Raypak H-0042 User Manual

RESIDENTIALS
Inputs from
42,000 thru 180,000BTUH
• Radiant Heating
• Hydronic Space Heating
• Snow Melting
FFiirriinngg MMooddee
Models 42 & 66 – Single-stage firing Models 90-180 – 2-stage firing
NNoonn--CCoonnddeennssiinngg
Operates at 105 °F return water temperature without condensing – perfect for the low­temperature needs of radiant floor and snow melting systems
BBuuiilltt--IInn PPuummpp aanndd BByyppaassss
Offers maximum application flexibility
HHoonneeyywweellll IIIIDD IIggnniittiioonn
Standard S8600 IID eliminates off-cycle fuel consumption; Standing pilot available on Models 90-180
SSppaarrkk--TToo--HHoooodd PPiilloott
Eliminates erratic pilot ignition and lockout
MMoottoorriizzeedd VVeenntt DDaammppeerr
Prevents heat loss during off-cycles
NNoonn--FFeerrrroouuss WWaatteerrwwaayyss OOppttiioonn ((SShhoowwnn))
All stainless steel pump, brass fittings and glass-lined headers eliminate boiler oxygen permeation problems associated with non-barrier radiant tubing
OOuuttssttaannddiinngg WWaarrrraannttyy
One-year parts and service warranty against defects
Residentials - Models 42 – 180
ledoM
t
upnI
HUTBMHUTBM
H
UTBM
HUTBMHUTBM
gnitaeH
y
ticapaCyticapaC
yticapaC
y
ticapaCyticapaC HUTBMHUTBM
H
UTBM
HUTBMHUTBM
teN
retaWretaW
retaW
retaWretaW g
nitaRgnitaR
gnitaR
g
nitaRgnitaR
HUTBMHUTBM
H
UTBM
HUTBMHUTBM
gnipiP
snoitcennoCsnoitcennoC
snoitcennoC
snoitcennoCsnoitcennoC
B
tneV
retemaiD
K
xorppA
gnippihSgnippihS
gnippihS
gnippihSgnippihS
t
hgieWthgieW
thgieW
t
hgieWthgieW )sbl()sbl(
)
sbl(
)sbl()sbl(
secnaraelC
r
etaW TPNTPN
T
PN
TPNTPN
s
aG
TPNTPN
T
PN
TPNTP
oolFtnorFraeR
t
hgiR
ediSediS
e
diS
ediSediS
t
feL
ediSediS
e
diS
ediSediSpoT
e
ulF
tneVtneV
t
neV
tneVtneV
2400-H245303"1"2/1"2/15"459elbitsubmoC"4"6"6"6"61"6
6600-H664574"1"2/1"4/35"5501elbitsubmoC"4"6"6"6"61"6
0900-H094746"1"2/1"4/35"5501elbitsubmoCevoclA"6"6"6"61"6
5310-H53190159"4/11"2/1"4/16"6531elbitsubmoCevoclA"6"6"6"61"6
0810-H081841921"4/11"2/1"8"7041elbitsubmoCevoclA"6"6"6"61"6
Fig # 8978.2
0042 thru 0090 0135 thru 0180
Fig # 8978.5
AAFFUUEE RRaattiinnggss
Tested with IID ignition and vent damper.
MMooddeell AAFFUUEE
H-0042 84.0 H-0066
83.0 H-0090 83.0 H-0135 83.0 H-0180 83.0
Results for standing pilot models available.
Ratings shown are for elevations up to 2,000 feet. For elevations over 2,000 feet, ratings should be reduced 4% for each 1,000 feet above sea level. A front clearance of at least 24 inches is recommended for adequate service of burner tray and controls. Circulator provided is not always suitable for systems having high resistance. Consult data sheet for maximums. Complete installation dimensions available, see catalog # 2100.20.
TThhee RRaayyppaakk RReessiiddeennttiiaallss
With five sizes to choose from, there is a copper fin tube Residential for every home, apartment or condominium. Small enough to fit almost any space and fuel efficient for utility savings. Easy to install and service because it’s complete right out of the box. Reliable because it’s a Raypak.
SSaaffee
• Over-temperature protection device with LED
display instantly shuts down boiler in a no-flow condition.
• Safety featur
es shut boiler down in the event of
a blocked flue or heat exchanger.
• ASME heat exchanger is inspected and stamped
for 160 psi operating pressure.
EEaassyy ttoo IInnssttaallll
• Lightweight; All sizes transportable by one person.
• W
eight of the largest model is 140 lbs., compared to an equivalent cast iron boiler at over 300 lbs.
• One carton contains all components.
• Piping and wiring located at front.
• 30 psi pressure relief valve.
Raypak, Inc. reserves the right to make product changes or improvements at any time without notice. Catalog No.: 2100.10-Q Effec tive: 07-15-10 Replaces: 11-15-09 Litho in U.S.A. ©2007 Raypak, Inc.
22115511 EEaassttmmaann AAvveennuuee ••OOxxnnaarrdd,, CCAA 993300330
RRaayyppaa kk,, IInncc..
880055--227788--55330000 •• FFaaxx 880000--887722--9977225
wwwwww..rraayyppaakk..ccoom