Raypak E-4 User Manual

E–4 Swimming Pool
Heater Alarm
with Status Indicator Lights and Alarm Bell
The E–4 Alarm is a solid state electronic status indicator and alarm that has been engineered to simplify troubleshooting and minimize down time.
Features
Solid State Electronic Circuit Board
Electronic Alarm Buzzer Standard
Alarm Silencing Switch
Operating and Fault LED's (Light Emitting Diodes)
Power - Green Pilot - Amber Main Gas - Green Safety Shutdown - Red Auxiliary Alarm - Red
Auxiliary Alarm Option
Optional Remote Alarm Panel
Monitors 24 or 120 VAC Inputs
Heater or Remote Mounted
Rainproof Gasketless Enclosure
UL and cUL Listed
Illinois State School Code Compliant
One Year Limited Warranty
Designed and manufactured by Raypak, the E–4 Swimming Pool Heater Alarm is another example of innovation from your "Heater Company".
Raypak, Inc. reserves the right to make product changes or improvements at any time without notification.
Optional Remote
Alarm Panel
Catalog No. 6000.43B Effective: 12-28-07 Replaces: 12-15-99
System Characteristics
Control
Solid State Electronic Circuit Board
Front Panel Indicator Lights
Power - Green Pilot - Amber Main Gas - Green Safety Shutdown - Red Auxiliary Alarm - Red
Alarms
Mechanical Alarm Bell (3" Standard/4" Option) Electronic Alarm Buzzer Auxiliary Alarm Option:
Adjustable Time Delay: 5 - 60 secs.
Momentary Alarm Silencing Switch
Remote Alarm Panel (Optional)
Electric Alarm Buzzer and Indicating Light Remote Alarm Silencing Switch Mounts with 4" X 4" Duplex Box Mountable up to 500' Away
Electrical Characteristics
Power: 120 VAC, 0.25A, 60 Hz Monitors: 24 or 120 VAC
Ambient Conditions
Temperature: -40 to 175°F Humidity: Non-condensing to 90% RH
Interoperability
Integrates with all Raypak Boilers and Controls
Enclosure
NEMA 3R Rainproof 8-1/2W x 10H x 7D Gasketless Door Vandal Resistant Design Left, Right or Rear Mounting Boiler or Remote Mounted
Limited One Year Warranty
U
L
®
Sample Specification
Provide the Raypak UL Listed E–4 Swimming Pool Alarm that shall monitor and give indication of an alarm condition affecting its associated Swimming Pool Heater. The alarm module shall be solid state and shall be capable of processing either 24 VAC or 120 VAC inputs.
It shall be equipped with LED's (Light emitting diodes)that indicate a signal present and shall be color coded as listed below:
Power Green: indicating the alarm unit is receiving power. Pilot Amber: indicating the pilot gas valve is open. Main Gas Green: indicating the main gas valve is open. Safety Shutdown Red: indicating that a safety shutdown has occurred. Auxiliary Alarm Red: (Optional Aux. Alarm) indicating that a safety shutdown has occurred after a
built-in user adjustable time delay has expired.
A 3" diameter and 4" diameter mechanical bell and a modulating electronic alarm buzzer shall sound when an alarm condition occurs. A momentary switch shall silence the alarm bell and buzzer. The alarm signal will automatically reset once the alarm condition has been corrected.
Provide a remote alarm panel with indicating light, electronic alarm buzzer and remote silencing switch. The remote alarm panel shall mount in a 4" X 4" junction box up to 500 feet away from the alarm control panel.
C
U
®
L
The alarm module shall be suitable for wall or heater mounting up to 20 feet away from the associated heater and shall be enclosed in a NEMA 3R rated rainproof enclosure. The enclosure shall be vandal resistant and shall be of a gasketless mechanical seal design.
The alarm and heater shall be manufactured by the same company and shall carry single source responsibility.
Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX: (800) 872-9725