Regency B36X User Manual

Regency Bellavista
B36X
Owners &
Installation Manual
Gas Fireplace
MODEL: B36X
Medium DV Gas Fireplace
www.regency-fi re.com
WARNING:
If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
918-759
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FOR YOUR SAFETY
What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch:
do not use any phone in your building.
Immediately call your gas supplier
from a neighbour's phone. Follow the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
02/05/09
To the New Owner:
Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The Bellavista™ B36X has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The Bellavista™ B36X has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency®
Fireplace.
MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regency® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88a-2007 / CSA 2.33a-2007 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes.
This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Ensure that structural members are not cut or weakened during installation.
2
Regency Bellavista™ B36X Gas Fireplace
TABLE OF CONTENTS
SAFETY LABEL
Copy of Safety Decal .....................................................4
REQUIREMENTS
MA Code - CO Detector.................................................5
DIMENSIONS
Unit Dimensions ............................................................6
INSTALLATION
Important Message ......................................................7
Before You Start ............................................................7
General Safety Information............................................7
Installation Checklist .....................................................8
Locating Your Gas Fireplace .........................................8
Heatwave Duct System (Optional) ...............................8
Clearances ....................................................................9
Mantel Leg Clearances................................................10
Mantel Clearances.......................................................10
Framing ......................................................................11
Finishing ......................................................................12
Unit Assembly Prior to Installation ...............................13
Top Standoff Assembly ........................................13
Top Facing Support ..............................................13
Side Nailing Strips ...............................................13
Top Flue Collar Installation ..................................14
Venting Introduction .....................................................15
Exterior Vent Termination Requirements .....................16
Approved Venting Confi gurations ................................17
Rigid Pipe Cross Reference Chart ..............................19
4" X 6-5/8" ...........................................................19
5" X 8" ................................................................21
Horizontal Terminations ...............................................23
Regency® Direct Vent Flex System (5" x 8") ........23
Rigid Pipe venting arrangements (5" x 8") ...........24
Rigid Pipe Venting Systems .................................25
HORIZONTAL 5” x 8” rigid rear vent kit ....................... 26
for corner installations .................................................26
Venting Arrangements ................................................27
4" x 6 - 5/8" pipe venting arrangements ...............27
Venting Arrangements Horizontal Termination ....28
Horizontal Venting with Two (2) 90o Elbows ................28
Vertical Venting with Three (3) 90o Elbows ..................29
Vertical Termination With Co-linear Flex System .........30
Venting Arrangement - Vertical Terminations ..............31
Unit Installation with Horizontal Termination ................ 33
Unit installation with Vertical Termination ....................34
Gas Line Installation .................................................... 34
Pilot Adjustment ........................................................... 35
High Elevation .............................................................35
Gas Pipe Pressure Testing ..........................................35
S.I.T. Valve Description ................................................35
Aeration Adjustment ....................................................36
Wiring Diagram ............................................................36
Wiring diagram for GTMF remote ................................37
Vent Restrictor, Baffl e & Heat Defl ector Installation ....38
Conversion from NG to LP ..........................................39
DC Sparker Installation................................................41
Brick panel installation .................................................42
Optional Stainless Steel / Black Enamel .....................43
Panel Installation .........................................................43
Log Set installation ......................................................45
Optional Wall Thermostat ...........................................48
Optional Remote Control ............................................. 48
Wall Switch (Included) .................................................48
Fan Installation ............................................................ 50
Flush glass door Installation ........................................ 51
Optional Finishing Trim Installation..............................52
Flush Louvers and Flush Panel Installation .................52
Full Screen Arch Door and Frame Installation .............53
OPERATING INSTRUCTIONS
Operating Instructions .................................................54
First Fire ......................................................................54
Lighting Procedure ......................................................54
Shutdown Procedure ................................................... 54
Normal Operating Sounds Of Gas Appliances ............ 54
Copy of Lighting Plate Instructions .............................. 55
Maintenance Instructions.............................................56
Log Replacement ........................................................56
Thermopile / Thermocouple .........................................56
Door Glass...................................................................56
Removing Valve ...........................................................57
Installing Valve .............................................................57
PARTS LIST
Main Assembly ............................................................58
Burner Assembly .........................................................60
WARRANTY
The Warranty: Limited Lifetime ...................................64
Regency Bellavista™ B36X Gas Fireplace
3
SAFETY LABEL
This is a copy of the label that accompanies each Bellavista™ B36X Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
NOTE: Regency improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
®
units are constantly being
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli­ances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.
