IMPORTANT SAFETY INSTRUCTIONS
For the continued safety of yourself and others we recommend that you read the following
safety and installation instructions. Keep this document in a safe location for future reference.
Please heed all warnings and follow all instructions.
Do not use this equipment in a location where it might become wet. Clean only with a damp
cloth.
is equipment may be installed in an industry standard equipment rack. We recommend that
all mounting holes be used, providing the best physical support. e equipment may be used as
a table top device, although stacking of the equipment is dangerous and not recommended.
Do not directly block any of the ventilation openings. If rackmounting, please provide adequate
ventilation. Equipment may be located directly above or below this unit, but note that some
equipment (like large power amplifiers) may cause an unacceptable amount of hum or may
generate too much heat and degrade the performance of this equipment.
Protect the power cord and plug from damage caused by being walked on or pinched. Protect
the line cord, where it exits the unit, from excessive strain. Only use attachments and accessories specified by Rane.
Unplug this equipment during lightning storms or when unused for long periods of time.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power supply cord or plug damage, spilled liquid, fallen
objects into an opened chassis, exposure to rain or moisture, a dropped unit, or abnormal
operation.
105552
OPERATORS MANUAL RA 30
USE RANE
MIC ONLY!
ANALYZER
REALTIME
RA 30
GAIN CAL MICSOURCE
0 dB
METER
RTA
SCALE
NORMAL
1
3
6
120
100
80
WEIGHT
CA RTA
METER
NOISE
PINK
VU
SPL
SIG
OL
+12-12
CAL
-5
-27-30 -24
-25
-21 -15-18
-20
-12 -9
-15
-6 -3
-10
+3 +12+6 +9
0
dB
dB
6.3k5025 31.5 40 16063 80 125100 315200 250 400 500 1k800630 1.25k 1.6k 3.15k2.5k2k 4k 5k 20k8k 10k 16k12.5k
CAL
MIC
AUX
MIC
OFF
LINE
IN
REALTIME ANALYZER
Quick Start
Since the RA 30 does RTA, SPL, and VU all in one, the
first-time user can get a little lost. e real Quick Start is in the
Step-by Step Instructions on page Manual-4. is will tell you
how to set up the RA 30 for your application. In addition, read
these few tips as a reminder of what you already know:
USE MORE THAN ONE TEST MICROPHONE LOCATION. Speaker dispersion characteristics vary greatly, from
beamy highs to boomy bass bins. While performing the pink
noise test, try at least two different test mic locations and average
the two if they differ.
USE ENOUGH PINK NOISE VOLUME TO OVER-
RIDE BACKGROUND NOISE. ere’s no need to run deaf-
ening pink noise levels to EQ a system. Just be sure that no LED
responds when pink noise is turned off (if they do, background
noise is causing erroneous readings and pink noise should be
turned up higher).
MONITORING PROGRAM WITH ANALYZER
DISPLAY. Use any Source as an input. You can use this feature
to identify specific feedback points by watching for red LEDs
during the performance, then apply EQ exactly where it’s needed
very quickly.
WEAR PARTS: is product contains no wear parts.
Manual-1