EUROLINE - DC/DC-Converter
RxxA and RxxB Series, 1 Watt, DIP14/SIP7, 1kVDC Isolation (Dual Output)
Features
● Wide Temperature Performance at |
● Efficiency to 78% |
full 1 Watt Load, –40°C to +85°C |
● UL 94V-O Package Material |
● Industry Standard Pinout |
● Internal SMD Construction |
● 1kVDC Isolation |
● MTTF up to 2.1 Million Hours |
|
|
Selection Guide 5V and 12V, input types
Part Number |
Nom. Input |
Rated Output |
Rated Output |
Input Current |
Efficiency |
Isolation |
Package |
Voltage |
Voltage |
Voltage |
Current |
at Rated Load |
|
Capacitance |
Style |
|
(VDC) |
(VDC) |
(mA) |
(mA) |
(%) |
(pF) |
|
R05A05 |
5 |
±5 |
±100 |
289 |
69 |
28 |
|
R05A09 |
5 |
±9 |
±55 |
270 |
75 |
32 |
DIP14 |
R05A12 |
5 |
±12 |
±42 |
266 |
77 |
34 |
|
R05A15 |
5 |
±15 |
±33 |
263 |
78 |
36 |
|
R05B05 |
5 |
±5 |
±100 |
289 |
69 |
28 |
|
R05B09 |
5 |
±9 |
±55 |
270 |
75 |
32 |
SIP7 |
R05B12 |
5 |
±12 |
±42 |
266 |
77 |
34 |
|
R05B15 |
5 |
±15 |
±33 |
263 |
78 |
36 |
|
R12A05 |
12 |
±5 |
±100 |
120 |
69 |
33 |
|
R12A09 |
12 |
±9 |
±55 |
113 |
74 |
46 |
DIP14 |
R12A12 |
12 |
±12 |
±42 |
111 |
75 |
55 |
|
R12A15 |
12 |
±15 |
±33 |
110 |
76 |
54 |
|
R12B05 |
12 |
±5 |
±100 |
120 |
69 |
33 |
|
R12B09 |
12 |
±9 |
±55 |
113 |
74 |
46 |
SIP7 |
R12B12 |
12 |
±12 |
±42 |
111 |
75 |
55 |
|
R12B15 |
12 |
±15 |
±33 |
110 |
76 |
54 |
|
Absolute Maximum Ratings
Input Voltage VIN 5V types |
7V |
Input Voltage VIN 12V types |
15V |
Short Circuit Duration 1) |
1s |
Internal Power Dissipation |
450mW |
Lead Temperature (1.5 mm from case for 10 seconds) |
300 °C |
1). Supply voltage must be discontinued at the end of the short circuit duration. |
|
www.recom-international.com |
EU 11 |