Regency B36X User Manual

Regency Bellavista
B36X
Owners &
Installation Manual
Gas Fireplace
MODEL: B36X
Medium DV Gas Fireplace
www.regency-fi re.com
WARNING:
If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
918-759
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FOR YOUR SAFETY
What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch:
do not use any phone in your building.
Immediately call your gas supplier
from a neighbour's phone. Follow the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
02/05/09
To the New Owner:
Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The Bellavista™ B36X has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The Bellavista™ B36X has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency®
Fireplace.
MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regency® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88a-2007 / CSA 2.33a-2007 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes.
This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Ensure that structural members are not cut or weakened during installation.
2
Regency Bellavista™ B36X Gas Fireplace
TABLE OF CONTENTS
SAFETY LABEL
Copy of Safety Decal .....................................................4
REQUIREMENTS
MA Code - CO Detector.................................................5
DIMENSIONS
Unit Dimensions ............................................................6
INSTALLATION
Important Message ......................................................7
Before You Start ............................................................7
General Safety Information............................................7
Installation Checklist .....................................................8
Locating Your Gas Fireplace .........................................8
Heatwave Duct System (Optional) ...............................8
Clearances ....................................................................9
Mantel Leg Clearances................................................10
Mantel Clearances.......................................................10
Framing ......................................................................11
Finishing ......................................................................12
Unit Assembly Prior to Installation ...............................13
Top Standoff Assembly ........................................13
Top Facing Support ..............................................13
Side Nailing Strips ...............................................13
Top Flue Collar Installation ..................................14
Venting Introduction .....................................................15
Exterior Vent Termination Requirements .....................16
Approved Venting Confi gurations ................................17
Rigid Pipe Cross Reference Chart ..............................19
4" X 6-5/8" ...........................................................19
5" X 8" ................................................................21
Horizontal Terminations ...............................................23
Regency® Direct Vent Flex System (5" x 8") ........23
Rigid Pipe venting arrangements (5" x 8") ...........24
Rigid Pipe Venting Systems .................................25
HORIZONTAL 5” x 8” rigid rear vent kit ....................... 26
for corner installations .................................................26
Venting Arrangements ................................................27
4" x 6 - 5/8" pipe venting arrangements ...............27
Venting Arrangements Horizontal Termination ....28
Horizontal Venting with Two (2) 90o Elbows ................28
Vertical Venting with Three (3) 90o Elbows ..................29
Vertical Termination With Co-linear Flex System .........30
Venting Arrangement - Vertical Terminations ..............31
Unit Installation with Horizontal Termination ................ 33
Unit installation with Vertical Termination ....................34
Gas Line Installation .................................................... 34
Pilot Adjustment ........................................................... 35
High Elevation .............................................................35
Gas Pipe Pressure Testing ..........................................35
S.I.T. Valve Description ................................................35
Aeration Adjustment ....................................................36
Wiring Diagram ............................................................36
Wiring diagram for GTMF remote ................................37
Vent Restrictor, Baffl e & Heat Defl ector Installation ....38
Conversion from NG to LP ..........................................39
DC Sparker Installation................................................41
Brick panel installation .................................................42
Optional Stainless Steel / Black Enamel .....................43
Panel Installation .........................................................43
Log Set installation ......................................................45
Optional Wall Thermostat ...........................................48
Optional Remote Control ............................................. 48
Wall Switch (Included) .................................................48
Fan Installation ............................................................ 50
Flush glass door Installation ........................................ 51
Optional Finishing Trim Installation..............................52
Flush Louvers and Flush Panel Installation .................52
Full Screen Arch Door and Frame Installation .............53
OPERATING INSTRUCTIONS
Operating Instructions .................................................54
First Fire ......................................................................54
Lighting Procedure ......................................................54
Shutdown Procedure ................................................... 54
Normal Operating Sounds Of Gas Appliances ............ 54
Copy of Lighting Plate Instructions .............................. 55
Maintenance Instructions.............................................56
Log Replacement ........................................................56
Thermopile / Thermocouple .........................................56
Door Glass...................................................................56
Removing Valve ...........................................................57
Installing Valve .............................................................57
PARTS LIST
Main Assembly ............................................................58
Burner Assembly .........................................................60
WARRANTY
The Warranty: Limited Lifetime ...................................64
Regency Bellavista™ B36X Gas Fireplace
3
SAFETY LABEL
This is a copy of the label that accompanies each Bellavista™ B36X Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
NOTE: Regency improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
®
units are constantly being
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli­ances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.
COPY OF SAFETY DECAL
4
Regency Bellavista™ B36X Gas Fireplace
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
Regency Bellavista™ B36X Gas Fireplace
5
DIMENSIONS
33” (838mm)
UNIT DIMENSIONS
21”(533mm)
30-3/8” (762mm)
35-1/4”
(895mm)
39-1/16”
(992mm)
37-1/2” (953mm)
17-5/16” (440mm)
20-1/4” (514mm)
1”(25.4mm)
36” (914mm)
33-1/16” (840mm)
35-1/4” (895mm)
26-1/2” (673mm)
19-5/16” (490mm)
6
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The Bellavista™ B36X Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturers instructions and all applicable codes.
BEFORE YOU START
Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE­CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform
with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.
2) The appliance when installed, must be
electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.
3) See general construction and assembly
instructions. The appliance and vent should be enclosed.
4) This appliance must be connected to the
specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.
5) Inspect the venting system annually for
blockage and any signs of deterioration.
6) Venting terminals shall not be recessed into
a wall or siding.
7) Any safety glass removed for servicing
must be replaced prior to operating the appliance.
8) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the replace.
9) Wear gloves and safety glasses for protection
while doing required maintenance.
10) Be aware of electrical wiring locations in
walls and ceilings when cutting holes for termination.
11) Under no circumstances should this appliance
be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.
12) Installation and any repairs to this appliance
should be done by a qualifi ed service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.
15) The appliance area must be kept clear and
free of combustible materials, (gases and other fl ammable vapours and liquids).
Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
Regency Bellavista™ B36X Gas Fireplace
7
INSTALLATION
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location (Refer to "Locating Your
Gas fi replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantel Clearances (Refer to "Combustible
Mantel Clearances" section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2) Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips (Refer to "Unit Assembly Prior to Installation" Section). NOTE: Must be done before installing unit into place.
3) Install vent (Refer to "Venting" sections).
4) Make gas and electrical connections. Test
the pilot. Must be as per diagram (Refer to "Pilot Adjustment " section).
Convert to propane if desired (Refer to "Gas
Line Installation" and "Conversion Kit from NG to LPG" sections).
5) Install standard and optional features. Refer
to the following sections:
a. LP Conversion Kit (Optional) b. Brick Panels (Optional) c. Log Set Installation d. Standard Flush Door e. Full Screen Door (Optional) f. Flush Panel/Louver (Optional) g. Remote control,Wall Switch or
Thermostat (Optional)
h. Fan Installation (Optional)
6) Final check.
This includes:
1) Clocking the appliance to ensure the correct
ring rate (rate noted on label) after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your replace,
ensure that the clearances are met.
2) The appliance must be installed on a fl at,
solid, continuous surface For example a wood, metal or concrete fl oor or in a raised (on the wall) application. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.
3) The B36X Bellavista™ Gas Fireplace can
be installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.
Diagram 1
4) This appliance is Listed for bedroom
installations using the standard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.
5) The B36X Gas Fireplace are approved for
alcove installations, see "Clearances" section for details.
6) We recommend that you plan your installation
on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.
Note: For vent terminations refer to
"Exterior Vent Termination Locations" section.
HEATWAVE
DUCT SYSTEM
(OPTIONAL)
#946-556
The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home.
Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time. This includes the internal blower option as well.
A) Flat on Wall B) Flat on Wall Corner C) Recessed into Wall/Alcove D) Corner
8
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions.
The top, back and sides of the fi replace are defi ned by
standoffs. The metal ends of the standoff may NOT be
Caution Requirements
recessed into combustible construction.
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fi replace and vent
system be installed only in accordance with these instructions.
B36X Clearance Requirements
Clearance: Dimension Measured From:
A: Mantel Height (min.) 6-1/2" (165mm) Top of Fireplace Opening
B: Sidewall 12" (304mm) on one side Side of Fireplace Opening
C: Ceiling 36-34" (933mm) Top of Fireplace Opening
D: Mantel Depth 12" (304mm) 14-1/2 " (368mm) from
E: Alcove Width 84" (2134mm) Sidewall to Sidewall (Minimum)
F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum)
Notes: 0" No Hearth Required
Top of Fireplace Opening
Fire hazard is an extreme risk
WARNING
Minimum Vent Clearances
to Combustibles
Horizontal Top 2" (51mm)
Horizontal Side 1-1/2 " (38mm)
Horizontal Bottom 1-1/2" (38mm)
Vertical Vent 1-1/2" (38mm)
Regency Bellavista™ B36X Gas Fireplace
9
INSTALLATION
MANTEL CLEARANCES
Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing
are shown in the diagram on the right.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-
combustible board.
Mantel Clearances
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the paint may discolour.
