg
N/S 946-737 Firebeads Glacier Ice 1 Lb Pkg
N/S 946-738 Firebeads Caramel Luster 1 Lb Pkg
N/S 946-739 Firebeads Black 5 Lb Pkg
N/S 946-740 Firebeads Sangria Luster 5 Lb Pkg
N/S 946-741 Firebeads Glacier Ice 5 Lb Pkg
N/S 946-742 Firebeads Caramel Luster 5 Lb Pkg
N/S 946-710 Stones -Slate/Grey Basalt Natural 15 lbs
N/S 946-711 Stones - Ivory/Tan Basalt Natural 15 lbs
25
20
18
6a
22
11
10
19
23
24
9
8
12
May not be exactly as shown
7
2
1
6
4
5
17
68 | City Series
Page 69
CC40RE main assembly
parts list
1 656-525 Burner Assembly - NG/LP
2 656-046 Pilot Cover/Shield
4 911-006 Pilot Assembly IPI NG 2 Flame 0.199.050
4 911-007 Pilot Assembly IPI LP 2 Flame
5 911-188 Novasit Valve Only - NG 885 SIT IPI 0.885.009
5 911-189 Novasit Valve Only - LP 885 SIT IPI
6 656-276 IFC Cover/Shield
6A 911-174 IFC Board Complete 584.306
7 656-045 Burner Surround
8 940-486/P Outer Barrier Tempered Glass Assembly - Large
9 940-436/P Flush Inner Ceramic Glass - Large
N/S 656-062 Outer Base Cover Black
10 940-438/P Outer Safety Glass Side - Tempered Small
11 940-437/P Flush Inner Ceramic Glass Small
12 936-219 Gasket 5/8 (09) Sewn Rope Graphite 3/4 PSA 10
(Sold per Foot 10 Feet Required)
N/S 936-220 Gasket Tape 2" Wide Graphite Wrap
17 656-574/P Valve Assembly - NG
17 656-576/P Valve Assembly - LP
18 656-033F Bottom Cover Access Plate
18 656-034 Bottom Cover Access Gasket
19 656-127 Removable Drywall Finishing Trim
20 656-293 Removable Drywall Finishing Trim
22 911-190 Stepper Motor NG SIT 0.907.015
22 911-191 Stepper Motor LP SIT 0.907.015
23 656-125 Removable Drywall Vertical Finishing Trim Left/Right
24 656-241F Nailing Strip Side
25 656-247F Nailing Strip Top
N/S 904-943 Bracket Dormont Orifice Mount 10-BZ001-19.5
N/S 656-051 Baffle Cover (Each)
N/S 904-996 Burner Orifice #42 NG (PO512)
N/S 904-947 Burner Orifice #53 LP (PO512)
N/S 910-100 Pilot Orifice SIT - NG #62 977.166
N/S 910-101 Pilot Orifice SIT - LP #35 977.168
N/S 911-037 Flame Sensor 0.915.905
N/S 911-038 Flame Electrode 0.915.020
N/S 910-432 Novasit Pilot Tubing With Nuts
N/S 911-039 Two Way Pilot Hood
N/S 911-137 Pilot Hood Clip
N/S 904-658 Inlet Flex Line Gas SS Steel 24 inch
N/S 904-606 Fitting 90 Street Elbow Extruded
N/S 904-165 Fitting 3/8 Male Flarex Mpt Strt Adaptor
N/S W840470 Pilot Assembly Gasket
N/S 656-040 Valve Assembly Gasket
N/S 656-039 Burner Orifice Mount Gasket
N/S 911-175 Hand Held Remote Control GTMFL SIT 0.584.042
N/S 911-187 Remote Receiver/Battery Holder 584.103
N/S 910-576 Cover Wall Mount White GTM SIT 0.584.803
City Series | 69
N/S 911-173 Wire Harness IFC No CPI Switch 584.924
N/S 911-177 Wire 4 Position IFC Fan & Light
N/S 911-181 Wire Harness Battery Box Proflame II
N/S 911-192 Power Cord 120 Volts With Connector
N/S 911-193 Connector With Jumper
N/S 911-209 Wire 2 Position IFC to Lights
N/S 910-369 Receptacle Box Low Voltage SC100A
N/S 910-428 Receptacle Duplex White
N/S 910-429 Receptacle Box Duplex Metal
N/S 910-430 Receptacle Cover Duplex Metal
N/S 904-687 Connector Clamp 3/8 CI-804
N/S 948-078 Glass Suction Cup (Each)
N/S 904-790 Magnet Round 1/2 inch (Each)
N/S 904-970 Magnet Cup 1/2 inch (Each)
N/S 948-223 Logo Plate Plastic Regency/Flame Silver
N/S 656-131 Logo Mounting Bracket
