ANEW ERA IN BOILER DESIGN
Commercial Space Heating and Domestic Water
ADB Advanced Design Boiler
Up to 97% Thermal Efficiency
Ultra low NOx Small Footprint Aerodynamically
Stabilized Burner Full Diagnostics
Multiple Venting Options
Reduced Vent Sizes
New!
1500 MBTU
TM
Page 2
95
100
8060 100 120 140 160
90
85
80
75
180 200 220
ADB without Condensing Heat Exchanger
ADB with Condensing Heat Exchanger
%Efficiency
°F Return Water Temperature
H
igh efficiency boilers were introduced in response to the energy crisis of the
seventies. Most first generation high efficiency boilers were simply standard units that had been hurriedly modified to boost efficiency. These boilers obtained higher efficiencies by permitting steady-state condensation in the heat exchanger and in the combustion chamber. Failure to adequately protect the combustion chamber and heat exchanger from the corrosive effects of condensate meant that most first generation units failed prematurely. The units condensed, eventually corroded, and finally were discarded.
Manufacturers learned from their mistakes. They upgraded materials, redesigned heat exchangers and refined their manufacturing techniques. The second generation of high efficiency boilers, which began to appear in the late eighties, was a vast improvement. However, second generation units still experience damage from condensation. Although the materials used in second generation high efficiency boilers last considerably longer, they still eventually succumb to corrosion.
THIRD GENERATION TECHNOLOGY
After two decades of trial-and-error, the boiler industry has finally realized that high efficiency and long product life can only be obtained by preventing condensation from occurring in the combustion chamber. Raypak’s Advanced Design Boiler is the first of a new generation of boilers that can obtain ultra-high efficiencies without compromising product life. The “secret” to the ADB’s longevity is that condensation occurs only in a corrosion-resistant condensing heat exchanger. The ADB is designed so that condensation will not occur in the primary heat exchanger or the combustion chamber. The result is an ultra-high efficiency product that lasts.
Welcome to the future of boiler technology.
Efficiencies up to
97
%
THE EFFICIENCY YOU WANT AND THE RELIABILITY YOU NEED.
EFFICIENCY
.
THE ADB’S
NON-CONDENSING
PRIMARY HEAT EXCHANGER
THE EFFICIENCY
YOU WANT
The Advanced Design Boiler is the first boiler that can meet your exact efficiency requirements. The ADB, when used without the Condensing Heat Exchanger (CHX), can deliver thermal efficiencies up to 84%.
If higher efficiency is required, simply add the Condensing Heat Exchanger to the installation. The CHX is designed to capture the maximum amount of available energy by extracting both sensible and latent heat from the flue gases. That means ultra-high efficiencies – and substantial energy savings.
AGA Design Certified Rating
Page 3
R
ELIABILITY.
ADVANCED BURNER TECHNOLOGY
The heart of any boiler is the burner. It’s a critical component that’s got to be designed right. That’s why Raypak spent over four years perfecting the ADB burner. The result is an industrial grade, fan­assisted burner that provides superior perfor­mance and is practically indestructible.
Standard high efficiency boilers use burners that are either flimsy flame retention screens that burn out, or radial perforated burners that eventually clog and operate at reduced efficiencies. Unlike these burner designs, the patented advanced
design burner will not clog or burn out. In fact,
Raypak is so confident, the new burner head is backed with a T
EN YEAR UNCONDITIONAL WARRANTY.
The ADB’s burner utilizes a solid metal bluff-body burner head to generate a high-intensity aerody­namically stabilized flame. The burner’s turbulent mixing action reduces residence time and increas­es flue gas recirculation. The result is clean, effi­cient combustion with NOx emissions well within the limits of the most restrictive air quality require­ments.*
This is one tough burner and the warranty proves it.
* NOx emissions: 0-30 ppm depending on combustion air quality and gas composition.
ERROR
HEAT
CENTRAL POINT WIRING AND DIAGNOSTICS
Raypak boilers have a well earned reputation for being easy to service. The ADB is no exception. In fact, the ADB sets a whole new standard for ser­viceability – because it’s the first commercial boiler to incorporate central point wiring (CPW).
Unlike older control technologies, CPW individually monitors each and every boiler control and safety function. Using an intuitive LED display referred to as the Operation Status Center, CPW gives split­second feedback on boiler firing status. Should service be required, the ADB will even indicate which component requires attention by illuminat­ing the appropriate fault LED located on the ADB’s U-2 Diagnostics Panel.
Page 4
F
LEXIBILITY.
THE CONDENSING HEAT EXCHANGER (CHX)
The CHX is a scavenging heat exchanger that has been specifically designed to capture the maximum amount of energy from the ADB’s exhaust gases. When used with a pre-heat tank and a storage tank, the ADB/CHX system can squeeze out an amazing 97% of all heat of combustion energy contained in the flue gases.
The CHX is built tough enough to withstand the demanding conditions found in condensing applications. All materials used in the CHX are inherently corrosion resistant and are treated with advanced corrosion­proof coatings for extra protection. The headers are bronze, the heat exchanger tubes are made of cupro-nickel and are coated with a condensate impervious epoxy enamel. All
non-stainless internal fittings are either epoxy coated or are chemically immune. The tube bundle casing is fabricated from AL29-4C stainless steel, and the outer jacket has an electrostatically applied powder coat finish that is baked-on for superior corrosion resistance and extra long life.