COPY OF SAFETY DECAL
4
Regency Bellavista™ B36X Gas Fireplace
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
Regency Bellavista™ B36X Gas Fireplace
5
DIMENSIONS
33” (838mm)
UNIT DIMENSIONS
21”(533mm)
30-3/8” (762mm)
35-1/4”
(895mm)
39-1/16”
(992mm)
37-1/2” (953mm)
17-5/16” (440mm)
20-1/4” (514mm)
1”(25.4mm)
36” (914mm)
33-1/16” (840mm)
35-1/4” (895mm)
26-1/2” (673mm)
19-5/16” (490mm)
6
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The Bellavista™ B36X Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturers instructions and all applicable codes.
BEFORE YOU START
Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE­CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform
with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.
2) The appliance when installed, must be
electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.
3) See general construction and assembly
instructions. The appliance and vent should be enclosed.
4) This appliance must be connected to the
specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.
5) Inspect the venting system annually for
blockage and any signs of deterioration.
6) Venting terminals shall not be recessed into
a wall or siding.
7) Any safety glass removed for servicing
must be replaced prior to operating the appliance.
8) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the replace.
9) Wear gloves and safety glasses for protection
while doing required maintenance.
10) Be aware of electrical wiring locations in
walls and ceilings when cutting holes for termination.
11) Under no circumstances should this appliance
be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.
12) Installation and any repairs to this appliance
should be done by a qualifi ed service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.
15) The appliance area must be kept clear and
free of combustible materials, (gases and other fl ammable vapours and liquids).
Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
Regency Bellavista™ B36X Gas Fireplace
7
INSTALLATION
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location (Refer to "Locating Your
Gas fi replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantel Clearances (Refer to "Combustible
Mantel Clearances" section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2) Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips (Refer to "Unit Assembly Prior to Installation" Section). NOTE: Must be done before installing unit into place.
3) Install vent (Refer to "Venting" sections).
4) Make gas and electrical connections. Test
the pilot. Must be as per diagram (Refer to "Pilot Adjustment " section).
Convert to propane if desired (Refer to "Gas
Line Installation" and "Conversion Kit from NG to LPG" sections).
5) Install standard and optional features. Refer
to the following sections:
a. LP Conversion Kit (Optional) b. Brick Panels (Optional) c. Log Set Installation d. Standard Flush Door e. Full Screen Door (Optional) f. Flush Panel/Louver (Optional) g. Remote control,Wall Switch or
Thermostat (Optional)
h. Fan Installation (Optional)
6) Final check.
This includes:
1) Clocking the appliance to ensure the correct
ring rate (rate noted on label) after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your replace,
ensure that the clearances are met.
2) The appliance must be installed on a fl at,
solid, continuous surface For example a wood, metal or concrete fl oor or in a raised (on the wall) application. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.
3) The B36X Bellavista™ Gas Fireplace can
be installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.
Diagram 1
4) This appliance is Listed for bedroom
installations using the standard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.
5) The B36X Gas Fireplace are approved for
alcove installations, see "Clearances" section for details.
6) We recommend that you plan your installation
on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.
Note: For vent terminations refer to
"Exterior Vent Termination Locations" section.
HEATWAVE
DUCT SYSTEM
(OPTIONAL)
#946-556
The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home.
Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time. This includes the internal blower option as well.
A) Flat on Wall B) Flat on Wall Corner C) Recessed into Wall/Alcove D) Corner
8
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions.
The top, back and sides of the fi replace are defi ned by
standoffs. The metal ends of the standoff may NOT be
Caution Requirements
recessed into combustible construction.