N/S 656-017F Restrictor Plate
N/S 656-018 Pressure Relief Base
N/S 656-023 Pressure Relief Base Gasket
N/S 656-019 Pressure Relief Bracket Right
N/S 656-020 Pressure Relief Bracket Left
N/S 656-021F Pressure Relief Door
N/S 656-022 Pressure Relief Door Gasket
N/S 656-075F Rear Standoff (Each)
N/S 911-208 Oven Lamp Assembly G9 120V 25W
N/S 656-086 Light Glass Bracket
N/S 911-072 Replacement Bulb G9 120 Volt/25 watt
N/S 656-087 Light Rear Louver
N/S 656-088 Light Cover Plate
N/S 656-089 Light Deflector Shield
N/S 656-085 Gasket Light Cover Gasket
N/S 656-079 Top Glass Clamp Left (Each)
N/S 656-080 Top Glass Clamp Right (Each)
N/S 656-269 Lower Glass Clamp (Each)
N/S 656-052 Lower Glass Clamp Bracket (Each)
N/S 656-617 Pressure Relief Door Frame Assembly/Includes Gasket
Optional Accessories
11 656-926* Inner Panel Glass Black
11 656-927* Inner Panel Black (Painted)
11 656-928* Inner Panel Enamel Black
* Sold only as complete sets
N/S 656-202 Top Rear Panel Clip (Used on the 656-926)
N/S 656-203 Top Corner Bracket (Used on the 656-926)
N/S 656-205 Glass Panel Top Side Bracket (Used on the 656-926)
N/S 656-205 Lower Corner Glass Bracket (Used on the 656-926)
N/S 656-218 Rear Base Panel Bracket (Used on the 656-926)
N/S 656-291 Inner Top Panel Clip (Used on the 656-927)
N/S 656-059 Inner Top Panel Clip (Used on the 656-928)
N/S 656-930/P Driftwood Log Set
Page 70
parts list
N/S 656-969 Conversion Kit - LP
N/S 656-991 Chase Vent Front Black
N/S 656-995 Adaptor Heat Wave
N/S 946-556 Heatwave Kit
N/S 946-672 Stones - River Pebbles
N/S 946-674 Stones - Ceramic Spa (70 stones)
N/S 946-675 Fireglass Black Reflective 1/4in.1Lb Pkg
N/S 946-676 Fireglass Copper 1/4 in. 1Lb Pkg
N/S 946-677 Fireglass Starfire 1/4 in. 1Lb Pkg
N/S 946-775 Fireglass Black Reflective 1/4in.5Lb Pkg
N/S 946-776 Fireglass Copper 1/4 in. 5Lb Pkg
N/S 946-777 Fireglass Starfire 1/4 in. 5Lb Pkg
N/S 946-780 Crushed Glass Coal Black 3/4in. 3.5 Lbs
N/S 946-781 Crushed Glass Iceberg Chips 3/4in. 3.5 Lbs
N/S 946-735 Firebeads Black 1 Lb Pkg
N/S 946-736 Firebeads Sangria Luster 1 Lb Pkg
N/S 946-737 Firebeads Glacier Ice 1 Lb Pkg
N/S 946-738 Firebeads Caramel Luster 1 Lb Pkg
N/S 946-739 Firebeads Black 5 Lb Pkg
N/S 946-740 Firebeads Sangria Luster 5 Lb Pkg
N/S 946-741 Firebeads Glacier Ice 5 Lb Pkg
N/S 946-742 Firebeads Caramel Luster 5 Lb Pkg
N/S 946-710 Stones -Slate/Grey Basalt Natural 15 lbs
N/S 946-711 Stones - Ivory/Tan Basalt Natural 15 lbs
25
24
23
23
18
20
9
8
19
11
12
May not be exactly as shown
10
6a
22
7
1
2
6
4
5
17
70 | City Series
Page 71
notes
City Series | 71
Page 72
warranty
Indoor Gas Products
Supplier
Labor
Coverage
Warranty Coverage Parts and Labor
Firebox and Heat Exchanger
3
Steel Burner Tube
3
Glass Thermal breakage only
3
All Surrounds/Inlays Finishes
3
Brick Panels/Log sets/Ceramic Burners
All Castings
3
Valve assembly and all gas control
Thermocouple, Thermopile)
All Other Electrical
Pack, Remote Control Systems)
Enamel Panels
1
Venting/Venting Components
1
All Stainless steel surrounds
1
All Firebox Media (Crystals,
Ceramic & Spa Stones)
All hardware
 1
Mesh/Glass Safety Barriers
 1
Accent Light Bulbs
 1
Glass (Crazing)
 1
Limited Lifetime Warranty
FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U.S., Inc. (for U.S. customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
Some conditions apply (see below).
The policy is not transferable, amendable or negotiable under any circumstances.
Part
Lifetime 5 years 2 years 1 year Warranty (Years)
3
components, (Pilot assembly, flame sensors, Spark Electrode, Pilot Tubing, Orifices,
2
components,(Ignition Control Boards, Wiring, Switches, Blowers, Blower Control Module, Battery
Firebeads, Volcanic,
Conditions:
Warranty protects against defect in manufacture or FPI factory assembled components only, unless herein specified otherwise.
Any part(s) found to be defective during the warranty period as outlined above will be repaired or replaced at FPI’s option through an accredited distributor, dealer or pre-approved and assigned agent provided that the defective part is returned to the distributor, dealer or agent for inspection if requested by FPI. Alternatively, FPI may at its own discretion fully discharge all of its obligations under the warranty by refunding the verified purchase price of the product to the original purchaser. The purchase price must be confirmed by the original Bill of Sale.
The authorized selling dealer, or an alternative authorized FPI dealer if pre-approved by FPI, is responsible for all in-field diagnosis and service work related to all warranty claims. FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work.
Revision Date: December 2016 Regency Gas Products Warranty
2
1
72 | City Series
Page 73
At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty.
All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof of purchase by you). All claims must be complete and provide full details as requested by FPI to receive consideration for evaluation. Incomplete claims may be rejected.
Unit must be installed according to all manufacturers’ instructions as per the manual.
All Local and National required codes must be met.
The installer is responsible to ensure the unit is operating as designed at the time of installation.
The original purchaser is responsible for annual maintenance of the unit, as outlined in the owner’s manual. As outlined below, the warranty may be voided due to problems caused by lack of maintenance.
Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts
Exclusions:
This Limited Lifetime Warranty does not extend to paint, rust or corrosion of any kind due to a lack of maintenance or improper venting, combustion air provision, corrosive chemicals (i.e. chlorine, salt, air, etc.), door or glass gasketing.
Malfunction, damage or performance based issues as a result of environmental conditions, location, chemical damages, downdrafts, installation error, installation by an unqualified installer, incorrect chimney components (including but not limited to cap size or type), operator error, abuse, misuse, use of improper fuels , lack of regular maintenance and upkeep, acts of God, weather related problems from hurricanes, tornados, earthquakes, floods, lightning strikes/bolts or acts of terrorism or war, which result in malfunction of the appliance are not covered under the terms of this Limited Lifetime Warranty.