12
14
12
12”
6
810
4
7”
2
0
Combustible
Mantel Clearances B36X
From Top of Fireplace Opening
6
B
0
Inches
To Floor
ABCD
32"
(813mm)
14-1/2"
(368mm)
11"
(279mm)
6-1/2"
(165mm)
MANTEL LEG CLEARANCES
12” Side Wall
(Measured from side of
Fireplace Opening)
A
C
To p o f
Fireplace
Opening
1"
D
Top Header
Standoff
Side View
10
Top View
Mantel leg
1-1/2"
2"
5"
Allowable mantel leg
projection.
Mantel leg
3"
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
FRAMING
Framing Dimensions Description B36X
M Framing Width 36 - 1/4"(921mm)
N Framing Height 39 - 3/8" (1000mm)
O (Rear Vent) Framing Depth - Rear Vent 20 - 3/4" (527mm)
O (Top Vent) Framing Depth - Top Vent 19 - 1/2" (495mm)
P (Top Vent) Corner Facing Wall Depth 48 - 5/8" (1235mm)
P (Rear Vent) Corner Facing Wall Depth 53" (1346mm) AstroCapXL
Q (Top Vent) Corner Facing Wall Width 68 - 3/4" (1746mm)
Q (Rear Vent) Corner Facing Wall Width 75" (1905mm) AstroCapXL
R (Rear Vent) Framed Chase Ceiling - Rear 39 - 3/8" (1000mm)
R (Top Vent) Framed Chase Ceiling - Top 50-1/2" (1282mm)
S (Rear Vent) Vent Centerline Height - Rear 26-1/2" (673mm)
S (Top Vent) Vent Centerline Height - Top 44-1/4" (1123mm) Rigid
T Gas Connection Height 1-1/2" (38mm)
U Gas Connection Inset 4-1/8" (105mm)
V Gas Connection Width 3-1/4" (82mm)
W Non-Combustible Top Height 0"
61-1/2" (1562mm) - other approved caps
87" (2209mm) - other approved caps
42-1/8" (1070mm) Flex
N
M
R
Drywall
(or other
facing)
Top Header
Combustible Facing
11" (279mm)
dia. Hole through
wall Vent.
O
S
S
P
T
U
Q
Note: If installing the unit into a corner and rear venting - use AstroCapXL 946-623/P to obtain closest clearance.
Regency Bellavista™ B36X Gas Fireplace
Opening for gas
V
connection
11
INSTALLATION
FINISHING
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into fi nal position - it is important to know the total thickness / height of fi nished hearth (tile, carpet, etc.) The base of the replace should be level or higher than the fi nished hearth height.
Diagram 1
Note: All facing material should butt up cleanly to the fl anges
around the fi rebox opening.
Rough edges will be visible from the front view with the fl ush
louvers or fl ush panels - if not using the fi nishing trim.
To maintain a clean fi nished edge - it is recommended to install
the drywall or other facing material with the fi nished edge against the fi replace / nailing strips.
Alternatively, you can use J Style Trim or Metal Corner Bead to cover cut edges of the facing material.
Important:
Finishing materials such as tile, river rock, etc, must not protrude
beyond the front facing fl anges the sides and top of the fi rebox opening.
Full Screen Doors Only:
If fi nishing with any material thicker than 1-1/4" - a 3/4" gap must
be maintained between the full screen doors and the fi nishing material.
This gap is necessary to facilitate the installation and removal of
the full screen doors.
Diagram 3
3/4"
Finishing material - thicker
than 1-1/4"
Full Screen
Door
12
Diagram 2
Diagram 4
1"
There is a 1" air space between the unit and full screen door
Note:
which must not be covered.
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
UNIT ASSEMBLY PRIOR TO INSTALLATION
BEFORE YOU START
The Top Facing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the fi replace is moved into position.
TOP STANDOFF ASSEMBLY
The top standoffs are shipped in a fl at position and must be folded into shape and attached.
1) Remove the standoffs from the fi replace top.
2) Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the pre-punched screw holes on the fi replace top line up.
3) Attach the standoff securely to the top with 2 screws per standoff (on opposite corners).
Determine the total thickness of facing material (e.g. drywall or wood plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.
Screw Facing Material
The Top Facing Support can be mounted in 3 different positions depending on the thickness of the facing material.
Position Depth
A 1/2" / 13mm B 7/8" / 22mm C* 1-1/4" / 32mm
* For "C" screw position the top facing support is reversed.
1) Mount Top Facing Support using the 3 supplied screws into the three pre-punched screw holes on the top front of the unit. Use hole positions A, B, or C depending on your facing depth.
Top Facing
TOP FACING SUPPORT
Support
Top Facing Support
Screw holes for
Top Facing
Support
C
B
A
SIDE NAILING STRIPS
The side nailing strips come attached to the unit. There are 2 plates, one on the top and bottom that can be folded out as required.
Plates can be
folded out.
Top Facing Support
is reversed
for “C” hole position
C
B
A
Regency Bellavista™ B36X Gas Fireplace
"C" Screw Position:
For a facing material depth of 1-1/4" (32mm), the top facing support must be reversed.
13
INSTALLATION
UNIT ASSEMBLY PRIOR TO INSTALLATION
TOP FLUE COLLAR INSTALLATION
The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented.
1 Intake Collar Assembly with Gasket
1 Intake Collar Plate with Gasket
1 Top/Rear Exhaust Assembly with Gasket
1 Heat Defl ector
1 Baffl e Plate
29 1/4" x 1/2" Screws (4 spares)
1 Restrictor
1 Intake Collar Gasket (spare)
1 Exhaust Assembly Gasket (spare)
1. Remove the door assembly by releasing the adjustable latches and lifting up off the door frame assembly.
Note: This conversion must be done prior to the unit being placed in position.
Top Collar Assembly Kit
Exhaust Assembly
w/ gasket
Intake Collar Plate
w/gasket
Intake Collar Assembly
w/gasket
Adjustable Tension
Latch location
2) From inside the rebox, remove the top heat defl ector by removing
2 - 1/4" x 1/2" screws.
Heat Defl ector
3) From inside the rebox, remove the baffl e plate by removing 4 - 1/4"
x 1/2 " screws. See Diagram 3
Baffl e Plate
14
Diagram 2
Diagram 3
Diagram 1
4) From the inside of the rebox, remove the exhaust assembly by
removing the 8 - 1/4" x 1/2" screws. See Diagram 4.
Diagram 4
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
5) From the outside rear of the fi rebox, remove the intake collar
assembly. Remove the 4 - 1/4" x 1/2" screws. See Diagram 5.
Exhaust
Assembly
Intake Collar
Assembly
Diagram 5
6) From the outside top of the rebox, remove the intake collar plate
by removing the 4 - 1/4" x 1/2 " screws. See Diagram 6.
8) From the outside top of the rebox, install the intake collar assembly.
Secure with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten. All 4 screws must be used.
Exhaust
Assembly
Diagram 9
9) From the outside rear of the rebox, install the intake collar plate
with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten. All 4 screws must be used.
Intake Collar
Assembly
Diagram 6
Before proceeding to Step 7, inspect condition of all gaskets. DO NOT install parts with damaged gaskets. Replace if necessary
with spare gaskets supplied.
7) From the inside of the rebox, place the exhaust assembly into position as shown in Diagram 7 and secure with 8 - 1/4" x 1/2" screws (Diagram 8). Ensure all screws are tight, but do not over tighten.
All 8 screws must be used.
Diagram 7
Diagram 10
10) From inside the rebox, re-install the baffl e plate and heat defl ector - reverse steps 2 & 3.
VENTING
INTRODUCTION
The B36X uses the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
Note: These fl ue pipes must not be connected to any other
appliance.
The gas appliance and vent system must be vented directly to the
outside of the building, and never be attached to a chimney serving
a separate solid fuel or gas burning appliance. Each direct vent gas
appliance must use it's own separate vent system. Common vent
systems are prohibited.
Diagram 8
Regency Bellavista™ B36X Gas Fireplace
15
INSTALLATION
EXTERIOR VENT TERMINATION REQUIREMENTS
1
Minimum Clearance Requirements
A Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm)
B Clearance to window or door that may be opened 12"(30cm) 9" (23cm)
C Clearance to permanently closed window **
D Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm) 24"(60cm) 24"(60cm)
E Clearance to unventilated soffi t 12"(30cm) 12"(30cm)
F Clearance to outside corner: with AstroCap Termination Cap. 13"(33cm) 13"(33cm)
Clearance to outside corner: with all other approved Termination Caps. 13"(33cm) 13"(33cm)
G Clearance to inside corner: with AstroCap Termination Cap 6"(15cm) 6"(15cm)
Clearance to inside corner: with all other approved Termination Caps. 6"(15cm) 6"(15cm)
H Clearance to each side of center line extended above meter/regulator assembly 36"(90cm)
J Clearance to service regulator vent outlet 36"(90cm) *
K Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 12"(30cm) 9" (23cm)
L Clearance to a mechanical air supply inlet 72"(1.8m) 36"(90cm)
M Clearance above paved sidewalk or a paved driveway located on public property 84"(2.1m)
N Clearance under veranda, porch, deck, or balcony 12"(30cm)
1
In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor
Clearance in accordance with local installation codes and the requirements of the gas supplier
*
a
3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b
3 feet (91cm) above - if within 10 feet (3m) horizontally
Canada
a
USA
*
*
*
2
b
16
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
APPROVED VENTING CONFIGURATIONS
HORIZONTAL & VERTICAL TERMINATIONS
Regency Bellavista™ B36X Gas Fireplace
17
INSTALLATION
APPROVED VENTING CONFIGURATIONS
HORIZONTAL & VERTICAL TERMINATIONS
Vertical Venting Configurations
Vertical Rear Vent Flex Vent 4" x 6-5/8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Rear Vent Flex Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Rear Vent Rigid Vent 4" x 6-5/8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Rear Vent Rigid Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Top Vent Flex Vent 4" x 6-5/8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Top Vent Flex Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Top Vent Rigid Vent 4" x 6-5/8" • Min. 8 ft vertical run
• Max. 35.5 ft vertical run
• Up to 2 x 90o elbows
• See manual for details
Various applications See manual for details
Rigid Pipe Adaptor
Vent Reducer
770-994
946-606
Vertical Top Vent Rigid Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved
18
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
RIGID PIPE CROSS REFERENCE CHART
4" X 6-5/8"
(MUST USE VENT REDUCER # 946-606 AND RIGID PIPE ADAPTOR #770-994)
Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI.
