Ravenheat CSI 120 User Manual

4 (1)

CONDENSING LOW NOX SYSTEM INNOVATION SUPER HIGH EFFICIENTY AUTOMATIC MODULATING COMBINATION BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER

USER’S GUIDE

CSI 120/ 150 (T) Low Nox (with or without built in timer)

It is the law that all gas appliances are installed by

1.2 CLEARANCES AROUND THE BOILER

 

a competent person, in accordance with the gas

Above 125 mm

( 5 inches)

 

safety installation and use current regulations.To

Below 150 mm

( 6 inches)

 

the current Gas Safety (Installation and Use)

Front

450 mm (18 inches)

 

Regulations B.S.5440:2-(2000).

Sides

5 mm (0.2 inches)

 

 

All CORGI registered installers carry a CORGI ID card and

25mm (1inch) in front when installed in a cupboard

 

have a registration number. Both should be recorded in your

1.2.1 Minimum clearences are required for safety and

 

boiler Log book. You can check your installer by calling

 

CORGI direct on 01256 732300.

maintenance. Do NOT obstruct any purpose made

 

 

 

 

ventilation opening if boiler has been fitted in a

 

 

 

 

compartment.

 

 

 

 

 

Never hang clothes,ect, over the appliance

 

 

 

 

1.3 USER CONTROLS (Fig.1)

 

ESCAPE OF GAS

 

1.3.1 This appliance is designed to operate with the

 

 

minimum of attention by the User. All the controls

 

Should a gas leak be suspected, contact your gas

 

are to be found on the control panel.

 

supplier without

delay.

 

 

 

 

 

Do NOT search for gas leaks with a naked flame.

1.4 OPERATING SAFETY CHECKS TO PROTECT

 

WARNING: This appliance must be earthed. Do not touch

YOUR APPLIANCE

 

or tamper with this sealed unit or its components.

 

 

 

 

1.

INTRODUCTION

1.4.1 Before lighting the Appliance check Central Heating

 

system pressure (Fig.1 item 7) is not less than 1

 

1.1 Please carefully read information given in the booklet to

bar. If it is below this do not light but consult your

 

installer about refilling your system as you may

 

 

help you again maximum control from your appliance

have a leak .

 

 

 

with minimum trouble and cost.

1.4.2 In the event of malfunction of the appliance will be

 

1.1.1 Your Ravenheat Condensing Low Nox Combination

indicate by the relevant error code (Table1) on

 

Digital Display of the control panel (Fig.50).

 

 

Boiler has been designed to supply your Central

These can be Reset by press a RESET button .

 

 

Heating and

Domestic Hot Water directly from one

If lockout code persist leave the appliance shut

 

 

unit. When Central Heating is operating, the circulation

down and consult your installer/service

 

 

will be interrupted when Domestic Hot Water is being

 

 

 

 

 

 

 

 

 

 

drawn off.

 

Table 1

 

 

 

 

This will normally not affect the level of Heating.

 

 

 

 

01: Lock out from the Flame Control Unit

 

 

PLEASE NOTE

 

 

 

Due to the high efficiency and resulting low flue gas

02: Flue System obstruction

 

 

exhaust temperature a white plume of condensation

04: Overheat Lockout

 

 

vapour (cool steam) will be emitted from the flue outlet

06: Open or short circuit on Sanitary probe

 

 

terminal, this is quite normal. It will be particularly evident

 

 

during periods of low outdoor temparatureor when the

12: Open or short circuit on Heating probe

 

 

boiler is working at its optimum performance

14: Flame simulation on Flame Control Unit

 

 

(Plume Management kit is available on request)

17: Fault on Fan Control

 

 

IMPORTANT : In the event of overheat of flue gas

28: Water Flow Switch Fault or low pressure

 

 

exhaust temperature, for to prevent malfunction of the

 

 

in the heating system

 

 

appliance, boiler will be stop to operate.

 

 

 

 

30: Flue temperature fault

 

 

 

 

 

 

 

1

 

 

 

 

 

Ravenheat CSI 120 User Manual

Fig.1

min Max min Max

2.OPERATING DOMESTIC HOT WATER

2.1Select summer / Winter switch on Summer position

2.2Open hot water tap. After about 3 seconds burner will always operate.

2.3Temperature of Domestic Hot Water can be varied by adjusting the water flow rate at the Domestic Hot water The temperature can be set between minimum (40°C) and Maximum (60°C).

For maximum temerature of Domestic Hot Water leave the control Knob on Maximum position.

3.OPERATING HEATING AND HOT WATER

3.1TO SET AND ADJUST BUILT-IN TIMER MODEL SEE OPPOSITE PAGE 3

3.2Select Summer/Winter Switch on Winter position

3.3Switch on timeclock, adjust room stat and/or thermostatic radiator valves to hogh settings

3.4Burner will operate, temparature output of Central Heating can be adjusted by Central Heating Control Knob (Fig.1). The Knob can be set between minimum (40°C) and Maximum (85°C).While the

appliance is being used to provide Domestic Hot water, the Central Heating will not operate.When Domestic Hot Water is not longer required the appliance will automatically revert to Central Heating and should not noticeably affect the level of central heating.

Adjust external controls required settings.

NOTE : An Anti-cycling device is fitted to the Heating Function. When the boiler reaches its set Maximum temperature it will not operate on heating for about 10 minutes , but if the heating temperature return goes 20°C below the set point, the burner will restarts immediately.

The domestic Hot Water Function will always operate on demand.

3.3TO SHUT DOWN THE APPLIANCE

3.3.1For short periods, switch Summer/Winter switch to Summer and turn off all hot taps.

For long periods switch of the on/off switch (Fig.1). If the appliance is to be shut down for long periods when there is a risk of freezing, then appliance should be drained . Similar refilling must be done by a competent person following approved procedure.

4.CLEANING OF APPLIANCE OUTER CASING

4.1Use a clean damp cloth. Do not use any abrasive cleaners and with a dry cloth lightly polish to protect painted surfaces.

Control Panel and fixiture can be wiped with damp cloth and dried . Spray polishes must not be used on control panel surfaces or switches.

Care must be taken in preventing any liquids entering the appliance.

5.CARE OF YOUR APPLIANCE AND SYSTEM

5.1Annual servicing of your appliance is required to maintain safety and efficiency of its operation. therefore it is reccommended that the appliance is serviced at least once a year and that the whole

of the Heating System be checked at the same time by a qualified installer. If it is know or suspected that a fault exists on the boiler then it MUST NOT be used untill the fault has been corrected by a COMPETENT PERSON. It is essential that the Instructions in this booklet are strictly followed for safe and economic operation of the boiler.

SERVICING SHOULD BE CARRIED OUT BY A QUALIFIED INSTALLER