Portions of this document are intended solely as an outline of methodologies to be followed during the
maintenance and operation of the RAM 9000 equipment/software. It is not intended as a step-by-step guide or a
complete set of all procedures necessary and sufficient to complete all operations.
While every effort has been made to ensure that this document is complete and accurate at the time of release, the
information that it contains is subject to change. Red Lion Controls is not responsible for any additions to or
alterations of the original document. Industrial networks vary widely in their configurations, topologies, and traffic
conditions. This document is intended as a general guide only. It has not been tested for all possible applications,
and it may not be complete or accurate for some situations.
Users of this document are urged to heed warnings and cautions summarized at the front of the document, such as
electrical hazard warnings.
Compliance Information
Part 15 of the Federal Communications Commission (FCC) - A Rules: Interference
Every effort has been made to ensure that this equipment is designed to comply with the limits for a Class A digital
device, as described in the FCC Rules. This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. Operation of this device in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his/her own expense.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment
Regulations. Operation is subject to the following two conditions; (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Environmental Impact Statement
Red Lion equipment contains no hazardous materials as defined by the United States Environmental Protection
Agency (USEPA). Red Lion recommends that all failed product be returned to Red Lion for failure analysis and
proper disposal.
Toxic Emissions
Red Lion equipment releases no toxic emissions.
Sixnet® Series RAM® 9000 Hardware Guideiii
Revised 2016-02-12Preface
Trademark Acknowledgments
•Windows® /98/2000/7/8, Windows XP® are registered trademarks of the Microsoft Corporation.
•Microsoft is either a registered trademark or trademark of Microsoft Corporation in the United States and/or
other countries.
TM
•Ethernet
is a registered trademark of Xerox Corporation.
•EtherNet/IPTM and CIPTM are registered trademarks of ODVATM.
•All other company and product names are trademarks of their respective owners.
Release Notes and Document Updates
The hard copy and flash drive versions of this document are revised only at major releases and, therefore, may not
always contain the latest product information. As needed, Application Notes and or Product Bulletins will be
provided between major releases to describe any new information or document changes.
Publication History
The following information lists the release history of this document.
ISSUE/REVISIONRELEASE DATECONTENT DESCRIPTION
R06February 2016JP and 3.23/4.23 release.
R05September 2015
R04March 2015Updates to Warnings
R03September 2014Modifications to FCC Statement to cellular frequency bands
R02August 2014
R01April 2014First release
EU release. Added uniform Warranty Statement and document
template
Wi-Fi capability added. Change to operating temperature and
thermal performance
Related Documents
The following information lists available documents related to this product.
ISSUE/REVISIONRELEASE DATEDOCUMENT TITLE
Version 7February 2016SN/RAM 6000 & RAM 9000 Software Manual
Version 6March 2015RAM 9000 Quick Start Guide
Version 6February 2015RAM 6000 Quick Start Guide
ivSixnet® Series RAM® 9000 Hardware Guide
PrefaceRevised 2016-02-12
Document Ordering Information
To order additional documentation, the user can contact the local sales representative or Red Lion through the
contact numbers and/or e-mail addresses listed on the back of the cover.
Document Comments
Red Lion appreciates all comments that will help us to improve our documentation quality. The user can submit
comments through the Red Lion Customer Service. Simply email us at customer.service@redlion.net.
Additional Product Information
Additional product information can be obtained by contacting the local sales representative or Red Lion through the
contact numbers and/or e-mail addresses listed on the back of the cover.
Safety Information
Must consult guide in all cases where this symbol is marked.
Warnings/Cautions/Notes
Warnings apply to situations where personal injury or death may result.
Cautions apply where damage to equipment may result
Notes apply where additional noteworthy information, not in the general text flow but applicable, is made available
to the user.
Hazardous Location and Installation Requirements
These products should not be used to replace proper safety interlocking. No software-based device (or any other
solid-state device) should ever be designed to be responsible for the maintenance of consequential equipment or
personnel safety. In particular, Red Lion disclaims any responsibility for damages, either direct or consequential,
that result from the use of this equipment in any application.