Regency Bellavista™ B36X Gas Fireplace
19
INSTALLATION
20
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
RIGID PIPE CROSS REFERENCE CHART
5" X 8"
Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI.
Regency Bellavista™ B36X Gas Fireplace
21
INSTALLATION
22
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
HORIZONTAL TERMINATIONS
®
REGENCY
These venting systems, in combination with the B36X Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section.
Regency® Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615) includes all the parts needed to install the B36X with a either a top or rear vent.
1) 8" dia. exible liner (4 ft. length)
2) 5" dia. exible liner (4 ft. length)
3) spring spacers (4)
4) thimble
5) AstroCapXL termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point,
Stainless Steel (4)
10) vinyl siding standoff
DIRECT VENT FLEX SYSTEM (5" X 8")
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from FPI may be used for Flex installations.
Note: If longer runs are required - rigid pipe must be used.
Regency Bellavista™ B36X Gas Fireplace
23
INSTALLATION
RIGID PIPE VENTING ARRANGEMENTS (5" X 8")
Standoff (Optional)
Pipe Length
o
90 Elbow
Rigid Pipe Adaptor
A
HORIZONTAL TERMINATIONS
Vinyl Siding
Horizontal
Termination
Cap
Wall Thimble
Horizontal Termination
A Top Vent - No Vertical Rise
• When venting with a 90° elbow directly off the unit, must use 5" X 8" Astrocap™ Flex vent or approved Rigid Vent System
• Max. 3 ft. horizontal run
B Rear Vent w/ Horizontal Termination
• Can only use 5" x 8" venting
• Max. 3ft. horizontal run
Vinyl Siding
Standoff (Optional)
Pipe Length
Rigid Pipe Adaptor
B
Wall Thimble
Horizontal
Termination
Cap
The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.
For horizontal terminations the Regency Direct Vent Flex System (see page 14) may be used for installations with a maximum continuous vent length of 3ft (0.9m).
Note: Must use optional rigid pipe adaptor (Part # 770-994) when using Rigid Pipe vent systems.
• Maintain clearance to combustibles.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing through a wall.
Horizontal (Feet)
12
10
8
6
4
Vertical Height (Feet)
2
0
0
2
648
Max. 36”(0.9m)
Flex 42-1/8"(1.0m)
Rigid 44-1/4"(1.1m)
24
Factory Setting - No Restrictor Required
Factory Setting - No Restrictor Required
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
RIGID PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
The minimum components required for a basic horizontal termination using 4" x 6-5/8" are:
1 Rigid Pipe Adaptor 1 Reducer 1 90o Elbow 1 Wall Thimble 1 Length of pipe to suit wall thickness 1 Horizontal Termination Cap
Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
43”
(1092 mm)
A
Pipe Length
o
90 Elbow
Pipe
Length
Reducer
(4” x 6-5/8” venting)
Rigid Pipe Adaptor
Vinyl Siding
Standoff (Optional)
Wall Thimble
B
Astrocap
(946-523/P)
ASTROCAP # 946-523/P
DIMENSIONS
11”
(279mm)
11”
(279mm)
WARNING:
Do not combine venting components from different venting systems.
Exception: However, use of the AstroCapTM and FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with DuraVent Direct Vent, Selkirk Direct-Temp, Ameri Vent Direct venting and Security Secure Vent systems. Use of these systems with the Rigid Pipe Adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.
The FPI AstroCap American Metal Products, Security Secure Vent®, AmeriVent Direct Vent. AstroCapTM is the proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
Regency Bellavista™ B36X Gas Fireplace
TM
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent,
25
INSTALLATION
HORIZONTAL 5” X 8” RIGID REAR VENT KIT
FOR CORNER INSTALLATIONS
Designed for a minimum vent confi guration when using a rear vent application with a horizontal termination in a corner installation.
Kit 946-612 Includes
1 Astrocap XL 946-623/P
1 Rigid Pipe Adaptor 770-994
1 Vinyl Siding Standoff (Optional) 946-625
1 Wall Thimble 58DVA-WT
1 6" galvanized rigid pipe 58DVA-06
1 8-1/2" galvanized pipe extension 58DVA-08A
1 45º galvanized elbow 58DVA-E45
1 90 ml MillPac 948-128
0
45 elbow
Rigid Pipe Adaptor
Pipe Length
Vinyl Siding
Standoff
(Optional)
Wall Thimble
Astrocap
XL
Placement of the unit into the corner
Back top corner of unit to wall 4"
Inside corner out along the wall 55-3/4"
Across the face of the unit, wall to wall 78-1/4"
Inside corner to front face of the unit 39-1/8"
26-1/2” (673mm)
26
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
VENTING ARRANGEMENTS
ALLOWABLE VERTICAL TERMINATIONS
(MUST USE VENT REDUCER # 946-606 & RIGID PIPE ADAPTOR #770-994)
4" X 6 - 5/8" PIPE VENTING ARRANGEMENTS
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45
o
elbows equal to one 90o elbow. Maximum of four 45o elbows allowed.
Note: The Regency Direct Flex Kits (946-515 and 946-516) cannot be used in conjunction with the vent reducer and rigid pipe adaptor. Only rigid pipe may be used when 4" x 6-5/8" is ever used.
Horizontal (Feet)
14
204 10
40
38
36
34
32
30
28
26
24
22
Restrictor 1” Open
20
6
8
Maximum: 35.5 ft. (10. m)8
12
16 18
18
Vertical Height (Feet)
16
14
12
10
8
6
4
2
0
Maximum 12’ Centerline to Centerline
Restrictor 2” Open
(1.2m)
Min. 49”
Max. 10’ (3m)(centerline to centerline)
8’ (2.4m)
Minimum
Maximum: 19 ft. (5.8m)
• Vent must be supported at offsets.
• Firestops are required at each fl oor level and whenever passing through a wall.
• Maintain clearances to combustibles as listed in the "Clearances" section.
• Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting to 2" opening to 1" opening.
Note: Must use optional fl ue adapter when using Rigid Pipe (Part # 770-994).
Regency Bellavista™ B36X Gas Fireplace
27
INSTALLATION
VENTING ARRANGEMENTS HORIZONTAL TERMINATION
(MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR)
(RIGID PIPE 4" X 6-5/8")
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o two 45o elbows equal one 90o elbow).
18
16
14
12
10
8
Vertical Height (Feet)
6
4
2
0
4
2
0
Horizontal (Feet)
8
6
12
10 14 16
18 20
ALL RIGID PIPE SYSTEMS
Restrictor 1” Open
4" INNER DIAMETER
6-5/8" OUTER DIAMETER
Restrictor 2” Open
• Maintain clearances to combustibles as listed in "Clearances" section
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing through a wall.
• A wall thimble is mandatory for all horizontal terminations due to high temperatures.
49" (1245mm) Minimum Height Requirement
HORIZONTAL VENTING WITH TWO (2) 90O ELBOWS
(RIGID PIPE 4" X 6 - 5/8")
H1
One 90o elbow = Two 45o elbows.
Option V H + H1
A) 0' Min. 2' Max. B) 1' Min. 3' Max. C) 2' Min. 4' Max. D) 3' Min. 5' Max. E) 4' Min. 6' Max. F) 5' Min. 7' Max. G) 6' Min.
Vent Restrictor Set at 2" Opening
Lengths do not include elbow indicated. Must use reducer # 946-606 and rigid pipe adaptor #770-994.
28
8' Max.
77''7'
With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.
Please note minimum 1 foot between 90o elbows is required.
H
V
Regency Bellavista™ B36X Gas Fireplace
HORIZONTAL VENTING WITH THREE (3) 90O ELBOWS
(RIGID PIPE 4" X 6 - 5/8")
H1
H
V1
INSTALLATION
V
One 90o elbow = Two 45o elbows.
