EUROLINE - DC/DC-Converter
RxxT and RxxU Series, 1 Watt, DIP14/SIP7, Isolated (Twin Independent Output)
Features
● Output / Output Isolation 1kVDC |
● Internal SMD Construction |
● Input / Output Isolation 1kVDC |
● Toroidal Magnetics |
● Efficiency to 808% |
● MTTF up to 1.9 Million Hours |
● UL 94V-O Package Material |
● Power Sharing on Outputs |
|
|
Selection Guide 5V and 12V input types
Part |
Output |
Output |
Output |
Output |
Package |
Number |
Voltage 1 |
Voltage 2 |
Current 1 |
Current 2 |
Style |
|
(VDC) |
(VDC) |
(mA) |
(mA) |
|
RxxT0503 |
5 |
3.3 |
100 |
152 |
|
RxxT0505 |
5 |
5 |
100 |
100 |
|
RxxT0509 |
5 |
9 |
100 |
56 |
DIP14 |
RxxT0512 |
5 |
12 |
100 |
42 |
|
RxxT0515 |
5 |
15 |
100 |
34 |
|
RxxU0503 |
5 |
3.3 |
100 |
152 |
|
RxxU0505 |
5 |
5 |
100 |
100 |
|
RxxU0509 |
5 |
9 |
100 |
56 |
SIP7 |
RxxU0512 |
5 |
12 |
100 |
42 |
|
RxxU0515 |
5 |
15 |
100 |
34 |
|
Absolute Maximum Ratings Over Operating Free Air Temperature Range
Input Voltage VIN |
5V types |
7V |
|
12V types |
15V |
Output Power Total |
|
1W |
Short Circuit Duration 1) |
|
1s |
Input to Output Isolation Voltage (flash tested for 1 second) |
|
1000VDC |
Output to Output Isolation Voltage (flash tested for 1 second) |
|
1000VDC |
Operating Free Air Temperature Range (requires a minimum of 10 mm air space around the component) |
0°C to +70°C (see derating Curve) |
|
Storage Temperature Range |
|
–55°C to 150°C |
Lead Temperature (1.5 mm from case for 10 seconds) |
|
300 °C |
1). Supply voltage must be discontinued at the end of the short circuit duration.
EU 24 |
www.recom-international.com |