Classic C33 model shown above features
optional gold plated door and gold legs.
MODELS: C33-NG3 Natural Gas C33-LP3 Propane
WARNING:
If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas sup-
plier, call the fi re department.
918-511
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
11/08/07
To the New Owner:
Congratulations! You are the owner of a state-of-the-art Gas Stove by Fireplace Products International
Ltd. The Regency® Gas Series of hand crafted appliances has been designed to provide you with all the
warmth and charm of a woodstove, at the fl ick of a switch. The models C33-NG3 and C33-LP3 have been
approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to
provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your CLASSIC Freestanding
Gas Stove.
2
Regency
®
CLASSIC C33-3 Freestanding Gas Stove
TABLE OF CONTENTS
SAFETY LABEL
Serial No. Decal ............................................................4
REQUIREMENTS
MA Code - CO Detector
(for state of Massachusetts only) ..................................5
INSTALLATION
Before You Start ............................................................6
Important Message ........................................................6
General Safety Information ...........................................6
This is a copy of the label that accompanies each
CLASSIC Freestanding Gas Stove - Natural Gas and Propane. We have printed a copy of
the contents here for your review. The safety
label is located on the back panel.
®
NOTE: Regency
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
units are constantly being
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appliances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
4
Regency
®
CLASSIC C33-3 Freestanding Gas Stove
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and
detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of
the installation.
Regency® CLASSIC C33-3 Freestanding Gas Stove5
INSTALLATION
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
INSTALLATION AND REPAIR
SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE
APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT
LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING,
BEDDING MATERIAL, ETC. IT IS
IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE
BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE
LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND
DRAPERIES.
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
MAY CAUSE A SERIOUS HOUSE
FIRE AND WILL VOID YOUR WARRANTY.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD
STAY AWAY TO AVOID BURNS OR
CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM
AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.
IMPORTANT MESSAGE
The CLASSIC Freestanding Gas Stove must be
installed in accordance with these instructions.
Carefully read all the instructions in this manual
fi rst. Consult the "authority having jurisdiction" to
determine the need for a permit prior to starting
the installation.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform
with local codes or, in the absence of local
codes, with the current Canadian or National
Gas Codes, CAN1-B149 or ANSI Z223.1
Installation Codes.
2) The appliance when installed, must be
electrically grounded in accordance with
local codes, or in the absence of local codes
with the current National Electrical Code,
ANSI/NFPA 70 or CSA C22.1 Canadian
Electrical Code.
3) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
4) This appliance is Listed for Alcove instal-
lations, maintain minimum Alcove clearances as follows, minimum ceiling height
of 65-11/16", minimum width of 48" and a
maximum depth of 36".
5) This unit is not approved for installation into
a mobile home.
6) See general construction and assembly
instructions.
7) This appliance must be connected to a vent
and terminate to the outside of the building
envelope. Never vent to another room or
inside a building.
8) Inspect the venting system annually for
blockage and any signs of deterioration.
9) Any safety glass removed for servicing
must be replaced prior to operating the appliance.
10) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fi replace.
11) Wear gloves and safety glasses for protec-
tion while doing required maintenance.
12) Under no circumstances should this ap-
pliance be modifi ed. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.
13) Installation and any repairs to this appliance
should be done by a qualifi ed service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.
14) Do not strike the glass door.
15) Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
16) The appliance area must be kept clear and
free of combustible materials, (gases and other
fl ammable vapours and liquids).
Emissions from burning wood or gas could
contain chemicals known to the State of California to cause cancer, birth defects or other
reproductive harm.
INSTALLATION
CHECKLIST
1) Locate appliance. Refer to the "Clearance to
Combustible" section.
2) Install Optional Fan. Refer to the "Optional Fan
Installation" section.
3) Assemble stove base - pedestal or legs. Refer
to "Pedestal Assembly" or "Leg and Bottom
Shield Assembly" section.
4) If using outside air. Refer to the "Optional
Outside Air" section.
5) Install venting. Refer to the "Venting" section.
6) Make gas and electrical connections. Refer to
the "Gas Connection" section.
Test the pilot. Must be as per diagram in the
"Pilot Adjustment" section.
7) Test gas pressure. Refer to the "Gas Pipe Pres-
sure Testing" section.
8) Test for fl ue spillage. Refer to the "Test for Fuel
Spillage" section.
9) Install standard and optional features. Refer to
the following sections where applicable:
a. Log Set Installation
b. Remote Control
c. Remote Wall Switch
d. Wall Thermostat
11) Final check. Refer to the "Final Check" sec-
tion.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring correctly and operation fully explained to customer.