Option V H V + V1 H + H1
A) 0' Min. 1' Max. 1' Min. 2' Max. B) 1' Min. 2' Max. 3' Min. 3' Max. C) 2' Min. 2' Max. 5' Min. 4' Max. D) 3' Min. 2' Max. 7' Min. 5' Max.
With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.
E) 4' Min. 3 Max. 9' Min. 6' Max. F) 5' Min. 4' Max. 10' Min. 7' Max. G) 6' Min. 5' Max. 11' Min. 8' Max.
Please note min. 1 foot between 90 elbows is required.
H) 7' Min. 6' Max. 12' Min. 9' Max.
Vent Restrictor - Full Open/ No Restrictor Installed
Lengths do not include elbow indicated. Must use reducer # 946-606 and rigid pipe adaptor #770-994.
VERTICAL VENTING WITH THREE (3) 90O ELBOWS
(RIGID PIPE 4" X 6 - 5/8")
o
V1
One 90o elbow = Two 45o elbows.
Option V H + H1 V + V1
A) 0' Min. 2' Max. 2' Min. B) 1' Min. 2' Max. 3' Min. C) 2' Min. 3' Max. 4' Min. D) 3' Min. 4' Max. 6' Min. E) 4' Min. 5' Max. 7' Min. F) 5' Min. 6' Max. 8' Min. G) 6' Min. 7' Max. 9' Min.
With these options, max. total pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizontal.
Please note min. 1 foot between 90o elbows is required.
H) 7' Min. 8' Max. 10' Min.
Vent Restrictor Set at 2" Opening
Lengths do not include elbow indicated. Must use reducer # 946-606 and rigid pipe adaptor #770-994
Regency Bellavista™ B36X Gas Fireplace
H1
H
V
29
INSTALLATION
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements on next page for minimum and maximum heights.
Required Parts:
Part # Description
946-529 Co-linear DV Vertical Termination Cap 948-305 3" Flex - 35 ft. 946-563 Co-Axial to Co-Linear Adapter Kit which contains the following: Co-linear Flex Adapter Outer Pipe Inner Pipe Adapter 770-994 Rigid Pipe Adaptor 946-606 Vent Reducer
Alternate Approved Caps
46dva-VC Vertical Termination Cap 46dva-VCH High Wind Cap 46dva-GK
NOTE: See detailed venting arrangements,
vertical terminations, co-linear fl ex system
into masonary fi replaces in this manual.
3" Co-linear Adapter with fl ashing
Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the exible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
Co-linear DV
Vertical Termination
Cap # 946-529
A maximum
of two certified
joiner kits
may be used
per length.
Flex Liner
#948-305 (35 ft)
Exhaust
Flue
Outer
Pipe with Kit# 946-563
Air Intake
Pipe Length
Co-Linear
Reducer #946-606
(4 x 6-5/8 venting)
Rigid Pipe Adapter
# 770-994
90 Degree
Elbow
Inner Pipe
Adapter with Kit# 946-563
Flex
Adapter
with Kit# 946-563
30
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
VENTING ARRANGEMENT - VERTICAL TERMINATIONS
CO-LINEAR FLEX SYSTEM
INTO MASONRY FIREPLACES
FOR BOTH RESIDENTIAL & MANUFACTURED HOMES
Use Reducer # 946-606 & #770-994 Rigid Pipe Adaptor
30
Vertical Height (feet)
8' Min.
51-1/4”
Horizontal Distance (Feet)
Restrictor 1” Open
30' Max.
Restrictor 2” Open
Use Reducer # 946-606 & #770-994 Rigid Pipe Adaptor
30
Vertical Height (feet)
2’ max.
Horizontal Distance (Feet)
8' Min.
49”
Restrictor 1” Open
30' Max.
Restrictor 2” Open
Use Reducer # 946-606 & #770-994 Rigid Pipe Adaptor
30
Vertical Height (feet)
2’ max.
Horizontal Distance (Feet)
6’ max.
49”
Combined min. of 8’.
Restrictor 1” Open
Combined max. of 30'.
Restrictor 2” Open
The shaded area in the diagrams show the allowable vertical terminations.
Regency Bellavista™ B36X Gas Fireplace
31
INSTALLATION
UNIT INSTALLATION
WITH HORIZONTAL
TERMINATION USING
5" X 8" VENTING
(Rigid Vent Systems)
Note: 5" x 8" venting is limited to vent confi gurations found on page 17 of this manual.
A top clearance of 2"(51mm) and side & bottom clearance of 1-1/2"(38mm) must be maintained; except when passing through a wall, ceiling, or at the termination where the use of a fi restop or wall thimble reduces the required clearance to 1-1/2" (38mm). We rec­ommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give structural rigidity for mounting the termination.
Install the vent system according to the manufacturer's instructions included with the components.
1) Set the unit in its desired location. Check to
determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.
2) Direct Vent pipe and fi ttings are designed with
special twist-lock connections to connect the venting system to the appliance fl ue outlet. A twist-lock appliance adaptor is required.
3) In conjunction with the Simpson Direct Vent
Pro system, install the adaptor after the unit is set in its desired location. Put a bead of high temperature silicone inside the outer section of the adapter and a bead of Mill Pack on the inner collar. Slip the adapter over the existing inner and outer fl ue collar. Fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier).
4) Level the fi replace and fasten it to the framing
using nails or screws through the top and side nailing strips.
5) Assemble the desired combination of pipe
and elbows to the appliance adaptor and twist-lock for a solid connection.
Note: For best results and optimum
performance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe
connection. Failure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional.
Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose.
6) Mark the wall for a 11" x 11" (279mm x
279mm) square hole. The center of the square hole should line up with the center­line of the horizontal pipe. Cut and frame the 11 inch (279mm) square hole in the exterior wall where the vent will be terminated. See diagram 2 for center line requirements.
Diagram 2
If the wall being penetrated is constructed of
non-combustible material, i.e. masonry block or concrete, an 8" (203mm) diameter hole is acceptable.
Note: a) The horizontal run of vent must be level,
or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fi re.
b) The location of the horizontal vent
termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See "Exterior Vent Termination Locations" section for more details.
7) Ensure that the pipe clearances to
combustible materials are maintained (Diagram 5). Install the termination cap.
Note: If installing termination on a vinyl
siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.
Diagram 5
The four wood screws provided should be re-
placed with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
8) Before connecting the horizontal run of vent
pipe to the vent termination, slide the Wall Thimble over the vent pipe. The wall thimble is required for all horizontal terminations.
9) Slide the appliance and vent assembly
towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap suffi cient distance so as to result in a minimum pipe overlap of 1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap.
10) Install wall thimble in the center of the 11"
(279mm) square and attach with wood screws (Diagram 7).
Diagram 7
32
Diagram 1
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
UNIT INSTALLATION
HORIZONTAL TERMINATION
WITH 5" X 8" FLEX VENT SYSTEM
Note: 5" x 8" venting is limited to vent
confi gurations found on page 17 of this manual.
Note: A top clearance of 2"(51mm) and side
& bottom clearance of 1-1/2"(38mm) must be maintained; except when passing through a wall, ceiling, or at the termination where the use of a restop or wall thimble reduces the required clearance to 1-1/2" (38mm). We recommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give structural rigidity for mounting the termination.
1) Locate the unit in the framing, rough in the
gas (preferably on the right side of the unit). Locate the centerline of the termination and mark wall accordingly. Cut an 11"(279mm) hole in the wall (inside dimension).
on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls.
5) Slip the assembled liner and termination
assembly through the thimble making sure the termination cap faces up (there are markings on the cap that show which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws.
6) Pull the centre 5"(127mm) liner and outer 8"(203mm) liner out enough to slip over the
ue collars of the fi replace. (You may wish to cut the liner shorter to make it more workable.) Do not bend liner more than 90o. The liners
must slip over the collars a minimum of 1-3/8".
7) Apply Mill Pac over the fi replace inner collar
and slip the 5"(127mm) liner down over it and attach with 3 supplied screws.
8) Do the same with the 8"(203mm) liner.
9) Apply a bead of silicone between the thimble
and termination and around the outer edge of the terminal at the wall in order to keep the water out.
ASTROCAPXL
DIMENSIONS (946-623/P)
Note: If installing termination on a siding
covered wall, a vinyl siding standoff or vinyl furring strips must be used to ensure that the termination is not recessed into the siding.
2) Level the replace and fasten it to the fram-
ing using nails or screws through the nailing strips.
3) Assemble the vent assembly by applying
Mill Pac to the 5"(127mm) inner collar of the termination and slipping the 5"(127mm) liner over it at least 1-3/8" (35mm). Fasten with the 3 screws (drilling pilot holes will make this easier). Apply Mill Pac or high temperature silicone to the 8"(203mm) fl ex pipe and slip it over the 8" outer collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 screws.
NOTE: Horizontal sections must be sup-
ported at intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags in the liner).
4) Separate the 2 halves of the wall thimble and
securely fasten the one with the tabs to the outside wall making sure that the tabs are
IMPORTANT: Do not locate termination hood where excessive snow or ice buildup may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.
