Redring POWERSTREAM-ECO, 9.5kW Powerstream-Eco, 10.8kW Powerstream-Eco Installation And User Manual

IMPORTANT:
installation and demonstration.
It should be kept in a safe place, as you may need to
refer to it for general instructions or future
maintenance
REDRING POWERSTREAM-ECO
UNVENTED INSTANTANEOUS
WATER HEATER
Installation and User Guide
Powerstream-Eco
2
CONTENTS
If you experience any difficulty with the installation or operation of your new
water heater, then please refer to the “What to do if things go wrong” section
in this manual before contacting us.
INTRODUCTION
REDRING AFTER SALES SERVICE
Thank you for purchasing a quality
Redring Powerstream-Eco
manufactured in England.
To enjoy your new unit at its best, please take time to read this manual thoroughly to familiarise yourself with all instructions, BEFORE beginning installation.
We offer a technical advisory service on the telephone to installers and other customers with problems in the field.
RING 0844 372 7766 (UK ONLY)
RING YOUR LOCAL DEALER (Export Variants)
Or alternatively email us on:
Service.request@redringxpelair.com
Remember to quote the exact type of unit, as written on the front of the unit and on this leaflet. The model and serial number are located on the bottom face of the unit. Make a note of those numbers here, and be sure to quote them if you call for advice.
Model Number: _ _ _ _ _ _ _ _ _ _ _ Serial Number: _ _ _ _ _ _ _ _ _ _ _ _
Note: You may be charged for a service call if you do not have the serial number.
Section
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Redring After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to install your
Powerstream-Eco .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commissioning your
Powerstream-Eco .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to use your
Powerstream-Eco .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (1) Self Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (2) Professional Service . . . . . . . . . . . . . . . . . . . . . . .
How your
Powerstream-Eco
Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Additional Accessories and Common Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guarantee and Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page
2
2
3
4
9
10
12
13
14
15
15
16
3
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8
YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL,
SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE
AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION
OR INSTRUCTION CONCERNING USE OF THE APPLIANCE
IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED.
CHILDREN SHALL NOT PLAY WITH THE APPLIANCE.
CLEANING AND USER MAINTENANCE SHALL NOT
BE MADE BY CHILDREN.
Your
Powerstream-Eco
has been designed for convenience, economy and safety of use, provided that it is installed, used and maintained in good working order and in accordance with our instructions and recommendations.
All wiring and installation must be supervised by a suitably
qualified person.
THIS APPLIANCE MUST BE EARTHED. The installation must be in accordance with the current edition of
BS.7671 (
the “IEE Wiring Regulations”)
and “Part P” of the
“Building
Regulations
in force at the time of installation. Installations outside
England and Wales must also conform to any local regulations in effect.
This appliance is intended to be permanently connected to the fixed
electrical wiring of the mains supply with its own dedicated supply.
Ensure that the mains water supply meets the requirements listed.
This appliance must NOT be fitted where it may be subjected to freezing
conditions. DO NOT switch the appliance on if you suspect it of being frozen. Wait until you are sure it has thawed out.
The unit MUST NOT be mounted upside down (diagram 1b).
The unit MUST NOT be fitted to any type of THERMOSTATIC
mixer valve or tap.
If a non-return valve is fitted in the Inlet feed to the unit, then the
installation should also include a 3.5 BAR Pressure Reducing Valve and a 6 BAR Pressure Relief (Expansion) Valve.
Isolate the mains electrical and water supply before removing
the front cover of the appliance.
IMPORTANT SAFETY INFORMATION
4
WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY QUALIFIED PERSON.
WARNING: DO NOT INSTALL THIS UNIT WHERE IT MAY BE SUBJECTED TO FREEZING CONDITIONS.
The Powerstream-Eco is recommended to supply a
MAXIMUM of two washbasins (see diagram 1a) OR a washbasin and shower (see diagram 4b)
If the Powerstream-Eco is connected to a mixer tap then only NON-Thermostatic types should be used (water mixes at the outlet pipe only).
The Powerstream-Eco is NOT to be fitted to a bath or kitchen sink other than for hand-washing purposes. (See Guarantee exclusions on page 16 and product flow rate tables on page 14).
The unit MUST NOT be mounted upside down (diagram 1b).
BEFORE YOU START
Check that the mains electric is capable of supplying the required current. See the rating plate for current requirements.
Check the pressure of the main water supply. To operate correctly, the unit requires the following running pressures. Check the rating plate to see which applies:-
Model
Dynamic Water Pressure
Basin
Shower
Minimum
Maximum
Minimum
Maximum
Up to 9.5kW
10 psi (0.7 bar)
(69 kPa)
150 psi (10.3 bar)
(1035 kPa)
15 psi (1.1 bar)
(103 kPa)
150 psi (10.3 bar)
(1035 kPa)
Up to 10.8kW
15 psi (1.1 bar)
(103 kPa)
150 psi (10.3 bar)
(1035 kPa)
20 psi (1.4 bar)
(138 kPa)
150 psi (10.3 bar)
(1035 kPa)
HOW TO INSTALL YOUR
POWERSTREAM-ECO
Diagram 1a
Examples of fitted units
Diagram 1b
Acceptable unit orientation
5
FIXING THE UNIT TO THE WALL
Deciding the position
If being used in a public place, position the unit out of reach to discourage vandalism. Fit the unit onto a flat piece of wall, well away from any potential splashes of water or spray. Position the unit either upright or lengthways (diagram 1a/b), whichever is most convenient for
plumbing and wiring.
IMPORTANT : TO MAINTAIN THE INTEGRITY OF THE IPX4 PROTECTION RATING, THE UNIT MUST NOT BE MOUNTED UPSIDE DOWN (DIAGRAM 1B)
Remember to keep the lengths of hot water pipe to a minimum in order to save energy.
If the unit is to supply a basin, you can fit it either above or below the basin.
Deciding the wiring route
You have a choice of whether to feed the electric cable
through the side or through the back of the unit.
If it going through the side of the unit, cut out the
plastic lug to expose the grommet (diagram 2).
If is going through the back of the unit, cut through the
grommet on the backplate with a sharp knife (Take Care!). Make sure you do not remove the grommet from the backplate (diagram 3). Feed the cable through the grommet before you fix the unit to the wall.
Fixing to the wall
Undo the retaining nuts and take the front cover off the unit.
Hold the backplate in position against the wall whilst you mark the four fixing holes.
Drill the holes and fix the unit to the wall using the screws supplied.
Diagram 2
Lug cut out
Diagram 3
Back of unit