red lion GL300T User Manual

1
O
256 X 128 PIXEL VACUUM FLORESCENT DISPLAY(VFD)
O
MULTIPLE LANGUAGE SUPPORT (UP TO 8 LANGUAGES)
O
500 ALARM POINT LOGGER
O
COMPREHENSIVE REPORT GENERATION
O
POWERFUL RECIPE HANDLING
O
UNLIMITED PASSWORD PROTECTION
O
O
EXPRESSION EVALUATION
O
32-BIT/FLOATING POINT MATH
O
DIRECT NETWORK (Including Multiple Protocol) OR MODEM LINK TO PLC
O
INDUSTRIAL TOUCHSCREEN
O
NEMA 4/IP65 ALUMINUM ENCLOSURE
DESCRIPTION
Model GL300T Operator Terminal combines unique capabilities normally expected only from expensive SCADA packages, with dramatic ease of use. The GL300T is configured using the same powerful EDICT 97 Software as all Red Lion Paradigm Operator Interfaces. The results are savings in time to get challenging applications up and running, and frequent savings in hardware costs due to replacing many functions usually performed in separate expensive devices.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Do not use this unit to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the unit.
GENERAL SPECIFICATIONS
1. POWER REQUIREMENTS: 11 to 30 VDC @ 7.1 W Power Up Current: 2.5 A for 1 msec max. Must use a Class 2 or SELV rated power supply.
2. DISPLAY: 256 x 128 pixel full graphic display with cold cathode backlight. Text formats up to 16 x 40 characters.
3. MEMORY: 768K (704K user) battery backed RAM (Battery life expectancy 3 years 50/50 on/off cycle).
4. TOUCHSCREEN: Continuous resistive touch screen interface specified for up to 5 million operations. 200 X 200 touch cells
5. ENVIRONMENTAL CONDITIONS: Operating Temperature: 0 to 50°C Storage Temperature: -20 to 60°C Operating and Storage Humidity: 20 to 80% max. RH (non-condensing) from
0°C to 50°C.
Altitude: Up to 2000 meters
6. MOUNTING REQUIREMENTS: Max. panel thickness is 0.375" (9.5 mm). For NEMA 4/IP65 sealing, a steel panel with a minimum thickness of 0.125" (3.175 mm) is recommended
MODEL GL300T - MONOCHROME TOUCHSCREEN OPERATOR INTERFACE
ORDERING INFORMATION
DIMENSIONS In inches (mm)
PANEL CUT-OUT
Bulletin No. GL300T-D
Drawing No. LP0501
Released 9/08
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
256 X 128 VFD, w/touchscreen, 768 K memory
BNL20000
P895xxxZCommunication Cables
EDICT-97 Development Kit. Includes Software, Manual and 9-pin RS232 Programming cables
SFEDT
GL300TVF
Battery Replacement
GL300T
PART NUMBERDESCRIPTIONMODEL NO.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
2
PROGRAMMABILITY
Event Driven Configuration Tool
Edict 97, an extremely powerful Windows®95/3.11 based software program, provides for the intuitive configuration of every aspect of the operator interface’s behavior. The requirement for time consuming PLC ladder logic is drastically reduced by the unique event driven approach of EDICT 97. The capability of this program, in conjunction with the PLC and the Paradigm operator interface unit, ensures a great deal of advanced functionality for your system. This powerful PLC/Paradigm system provides many of the capabilities and features normally associated with the more complicated and costly PC/SCADA systems. Display pages are easily generated, including PLC and internal variables, text strings, or bar charts. All dynamic elements are also available as alarms, recipes, triggers, and reports for the run time software. After completion of the programming, the program is directly downloaded to the operator interface from your PC, without any compiling or saving requirement. When you require a change in your program, EDICT 97 loads only the change, not the entire program, saving valuable on-line time.
DYNAMIC DISPLAY PAGE ELEMENTS
Each display page has provisions to show static and dynamic information, including data variables, text messages, time, and date.
Data Variables can be either PLC derived or internally generated, either in data
entry or display only mode. The Paradigm unit has an extremely powerful
math capability, allowing the operator to manipulate the variables to meet the
specific application’s demands. If required, the display can be formatted to
BCD, binary, hex, floating point, and string. Upper and lower limits of data
entry variables are fully supported and password protected.
Text Message Animation enables several different types of animated text from
a local or global message table to be displayed. The message displayed is
dependent on the condition of the particular controlling expression. The
controlling expression may be a PLC bit level, a timer value, preset counter
condition, or any one of a wide variety of message triggers.
Time and Date in the Paradigm unit has the capability to display in any
combination of year, month, day, hours, minutes, and seconds.