5” dia. flue pipe with spring spacer
8" dia. air intake
Screws
Wall Thimble
2”x4”or2”x6”
AstroCap XL
Termination Cap
Screws
Vinyl Siding
Regency Bellavista™ B36X Gas Fireplace
33
INSTALLATION
UNIT INSTALLATION
WITH VERTICAL
TERMINATION
(MUST USE REDUCER
# 946-606 AND RIGID PIPE ADAPTOR
Note: All vertical terminations are vented using 4" x 6-5/8" venting and reducer #946-606 and rigid pipe adaptor #770-994.
1) Maintain the 1-1/2" clearances
(air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. Check "Venting" Sections for the maximum vertical rise of the venting system and the maximum horizontal offset limitations.
2) Set the gas appliance in
its desired location. Drop a plumb bob down from the ceiling to the position of the appliance fl ue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof.
3) A Firestop spacer must be installed in the
oor or ceiling of every level. To install the Firestop spacer in a fl at ceiling or wall, cut a 10 inch square hole. Frame the hole as shown in Diagram 2 and install the restop.
Diagram 2
4) Assemble the desired lengths of pipe and
elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed.
#770-994)
Diagram 1
NOTE: For best results and optimum performance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every in­ner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional.
5) Cut a hole in the roof centered on the small
drilled hole placed in the roof in Step 2. The hole should be of suffi cient size to meet the minimum requirements for clearance to combustibles of 1-1/2". Slip the fl ashing under the shingles (shingles should overlap half the fl ashing) as per Diagram 3.
Diagram 3: The upper half of the fl ashing is installed under the roofi ng material and not
nailed down until the chimney is installed.
This allows for small adjustments.
6) Continue to assemble pipe lengths.
Note: If an offset is necessary in the attic to
avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose.
Galvanized pipe is desirable above the roofl ine
due to its higher corrosion resistance. Continue to add pipe sections through the fl ashing until the height of the vent cap meets the minimum height requirements specifi ed in Dia. 4 o r local codes. Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.
7) Ensure vent is vertical and secure the base
of the fl ashing to the roof with roofi ng rails, slide storm collar over the pipe section and seal with a mastic.
8) Install the vertical termination cap by twist-
locking it.
Roof Pitch Minimum Vent Height
Feet Meters
at to 7/12 2 0.61
over 7/12 to 8/12 2 0.61
over 8/12 to 9/12 2 0.61
over 9/12 to 10/12 2.5 0.76
over 10/12 to 11/12 3.25 0.99
over 11/12 to 12/12 4 1.22
over 12/12 to 14/12 5 1.52
over 14/12 to 16/12 6 1.83
over 16/12 to 18/12 7 2.13
over 18/12 to 20/12 7.5 2.29
over 20/12 to 21/12 8 2.44
Note: Any closets or storage spaces, which
the vent passes through must be enclosed.
GAS LINE
INSTALLATION
The gas line is brought through the right side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve.
The gas line connection may be made of rigid pipe, copper pipe or an approved fl ex connector. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.
For USA installations follow local codes and/ or the current National Fuel Gas Code, ANSI Z223.1.
When using copper or fl ex connectors use only approved fi ttings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and fl ex connectors are usually considered to meet this requirement.
Important: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open fl ame for leak testing.
34
Diagram 4
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
PILOT ADJUSTMENT
Periodically check the pilot fl ames. Correct ame pattern has three strong blue fl ames: 1 fl owing around the thermopile, 1 around the thermocouple and 1 fl owing across the burner (it does not have to be touching the burner).
Note: If you have an incorrect fl ame pattern, contact your FPI dealer for further instructions.
Incorrect fl ame pattern will have small, probably yellow fl ames, not coming into proper contact with the rear burner or thermopile or thermocouple.
B36X -NG System Data
Conversion Kit# 556-969
For 0 to 4500 feet altitude
Burner Inlet Orifi ce Sizes: #45 Max. Input Rating 18,500 Btu/h Min. Input Rating 12,500 Btu/h
Supply Pressure min.5.0" w.c.
Manifold Pressure (High) 3.5"+/- 0.2" w.c.
Manifold Pressure (Low) 1.6" +/- 0.2" w.c.
B36X - LP System Data
For 0 to 4500 feet altitude
Burner Inlet Orifi ce Sizes: #55
Max. Input Rating 17,500 Btu/h Min. Input Rating 14,500 Btu/h
Supply Pressure min.11.0" w.c.
Manifold Pressure (High) 10"+/- 0.2" w.c.
Manifold Pressure (Low) 6.4" =/- 0.2" w.c.
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.
The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.
Note: To properly check gas pressure,
both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1) Make sure the valve is in the "OFF"
position.
2) Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a 1/8" wide fl at screwdriver.
3) Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON"
position.
5) The pressure check should be carried out
with the unit burning and the setting should be within the limits specifi ed on the safety label.
6) When fi nished reading manometer, turn
off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8"
at screwdriver. Note: Screw should be snug, but do not over tighten.
HIGH ELEVATION
This unit is approved in Canada for altitude to 4500 ft. (CAN/CGA-2.17-M91). For Natural Gas installations above 4500 ft. follow current CAN/ CGA-B149.1.
1) Gas on/off knob
2) Manual high/low adjustment
3) Pilot Adjustment
4) Thermocouple Connection - option
5) Outlet Pressure Tap
6) Inlet Pressure Tap
7) Pilot Outlet
8) Main Gas Outlet
9) Alternative TC Connection Point
Regency Bellavista™ B36X Gas Fireplace
S.I.T. VALVE DESCRIPTION
35
INSTALLATION
AERATION ADJUSTMENT
The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue fl ame or close for a more yellow fl ame.
CAUTION: Carbon will be produced if air shutter
is tightly closed.
Note: Any damage due to carboning
resulting from improperly setting
Minimum Air Shutter Opening:
the aeration controls is NOT covered under warranty.
NG 1/16"
Air shutter rod - located to the left of the valve assembly.
LP 1/4"
WIRING DIAGRAM
Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/ther­mostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
(Do not cut the ground terminal off under any circumstances.)
NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case the fan is installed at a later date.
For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Burner
Lockwasher
Star washer
Fan
ground wire
ON OFF
#8 Ground Lug
Nut
White
Black
(mobile home
approved)
Assembly
Piezo
Ignitor
Pilot
(To THTP)
(To TH)
White
Thermopile
Gas Pilot
Electrode
Thermocouple
To Thermocouple IN
ON OFF
Remote Receiver
or Thermostat
(Millivolt) (Optional)
Neutral
Brown
White
Live
(To TH)
120V AC 60 Hz
Remote Transmitter
(Optional)
Optional Fan # 576-917
Ground
Ground
ON OFF
Green
Black Red Red
Rotary Speed
Control
O
L
H
I
"S.I.T" Valve
Regency
Minimum Convection
Air Temp. Switch
O
F
F
P I
L
O
T
N
O
Fan
Gas In
36
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
For PROPANE Units and Units Equipped with DC Spark Boxes*
*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.
Star washer
Burner
Lockwasher
Fan
ground wire
ON OFF
Nut
(for mobile home)
White
Black
#8 Ground Lug
Assembly
Pilot
(To THTP)
(To TH)
T-Stat
Thermopile
Gas Pilot
Electrode
Thermocouple
Ground
To Thermocouple IN
ON OFF
Remote Receiver
or Thermostat
(Millivolt) (Optional)
Neutral
Live
120V AC 60 Hz
DC Spark
Box
Brown White
(To TH)
Remote Transmitter
(Optional)
Optional Fan # 576-917
Ground
Green
Ground
ON OFF
Rotary Speed
Black Red Red
Control
O
L
H
I
"S.I.T" Valve
Regency
Fan
Minimum Convection
Air Temp. Switch
O
F
F
P I
L
O
T
N
O
Gas In
WIRING DIAGRAM FOR GTMF REMOTE
Regency Bellavista™ B36X Gas Fireplace
37
INSTALLATION
VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION
NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL BRICK PANEL INSTALLATION.
1) Determine the venting confi guration.
2) Go to venting arrangements section (in the manual) to determine if a
vent restrictor setting is required.
Note: The vent restrictor does not apply to rear vent applications.
3) Align the vent restrictor plate to the required vent restrictor position
as per the diagrams shown.
4) Once the vent restrictor plate is in the required position, secure with
2 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over
tighten. (See diagram 2).
Diagram 2 Vent restrictor installed on top exhaust assembly
5) From inside the fi rebox, install the baffl e plate with 4 - 1/4" x 1/2 "
screws. Ensure all screws are tight, but do not over tighten.
Diagram 1
Baffl e Plate
Note: If installing brick panels, see brick panel instructions before proceeding to next step.
6) From inside the fi rebox, install the top heat defl ector with 2 -
1/4" x 1/2" screws. Ensure all screws are tight, but do not over
tighten.
Heat Defl ector
Diagram 3
Diagram 4
38
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
CONVERSION KIT# 556-969 FROM NG TO LP
for B36X using SIT 820 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one LP Conversion Kit # 556-969
Conversion Kit Contains: Qty. Part # Description
1 904-575 Burner Orifi ce #55 1 904-529 5/32" Allen Key 1 918-590 Decal "Converted to LPG" 1 908-528 Red "LP" label 1 910-037 LP Injector (Pilot Orifi ce) 1 910-073 Spark Generator 1 910-074 Spark Generator Wires 1 'AA' Battery 1 918-775 Instruction Sheet
Installation of LP Conversion Kit:
1) Shut off the gas supply.