All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in
accordance with the authority having jurisdiction.
Suitable for use in Class I, Division 2, Groups A, B, C and D hazardous locations, or non-hazardous locations only.
These products are operator interface units to be used within control panels in hazardous locations. The enclosure
shall be suitable for the location.
AVERTISSEMENTS POUR INSTALLATION ET ENDROITS DANGEREUX
Ces produits ne doivent pas être utilisés pour remplacer le verrouillage de sécurité approprié. Aucun dispositif
basé sur un logiciel (ou tout autre dispositif à l'état solide) devraient jamais être conçus pour être responsable de
l'entretien de l'équipement consécutifs ou la sécurité du personnel. En particulier, Red Lion décline toute
Sixnet® Series RAM® 9000 Hardware Guidev
Revised 2016-02-12Preface
responsabilité pour les dommages, directs ou indirects, résultant de l'utilisation de cet équipement dans n'importe
quelle application.
Tout courant, câblage entrée et sortie (I / O) doit être conforme aux méthodes de câblage à la Classe I, Division 2
et conformément à l'autorité compétente.
Cet appareil est adapté pour utilisation en Classe I, Division 2, Groupes A, B, C, D endroits dangereux ou endroits
non-dangereux.
Ces produits sont des unités d'interface opérateur qui doivent être utilisés à l'intérieur des panneaux de commande
dans les endroits dangereux. L'enclos doit être adapté à l’environnement.
WARNING: Explosion Hazard – Substitution of components may impair suitability for Class I,
Division 2.
AVERTISSEMENT - Risque d'explosion -
La substitution de tout composant peut nuire à la
conformité de Classe 1, Division 2.
WARNING – Explosion Hazard – When in hazardous locations, disconnect power before
replacing or wiring modules.
AVERTISSEMENT – Risque d’explosion - Lorsque dans des endroits dangereux, débran-
chez le cordon d’alimentation avant de remplacer ou de brancher les modules.
WARNING – Explosion Hazard – Do not disconnect equipment unless power has been
switched off or the area is known to be non-hazardous.
AVERTISSEMENT - Risque d'explosion -
Ne débranchez pas l’équipement à moins que
l’alimentation ait été coupée ou que l’environnement est connu pour être non dangereux.
WARNING - Explosion Hazard - Exposure to some chemicals may degrade the sealing
properties of materials used in the relays.
AVERTISSEMENT - Risque d'explosion - L’exposition à certain produits chimiques peut
dégrader les propriétés d’étanchéité des matériaux utilisés dans les relais.
WARNING - Explosion Hazard - Batteries must only be changed in an area known to be
non-hazardous.
AVERTISSEMENT - Risque d'explosion - Batteries doivent être changées dans une zone
connue pour être non dangereuse.
viSixnet® Series RAM® 9000 Hardware Guide
PrefaceRevised 2016-02-12
Environmental
The unit may become very hot to the touch in high temperature environments, so extreme caution should be
exercised in handling when energized. The unit should be disconnected from power and allowed to cool for
approximately 5 minutes before touching in high temperature applications.
WARNING: Disconnect the power and allow to cool 5 minutes before touching.
AVERTISSEMENT: Déconnectez le câble d'alimentation et laisser refroidir 5 minutes avant de la
toucher.
Pollution degree: 2 (Per IEC 61010-1)
Electrical
WARNING: Device must be supplied by a Class 2 power source.
AVERTISSEMENT: l'appareil doit être alimenté par une source d'alimentation de classe 2.
WARNING: Properly ground the unit before connecting anything else to the unit. Units not
properly grounded may result in a safety risk and could be hazardous and may void the warranty.
See the grounding technique section of this manual for proper ways to ground the unit.