By segregating condensation from the primary heat exchanger and the combustion chamber, the CHX produces ultra-high efficiency without sacrificing product life.
VENTING OPTIONS
CONVENTIONAL VENT
THROUGH-WALL VENT
DIRECT VENT/SEALED
COMBUSTION
VERTICAL VENT/SEALED
COMBUSTION
OUTDOOR
Page 5
THE ADVANCED DESIGN BOILER
WEATHER PROOF JACKET
The heavy gauge steel exterior jacket is protected with a baked-on UV-resistant Polytuf powder coat finish.
COMBUSTION
AIR FAN
With easy-to-adjust combustion air shutter.
CORROSION RESISTANT STEEL
All metal fittings are galvanized against rust.
SPARK TO PILOT IGNITION
The most dependable ignition method available.
MINIMUM CLEARANCE
REQUIREMENTS
Only one inch of clearance is required from combustible surfaces.
PRIMARY HEAT EXCHANGER
Vertical, cylindrical, multi-pass heat exchanger captures all radiant energy, eliminating the need for heavy refractory.
CUPRO-NICKEL FINNED TUBES
Provide fast, efficient heat transfer with extended tube life. Will not corrode or erode and can handle aggressive and hard water with ease.
SMALL FOOTPRINT
The ADB occupies less than 51/2 sq. ft. of floor space.
VENT PRESSURE SWITCHES
Enhance safety by verifying proper
burner operation.
U
P-FRONT CONTROLS
Easy access to all controls and
gas train components.
ADVANCED BLUFF BODY
B
URNER
Industrial-tough, solid metal burner
head won’t clog or burn out –
and it’s backed with a
T
EN YEAR UNCONDITIONAL WARRANTY.
RUGGED ALL BRONZE
HEADERS
Are naturally corrosion resistant.
VENT OUTLET FLEXIBILITY
The flue gas outlet can be
repositioned in the field to vent from
either the back or right side of the unit.
TUBE SHEET CONSTRUCTION
Eliminates the repair and
maintenance problems associated
with rolling tubes directly into
a casting.
V
IEWING PORT
Allows easy fine-tuning of the power burner.
OPERATION STATUS CENTER
Central point wiring, standard operating lights,
full-boiler diagnostics.
Page 6
SHIP FOOT
MODEL INPUT OUTPUT B D E F G H K M P WGT PRINT AMPS
(MBTU) (MBTU) HEIGHT NPT NPT FLUE Lbs. Ft.
2
H 751 750 630 64 38 44-1/2 29-3/4 1-1/2 2 8 17-3/4 41 680 5.4 8 H 1001 999 840 72 46 52-1/2 37-3/4 1-1/2 2-1/2 10 21-1/2 49 720 5.4 10 H 1501 1499 1260 82 56 62-1/2 47-3/4 1-1/2 2-1/2 12 20-1/4 59 780 5.4 12
FEATURES
Advanced Fan-Assisted Burner with Aerodynamically Stabilized Flame
Design Certified ANSI Z21.13 and Z21.10.3
Ultra-Low NOx: Less than 30ppm
Reduced Footprint
Indoor/Outdoor Construction
Thermal Shock Resistant
20 Year Limited Warranty
Natural Gas or Propane (except 1501)
STANDARD EQUIPMENT
HEAT EXCHANGER
Bronze Headers
Integral Finned Tube Heat Exchanger Copper For Type H4 Cupro-Nickel For WH1
ASME Inspected and Stamped 150 PSIG
National Board Approved
Factory Installed ASME Relief Valve
Te mperature and Pressure Gauge
GAS CONTROL TRAIN
Manual Main Gas Shut-Off Cock
Main Gas Pressure Regulator
Safety Shut-Off Valve, Redundant
Firing Mode: On/Off
Factory Fire Tested
CSD-1 Compliant Gas Train
CONTROLS
120V, 60Hz, 1ø Power Supply
120/24V Transformer
100% Pilot Safety
Electronic Intermittent Ignition (IID)
High Limit Safeties
Central Point Wiring
Full Boiler Diagnostics
Fan Proving Switch
Flow Switch
Blocked Flue Switch
CONSTRUCTION
Front Controls: Enclosed
Polytuf Powder Coat Finish
Durable Indoor/Outdoor Construction
Right Side or Rear Connections
Dimensions are in inches. Ratings shown for elevations up to 5000 feet. For installation at elevations over 5000 feet, please contact manufacturer. See catalog 2000.27 for complete installation dimensions.
RAYPAK CORPORATE OFFICE AND PRINCIPAL MANUFACTURING FACILITY
2151 Eastman Avenue Oxnard, CA 93030 (805) 278-5300 FAX: (800) 872-9725
RAYPAK CANADA LIMITED 2805 Slough St., Mississauga Ontario, Canada L4T 1G2 (905) 677-7999 FAX: (905) 677-8036
Raypak, Inc. reserves the right to make product changes or improvements at any time without notice
Catalog No. 3400.10G Effective: 07-15-03 Replaces: 07-01-01 Litho in USA ©1998-2001 Raypak, Inc.
www.raypak.com
Loading...