Ravenheat CSI PRIMARY AAA User Manual

ESCAPE OF GAS
Should a gas leak be suspected, contact your gas supplier without delay . Do NOT search for gas leaks with a naked fl ame.
WARNING: This appliance must be earthed. Do not touch or tamper with this sealed unit or its components.
1 INTRODUCTION
1.1 Please carefully read information given in the booklet to help you again maximum control from your appliance with minimum trouble and cost.
1.1.1 Y our Ravenheat Condensing Boiler has been designed to supply your Central Heating reqirements.
PLEASE NOTE Due to the high ef ciency and resulting low ue
gas exhaust temperature a white plume of condensation vapour (cool steam) will be emitted from the fl ue outlet terminal, this is quite normal. It will be particularly evident during periods of low outdoor temparatureor when the boiler is working at its optimum performance.
1.2 CLEARANCES AROUND THE BOILER Above 125 mm ( 5 inches) Below 150 mm ( 6 inches) Front 450 mm (18 inches) Sides 5 mm (0.2 inches) 25mm (1inch) in front when installed in a cupboard.
1.2.1 Minimum clearences are required for safety and maintenance. Do NOT obstruct any purpose
made ventilation opening if boiler has been tted in a compartment.
Never hang clothes,ect, over the appliance
1.3 USER CONTROLS (Fig.1)
1.3.1 This appliance is designed to operate with the
minimum of attention by the User. All the controls are to be found on the control pannel.
1.4 OPERA TING SAFETY CHECKS T O PROTECT
YOUR APPLIANCE
1.4.1 Before lighting the Appliance check that the
Central Heating system is charged with water within the system.
If it is a pressurised system, check that the bar
gauge is not below 1.
1.4.2 A RED warning light on the control panel warns
of a fl ame failure of the burner. This can be reset pressing on/ off switc.
1.4.3 A RED warning intermittance light on the control
panel warms of a high temperature lockout on the overheat thermostat. This could occur due to air or poor circulation in the boiler.
This can be reset manually by pressing on/
off switch. If lockout should persist leave the applliance shut down and consult your installer/ service engineer immediatly.
1.4.4. The CSI Primary condensing boiler is fi tted with
a condensate outlet whitch must be connected by the installer to a suitable discharge point as specifi ed in the installation manual. On no account should this discharge pipe be blocked or modifi ed.
USER’S GUIDE
CSI PRIMARY AAA
CONDENSING PRIMARY INNOVATION SUPER HIGH EFFICIENTY AUTOMATIC
MODULATING BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER
It is the law that all gas appliances are installed by a competent person, in accordance with the gas safety installation and use current regulations. To the current Gas Safety (Installation and Use) Regulations B.S.5440:2-(2000).
All CORGI registered installers carry a CORGI ID card and have a registration number. Both should be recorded in your boiler Log book. You can check your installer by calling CORGI direct on 01256 732300.
1
3.5 TO SHUT DOWN THE APPLIANCE
3.5.1 For long periods, switch on/off switch to off. For long periods switch of the on/off switch. If the appliance is to be shut down for long periods when there is a risk of freezing, then appliance should be drained . Similar refi lling must be done by a competent person following approved procedure.
4 CLEANING OF APPLIANCE OUTER
CASING
4.1 Use a clean damp cloth. Do not use any
abrasive cleaners and with a dry cloth lightly polish to protect painted surfaces. Control Panel and fi xiture can be wiped with damp cloth and dried . Spray polishes must not be used on control panel surfaces or switches. Care must be taken in preventing any liquids entering the appliance.
5 CARE OF YOUR APPLIANCE AND
SYSTEM
5.1 Annual servicing of your appliance is required
to maintain safety and effi ciency of its operation. Therefore it is reccommended that the appliance is serviced at least once a year and that the whole of the Heating System be checked at the same time by a qualifi ed installer. If it is know or suspected that a fault exists on the boiler then it MUST NOT be used untill the fault has been corrected by a COMPETENT PERSON. It is essential that the Instructions in this booklet are strictly followe for safe and economic operation of the boiler.
SERVICING SHOULD BE CARRIED OUT BY A QUALIFIED INSTALLER.
Ravenheat Manufacturing Ltd Chartists Way , Morley , Leeds LS 27 9ET.
2 OPERA TING DOMESTIC HOT WATER
2.1 Temperature of domestic hot water can be
varied by djusting the water.
Thermostat will control maximum temperature
leaving the appliance.
The knob can be set between minimum and
maximum appoximately 40° to 85°.
For min./ max temperature of domestic hot
water it may be necessary to set external thermostat.
3 OPERA TING HEATING AND HOT WATER
3.1 Push on/ off switch in on position.
3.3 Switch on timeclock, adjust room stat and/or thermostatic radiator valves to high settings in case they are connected.
3.3 Burner will operate, temparature output of Central Heating can be adjusted by Central Heating Control Knob. The Knob can be set between minimum (40°C) and Maximum (85°C).
Adjust external controls required settings. The optimum thetmostat setting (condensing
mode) is when the thermostat are set between 60/65°. The optimum thermostat setting for condensating heatin mode is marked by a line on the thermostat heating panel. However, consideration will need to be given to
temperatures of heat required for radiators to
give adequate, comfortable room temperatures.
The overrun thermostat will keep the pump
running when the boiler shuts down, so long as the temperature within the boiler is above a predetermined level.
3.4 TO SHUT DOWN THE APPLIANCE
3.4.1 For long periods, switch on/off switch to off.
For long periods switch of the on/off switch. If the appliance is to be shut down for long periods when there is a risk of freezing, then appliance should be drained . Similar refi lling must be done by a competent person following approved procedure.
2
Loading...
+ 2 hidden pages