Ravenheat CSI 150 User Manual

Supplied By www.heating spares.co Tel. 0161 620 6677
CONDENSING LOW NOX SYSTEM INNOVATION SUPER HIGH EFFICIENTY AUTOMATIC
MODULATING COMBINATION BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER
USER’S GUIDE
CSI 120/ 150 (T) Low Nox (with or without built in timer)
It is the law that all gas appliances are installed by a competent person, in accordance with the gas safety installation and use current regulations.To the current Gas Safety (Installation and Use) Regulations B.S.5440:2-(2000).
All CORGI registered installers carry a CORGI ID card and have a registration number. Both should be recorded in your boiler Log book. You can check your installer by calling CORGI direct on 01256 732300.
ESCAPE OF GAS
Should a gas leak be suspected, contact your gas supplier without delay . Do NOT search for gas leaks with a naked fl ame.
WARNING: This appliance must be earthed. Do not touch or tamper with this sealed unit or its components.
1. INTRODUCTION
1.1 Please carefully read information given in the booklet to help you again maximum control from your appliance with minimum trouble and cost.
1.1.1 Y our Ravenheat Condensing Low Nox Combination Boiler has been designed to supply your Central Heating and Domestic Hot Water directly from one unit. When Central Heating is operating, the circulation will be interrupted when Domestic Hot Water is being drawn off. This will normally not affect the level of Heating.
PLEASE NOTE
Due to the high ef ciency and resulting low ue gas
exhaust temperature a white plume of condensation vapour (cool steam) will be emitted from the fl ue outlet terminal, this is quite normal. It will be particularly evident during periods of low outdoor temparatureor when the boiler is working at its optimum performance (Plume Management kit is available on request) IMPORT ANT : In the event of overheat of fl ue gas exhaust temperature, for to prevent malfunction of the appliance, boiler will be stop to operate.
1.2 CLEARANCES AROUND THE BOILER Above 125 mm ( 5 inches) Below 150 mm ( 6 inches) Front 450 mm (18 inches) Sides 5 mm (0.2 inches) 25mm (1inch) in front when installed in a cupboard
1.2.1 Minimum clearences are required for safety and maintenance. Do NOT obstruct any purpose made ventilation opening if boiler has been fi tted in a compartment. Never hang clothes,ect, over the appliance
1.3 USER CONTROLS (Fig.1)
1.3.1 This appliance is designed to operate with the minimum of attention by the User. All the controls are to be found on the control panel.
1.4 OPERA TING SAFETY CHECKS T O PROTECT
YOUR APPLIANCE
1.4.1 Before lighting the Appliance check Central Heating
system pressure (Fig.1 item 7) is not less than 1 bar. If it is below this do not light but consult your installer about refi lling your system as you may have a leak .
1.4.2 In the event of malfunction of the appliance will be indicate by the relevant error code (Table1) on Digital Display of the control panel (Fig.50). These can be Reset by press a RESET button . If lockout code persist leave the appliance shut
down and consult your installer/service
Table 1 01: Lock out from the Flame Control Unit 02: Flue System obstruction
04: Overheat Lockout
06: Open or short circuit on Sanitary probe 12: Open or short circuit on Heating probe 14: Flame simulation on Flame Control Unit 17: Fault on Fan Control 28: Water Flow Switch Fault or low pressure in the heating system 30: Flue temperature fault
1
Supplied By www.heating spares.co Tel. 0161 620 6677
Fig.1
Max
min
2. OPERATING DOMESTIC HOT WATER
2.1 Select summer / Winter switch on Summer position
2.2 Open hot water tap. After about 3 seconds burner will always operate.
2.3 Temperature of Domestic Hot Water can be varied by adjusting the water fl ow rate at the Domestic Hot water The temperature can be set between minimum (40°C) and Maximum (60°C). For maximum temerature of Domestic Hot Water leave the control Knob on Maximum position.
3. OPERA TING HEATING AND HOT WA TER
3.1 TO SET AND ADJUST BUILT-IN TIMER MODEL SEE OPPOSITE P AGE 3
3.2 Select Summer/Winter Switch on Winter position
3.3 Switch on timeclock, adjust room stat and/or thermostatic radiator valves to hogh settings
min
Max
3.3 TO SHUT DOWN THE APPLIANCE
3.3.1 For short periods, switch Summer/Winter switch to Summer and turn off all hot taps. For long periods switch of the on/off switch (Fig.1). If the appliance is to be shut down for long periods when there is a risk of freezing, then appliance should be drained . Similar refi lling must be done by a competent person following approved procedure.
4. CLEANING OF APPLIANCE OUTER CASING
4.1 Use a clean damp cloth. Do not use any abrasive cleaners and with a dry cloth lightly polish to protect painted surfaces. Control Panel and fi xiture can be wiped with damp cloth and dried . Spray polishes must not be used on control panel surfaces or switches. Care must be taken in preventing any liquids entering the appliance.
5. CARE OF YOUR APPLIANCE AND SYSTEM
3.4 Burner will operate, temparature output of Central Heating can be adjusted by Central Heating Control Knob (Fig.1). The Knob can be set between minimum (40°C) and Maximum (85°C).While the appliance is being used to provide Domestic Hot water, the Central Heating will not operate.When Domestic Hot Water is not longer required the appliance will automatically revert to Central Heating and should not noticeably affect the level of central heating. Adjust external controls required settings.
NOTE : An Anti-cycling device is fi tted to the Heating Function. When the boiler reaches its set Maximum temperature it will not operate on heating for about 10 minutes , but if the heating temperature return goes 20°C below the set point, the burner will restarts immediately . The domestic Hot Water Function will always operate on demand.
5.1 Annual servicing of your appliance is required to maintain safety and effi ciency of its operation. therefore it is reccommended that the appliance is serviced at least once a year and that the whole of the Heating System be checked at the same time by a qualifi ed installer. If it is know or suspected that a fault exists on the boiler then it MUST NOT be used untill the fault has been corrected by a COMPETENT PERSON. It is essential that the Instructions in this booklet are strictly followed for safe and economic operation of the boiler.
SERVICING SHOULD BE CARRIED OUT BY A QUALIFIED INSTALLER
Ravenheat Manufacturing Ltd Chartists Way , Morley , Leeds LS 27 9ET
2