2) Remove the louvers (and Arch screen
doors if they are installed).
3) Open the fl ush door and remove the
door.
4) Remove the logs and embers (if already
installed).
9) Unscrew the pilot orifi ce with the allen
key; then replace with the LPG pilot orifi ce, provided in the kit.
6) Remove the 2 screws securing the rear
log tray and lift out.
7) Remove the wire clip below the pilot cap.
10) Remove burner orifi ce with a 1/2"
wrench. Use another wrench to hold on to the elbow behind the orifi ce. Discard orifi ce.
8) Pull off the pilot cap to expose the pilot
orifi ce.
5) Remove the 2 screws holding the Burner
Assembly to the fi rebox base. Slide the Burner Assembly to the left to release it from the orifi ce and lift out.
Remove the 2 screws, push Burner Assembly
to the left and lift out.
Regency Bellavista™ B36X Gas Fireplace
11) Reinstall new burner orifi ce LPG
stamped #55 and tighten.
39
INSTALLATION
12) Turn control knob to the “OFF” position.
13) Remove the black protection cap by hand from the hi-low knob
(Fig.1).
Fig. 1
Cap
14) Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way
of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.
18) Verify that if the conversion is from NG to LPG, the screw must
be re-assembled with the red o-ring visible (Fig. 5).
19) Re-assemble the black protection cap (Fig. 6).
Red o-ring visible
LPG Configuration
Fig.5
Fig. 6
Fig.2
15) Check that the screw is clean and if necessary remove dirt.
16) Flip the screw (Fig. 3).
Red O-ring
17) Using the Allen wrench as shown in
Fig.4, rotate the screw clockwise until snug, do not overtighten.
Fig.3
Fig.4
20) Reverse steps 8 - 1.
21) Attach the label "This unit has been converted to LPG" near or on
top of the serial # decal.
WARNING!
Also check that the pilot and main
burner injectors are appropriate for
the gas type.
22) Replace yellow "NG" label with red "LPG" label.
40
WARNING!
Do not over tighten the screw.
Recommended to
grip the wrench by the short side.
Regency Bellavista™ B36X Gas Fireplace
DC SPARKER INSTALLATION
Installation of the DC Sparker:
23) Locate the Piezo Ignitor situated at the right side of the valve assembly.
Piezo
Ignitor
24) Remove the Piezo Ignitor wire from the back of the Piezo Ignitor.
Ignitor
Wire
INSTALLATION
27) Plug the DC spark generator wires to the DC Sparker.
28) Remove the battery cover from the DC Sparker and install 1 -
'AA' battery in the DC Sparker and then install the DC Sparker to the fl oor of the unit, left of the valve assembly, with two Phillips screws.
Piezo
Ignitor
25) Connect the ignitor wire from the Piezo to the DC sparker.
DC
Sparker
Ignitor
Wire
26) Connect the DC spark generator wires to the SIT Valve. Secure with a phillips head screw as shown below.
DC Sparker
Generator Wires
DC Sparker Battery Replacement
1) Remove the battery cover from the DC Sparker - remove the AA
battery.
2) Replace with a new 'AA' battery and reinstall battery cover.
Regency Bellavista™ B36X Gas Fireplace
41
INSTALLATION
BRICK PANEL INSTALLATION
Dangerous operating conditions may occur if the panels are broken.
1) Unwrap the Brick Panels from the protective wrapping.
2) Ensure that the logs are not in the unit.
Top Panel
Back Panel
Left Panel
3) Remove the heat defl ector (if installed) by removing the 2 screws securing the heat defl ector from the top of the fi rebox.
Handle with care. DO NOT FORCE INTO POSITION.
Right Panel
5) Remove the hex head screw on the upper left side of the fi rebox wall. Position left brick panel in place and secure with the brick panel clip and screw.
Heat defl ector
4) Install the back brick panel fi rst - use caution when clearing the burner assembly and rear log tray so the panel is not damaged.
Back Panel Installed
6) Slide top brick panel under left and back brick panel, use care not to damage panel.
7) Right brick panel is installed last, follow the same procedure as for left panel (see step 5).
Final Brick Panel Installation
8) Reinstall top heat defl ector (reverse Step 3).
42
Regency Bellavista™ B36X Gas Fireplace
OPTIONAL STAINLESS STEEL / BLACK ENAMEL
PANEL INSTALLATION
Before installation, panels must be handled and cleaned as per instructions noted below:
Stainless Steel Panels Black Enamel Panels
• Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration.
To protect the fi nish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even when removing protective coating).
•Stainless panels will discolor a little during normal operation. This is normal and should not be considered a defect.
INSTALLATION
• Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration.
• Black Enamel panels will discolor a little during normal operation. This is normal and should not be considered a defect.
All hand and fi nger marks MUST be cleaned off with a soft cloth and
*
a stainless steel cleaner. Most stainless steel cleaners leave a fi lm/ residue on the surface of the panels. Use an ammonia based cleaner (ie. glass cleaner) to remove this fi lm before applying heat to the unit.
Failure to do this will result in burn stains on panels which you will be unable to remove. Not protected by product warranty.
All hand and fi nger marks MUST be cleaned off with a soft cloth. Use
*
an ammonia based cleaner (ie. glass cleaner) to remove any fi ngerprints before applying heat to the unit.
Failure to do this will result in burn stains on panels which you will be unable to remove. Not protected by product warranty.
STAINLESS STEEL PANEL INSTALLATION
Note: Panels must be installed prior to the installation of the log set and vermiculite.
TOP
LEFT
) Remove the heat defl ector by removing the 2 screws securing the eat defl ector to the top of the fi rebox (see Diagram 2).
BACK
Diagram 1
RIGHT
3) Slide back panel in over burner - be careful not to scratch panel on back log tray, burner, or top panel when positioning.
Diagram 4
Heat defl ector
2) Loosen the 2 baffl e screws - position the top panel inside the fi rebox shown in Diagram 4. Slide slots of top panel into position under loosened screws, retighten the screws.
Slots on Top Panel
Regency Bellavista™ B36X Gas Fireplace
Diagram 2
Diagram 3
Diagram 5
43
INSTALLATION
4) Remove 1 screw (see inset A), position right side panel in fi rebox ­position panel clip in place and secure with 1 screw (see inset B). Tighten the screw.
Location of hex
head screw
4"
A
22"
B
Diagram 6
5) Repeat step 4 for left side panel.
6) Reverse step 1.
2) Install the back panel fi rst - use care when clearing the burner assembly and rear log tray, so panel is not scratched.
Diagram 3
3) Install the top panel next - slide the panel in over top of the back panel
- orient the panel so the fold in the metal faces in (see inset A).
Fold
A
Final Installation
Diagram 7
BLACK ENAMEL PANEL INSTALLATION
TOP
RIGHT
1) Remove the heat defl ector by removing the 2 screws securing the heat defl ector to the top of the fi rebox (see Diagram 2).
BACK
LEFT
Diagram 1
Diagram 4
4) Remove 1 screw (see inset A), position right side panel in fi rebox ­position panel clip in place and secure with 1 screw (see inset B). Tighten the screw.
A
B
Diagram 5
5) Repeat step 4 for left side panel.
6) Reverse step 1.
44
Heat defl ector
Diagram 2
Final Installation
Regency Bellavista™ B36X Gas Fireplace
Diagram 6
INSTALLATION
LOG SET INSTALLATION
Installation of Brick Panels must be completed before installing the log set.
Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.
Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
Log Kit #556-930 contains the following pieces:
A Rear Log
B Front Bottom Log
C Center Right Log
D Center Left Log
E Middle Left Log
F Front Left Log
902-156 Lava Rocks
902-179 Vermiculite
946-669 Platinum Embers
(supplied w/packaged manual)
E
A
2) Spread vermiculite along the base of the fi rebox.
Vermiculite
3) Place Log A on the rear log support pins with the fl at side to the back.
A
F
D
1) Carefully remove the logs from the packaging and unwrap them. The logs are fragile, handle with care - do not force into position.
Regency Bellavista™ B36X Gas Fireplace
B
C
4) Place Log B on the front right side of the burner. Push the back of
the log against the 2 brackets with the notch on the bottom right side of the log fi tting into the right side of the grate.
B
Notch
45
INSTALLATION
B
5) Place Log F on the front left side of the burner. Push the back of the
log against the 2 front brackets with the notch on the bottom of the log fi tting into the fi rst grate tab.
6) Position Log C across the cutout of Log B. The notch in the bottom right end fi tting against the 5th grate tab.
C
F
Notch in log F
F
Notch in log B
5th Grate Tab
A
F
B
C
7) Position Log D across the cutouts in Logs A and B with the notch on
the left side of the log fi tting into the 2nd grate tab.
A
B
46
D
2nd Grate Tab
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
A
D
F
8) Place the bottom left front edge of Log E against the rear bracket on
the burner tray and rest the log on the notch of Log D.
B
C
E
Lava Rocks
9) Place the lava rocks on the front of the burner tray in the places shown in the photo.
