ECONOLINE - DC/DC-Converter
RAA Series, 5 Watt, Unregulated (Single & Dual Output)
Selection Guide
Part |
Input |
Output |
Output |
Input Current |
Efficiency |
|
Number |
Voltage |
Voltage |
Current |
Full |
No |
|
|
|
|
|
Load |
Load |
|
30 x 30 mm |
(VDC) |
(VDC) |
(mA) |
(mA) |
|
(%) |
RAA-0505S |
5 |
5 |
1000 |
1250 |
80 |
80 |
RAA-0512S |
5 |
12 |
417 |
1150 |
80 |
87 |
RAA-0515S |
5 |
15 |
333 |
1150 |
80 |
87 |
RAA-0505D |
5 |
±5 |
±500 |
1250 |
80 |
80 |
RAA-0512D |
5 |
±12 |
±208 |
1150 |
80 |
87 |
RAA-0515D |
5 |
±15 |
±167 |
1150 |
80 |
87 |
RAA-1205S |
12 |
5 |
1000 |
496 |
40 |
84 |
RAA-1212S |
12 |
12 |
417 |
479 |
40 |
87 |
RAA-1215S |
12 |
15 |
333 |
479 |
40 |
87 |
RAA-1205D |
12 |
±5 |
±500 |
496 |
40 |
84 |
RAA-1212D |
12 |
±12 |
±208 |
479 |
40 |
87 |
RAA-1215D |
12 |
±15 |
±167 |
479 |
40 |
87 |
RAA-2405S |
24 |
5 |
1000 |
261 |
20 |
83 |
RAA-2412S |
24 |
12 |
417 |
245 |
20 |
85 |
RAA-2415S |
24 |
15 |
333 |
239 |
20 |
87 |
RAA-2405D |
24 |
±5 |
±500 |
261 |
20 |
83 |
RAA-2412D |
24 |
±12 |
±208 |
245 |
20 |
85 |
RAA-2415D |
24 |
±15 |
±167 |
239 |
20 |
87 |
Features
●1kVDC Isolation
●Efficiency to 87%
●Internal Filtering
●Dual In-Line Package
●No External Components Required
●100% Burned In
●Low Noise
●UL94V-0 Package Material
Specifications (core operating area) and Operating Temperature / Derating-Graph
Voltage Setpoint Accuracy |
±3% max. |
|
|
Temperature Coefficient |
±0.03%/°C |
|
|
Ripple and Noise (20MHz BW) |
100mVp-p max. |
|
|
Line Regulation (for 1% change in input voltage) |
±1.2% max. |
(%) |
|
Short Circuit Protection |
Short Term |
||
Efficiency |
|||
Load Regulation (for output load current change from 20% to 100%) |
±3% max. |
|
|
Input Voltage Range |
±10% min. |
|
|
Input Filter |
Pi Network |
|
|
Efficiency |
80% - 87% |
|
|
Isolation Voltage (tested for 60 seconds) |
1.000VDC min. |
|
|
Isolation Resistance |
109Ω min. |
|
|
Switching Frequency |
60kHz min. |
(%) |
|
Power |
|||
Isolation Capacitance |
80pf max. |
||
Operating Temperature |
-25°C to +70°C (see Graph) |
Output |
|
|
|||
Storage Temperature |
-55°C to +100°C |
|
|
Cooling |
Free-Air Convection |
|
|
Case Material |
Non-Conductive Plastic |
|
100
80
60
40
20
0
0 |
20 |
40 |
60 |
80 |
100 |
% of Rated |
Load |
|
|
|
120
100
70
60 |
Safe Operating Area |
|
|
||
20 |
|
|
|
|
|
0 |
|
|
|
|
|
-25 |
0 |
25 |
50 |
70 |
100 |
Operating Temperature (˚C)
www.recom-international.com |
August 2002 |
EC 77 |