6
Regency
®
CLASSIC C33-3 Freestanding Gas Stove
INSTALLATION
This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to
ensure that the fl ame does not carbon.
First allow the unit to burn for 15-20 min.
to stabilize.
3) Check for proper draft.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
CLEARANCES TO
COMBUSTIBLES
The clearances listed below are MINIMUM
distances. Measure the clearance to both the
appliance and the chimney connector. The farthest distance is correct if the two clearances do
not coincide. For example, if the appliance is set
as indicated in one of the diagrams but the back
wall is too close, move the stove until the correct
clearance to the back wall is obtained.
This unit can be installed on a solid combustible
surface like a wood fl oor. This unit can also be
installed directly on carpeting or vinyl when the
bottom pedestal cover plate (provided with the
unit) is installed.
OPTIONAL FAN
INSTALLATION
Important: Disconnect the power
supply before installation or servicing.
For pedestal unit: To install the fan in an in-
stalled stove-access from front through the
pedestal by following the directions below.
If the stove is not installed - access through
rear and follow steps 4 to 17.
For leg unit: remove 7 screws, remove bottom
access panel and install fan assembly and
follow steps 4 to 17.
1) Open pedestal door and remove door cover
plate by removing 4 screws. See diagram
1.
4) Screw the four 8-32 x 3/4 screws provided
into the nutserts as shown in diagram 3. Do
not tighten screws.
5) Push all the fan wires through the hole on
the fan assembly. See diagram 2
.
6) Put power cord (shown in diagram 3) through
the hole and pull through to front of unit for
easier installation of ground wire.
7) Place fan assembly partially in door cover
plate hole. See diagram 2.
8) Attach the 2 ground wires (green) to the
ground lug as per diagram 2.
Note:Ground lug is located on the bottom of the
fan assembly. See diagram 2.
This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type of
installation with another in order to achieve
closer clearances. Use the minimum clearances
shown in the diagrams. Alcove installations are
approved, as long as side wall clearances are
maintained.
C33-3 Clearances to Combustibles
A Side Wall to Unit 10" / 250 mm
B Back Wall to Unit 6" / 150 mm
E Side Wall to Unit 1.5" / 38 mm
C33-3 Reference Dimensions
to Flue Centerline
C Back Wall 11-1/2"/ 292 mm
D Side Wall 22" / 559 mm
F Side Wall 13" / 330 mm
Minimum ceiling height is 36" / 914 mm from
Diagram 3
9) Lift the fan assembly in through the pedestal
and up through the cut out as shown in
diagrams 3 and 4.
10) Put the insulation gasket on the back of
the fan. Line up the keyhole slots with the
matching screws and pull back slightly to
lock into place. While holding fan assembly
in place, tighten screws.
Diagram 1
2) Remove valve cover plate by removing 2
screws.
3) Remove wire from piezo ignitor.
Diagram 4
Diagram 2
Regency® CLASSIC C33-3 Freestanding Gas Stove7
INSTALLATION
Wiring
11) Remove the dummy plug from the right side
of the bottom shield or pedestal and install
the supplied fan switch.
12) Attach hot wire from power cord to the ther-
modisc.
13) Slide the thermodisc under the bracket.
16) Pull power wire back and put strain relief
grommet in place as per diagram 4.
17) Reverse steps 3-1 to complete installa-
tion.
Note: The #8 ground lug is a dedicated
ground for mobile home use only.
Only C34 unit is approved for mobile
homes.
Caution: Ensure that wires do
NOT touch hot surfaces.
Fan Removal
1) Disconnect the power to fan.
2) Allow the stove to cool to room tempera-
ture.
3) Open the pedestal door and remove the
screws on the door cover plate. Leg Units:
Remove bottom access panel.
4) Loosen the nutsert screws.
5) Remove Fan Assembly from the key slots
at the fan base. Take the fan out from the
rectangular opening . Diagram 3.
PEDESTAL ASSEMBLY
1) For easier assembly, tip the stove on its back
(preferably onto a soft surface to prevent
scratching).
2) Unscrew the 4 bolts in the underside of the
stove. Align the holes in the corners of the
pedestal top with the corresponding holes in
the base of the stove. Use washers which
are supplied with the pedestal as shown in
diagram. Reinstall bolts.