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fi replace and vent
system be installed only in accordance with these instructions.
B36X Clearance Requirements
Clearance: Dimension Measured From:
A: Mantel Height (min.) 6-1/2" (165mm) Top of Fireplace Opening
B: Sidewall 12" (304mm) on one side Side of Fireplace Opening
C: Ceiling 36-34" (933mm) Top of Fireplace Opening
D: Mantel Depth 12" (304mm) 14-1/2 " (368mm) from
E: Alcove Width 84" (2134mm) Sidewall to Sidewall (Minimum)
F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum)
Notes: 0" No Hearth Required
Top of Fireplace Opening
Fire hazard is an extreme risk
WARNING
Minimum Vent Clearances
to Combustibles
Horizontal Top 2" (51mm)
Horizontal Side 1-1/2 " (38mm)
Horizontal Bottom 1-1/2" (38mm)
Vertical Vent 1-1/2" (38mm)
Regency Bellavista™ B36X Gas Fireplace
9
INSTALLATION
MANTEL CLEARANCES
Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing
are shown in the diagram on the right.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-
combustible board.
Mantel Clearances
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the paint may discolour.
12
14
12
12”
6
810
4
7”
2
0
Combustible
Mantel Clearances B36X
From Top of Fireplace Opening
6
B
0
Inches
To Floor
ABCD
32"
(813mm)
14-1/2"
(368mm)
11"
(279mm)
6-1/2"
(165mm)
MANTEL LEG CLEARANCES
12” Side Wall
(Measured from side of
Fireplace Opening)
A
C
To p o f
Fireplace
Opening
1"
D
Top Header
Standoff
Side View
10
Top View
Mantel leg
1-1/2"
2"
5"
Allowable mantel leg
projection.
Mantel leg
3"
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
FRAMING
Framing Dimensions Description B36X
M Framing Width 36 - 1/4"(921mm)
N Framing Height 39 - 3/8" (1000mm)
O (Rear Vent) Framing Depth - Rear Vent 20 - 3/4" (527mm)
O (Top Vent) Framing Depth - Top Vent 19 - 1/2" (495mm)
P (Top Vent) Corner Facing Wall Depth 48 - 5/8" (1235mm)
P (Rear Vent) Corner Facing Wall Depth 53" (1346mm) AstroCapXL
Q (Top Vent) Corner Facing Wall Width 68 - 3/4" (1746mm)
Q (Rear Vent) Corner Facing Wall Width 75" (1905mm) AstroCapXL
R (Rear Vent) Framed Chase Ceiling - Rear 39 - 3/8" (1000mm)
R (Top Vent) Framed Chase Ceiling - Top 50-1/2" (1282mm)
S (Rear Vent) Vent Centerline Height - Rear 26-1/2" (673mm)
S (Top Vent) Vent Centerline Height - Top 44-1/4" (1123mm) Rigid
T Gas Connection Height 1-1/2" (38mm)
U Gas Connection Inset 4-1/8" (105mm)
V Gas Connection Width 3-1/4" (82mm)
W Non-Combustible Top Height 0"
61-1/2" (1562mm) - other approved caps
87" (2209mm) - other approved caps
42-1/8" (1070mm) Flex
N
M
R
Drywall
(or other
facing)
Top Header
Combustible Facing
11" (279mm)
dia. Hole through
wall Vent.
O
S
S
P
T
U
Q
Note: If installing the unit into a corner and rear venting - use AstroCapXL 946-623/P to obtain closest clearance.
Regency Bellavista™ B36X Gas Fireplace
Opening for gas
V
connection
11
INSTALLATION
FINISHING
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into fi nal position - it is important to know the total thickness / height of fi nished hearth (tile, carpet, etc.) The base of the replace should be level or higher than the fi nished hearth height.
Diagram 1
Note: All facing material should butt up cleanly to the fl anges
around the fi rebox opening.
Rough edges will be visible from the front view with the fl ush
louvers or fl ush panels - if not using the fi nishing trim.
