We recommend thatyou havethe electricalhookupof
your counterunitdoneby a qualifiedelectrician.Have
the electrician show you where your disconnect is
located.
Cali your Electric Company and
askwhich codesapply
in
your area. If there are no codes, you must follow the
NATIONAL ELECTRICAL CODE, AIWWNFPA NO, 70-
1987.You can get a copy by writing:
National Fire Protection Association
13atterymarchPark
Quincy,MA02269
If you fail to wire your counter unit in accordancewith
governingcodes,youmaycreateah&zarciouscondition.
Youmustuseathree-wire,single-phase
AC 120/240Volt
or 208Y/120
Volt, 60 Hertz electrical system.
Useaminimumwiresizeof No.10copperwire protected
with a 30 Amp. fuse or circuit breaker for both 208Y/120
Volt and 120/240Volt electrical systems.
Donot use
aluminumwiringtoconnectyourcounterunit
to thehouseholdcircuit.
Beforeinstallingthe counterunit or movingittoanother
location,havetheelectricianverify:
~ That your home is providedwith adequateelectrical
service.
s Thattheaddition of thecounter unit will notoverload
thehouseholdcircuit onwhich it isused.
Cuttheopeningin the countertop. Besureto maintain
cutout dimensionsand minimum clearancesas shown
on previouspage.
To minimizechipping of the counter-
topyoucanapply maskingtapebeforeyou makethecut.
Install an approvedjunction box where it will be easily
reachedthroughthefront of thecabinetwherethecounter unit will be located. The counter unit has 3 feet of
conduit.
EMoreinstalling the unit in the cutout, attachfoam”tape
(shipped with unit) around the bottom surface of the
glass,neartheedgeof themaintop.
Installthe counter unit in thecutout opening.Note:!fthe
unit is being installed in a blind counter (one with no
cabinetopening below),wire connections mustbe made
beforeputting the unit into the
cutout.
To
attachthe unit to the counter,insertthesideretainers
in the slot on each side of the unit. Usethe screwsand
washerssupplied to attach unit to counter as shown in
figure 3.
‘m? WHm’ica?power to the range slq)pty M@s’nu$iltbe
shut
offwhile line cmtwtkm are13dngrnwh.Fdhwe to
do so could result InsedcmsInfamyor death.
Whenmakingthewireconnections,usetheentirelength
ofconduitprovided(3ft).Thecondkdimu$tnotbecut.
Connectthe redandMackleadsfrom the counteruni
conduitto thecorrespondingleadsinthejunctionbox.
The bare groundwireintheconduitisconnected to the
counter unit frame. Connect the other end of this wire to
a properly grounded cold water pipe or use another
approved grounding method.
A white
(neutral)wire is not neededfor this unit. The
white lead from the household electrical supply can be
taped and terminated in the junction box.
BE SLJRETHIS CUT DOESNOT
INTERFEREWITH CABINET
STRUCTUREAT FRONT
IN,
d.K3GExYnED
Moui’fnr’$mm
,~
!%$$3
(J
;$~,
,4NAPPROVED J(.JNcnw3NBox
-.,
..%;”.-.4-
:.-4-<
4
!~j~$y-jg