View from Bottom of Stove
14) Connecting wires to the 3 way switch -
a. Connect the red wire from the fan to the
top of the 3 way switch.
b. Connect black wire from fan to the bottom
of the 3 way switch.
c. Connect white jumper wire to middle of
the three way switch. See wiring diagram
below.
15) Connect white wire from fan motor to neutral
on the power cord.
6) Turn the fan around 90 degrees (Pedestal
units only). Diagram 2.
7) Disconnect the green ground wires to the
grounding lug.
8) Disconnect the white wire of the fan from
the power cord.
9) Disconnect red wire and black wire (from
fan to Fan Switch).
10) Take fan out from the stove body. Diagram
Diagram 1
3) Hook up wires to Burner ON/OFF switch
and valve assembly (be careful not to pinch
wires). See Diagram 1.
4) Push the Regency® logo into the two holes
in the front bottom left corner of the pedestal
cover plate.
Note: Any paint touch up should be done
prior to placing logo on pedestal.
Wiring Diagram
8
Regency
®
CLASSIC C33-3 Freestanding Gas Stove
INSTALLATION
LEG AND BOTTOM
SHIELD ASSEMBLY
These instructions apply to the steel leg, painted
cast leg and the gold plated cast leg. It will be
easier to attach the legs to the stove if it is
tipped on its back (preferably on a soft surface
to prevent scratching).
1) Remove the 4 bolts in the underside of the
base and discard.
2) Put the bottom shield up against the bottom
of the stove and loosely install the four supplied bolts and washers into the threaded
holes in the four corners of the bottom the
unit. Once the bolts are started, slip the leg
under the washer and tighten the bolts.
3) Hook up wires to Burner ON/OFF switch and
valve assembly as per pedestal assembly
diagram (diagram 1).
4) Level the stove by adjusting the levelling
bolts in the bottom of each leg.
OPTIONAL
OUTSIDE AIR
If needed, outside air for combustion can be
brought in either through the bottom of the pedestal or through the rear plate of the pedestal.
The pedestal cover plate must be installed when
using outside combustion air. Loosen the 4
screws on the rear of the pedestal and slide the
cover plate over them. Slide the plate to the left
to center it and tighten down the 4 screws.
Outside Air Through
Pedestal Bottom
Once you have properly marked the position
of your unit as outlined in "General Information" and "Clearances to Combustibles", cut a
minimum 3 inch diameter hole though the fl oor
directly under your pedestal base to the outside.
Pipe fresh air into the pedestal area by using a
minimum 3" duct pipe with a mesh grill at the
outside termination.
Note: Blanking plate combustion air hole is
4" diameter.
IMPORTANT
Read all instructions carefully before starting
the installation. Failure to follow these instructions may create a fi re or other safety hazard,
and will void the warranty. Be sure to check the
venting and clearance to combustible requirements. Consult your local building codes before
beginning installation.
DRAFT HOOD
The heater has a draft hood built into its back.
It must not be altered or obstructed, and the
unit must be installed so that the draft hood is
in the same atmospheric pressure zone as the
combustion air inlet to the burner.
VENTING
This heater is a vented appliance and must be
connected to a chimney/fl ue in accordance with
installation codes.
Note: The rear cover plate is only attached
when outside air is being used. Do
not install it when using room air for
combustion.
Rear View
Outside Air Through
Pedestal Rear
Remove the blanking plate from the rear of the
pedestal cover plate and bend the two tabs out
90 degrees. Pipe fresh air into the pedestal area
by using a minimum 3" duct pipe with a mesh
grill at the outside termination. Attach the pipe
to the tabs with screws.
Note: The hole in the rear pedestal cover
plate is 4" diameter.
For your safety this heater is equipped with a
vent safety switch. This thermally actuated switch
is located within the draft hood and will detect
either a blocked chimney or backdraft condition
where the chimney fl ow has reversed and will
react by shutting off the gas supply.
Note: The spill switch is manually resettable
and comes from the factory in the
open position. Before trying to start
up the unit, make sure the red button
on the spill switch is pushed in.
Venting Requirements
Four inch diameter vent is required. B-Vent,
Class A or Masonry with a liner are all acceptable.
Follow all venting manufacturer’s requirements
and local building codes. For altitudes above
2000 ft. we recommend that a minimum fl ue
height of 12 ft. is used.
Note: Proper sizing of gas vents is critical
to proper operation of all gas stoves
and fi replaces. Ensure that proper
sizing tables or vent manufacturers
instructions are followed.
Side View
Regency® CLASSIC C33-3 Freestanding Gas Stove9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.