To maintain a clean fi nished edge - it is recommended to install
the drywall or other facing material with the fi nished edge against the fi replace / nailing strips.
Alternatively, you can use J Style Trim or Metal Corner Bead to cover cut edges of the facing material.
Important:
Finishing materials such as tile, river rock, etc, must not protrude
beyond the front facing fl anges the sides and top of the fi rebox opening.
Full Screen Doors Only:
If fi nishing with any material thicker than 1-1/4" - a 3/4" gap must
be maintained between the full screen doors and the fi nishing material.
This gap is necessary to facilitate the installation and removal of
the full screen doors.
Diagram 3
3/4"
Finishing material - thicker
than 1-1/4"
Full Screen
Door
12
Diagram 2
Diagram 4
1"
There is a 1" air space between the unit and full screen door
Note:
which must not be covered.
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
UNIT ASSEMBLY PRIOR TO INSTALLATION
BEFORE YOU START
The Top Facing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the fi replace is moved into position.
TOP STANDOFF ASSEMBLY
The top standoffs are shipped in a fl at position and must be folded into shape and attached.
1) Remove the standoffs from the fi replace top.
2) Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the pre-punched screw holes on the fi replace top line up.
3) Attach the standoff securely to the top with 2 screws per standoff (on opposite corners).
Determine the total thickness of facing material (e.g. drywall or wood plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.
Screw Facing Material
The Top Facing Support can be mounted in 3 different positions depending on the thickness of the facing material.
Position Depth
A 1/2" / 13mm B 7/8" / 22mm C* 1-1/4" / 32mm
* For "C" screw position the top facing support is reversed.
1) Mount Top Facing Support using the 3 supplied screws into the three pre-punched screw holes on the top front of the unit. Use hole positions A, B, or C depending on your facing depth.
Top Facing
TOP FACING SUPPORT
Support
Top Facing Support
Screw holes for
Top Facing
Support
C
B
A
SIDE NAILING STRIPS
The side nailing strips come attached to the unit. There are 2 plates, one on the top and bottom that can be folded out as required.
Plates can be
folded out.
Top Facing Support
is reversed
for “C” hole position
C
B
A
Regency Bellavista™ B36X Gas Fireplace
"C" Screw Position:
For a facing material depth of 1-1/4" (32mm), the top facing support must be reversed.
13
INSTALLATION
UNIT ASSEMBLY PRIOR TO INSTALLATION
TOP FLUE COLLAR INSTALLATION
The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented.
1 Intake Collar Assembly with Gasket
1 Intake Collar Plate with Gasket
1 Top/Rear Exhaust Assembly with Gasket
1 Heat Defl ector
1 Baffl e Plate
29 1/4" x 1/2" Screws (4 spares)
1 Restrictor
1 Intake Collar Gasket (spare)
1 Exhaust Assembly Gasket (spare)
1. Remove the door assembly by releasing the adjustable latches and lifting up off the door frame assembly.
Note: This conversion must be done prior to the unit being placed in position.
Top Collar Assembly Kit
Exhaust Assembly
w/ gasket
Intake Collar Plate
w/gasket
Intake Collar Assembly
w/gasket
Adjustable Tension
Latch location
2) From inside the rebox, remove the top heat defl ector by removing
2 - 1/4" x 1/2" screws.
Heat Defl ector
3) From inside the rebox, remove the baffl e plate by removing 4 - 1/4"
x 1/2 " screws. See Diagram 3
Baffl e Plate
14
Diagram 2
Diagram 3
Diagram 1
4) From the inside of the rebox, remove the exhaust assembly by
removing the 8 - 1/4" x 1/2" screws. See Diagram 4.
Diagram 4
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
5) From the outside rear of the fi rebox, remove the intake collar
assembly. Remove the 4 - 1/4" x 1/2" screws. See Diagram 5.
Exhaust
Assembly
Intake Collar
Assembly
Diagram 5
6) From the outside top of the rebox, remove the intake collar plate
by removing the 4 - 1/4" x 1/2 " screws. See Diagram 6.
