Red Lion SL Series, SLX Series Quick Start Guide

Part #: INSERT-SL-SLX
All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in accordance with the authority having jurisdiction. “This Equipment is Suitable for Use in Class I, Division 2, Groups A, B, C, D or Non-Hazardous Locations Only”.
WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.
WARNING – EXPLOSION HAZARD – WHEN IN HAZARDOUS LOCATIONS, DISCONNECT POWER BEFORE REPLACING OR
WIRING UNITS.
WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
WARNING EXPLOSION HAZARD IN HAZARDOUS OR POTENTIALLY HAZARDOUS LOCATIONS, DO NOT SEPARATE ANY PART OF THE UNIT WHEN ENERGIZED. USE THE UNIT FOR INTERNAL CONNECTIONS ONLY.
Tout pouvoir, le câblage d’entrée et de sortie (I/O) doivent être conformes aux méthodes de câblage de Classe I, Division 2 et conformément à l’autorité compétente.
Cet équipement est adapté pour une utilisation en Classe1, Division 2, Groupes A, B, C et D ou endroits non-
dangereux seulement .
AVERTISSEMENT – RISQUE D’EXPLOSION – LA SUBSTITUTION DE TOUT COMPOSANT PEUT NUIRE À LA CONFORMITÉ DE CLASSE I, DIVISION 2.
AVERTISSEMENT – RISQUE D’EXPLOSION – LORSQUE DANS DES ENDROITS DANGEREUX, DÉBRANCHEZ LE CORDON D'ALIMENTATION AVANT DE REMPLACER OU DE BRANCHER LES MODULES.
AVERTISSEMENT – RISQUE D’AVERTISSEMENT – NE DÉBRANCHEZ PAS L’ÉQUIPEMENT PENDANT QUE LE CIRCUIT EST DIRECT OU À MOINS QUE L’ENVIRONNEMENT SOIT CONNU POUR ÊTRE LIBRE DE CONCENTRATIONS INFLAMMABLES.
AVERTISSEMENT – RISQUE D’EXPLOSION – DANS LES ENDROITS DANGEREUX OU POTENTIELLEMENT DANGEREUX, NE
PAS SEPARER UNE PARTIE DE L'UNITE SOUS TENSION. SEULEMENT UTILISEZ L'APPAREIL POUR LES CONNEXIONS INTERNES.
SLX Models
in
Metal Case
SL/SLX Series
Installation & Operating Instructions
(Quick Start Guide)
SL Models
in
Plastic Case
1. Carefully remove the switch and any accessories from the shipping container and inspect them for damage.
Contact Red Lion immediately if any damage is discovered.
2. Install the switch to your DIN rail as shown in the diagram below. First, hook the top of the DIN rail clip to
the rail. Then push the bottom of the switch towards the rail until it locks into place. Refer to the full installation guide for removal instructions.
3. Apply power to the switch per the instructions following the warnings below.
Part #: INSERT-SL-SLX
The switch will have a removable screw terminal plug (green) as shown in the diagram. The
Ring Port 2
Ring Port 1
function of each position will be indicated on a label adjacent to the plug and/or on the
side of the switch. The absolute minimum and maximum voltages are also indicated.
To meet the UL requirements you must do one of the following:
A. Install a 3.33 Amp maximum fuse at the input of the switch B. Use a Class 2 source to power the switch
Note: The maximum screw torque is 5 in/lb (0.57 Nm). Do not over tighten.
Connect power to the switch as follows:
A. Turn off your source power. B. Make sure the area is currently nonhazardous (Class I, Div 2 or Zone 2 locations).
C. Connect a ground wire between the chassis ground screw and your panel. For SL models that don’t
have a chassis ground screw then use the screw position marked as . The SL-6RS has neither and is automatically connected to ground when installed on the DIN rail.
D. Connect your positive input wire to the P1 position. If you have dual power sources then apply your
secondary positive input wire to the P2 position.
E. Connect your minus or return wire(s) to the “-“ position. F. See the full installation guide for optionally connecting the alarm output on some models. G. Turn on your source power and verify that the power LED(s) are on.
4. Plug in your Ethernet cables and the switch will immediately start to operate and pass data.
5. Now you may configure the switch for more advanced operations. See below for further information.
Unmanaged Switches (ES or EG): No configuration is available or necessary.
Managed Switches (MS or MG):
To set the IP address so that you can manage the switch via the web interface:
A. Connect the switch directly to your PC’s Ethernet port using any Ethernet patch cable. The switch’s
default IP is 10.2.0.1 or 192.168.0.1 (switch shipped after April, 2010).
B. On your PC, go to Control Panel – Network Connections and access the properties for your LAN’s
Internet Protocol (TCP/IP). Record your current settings, then select “Use this IP address” and set the
IP and subnet to 10.2.0.100 or 192.168.0.100 (see note above). Close and reboot if prompted.
C. Run a web browser and type 10.2.0.1 or 192.168.0.1 into the address bar and hit enter. Use “admin”
for both user name and password to access the web interface.
D. In the Quick Setup screen, enter your desired IP and subnet, or enable DHCP. Click on “Commit
Changes” to save these new settings to the switch.
E. Repeat step 4 to return your PC to its original IP address and subnet mask.
Now you can access your switch using the new IP address. Refer to the full management guide or web interface help for details on further configuring the switch.
Ring Switches (RS):
The last two ports of a ring switch are pre-configured as the ring ports. Use these ports to form your ring as shown in the diagram below.