Separate platinum embers and place on the front burner on and around the lava rocks. Avoid stacking platinum embers. Platinum embers may be placed over burner ports.
10) Test fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of the burner to the other). If there is any fl ame hesitation, check that area for any blockage of the burner ports.
Platinum Embers
Notch in log D
A
E
F
Regency Bellavista™ B36X Gas Fireplace
D
B
C
47
INSTALLATION
Optional
WALL THERMOSTAT
A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length.
Note: Preferable if the thermostat is
installed on an interior wall.
Regency® offers an optional programmable thermostat but any 250-750 millivolt rated non­anticipator type thermostat that is CSA, ULC or UL approved may be used.
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size Max. Length
14 GA. 50 Ft.
16 GA. 32 Ft.
18 GA. 20 Ft.
20 GA. 12 Ft.
22 GA. 9 Ft.
Optional
REMOTE CONTROL
Regency offers 3 different remote control options which are Profl ame GT, GTM and GTMF models. See next page of all available features of each version.
Use the Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
1) Choose a convenient location on the wall
to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fi replace to that location. Use Thermostat Wire Table.
CAUTION
Do not wire millivolt
remote control wires
to 120V wire.
2) See optional remote control instruction
manual for detailed instructions.
WALL SWITCH
(INCLUDED)
1) Run the supplied 10' of wire through the
right or left side gas inlet opening. Be careful not to damage wire.
Note: We recommend a maximum of 10'
of wire but if you wish to go with a longer run, use the Thermostat Wire Table.
2) Connect the wire to the wall switch and
install into the receptacle box*. Also attach wires to the valve as shown below.
*The receptable box (gang box) is not
supplied with the unit. Must be purchased separately.
CAUTION
Do not wire millivolt
wall switch wire
to 120V wire.
48
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
Note: Regency Profl ame wall switches are white (not black as shown).
Regency Bellavista™ B36X Gas Fireplace
49
INSTALLATION
FAN INSTALLATION
Important: 120 Volt AC power is needed for the fan switch and blower. The receptacle box will be installed on the left hand side of the unit and will need to be wired by a qualifi ed electrician prior to fan assembly being installed. The neutral (wider) slot of the polarized receptacle should be at the top.
Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances.
1) Shut the power off.
2) Open the bottom louver. Remove the
standard fl ush door.
3) Turn the fan base on its side (with the base
facing towards you) and then slide the fan in towards the rear of the unit. Turn the fan upright and slip it over the two mounting studs. Take care not to damage the insulation on the fan base. Ensure that the fan blades
do not rub against the valve tubing.
5) Slide the thermodisc/cover assembly into
the bracket clip on the underside of the fi rebox. Check that no wire will touch the hot surfaces. Diagram 3 and 4.
6) Plug the fan power cord into the rear end of
the receptacle box to provide the maximum clearance from the louvers.
*Ensure that there is no interference with
the wires when the louver is closed and that no wire will touch the hot metal surfaces or sharp edges.
Diagram 3
8) Secure the fan wires and power cord by attaching one of the adhesive backed wire
holder clips (Part #910-199) onto the stove base. Use the second clip to bundle up the wires approximately 4" from the control box.
Diagram 6
Diagram 7
Diagram 1
Electrical
Receptacle
Push Fan down
on mounting pins
Ground Lug
Plug fan power cord into receptacle.rear
Diagram 2
4) Connect fan ground cable to ground lug.
Refer to wiring diagram.
Diagram 4
7) Slide the the Fan control box under the clip on the fl oor of the fi rebox. (See Diagram 5)
Diagram 5
Clip
TO REMOVE THE FAN
1) Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for life.
Do not lubricate them. Make sure you vacuum the fan area on a regular basis.
IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle.
50
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
FLUSH GLASS DOOR INSTALLATION
1) Line up slots on ush glass door with tabs in rebox. Hook slots on to tabs and lower door slowly (See Diagram 1).
Tabs in Firebox
Diagram 1
2) Lower the ush door, then hook the 2 adjustable tension latches - close the latches to secure the ush door(See Diagram 2).
Adjustable Tension
Latch location
Note: To remove Flush Glass door reverse Steps 1 and 2.
Regency Bellavista™ B36X Gas Fireplace
Diagram 2
51
INSTALLATION
OPTIONAL FINISHING TRIM INSTALLATION
NOTE: Install the Finishing Trim prior to installing the Flush Louvers.
1) Install the Finishing Trim sides as shown in the diagram; line up the holes in the
side trim with the holes in the fi rebox side.
2) Secure with 2 screws per side.
3) Loosen the 2 screws in the top inside edge of the fi rebox.
4) Slide the Finishing Trim Top over the Side Trim pieces and
fi t the bottom bracket slots over the screws. Tighten the 2 screws to secure in place.
Finishing Trim Top
Finishing
Trim Side
Finishing Trim
Edge of Unit
FLUSH LOUVERS AND FLUSH PANEL INSTALLATION
To install the top and bottom louvers or fl ush panels:
1) Locate the tabs on louvers/fl ush panels.
2) Line up the tabs on louvers/fl ush panels with the brackets on the unit.
3) Hook the tabs up over the brackets to attach.
Tabs on Louver/Flush Panel
Installation of upper
Louver/Flush Panel
52
Bracket on unit for upper
Louver/Flush Panel
Bracket on unit for lower
Louver/Flush Panel
Installation of lower
Louver/Flush Panel
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
FULL SCREEN ARCH DOOR AND FRAME INSTALLATION
1) Remove glass door (refer to glass door removal in the manual).
2) Install 4 Phillips screws (supplied with packaging) to the inside walls of the unit (see Diagram 1 for locations).
Do not tighten the screws - leave them loose for the next step.
Diagram 1
3) Lift screen doors off of door frame to reduce the weight during installation.
4) Mount the door frame onto 4 loosened screws and retighten.
Note: The door frame is adjustable up by 3/4" to accommodate for fi nished fl ooring.
The door frame can also be adjusted out 3/4" from the unit to accommodate fi nishing materials. See Diagram 2
5) Install bottom mesh door .
a) Locate tabs on bottom mesh door.
b) Locate bracket on lower fl oor of unit.
c) Hook the tab on the bottom mesh door over the bracket to install
Diagram 3a
Tabs on bottom mesh door.
Diagram 3b
Bracket on unit for bottom mesh
door.
7) Rehang screen doors on frame ­ See Diagram 5.
Diagram 5
Diagram 2
Regency Bellavista™ B36X Gas Fireplace
Final Screen Install
Diagram 4
6) Reinstall glass door.
53
OPERATING INSTRUCTIONS
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the glass door frame
is properly positioned. Never operate the appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) The unit should never be turned off, and on
again without a minimum of a 60 second wait.
FIRST FIRE
The FIRST FIRE in your heater is part of the paint curing process. To ensure the paint is properly cured, it is recommended you burn your fi replace for at least four (4) hours the fi rst time.
When fi rst operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac­turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.
NOTE: When the glass is cold and the appliance
is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.
DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!
DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE.
LIGHTING
PROCEDURE
IMPORTANT To ignite or reignite the pilot, you must fi rst remove the glass door.
NOTE: The Gas ON/OFF knob cannot be turned from "ON", "PILOT" or "OFF" unless it is partially depressed.
1) Ensure the wall mounted switch or remote
is in the "OFF" position.
2) Turn the gas control knob so the indicator
points to the "OFF" position and wait 5 min­utes for any gas in the combustion chamber to escape.
3) Turn the gas control knob counterclockwise
so the indicator points to the "PILOT" position. Depress the gas control knob fully. Depress the igniter button until the pilot lights. After approximately one minute, release the gas control knob. The pilot fl ame should continue to burn.
Only when the pilot holds, without pressure
being applied to the gas control knob, re-install the glass door to the unit. The unit must not be operated without the glass door in place.
If the pilot does not remain lit, repeat opera-
tion allowing a longer period before releasing gas control knob.
4) When the pilot stays lit, turn the gas control
knob to the "ON" position.
5) Use the wall switch or remote control to turn
the unit ON.
NOTE: When using the remote control refer to
the remote manual.
*Propane Units Equipped with DC Spark Box.
NOTE: If there is no spark present at the pilot
when depressed, the AA battery may be weak. Refer to "DC Spark Battery Replacement" section.
NORMAL OPERATING
SOUNDS OF GAS
APPLIANCES
It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.
Blower:
Regency® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON.
Burner Tray:
The burner tray is positioned directly under the burner tube(s) and logs and is made of a different gauge material from the rest of the fi rebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.
Blower Thermodisc:
When this thermally activated switch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal.
Pilot Flame: While the pilot fl ame is on it can make a very slight "whisper" sound.
Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.
Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.
During the fi rst few fi res, a white fi lm may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.
54
SHUTDOWN
PROCEDURE
1) Turn the wall mounted switch or remote to
the "OFF" position.
2) Press "OFF" on the remote control.
3) Turn the gas control knob to the "OFF" posi-
tion to turn off the pilot.
Regency Bellavista™ B36X Gas Fireplace
OPERATING INSTRUCTIONS
COPY OF LIGHTING PLATE INSTRUCTIONS
OFF
a
Regency Bellavista™ B36X Gas Fireplace
55
MAINTENANCE
MAINTENANCE INSTRUCTIONS
1) Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.
