Raypak P-514, P-724, P-1287, P-1336, P-1223 User Manual

Clubs. Universities. Municipalities. Watersport Centers. Large residential pools.
23 model sizes — 511,500 to 4,000,000 BTUH inputs.
Indoor and outdoor styles.
80-82% thermal efficiency.
Natural or propane gas.
Commercial
Pool Heaters
Rugged, efficient heaters for large pools
Precision water temperature control to ± 1°F.
Low operating cost. Low maintenance cost. Easy service.
These heaters are design certified and tested under the requirements of ANSI Z21.56 / CSA 4.7 American National Standard / CSA Standard for Gas-Fired Pool Heaters. Only Raypak offers a pool heater that is not only the most efficient (up to 82% thermal efficiency) but also includes, engineering and manufacturing innovations not found in other makes. As a result, a Raypak commercial pool heater is unmatched for heating efficiency, operating economy, low-cost installation and all-around dependability. And they are fired up and fully tested at the factory to assure their on-site performance. Check these standard features and see why Raypak is the best!
Electronic Pilot Ignition…Saves fuel, no standing pilot. 100% Copper And Bronze Waterways…Bronze headers
and cupro nickel finned tubes prevent corrosion and rust which can stain the pool and destroy the heater. 1" Diameter Finned Cupro Nickel Tubes…Better water flow, lower pressure drop through heater. Tough, Durable Polytuf Powdercoat Finish…Long-lasting all-weather protection in durable Forest Green color.
MODEL P-1336 INDOOR
Unitherm GovernorFor Models P-514 thru P-1223, a pat- ented 3-way valve built in the header, automatically maintains the water in the heater at the precise temperature that prevents condensation and scale. By-Pass Pump…For models P-1287 thru P-4001, a properly designed by-pass pump is used to control the temperature of the water entering the heater to avoid condensation and scaling. Interlocking Combustion Chamber…Cuts heat loss for best efficiency. Keeps jacket cool.
Dual Gas Valves…For safety. Stainless Steel Burners…Can't clog or corrode. Slide-out Burner Tray…For easy inspection. Protecto Vent Top (outdoor only)…Wind,rain and debris
proof.
L
W
Catalog No. 6200.10-P Effective: 12-01-07 Replaces: 05-15-03
SPECIFICATION AND DIMENSIONS
Y
MBH NATURAL GAS (X 1000) † DIMENSIONS (INCHES)
APPROX.
MODEL INDOOR OUTDOOR HEIGHT JACKET GAS WATER FLUE SHIPPING
INPUT OUTPUT INPUT OUTPUT WIDTH OVERALL HEIGHT CONN. CONN. DIA. WEIGHT
ABCG HJKL(LBS)
P-514 511.5 419.4 511.5 419.4 32-3/4 57 33 1 2 10 25-3/8 450 P-624 627.0 514.0 638.0 514.0 37-1/2 57 33 1 2 12 20-1/2 480 P-724 726.0 595.0 726.0 595.0 41-5/8 57 33 1 2 12 34-1/4 510 P-824 825.0 676.5 825.0 676.5 45-3/4 57 33 1 2 14 38-1/2 590 P-926 926.0 759.0 52-3/8 1 2 700
P-962 961.7 788.6 52-3/8 76-1/8 33-1/2 1 2 23-5/8 14 28 650 P-1083 1083.0 888.0 59-1/4 1 2 810 P-1125 1124.7 922.0 59-1/4 78-1/8 33-1/2 1 2 23-5/8 16 32 750 P-1178 1178.0 966.0 63-5/8 1 2 800 P-1223 1222.5 1002.4 63-5/8 78-1/8 33-1/2 1 2 23-5/8 16 32 855 P-1287 1287.0 1055.0 68-5/8 1-1/4 2-1/2 975 P-1336 1336.6 1096.0 68-5/8 80-1/8 33-1/2 1-1/4 2-1/2 23-5/8 18 36 970 P-1414 1413.0 1158.5 74-7/8 1-1/4 2-1/2 1065 P-1468 1467.0 1203.0 74-7/8 80-1/8 33-1/2 1-1/4 2-1/2 23-5/8 18 36 1050 P-1571 1570.0 1287.0 81-1/8 1-1/4 2-1/2 1120 P-1631 1630.0 1336.6 1758.0 81-1/8 83-1/8 36-1/2 1-1/4 2-1/2 23-5/8 18 36 1100 P-1758 1441.5 89-3/8 1-1/4 2-1/2 1140 P-1826 1825.6 1497.0 89-3/8 85-1/8 36-1/2 1-1/4 2-1/2 23-5/8 20 40 1190 P-2100 2100.0 1722.0 61 68-1/4 1-1/2 3 24 1580 P-2500 2499.0 2049.0 70 68-1/4 1-1/2 3 26 1780 P-3001 3000.0 2460.0 81-1/4 68-1/4 2 3 28 2000 P-3500 3500.0 2870.0 92-1/2 68-1/4 2 3 30 2180 P-4001 4000.0 3280.0 103-3/4 68-1/4 2 3 32 2500
Electrical Rating: 120/24V 60 Hz less than 12 amperes. Ratings shown are for elevations up to 2000 feet. Elevations over 2000 feet ratings † See gas conversion chart. should be reduced at the rate of 4% for each 1000 feet above sea level. * Manufactures rating. ‡ Note: Addition of special controls for CSD-1, IRI and others may increase gas train
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION RECOMM ENDED FLOW RATES
LEFT RIGHT TOP MODELS MINIMUM MAXIMUM
MODEL FRONT REAR SIDE SIDE INDOOR OUTDOOR P-514 TO P-1223 60 GPM 120 GPM
P-514 TO 24" 12" 6" * 6" 36" UNOBSTRUCTED P-1287 TO P-1826 SEE FLOW RATES
P-824 P-2100 TO P-4001 TABLE BELOW
P-926 TO 24" 24" 24" 24" 24" UNOBSTRUCTED
P-1826 MODELS
P-2100 T0 48" 24" 24" 24" 24" MODELS ARE 1287/1336 30-50
P-4001 INDOOR ONLY 1414/1468 35-55
* 18" REQUIRED FOR SERVICING 1571/1631 40-65
† TO CONVERT NAT. GAS MBH TO PROPANE MBH 2100 50-80
MODEL MULTIPLY NAT. MBH 3001 75-115
B P-514 TO P-824 0.94 4001 100-150 P-926 TO P-1828 0.92 INDOOR
0.955 OUTDOOR Size for maximum flow rates shown above, and
P-2100 TO P-4001 1.0 (SAME AS NAT. GAS) adjust flow to the boiler to obtain 120°F outlet water
size. Consult with the factory.
FLOW RATES (GPM)
1758/1826 45-70
2500 60-95
3500 90-135
temperature.
Loading...