Bar Graphs in horizontal format are easily attached to data variables. The partial
or full length bar graph displays can be scaled and offset to optimize the
required display effect.
SECURITY
The password protection scheme provides the ultimate in tamper-proof capability. Access can be limited on a unit, page, recipe, or even individual data entries.
ALARMS
The Paradigm unit can monitor and log up to 500 alarms. Such triggers as a simple bit level transition, a PLC coil activation, or a complex application algorithm can activate an alarm. The alarms can be time and date stamped, with an automatic screen display and/or downloading to a printer for hard copy recording purposes.
RECIPE HANDLING
Recipe handling in the Paradigm Operator Interfaces can be tailored to your requirements. Using the “Data Files” section of Named Data, one can set up arrays with meaningful titles, and select, edit, and maintain, recipe data up to 8000 elements per file. In conjunction with User Programs, and the flexible data displays, the operator can select desired recipe, by number or by title, and either upload from, or download to, the target system. All the functions of EDICT 97 are available, so the programmer can password protect the editing of the recipes and allow for the transfer of data from a host system.
REAL TIME SCHEDULE
Real time schedule allows for repetitive or one time tasks to take place in the system. Typically a schedule action similar to...At 1:55 PM on Monday, Wednesday, and Friday print the production report...is required in the application. In conjunction with the recipe capabilities, a downloading of a special recipe can be requested by the real time schedule feature.
MULTIPLE LANGUAGE SUPPORT
This powerful feature allows users to program the text in their databases in up to 8 different languages. A system variable entry makes it easy for end users to select one of the preprogrammed languages. EDICT 97 features powerful language editing tools for easy implementation.
USER PROGRAMS
This feature offers the user the ability to incorporate custom application requirements via a powerful program language. For example, a program designated “Calculate Volume,” which determines the amount of fluid in a round tank at specific temperatures, could be created. This program would be triggered to run and display each time the page denoted as “Volume Now” is requested. The ability to customize to your application’s specialized needs is easily solved with the user program capability.
COMMON FEATURES FOR TOUCHSCREEN OPERATOR TERMINALS
GENERAL SPECIFICATIONS Cont’d
7. CERTIFICATIONS AND COMPLIANCES:
ELECTRICAL SAFETY
EN 61010-1, IEC 61010-1
Safety requirements for electrical equipment for measurement, control, and Laboratory use, Part 1
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.
Notes:
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self­recovers.
3. DC power lines require 1 ferrite core (RLC#: FCOR0000) with 1 loop to meet Class A limits.
8. PHYSICAL DIMENSIONS: L = 7.64" (194.0 mm), H = 5.68" (144.3 mm), D = 2.64" (67.0 mm).
9. CONSTRUCTION: Steel rear metal enclosure with NEMA 4/IP65 aluminum front plate when correctly fitted with the gasket provided. This unit is rated for NEMA 4/IP65 indoor use. Installation Category II, Pollution Degree 2
10. FIELD CONNECTIONS: Removable screw terminal blocks.
11. WEIGHT: 2.69 lb. (1.22 Kg.)
INPUT/OUTPUT COMMUNICATIONS SPECS
1. SERIAL PORTS: Data Format and Baud Rates for each port are individually software programmable up to 19200 baud. Port 1: Programming Port - RS-232 on an RJ-11 jack. Port 2: RS-232 Port on a Plug-In Screw Terminal Block Port 3: RS-485 Port on a Plug-In Screw Terminal Block
(Up to 29 units can be connected and individually addressed.)
Note: LED Indicators show communications status on Ports 2 & 3
2. COMMUNICATION MODES: Any of the three ports can be used to communicate with Serial Devices. Model - GL300T may communicate in Master mode with a different device
protocol on each port (See Note & Exception). However, only one of the Ports 2 and 3 may be configured, if either is
selected as a Slave Protocol.
Note: Ports 2 and 3 may be configured as different device protocols in
Master mode and Port 1 may be used simultaneously in Slave mode for a third device protocol.
Exception: If Allen Bradley DH485 is selected on either Port 2 or 3, only
Port 1 will be available for a separate device protocol.
Class A
3
EN 55011Emissions
Emissions:
3 V/rms
Criterion AEN 61000-4-6RF conducted interference
2 kV L&N-E power
2 kV power
Criterion BEN 61000-4-4Fast transients (burst)
Criterion BEN 61000-4-5Surge 1 kV L-L,
10 V/m
Criterion AEN 61000-4-3Electromagnetic RF fields
1 kV signal
8 kV air discharge
4 kV contact discharge
Criterion AEN 61000-4-2Electrostatic discharge
Immunity to Industrial Locations: