Raypak 42-180 User Manual

Page 1
Raypak Residential Products
Page 2
Raypak’s Residential Boiler Product Family
Raypak revolutionized the boiler market in 1948 with the first innovative high recovery boilers that utilized superior finned
opper tube material. Our successful designs became the bench-
c mark by which all other boiler designs were judged for efficient, reliable and durable hydronic heat.
At that time, Raypak was the first American manufacturer to provide an innovative family of heating products that used supe­rior copper and bronze materials in the construction of their heat exchangers. Up until that time, all manufacturers used energy wasteful high mass cast iron and steel in the construc­tion of heat exchangers.
We direct our Engineers to consider innovation of a new func­tion or feature into the boiler’s basic design to be a requirement of every new product. Additionally, the innovative feature pro­vided to the end user in a manner that is apparent and benefi­cial to the user, rather than as an unfathomable abstraction.
For over half a century, Raypak has led the trade with innovative boilers that utilized finned copper tubes as the primary material of choice for heat exchangers. Raypak has found the necessity to increase choices in materials, so that copper, as well as aluminum alloys are available for the construction of heat exchangers that are suitable for any application or environment.
Recent legislative activity throughout the Unites States, where Municipal, State and Federal Governments have created various incentive and rebate programs in order to lower non-renewable energy consumption at the consumer level. In the process, these incentives have enhanced the marketplace for higher efficiency boilers.
Raypak’s family of Hydronic boilers allows every homeowner’s possible needs to be satisfied. Raypak provides easy, reliable sin­gle source provision of modern, Energy Star listed designs made in the USA or Europe that are backed up with the best service and support network in the trade.
This brochure features three Raypak families of residential boil­ers, ranging in size from 42,000 to 300,000 Btu. The specific con­struction varies. However, all product lines are at the cutting edge of operating efficiency feasible for their particular design. This ranges from 83% AFUE for the reliable and time proven Raytherms, to the mid 90's for the condensing versions in which­ever size fits your needs. Choose a hydronic system to maximize your family's comfort, and select whichever Raypak model best meets your individual preferences from this complete array.
Raytherm
Hi Delta ss
XPak
Page 3
Extruded Aluminum Heat Exchanger
®
he XPak utilizes an extruded, single tube design made of 6063-
T T1 aluminum alloy for the heat exchanger. The pressure vessel is rated for 45PSIG and is ASME stamped and National Board regis­tered. With over 250,000 units sold through-out Europe, you can depend on many years of trouble free operation. That’s what makes this boiler a Raypak!
Up to 4.4:1 Modulation
Infinitely modulating condensing design meets or exceeds Energy Star requirements. Zero governor gas valve with negative pressure gas regulator allows for greater installation flexibility in areas with low gas pressures. Burner is made from high grade, perforat­ed stainless steel.
3-Speed Non-Ferrous Pump
Factory installed circulator with bypass and condensate siphon. Thermostatically controlled circulator maintains proper flow through the boiler.
Models 85 and 120
Electronic Direct Spark Ignition
Software controlled and monitored ignition device allows for up to 5 tries to ignite before lock-out condition is authorized.
Natural Gas or Propane
Propane conversion kit is shipped with every unit.
Easy to Install
Inlet and outlet water connections, gas and electrical connec­tions and condensate drain are located on the bottom. Venting on the top allows this compact and lightweight boiler to mount easily onto walls without heavy bracing.
3” Venting - Flexible Options
AL29-4C Stainless steel
Polypropylene plastic
CPVC plastic vent
Concentric vent or twin penetrations
Horizontal or vertical vent
Direct vent ready
Common vent with multiple units when used with ULC 636
listed vent systems and in accordance with the installation and operating manual
The XPak boiler qualifies for the 2010 IRS Federal tax credit, and may also qualify for your State's credits and rebates. visit www.raypak.com. Click on the "utility rebates" page. There are several tables and charts for each program by state. There are links to each state's energy website. The information posted should help verify and identify the pro­grams that are available in your area.
Page 4
5-1/2”
(140 mm)
8-5/8”
(
219 mm)
30-3/4”(781 mm)
Gas 6-13/16”(173 mm)
Water 4-7/8”(124 mm)
1
4-1/8”(359 mm)
XPak 85 = 15-3/4” (400 mm)
XPak 120 = 17-3/4” (451 mm)
30-3/4” (781 mm)
1” (25 mm)
XPak 85 = 3-15/16” (97mm)
XPak 120 = 4-1/2” (114 mm)
1
” (25 mm)
XPak Technical Data
Dimensions and connections XPak models 85 and 120
MBTUH Output*
XPak
Model
BO IL ER
85 87 80 68,000 15 -3/4 3/4” 3/4” 3” 73 1.20
MBTUH
Input*
Heating Capacity
MBTUH
Net I=B=R
MBTUH
Width
Dimensions (in.)
Gas NPT
Water
NPT
Vent
Diameter
Operating
Weight
120 120 111 94,000 17 - 3/4 3/4” 3/4” 3” 80 1.25
* Ratings for models natural or propane gas and for elevations up to 2,000 ft. above sea level . For higher elevations, consult the factory.
(PSI)
Full Load
(Lbs/Hr)
Flue Gas Mass
Flow Rate
Partial Load
(Lbs/Hr)
Condensate Flow Rate
86°F Return
Full Fire GPH
Firing
Flow Rates
Xpak
Model
BO ILER
** Minimum flow rate may vary. See manual for details on pump performance settings, and residential head.
AFUE
%
Min.
GPM
85 91.8 3.0** 5.7 .85 25,600 87,000 6.5 45 90.4 26.6 0.37 0.13 120 92.6 3.5** 6.2 1.0 27,300 119,500 6.5 45 123.2 28.5 0.41 0.16
Max. GPM
Content
Gallons
Water
Min.
(BTU/Hr)
Rate
Max.
(BTU/Hr)
Operating
Pressure
Min. (PSI)
Max.
Amps
(lbs.)
86°F Return
Min Fire GPH
Page 5
Models: HD101R thru HD301R
®
SSSS
Raypak’s Hi Delta ss
Decades of expertise and technological innovations went into creating the Hi Delta ss boiler, a product that incorporates fea­tures sought after by engineers, installers and end-users alike.
In 1948, Raypak introduced the first straight copper finned tube boiler designed with reliability and serviceability in mind. The tradition continues with Raypak’s Hi Delta ss model. It’s patented burner “security blanket,” an ingenious enhancement that pro­vides a perfected air-gas pathway for complete combustion, makes the Hi Delta ss the most adaptable sealed-combustion boil­er on the market today.
While many manufacturers claim simple, convenient heat exchanger removal, servicing the Hi Delta ss couldn’t be more straightforward. Just remove the top cover and flue collector and it lefts right out.
When installed indoors, the Hi Delta’s versatility is revealed in smaller vent diameters, direct-venting and the convenience of stacking without an increased footprint.
Raypak’s focus on customer satisfaction goes beyond product design. Like all Raypak boilers, every Hi Delta ss is factory-fire tested, assuring reliable start-up upon installation.
For over 60 years, Raypak professionals have earned their reputa­tion as The Hot Water Management Experts. From system design through installation and start-up, you can count on your local Raypak Representative and the backing of the industry’s best sales staff, applications engineers and service department.
Options
A-6 – Right hand water connection
S-1 S-2 High and low gas pressure switches
Digital controller
Outdoor reset
DHW boost function
Key Features
5 models from 100,000 to 299,000 BTUH
All models indoor/outdoor certified
Efficiency:
85% AFUE HD101-HD301
Patented burner “security blanket” enhances
combustion, minimizes installation and start-up issues, and protects burners from metal fatigue
105ºF minimum inlet water capability
Copper finned tube heat exchanger; Cupro-nickel available
Sidewall venting ready; No extractor needed for
most applications
Ducted combustion air ready; TruSeal
direct-vent ready
TM
CSA-certified
Meets all current and pending NOx air quality regulations
Integral combustion air filter
Page 6
®
SSSS
P
OWER
ON
CALL FOR
HEAT
BURNER
FIRING
S
ERVICE
REQUIRED
OFF
P
/N 901927 REV 1
MODELS HD101-HD301
MANUAL SHUT-OFF & DIAGNOSTIC LIGHTS
H WATER IN
G G
AS CONNECTION
LOW VOLTAGE CONNECTIONS
H WATER OUT
8-7/8
O
PTIONAL PUMP
A
B
K FLUE CONNECTION DIA.
T CO MBUS TIO N AIR DI A.
L
INE VOLTAGE CONNECTIONS
26-3/8
1
9-7/16
1
6-9/16
1-1/4
5-1/16
18-1/4
8-1/2
19-3/8
22-1/8
2
3-1/2
2
6
4-9/16
SEE
PUMP
CHART
1
°
SLO
P
E
O
N
J
A
C
K
E
T
T
O
P
4-15/16
13-1/2
Hi Delta ss Technical Data
Hi Delta
Model
HD101 100 85 18-9/16 9-1/4 3/4 1-1/2 44150 4.7
BO IL ER
HD151 150 128 21-7/8 10-7/8 3/4 1-1/2 44175 4.7 HD201 199 169 25-1/16 12-1/2 3/4 1-1/2 54200 4.7 HD251 250 213 28-5/16 14-1/8 3/4 1-1/2 54225 4.7 HD301 299 254 31-9/16 15-3/4 3/4 1-1/2 54250 4.7
* Ratings for models HD101-HD301 for natural or propane gas and for elevations up to 2,000 ft. above sea level . For higher elevations, consult the factory. ‡ Current draw is for heater only. (Supply breaker must have a delayed trip.)
Hi Delta
Model
GPM
HD101 13 0.7 14 44 8.8 4 17 1.4 HD151 13 0.7 20 44 8.8 6 26 3.1 13 1.0 HD201 13 3.4 27 44 8.9 8 34 5.4 17 1.3 HD251 13 0.7 34 44 9.2 10 43 8.5 21 2.1 14 0.9
85 % A FU E
HD301 13 0.7 41 44 9.4 12 25 3.1 17 1.4 13 0.7
MBTUH
Output*
Input*
Minimum Flow
P Ft T °F
MBTUH
Type H
(Cat. I)
Flow Rates
A
Width
Maximum Flow
GPM
P Ft T °F
Dimensions (in.)
B
G
NPT
10°F T
GPM
P Ft
NPT
20°F T
GPM
H
Pressure Drops
P Ft
K
Flue Ø
GPM
T
Ø
P Ft
Operating
Weight
(lbs.)
40°F T30°F T
GPM
Amps
P Ft
Less than Minimum Flow
Exceeds Maximum Flow
Page 7
Firing Mode
®
Models 42 & 66 – Single-stage firing Models 90-180 – 2-stage firing
Non-Condensing
Operates at 105 °F return water temperature without condensing perfect for the low-temperature needs of radiant floor and snow
melting systems
Built-In Pump and Bypass
Offers maximum application flexibility
Honeywell IID Ignition
Standard S8600 IID eliminates off-cycle fuel consumption; Standing pilot available on Models 90-180 only
Models 42 – 180
“Spark-To-Hood” Pilot
Eliminates erratic pilot ignition and lockout
Motorized Vent Damper
Prevents heat loss during off-cycles
Built-in low profile draft hood
Fits into tight spaces
Non-Ferrous Waterways Option
All stainless steel pump, brass fittings and glass-lined headers eliminate boiler oxygen permeation problems associated with non­barrier radiant tubing
Outstanding Warranty
One-year parts and service warranty against defects
The Raytherm Residentials
With five sizes to choose from, there is a copper fin tube Residential for every home, apartment or condominium. Small enough to fit in almost any space and fuel efficient for utility sav­ings. Easy to install and service because it’s complete right out of the box. Reliable because it’s a Raypak.
Radiant Heating
Hydronic Space Heating
Safe
Over-temperature protection device with LED
Instantly shuts down boiler in a no-flow
condition.
Safety features shut boiler down in the event of
a blocked flue or heat exchanger.
ASME heat exchanger is inspected and stamped
for 160 psi operating pressure.
30 psi pressure relief valve.
Available with or without pump.
Easy to Install
Lightweight; All sizes transportable by one
person.
Weight of the largest model is 140 lbs.,
compared to an equivalent cast iron boiler at over 300 lbs.
One carton contains all components.
Piping and wiring located at front
A line of boilers that are perfect for residential and light com­mercial applications. Crafted with Raypak’s proven copper finned tube and cast iron headers, ASME heat exchanger and stainless steel burners, backed up with Raypak’s unmatched warranty.
Snow Melting
Light Commercial
Multiple Boilers
Indirect Fired Water Heating
(with indirect storage tank)
Page 8
Raytherm Technical Data
AFUE Ratings
Tested with IID igni­tion and vent damper.
Model AFUE
H-0042 84.0 H-0066 83.0 H-0090 83.0 H-0135 83.0 H-0180 83.0
Results for standing pilot models available
0135 thru 0180
Dimensions (in.)
Water
NPT
Operating
Vent Diameter
Raytherm
Model
0042 thru 0090
MBTUH
Input*
MBTUH Output*
Heating Capacity
MBTUH
Net I=B=R
Raiting MBTUH
Gas NPT
H-0042 42 35 30 1/2” 1” 4” 99 <3
BO IL ER
H-0066 66 54 47 1/2” 1” 5” 109 <3 H-0090 90 74 64 1/2” 1” 5” 109 <3 H-0135 135 109 95 1/2” 1 - 1/4” 6” 139 <3 H-0180 180 148 129 1/2” 1 - 1/4” 7” 144 <3
* Ratings for models natural or propane gas and for elevations up to 2,000 ft. above sea level . For higher elevations, consult the factory.
Operating
Pressure
Min. (PSI)
Max.
(PSI)
Raytherm
Model
AFUE
(%)
Water
Content
Gallons
Min.
(BTU/Hr)
Firing
Rate
Max.
(BTU/Hr)
Weight
(lbs.)
Amps
H-0042 84 0.5 42,000 42,000 12 160
BO ILER
H-0066 83 0.7 66,000 66,000 12 160 H-0090 83 0.7 45,000 90,000 12 160 H-0135 83 1.0 67,500 135,000 12 160 H-0180 83 1.0 90,000 180,000 12 160
Visit our website at www.raypak.com to find the Raypak representative in your area. Cat. 1100.13 09-15-10 Replaces New
Loading...