2) Clean appliance and door with a damp
cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fi replace glass cleaner.
The glass should be cleaned when it starts looking cloudy.
3) The heater is fi nished in a heat resistant
paint and should only be refi nished with heat resistant paint. Regency® uses StoveBright Paint - Metallic Black #6309.
4) Make a periodic check of burner for proper
position and condition. Visually check the ame of the burner periodically, making sure the fl ames are steady; not lifting or fl oating. If there is a problem, call a qualifi ed service person.
5) The appliance and venting system must be
inspected before use, and at least annually, by a qualifi ed fi eld service person, to ensure that the fl ow of combustion and ventilation air is not obstructed.
Note: Never operate the appliance without
the glass properly secured in place.
6) Do not use this appliance if any part has been
under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water.
7) In the event this appliance has been
serviced check that the vent-air system has been properly resealed & reinstalled in accordance with the manufacturer's instructions.
8) Verify operation after servicing.
General Vent Maintenance
2) Remove the Cap, and shine a fl ashlight
down the Vent. Remove any bird nests, or other foreign material.
3) Check for evidences of excessive
condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.
4) Inspect joints, to verify that no pipe
sections or fi ttings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.
Note: Improper positioning of logs may
create carbon build-up and will severely alter the unit's performance which is not covered under warranty.
THERMOPILE /
THERMOCOUPLE
1) Open the Bottom Louvers or Grills. Remove the Top Louver or Grill.
2) Remove the Trim Kit, Glass Door, Log Set, Grate and Burner Assembly (see the "Log Installation" & "Glass Door Removal" sections).
3) Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Disconnect thermopile by loosening 2 screws marked TP on the valve.
GLASS GASKET
If the glass gasket requires replacement use a tadpole glass gasket (Part # 936-155).
DOOR GLASS
Your Regency® fireplace is supplied with high temperature 5mm-Tempered glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot. * The use of substitute glass will void all product warranties. * Care must be taken to avoid breakage of the glass. * Do not strike or abuse the glass. * Do not operate this fi replace without the glass front or with a cracked or broken glass front. * Wear gloves when removing damaged or broken glass. * Replacement of the glass panels should be done by a licensed or qualifi ed service per son.
GLASS REPLACEMENT
In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only. Replacement glass (Part # 940-358/P) is shipped already installed into the door frame. Reinstall as per Glass Door Installation in the "Glass Door Removal" section.
Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately.
56
4) Remove 2 screws from the pilot assembly and pull up far enough to be able to loosen the thermocouple or thermopile with a 7/16" wrench. NOTE: the pilot line is very fragile, use caution when pulling it up.
5) Drop the thermocouple or thermopile down through the extrusion and pull it out of the unit.
6) Reinstall the new ones in reverse order.
Regency Bellavista™ B36X Gas Fireplace
MAINTENANCE
REMOVING VALVE
1) Shut off the gas supply.
2) Remove the louvers
3) Open the ush door and remove the door.
(See Pg. 47 for instructions)
4) Remove the logs.
5) Remove the burner/grate assembly by
removing the 2 Phillips head screws.
Diagram 1: Remove the left and right screws.
6) Slide the burner assembly to the left to release
it from the orifi ce, then lift it out.
8) Disconnect the inlet gas line. (see Diagram 4)
Diagram 4
9) Disconnect the wall switch wires from the
valve. (see Diagram 5)
Diagram 5
10) Remove the 8 Phillips head screws securing
the valve tray assembly in place (Diagram
6) and then lift the entire assembly out (Diagram 7).
Diagram 8
INSTALLING VALVE
1) Place new valve tray into position
2) Reinstall the 8 hold down screws.
3) Hook up the 2 TP and 2 TH wires to the ap-
propriate connections on the valve.
4) Reinstall the rear log tray.
5) Install Burner/grate assembly
6) Hook up the gas line and check for gas leaks
with a soap and water solution or a gas leak detector. (Do not use open fl ame for leak testing.)
7) Fire up the unit temporarily
Orifi ce
Diagram 2: Slide burner assembly to the left
and then remove.
7) Remove the 2 screws securing the rear log
tray and lift out. Diagram 3
Diagram 3
8) Check the manifold pressure.
9) Reinstall the logs and brick panels as
needed.
10) Reinstall the door and replace the louvers.
11) Fire up the unit again and check for proper
ame appearance and glow on logs.
Diagram 6
Diagram 7
Regency Bellavista™ B36X Gas Fireplace
57
PARTS LIST
MAIN ASSEMBLY
Part # Description
1) 556-524 Flue Collar Outer Assembly
2) 556-085 Flue Collar Gasket
3) 556-097 Exhaust Gasket
4) 556-513 Flue Collar Inner Assembly
5) 556-088F Top Relief Plate
6) 556-094 Relief Gasket - Door Top
7) 576-901 Brick Panel 576-902 Brick Panel 576-904 Brick Panel
8) 820-389 Thermodisc Bracket
9) 910-073 Spark Generator Battery Holder
10) 948-165 Adjustable Tension Latch
11) 904-731 Capscrew 1/4 - 20 x 3.5 NC Gr5
12) 940-358/P Tempered Glass
13) 556-012 Door Frame
14) * Outerbox Assembly
15) * Firebox Assembly
Part # Description
16) 576-917 Fan Assembly
17) 910-331/P Fan Motor (120 Volts) 432-966 Fan Switch Assy (120 Volts)
18) 910-813 Power Cord (120 Volts)
19) 910-330 Fan Speed Control
20) 904-586 Knob - Speed Control
21) 910-142 Thermodisc - Fan Auto ON/OFF
22) 946-000 Round Duct Adaptor
23) 910-367 Box - Plastic Switch Receptacle
24) 910-412 Fan Speed Controller
25) 910-417 Knob - White
26) 910-366 Switch Cover Plate - White
27) 946-006 Grill Plate - White
28) 946-005 Wall Adaptor Plate - White
29) 946-002 Round to Oval Adaptor
30) 946-001 Oval Duct Adaptor
31) 946-007 Angle Bracket
32) 946-517/P Fan Assembly - Heat Wave
33) 946-004 Junction Box
34) 918-759 Manual
* Not available as a replacement part.
58
Regency Bellavista™ B36X Gas Fireplace
FAN SWITCH ASSEMBLY
HEAT WAVE DUCT KIT
31
PARTS LIST
MAIN ASSEMBLY
33
32
27
28
23
24
25
26
HEAT WAVE DUCT KIT
12
22
30
29
31
10
1
2
3
11
4
5
6
15
14
13
Regency Bellavista™ B36X Gas Fireplace
8
9
16
18
20
FAN SWITCH ASSEMBLY
17
21
7
19
59
PARTS LIST
BURNER ASSEMBLY
Part # Description
1) 556-077 Rear Log Tray
2) 904-532 Insert
3) 556-525 B36X Burner Assembly
4) 556-057 B36X Grate Assembly
5) 904-655 Orifi ce # 45 NG 904-575 Orifi ce # 55 LP
6) 910-568 Valve NG/LP SIT High/Low 820
7) * Valve Tray - B36X
4
Part # Description
9) 556-574/P Valve Assembly - NG 556-576/P Valve Assembly - LP
10) 910-038 Pilot Assembly - NG 910-039 Pilot Assembly - LP 910-386 Thermocouple 910-341 Thermopile
2
1
3
5
7
9
6
10
60
Regency Bellavista™ B36X Gas Fireplace
NOTES
Regency Bellavista™ B36X Gas Fireplace
61
NOTES
62
Regency Bellavista™ B36X Gas Fireplace
WARRANTY
Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product. This warranty is not transferable.
The Warranty: Limited Lifetime
The combustion chamber, heat exchanger, burner tubes/pans, logs, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty for fi ve (5) years for parts and subsidized labour* and parts only thereafter.
Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for fi ve (5) years and parts only thereafter from date of purchase.
External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date of purchase and parts only thereafter.
Special Finishes - One year on brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, ie. fi nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.
Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly components, and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.
FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.
Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.
Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.
Conditions:
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
Porcelain/Enamel - Absolute perfection is either guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of installation. Reported damage after this time will be subject to rejection.
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect.
The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency unauthorized service persons or dealers.
At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.
Exclusions:
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. ie. as products evolve, fi eld modifi cations or upgrades will not be performed.
FPI will not be liable for travel costs for service work.
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.
Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation, negligence or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryer, etc.
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.
Performance problems due to operator error will not be covered by this warranty policy.
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty on this product.
Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.
* Subsidy according to job scale as predetermined by FPI.
®
product. FPI will not be liable for results or costs of workmanship from
Regency Bellavista™ B36X Gas Fireplace
63
FPI fi replaces are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door.
FPI Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a FPI Product.
See the inside back cover for details.
Register your Regency® online at
http://www.regency-fi re.com
Installer: Please complete the following information
Dealer Name & Address: ______________________________________________
___________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.: __________________________________________________________
Regency Bellavista is a trademark of FPI Fireplace Products International Ltd.
© Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved.
64
Regency Bellavista™ B36X Gas Fireplace
Printed in Canada
Loading...