HOW TO USE YOUR ACTIVE 320S SHOWER (SUMMARY)
IMPORTANT WARNINGS!
DO NOT SWITCH THE APPLIANCE ON IF YOU SUSPECT IT OF BEING FROZEN.
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.
DO NOT OPERATE THE APPLIANCE IF WATER DISCHARGES FROM THE PRESSURE RELIEF
VALVE. MAINTENANCE IS REQUIRED BEFORE THE APPLIANCE CAN BE SAFELY USED.
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN
AND THE INFIRM) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES,
OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION
OR INSTRUCTION CONCERNING USE OF THE APPLIANCE
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY
DO NOT PLAY WITH THE APPLIANCE.
1. Ensure the electricity and water are turned on to the unit.
2. Turn outer knob “A” clockwise to the “Power Select”
position of your choice.
= High Power
= Medium Power
= Cold Shower
The water will flow, and the neon indicator light will glow.
It is recommended that you do not enter the spray during
this period, especially if the shower has just been used.
3. Turn inner knob “B” a small amount until you reach
the desired showering temperature.
Turn anti-clockwise (follow blue arrows) for cooler.
Turn clockwise (follow red arrows) for warmer.
4. When you have finished showering, turn outer knob “A” anti-clockwise to the “ ” position.
(You have no need to adjust inner knob “B”).
5. Water will continue to flow for up to 3 seconds before switching off.
This reduces the temperature of the water in the tank for the next user.
The neon indicator light will go out.
6. Switch off the electricity supply at the ceiling switch or local isolator.
Notes
• Wait 20 seconds for the temperature to stabilise after each adjustment.
• The neon indicates when the heaters are on and, if the shower has been recently used,
it may take up to 20 seconds to come on.
During this time the water may go from very hot to cold before stabilising.
Also, please note that the neon indicator does not light when the shower is set to the
“ “ cold power setting.
• The position of inner knob “B” will be approximately the same each time the shower is
used, varying only with incoming water temperature or pressure changes
(e.g. you will only need to change from summer to winter).
• During normal operation, if an overheated water temperature is sensed then the heater
will switch off and the neon indicato
Water will continue to flow and cool down before the heater switches back on again.
We offer a technical advisory service on the telephone: RING 0844 372 7766 (UK ONLY)
(A4) Leaflet No. 555-2136-01e
IMPORTANT:
This booklet should be left with the user after
installation and demonstration
REDRING ACTIVE 320S
SMART TECHNOLOGY
ELECTRIC SHOWER
Installation and User Guide
2
INTRODUCTION
If you experience any difficulty with the installation or operation of your new
shower, then please refer to the “What to do if things go wrong” section in this
manual before contacting us.
Thank you for purchasing a quality Redring Active 320S Electric Shower manufactured in England.
To enjoy your new shower at its best, please take time to read this manual thoroughly to
familiarise yourself with all instructions, BEFORE beginning installation.
The Redring Active 320S is an electric shower incorporating our “Smart Technology” and a unique
dual control combining on/off, power select and flow/temperature control.
Your shower is designed to stabilise temperature
changes caused by water pressure fluctuations.
These can result from toilets being flushed or taps being turned on and off.
When this happens your showering temperature will be held within a controlled band, provided that
the minimum pressure required by the shower is maintained (see “Effect of Other Water Devices”).
1. Your shower has been designed for convenience, economy and safety of use, provided that it is
installed, used and maintained in good working order and in accordance with our instructions and
recommendations.
2. All wiring and installation must be supervised by a suitably qualified person.
3. THIS APPLIANCE MUST BE EARTHED.
4. The installation must be in accordance with the current edition of BS.7671 (the “IEE Wiring
Regulations”) and “Part P” of the “Building Regulations” in force at the time of installation.
Installations outside England and Wales must also conform to any local regulations in effect.
This appliance is intended to be permanently connected to the fixed electrical wiring of the mains
supply with its own dedicated supply.
5. This appliance must NOT be fitted where it may be subjected to freezing conditions
6. DO NOT switch the appliance on if you suspect it of being frozen.
Wait until you are sure it has thawed out.
7. DO NOT fit any sort of tap or control on the appliance outlet. The appliance is designed to have
an open outlet and should only be used with “Redring” recommended fittings.
8. The shower handset provided is designed to work with electric showers.
Only use the manufacturers approved accessories with this shower.
9. Take care to avoid restricting the outlet of the pressure relief device. If water is discharged from
the pressure relief device, maintenance will be required before the appliance can be safely used.
10. Isolate the mains electrical and water supply before removing the front cover of the appliance.
Section
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to install your Active 320S Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to maintain your Active 320S Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to use your Active 320S Shower (Detailed) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (1) Self Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Additional Accessories and Common Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (2) Professional Service . . . . . . . . . . . . . . . . . . . . . . .
Redring After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How your Active 320S Shower Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guarantee and Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to use your Active 320S Shower (Summary) . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page
2
2
3
6
7
8
8
9
9
10
11
12
CONTENTS
IMPORTANT SAFETY INFORMATION
:
Full details of terms and conditions are available on request from:-
APPLIED ENERGY PRODUCTS LIMITED
MORLEY WAY, PETERBOROUGH PE2 9JJ
TEL: +44 (0) 844 372 7761
FAX: +44 (0) 844 372 7762
Website: www.redring.co.uk
GUARANTEE AND CONTACT DETAILS