8) From the outside top of the rebox, install the intake collar assembly.
Secure with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten. All 4 screws must be used.
Exhaust
Assembly
Diagram 9
9) From the outside rear of the rebox, install the intake collar plate
with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten. All 4 screws must be used.
Intake Collar
Assembly
Diagram 6
Before proceeding to Step 7, inspect condition of all gaskets. DO NOT install parts with damaged gaskets. Replace if necessary
with spare gaskets supplied.
7) From the inside of the rebox, place the exhaust assembly into position as shown in Diagram 7 and secure with 8 - 1/4" x 1/2" screws (Diagram 8). Ensure all screws are tight, but do not over tighten.
All 8 screws must be used.
Diagram 7
Diagram 10
10) From inside the rebox, re-install the baffl e plate and heat defl ector - reverse steps 2 & 3.
VENTING
INTRODUCTION
The B36X uses the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
Note: These fl ue pipes must not be connected to any other
appliance.
The gas appliance and vent system must be vented directly to the
outside of the building, and never be attached to a chimney serving
a separate solid fuel or gas burning appliance. Each direct vent gas
appliance must use it's own separate vent system. Common vent
systems are prohibited.
Diagram 8
Regency Bellavista™ B36X Gas Fireplace
15
INSTALLATION
EXTERIOR VENT TERMINATION REQUIREMENTS
1
Minimum Clearance Requirements
A Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm)
B Clearance to window or door that may be opened 12"(30cm) 9" (23cm)
C Clearance to permanently closed window **
D Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm) 24"(60cm) 24"(60cm)
E Clearance to unventilated soffi t 12"(30cm) 12"(30cm)
F Clearance to outside corner: with AstroCap Termination Cap. 13"(33cm) 13"(33cm)
Clearance to outside corner: with all other approved Termination Caps. 13"(33cm) 13"(33cm)
G Clearance to inside corner: with AstroCap Termination Cap 6"(15cm) 6"(15cm)
Clearance to inside corner: with all other approved Termination Caps. 6"(15cm) 6"(15cm)
H Clearance to each side of center line extended above meter/regulator assembly 36"(90cm)
J Clearance to service regulator vent outlet 36"(90cm) *
K Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 12"(30cm) 9" (23cm)
L Clearance to a mechanical air supply inlet 72"(1.8m) 36"(90cm)
M Clearance above paved sidewalk or a paved driveway located on public property 84"(2.1m)
N Clearance under veranda, porch, deck, or balcony 12"(30cm)
1
In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor
Clearance in accordance with local installation codes and the requirements of the gas supplier
*
a
3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b
3 feet (91cm) above - if within 10 feet (3m) horizontally
Canada
a
USA
*
*
*
2
b
16
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
APPROVED VENTING CONFIGURATIONS
HORIZONTAL & VERTICAL TERMINATIONS
Regency Bellavista™ B36X Gas Fireplace
17
INSTALLATION
APPROVED VENTING CONFIGURATIONS
HORIZONTAL & VERTICAL TERMINATIONS
Vertical Venting Configurations
Vertical Rear Vent Flex Vent 4" x 6-5/8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Rear Vent Flex Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Rear Vent Rigid Vent 4" x 6-5/8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Rear Vent Rigid Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Top Vent Flex Vent 4" x 6-5/8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Top Vent Flex Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved
Vertical Top Vent Rigid Vent 4" x 6-5/8" • Min. 8 ft vertical run
• Max. 35.5 ft vertical run
• Up to 2 x 90o elbows
• See manual for details
Various applications See manual for details
Rigid Pipe Adaptor
Vent Reducer
770-994
946-606
Vertical Top Vent Rigid Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved
18
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
RIGID PIPE CROSS REFERENCE CHART
4" X 6-5/8"
(MUST USE VENT REDUCER # 946-606 AND RIGID PIPE ADAPTOR #770-994)
Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI.
Regency Bellavista™ B36X Gas Fireplace
19
INSTALLATION
20
Regency Bellavista™ B36X Gas Fireplace
Loading...