AVERTISSEMENT: L'unité doit être correctement mise à la terre avant tout raccordement à
l'unité. Unités pas correctement mise à la terre peuvent causer un risque de sécurité et pourraient être dangereuses et peuvent annuler la garantie. Voir la section technique de mise à la
terre dans ce mode d'emploi pour des moyens appropriés à la masse de l'appareil.
Over-voltage category: II (Per IEC 61010-1)
Sixnet® Series RAM® 9000 Hardware Guidevii
Product OverviewRevised 2016-02-12
RAM® 9000 Cellular RTU Product Highlights
Chapter 1Product Overview
Using a single web-based user interface, our cellular units simplify I/O, network and security configurations to integrate complex hardware settings. This easy-to-manage configuration reduces the cost and complexity of deploying
and administering multiple devices at remote locations. Furthermore, an integrated configurable stateful firewall
provides intrusion protection and encrypted data access while a built-in Software Development Kit (SDK) enables
users to develop custom applications.
Working in conjunction with SixView Manager remote monitoring and control software, RAM RTUs provide lowcost, real-time access to outlying sites.
RAM® 9000 Cellular RTU Product Highlights
• Supports Multi-Carrier 4G LTE connectivity with fall back to 3G (and 2G for non-EU/JP Models)
• Real-time access to mission-critical data through built-in Modbus gateway
• Software Development Kit (SDK) for custom application support
• The equipment shall be installed in an ATEX-Certified enclosure that provides a
degree of
used in an environment of not more than Pollution Degree 2 in accordance with EN/
IEC60664-1 when applied in Zone 2 environments. The enclosure must be
accessible only by the use of a tool.
protection not less than IP54 in accordance with EN/IEC 60079-15 and
• Conditions of Safe Use: Provision shall be made to prevent the rated voltage being
exceeded by the transient disturbances of more than 140% of the peak rated
voltage
• Special Conditions of Use: Antenna Connections are for internal wiring only.
•
CompliancesThe Red Lion Sixnet Series RAM 9000 products meet the following standards plus others:
Electrical Safety
These devices have been designed to meet the basic safety requirements of the following
standards:
• CE per Low Voltage Directive and IEC 61010-1 (CE applies only to the -EU
models. Please contact Red Lion for availability)
• UL508 (Industrial control equipment), ANSI/ISA 12.12.01 (Hazardous Locations)
• CSA C22.2 No. 142 and No. 213 (per cUL)
1-4Sixnet
®
Series RAM® 9000 Hardware Guide
Product OverviewRevised 2016-02-12
Specifications
EMC (emissions and immunity)
• CE per the EMC directive (CE applies only to the -EU models. Please contact Red
Lion for availability)
• IEC 61000-6-2: Immunity in industrial environments
• IEC 61000-6-4: Emmissions in industrial environments
• FCC part 15 and ICES 003. See FCC statement on page 6.
• EN 55022 (CISPR22)
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reason
able protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy;
and if not installed and used in accordance with the instructions, may cause harmful interfer
ence to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference to radio communications, in which case the user will be required
to correct the interference at their own expense. Warning: Changes or modifications to this
unit not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Information to the user: If this equipment causes interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures: In order to meet
FCC emissions limits, this equipment must be used only with cables that comply with IEEE
802.3. If necessary, the user should consult the dealer or an experienced radio/television
technician for additional suggestions. The user may find the following booklet prepared by
the Federal Communications Commission helpful: “How to Identify and Resolve Radio-TV
Interference Problems”. This booklet is available from: U.S. Government Printing Office,
Washington, DC 20402, Stock No. 004-000-00345-4
-
-
WEEE compliance
These devices comply with the WEEE directive. Do not throw away these devices in the
standard trash. Contact Red Lion regarding proper disposal.
RoHS compliance
These devices comply with the RoHS directive and are considered lead and other hazardous substance free.
*-40°C to +75°C - See Thermal Performance and Considerations section in Chapter 2.
Note: All specifications are subject to change. Consult the Red Lion website for more information.
Sixnet® Series RAM® 9000 Hardware Guide1-5
Loading...
+ 29 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.