FPI has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications or upgrades will not be performed on existing appliances).
This warranty does not cover dealer travel costs for diagnostic or service work. All labor rates paid to authorized dealers are subsidized, pre-determined rates. Dealers may charge homeowner for travel and additional time beyond their subsidy.
Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty. This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within three (3) months of installation/purchase.
Units which show evidence of being operated while damaged, or with problems known to the purchaser and causing further damages will void this warranty.
Units where the serial no. has been altered, deleted, removed or made illegible will void this warranty.
Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this warranty.
Freight damages for products or parts are not covered under the terms of the warranty.
Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty.
warranty
Revision Date: December 2016 Regency Gas Products Warranty
City Series | 73
Page 74
warranty
Canadian Warrantor:
Canada, V4G 1H4
U.S. Warrantor:
United States, 98231
Limitations of Liability:
The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL DAMAGES OR DAMAGES TO PROPERTY. TO THE EXTENT PERMITTED BY APPLICABLE LAW, FPI MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED, THEN SUCH WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some U.S. states do not allow limitations on how long an implied warranty lasts, or allow exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
Customers located outside the U.S. should consult their local, provincial or national legal codes for additional terms which may be applicable to this warranty.
How to Obtain Warranty Service:
Customers should contact the authorized selling dealer to obtain warranty service. In the event the authorized selling dealer is unable to provide warranty service, please contact FPI by mail at the address listed below. Please include a brief description of the problem and your address, email and telephone contact information. A representative will contact you to make arrangements for an inspection and/or warranty service.
FPI Fireplace Products International Ltd. 6988 Venture St. Delta, British Columbia
Fireplace Products U.S., Inc. PO Box 2189 PMB 125 Blaine, WA
Or contact the Regency Customer Care Centre at 1-800-442-7432 (phone) / 604-946-4349 (fax)
Product Registration and Customer Support:
Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx within ninety (90) days of purchase.
Revision Date: December 2016 Regency Gas Products Warranty
74 | City Series
Page 75
Product Registration and Customer Support:
Warranty Details
Serial Number (required):
Purchase Date (required) (mm/dd/yyyy):
Product Details
Product Model (required):
Dealer Details
Dealer Name (required):
Dealer Address:
Dealer Phone #:
Installer:
Date Installed (mm/dd/yyyy):
Your Contact Details (required)
Name:
Address:
Phone:
Email:
For purchases made in CANADA:
Canada, V4G 1H4
For purchases made in the UNITED STATES:
Fax: 604-946-4349
Fax: 604-946-4349
Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
For purchases made in CANADA or the UNITED STATES:
http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx
For purchases made in AUSTRALIA:
http://www.regency-fire.com.au/Customer-Care/Warranty-Registration.aspx
You may also complete the warranty registration form below to register your Regency Fireplace Product and mail and/or fax it back to us, and we will register the warranty for you. It is important you provide us with all the information below in order for us to serve you better.
Warranty Registration Form (or Register online immediately at the above Web Site):
warranty
FPI Fireplace Products International Ltd.
6988 Venture St. Delta, British Columbia
Phone: 604-946-5155
Fireplace Products U.S., Inc. PO Box 2189 PMB 125 Blaine, WA United States, 98231
Phone: 604-946-5155
For fireplace care and tips and answers to most common questions please visit our Customer Care section on our Web Site. Please feel free to contact your selling dealer if you have any questions about your Regency product.
City Series | 75
For purchases made in AUSTRALIA:
Fireplace Products Australia Pty Ltd
1- 3 Conquest Way Hallam, VIC Australia, 3803
Phone: +61 3 9799 7277 Fax: +61 3 9799 7822
Page 76
76 | City Series
Page 77
notes
City Series | 77
Page 78
notes
78 | City Series
Page 79
Page 80
Installer: Please complete the following information
Dealer Name & Address: ______________________________________________
___________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.: __________________________________________________________
© Copyright 2017, FPI Fireplace Products International Ltd. All rights reserved.