Raypak H-0042B Installation Manual

USER’S INFORMATION MANUAL
CATALOG NO. 2100.51L Effective: 09-19-08 Replaces: 04-10-08 P/N 240490 Rev. 13
Models
0042B, 0066B, 0090B, 0135B,
0180B—Type H
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Gas Fired Residential
Heating Boilers
2
Introduction
This User's Information Manual is provided with the necessary information for the proper operation and maintenance of these Raypak boilers. Please review and follow these procedures carefully. Keep this man­ual in a safe and accessible place for easy reference in the future.
Blocked Vent Shut-Off System
This boiler is equipped with a blocked vent shut-off system designed to shut off main burner gas in the event the venting system is totally blocked. In the event the blocked vent shut-off system is actuated, do not attempt to place the boiler in operation, contact a qualified service agency.
Flame Roll-Out Safety Shut-Off System
This boiler is equipped with a flame roll-out safety shutoff system designed to shut-off the main burner gas in the event of sustained flame roll-out. In the event the flame roll-out safety system is actuated, do not attempt to place the boiler in operation, contact a qualified service agency.
Lighting Instructions For Standing Pilot Models
Some safety information you need to read and under­stand before operating the boiler.
A. This boiler has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING Smell all around the boiler area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach you gas supplier, call the fire department.
C. Use only your hand to push in, move or turn the gas control knob or lever. Never use tools. If the knob or lever will not push in, move or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this boiler if any part has been under water. Immediately call a qualified service technician to inspect the boiler and to replace any part of the con­trol system and any gas control which has been under water.
For Standing Pilot Models with Robertshaw Gas Valve, 2-Stage Operation. (Models 90, 135 & 180)
5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above in this manual. If your don't smell gas, go to the next step.
6. Locate pilot mounted on the right side of the burn­er drawer, and right of first burner.
WARNING: Improper care and maintenance of flue and venting system can cause a hazardous condition which may result in injury, property damage or loss of life.
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
NOTE: Lever cannot be moved from "ON" to "OFF" unless lever is pushed in slightly. Do not force.
Fig. 1: Gas Control Lever
1. STOP! Read the safety information.
2. Set the thermostat to the lowest setting.
3. Turn off all electric power to the appliance.
4. Push in and move gas control lever counter­clockwise to "OFF" position.
GAS CONTROL LEVER SHOWN IN "OFF" POSITION
GAS INLET